CWE-134
Use of Externally-Controlled Format String
The product uses a function that accepts a format string as an argument, but the format string originates from an external source.
CVE-2022-35874 (GCVE-0-2022-35874)
Vulnerability from cvelistv5 – Published: 2022-10-25 16:34 – Updated: 2025-04-15 18:43- CWE-134 - Use of Externally-Controlled Format String
| Vendor | Product | Version | |
|---|---|---|---|
| abode systems, inc. | iota All-In-One Security Kit |
Affected:
6.9X
Affected: 6.9Z |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.073Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-35874",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-15T18:18:18.143539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T18:43:28.700Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "iota All-In-One Security Kit",
"vendor": "abode systems, inc.",
"versions": [
{
"status": "affected",
"version": "6.9X"
},
{
"status": "affected",
"version": "6.9Z"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `ssid` and `ssid_hex` configuration parameters, as used within the `testWifiAP` XCMD handler"
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-03T22:11:40.626Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-35874",
"datePublished": "2022-10-25T16:34:13.296Z",
"dateReserved": "2022-07-15T00:00:00.000Z",
"dateUpdated": "2025-04-15T18:43:28.700Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35875 (GCVE-0-2022-35875)
Vulnerability from cvelistv5 – Published: 2022-10-25 16:34 – Updated: 2025-04-15 18:43- CWE-134 - Use of Externally-Controlled Format String
| Vendor | Product | Version | |
|---|---|---|---|
| abode systems, inc. | iota All-In-One Security Kit |
Affected:
6.9X
Affected: 6.9Z |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.149Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-35875",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-15T18:18:13.639750Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T18:43:18.131Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "iota All-In-One Security Kit",
"vendor": "abode systems, inc.",
"versions": [
{
"status": "affected",
"version": "6.9X"
},
{
"status": "affected",
"version": "6.9Z"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `wpapsk` configuration parameter, as used within the `testWifiAP` XCMD handler"
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-03T22:11:40.626Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-35875",
"datePublished": "2022-10-25T16:34:14.376Z",
"dateReserved": "2022-07-15T00:00:00.000Z",
"dateUpdated": "2025-04-15T18:43:18.131Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35876 (GCVE-0-2022-35876)
Vulnerability from cvelistv5 – Published: 2022-10-25 16:34 – Updated: 2025-04-15 18:43- CWE-134 - Use of Externally-Controlled Format String
| Vendor | Product | Version | |
|---|---|---|---|
| abode systems, inc. | iota All-In-One Security Kit |
Affected:
6.9X
Affected: 6.9Z |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.156Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-35876",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-15T18:18:08.508638Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T18:43:08.175Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "iota All-In-One Security Kit",
"vendor": "abode systems, inc.",
"versions": [
{
"status": "affected",
"version": "6.9X"
},
{
"status": "affected",
"version": "6.9Z"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `default_key_id` and `key` configuration parameters, as used within the `testWifiAP` XCMD handler"
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-03T22:11:40.626Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-35876",
"datePublished": "2022-10-25T16:34:15.364Z",
"dateReserved": "2022-07-15T00:00:00.000Z",
"dateUpdated": "2025-04-15T18:43:08.175Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35877 (GCVE-0-2022-35877)
Vulnerability from cvelistv5 – Published: 2022-10-25 16:34 – Updated: 2025-04-15 18:42- CWE-134 - Use of Externally-Controlled Format String
| Vendor | Product | Version | |
|---|---|---|---|
| abode systems, inc. | iota All-In-One Security Kit |
Affected:
6.9X
Affected: 6.9Z |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.158Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-35877",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-15T18:18:03.743608Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T18:42:57.864Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "iota All-In-One Security Kit",
"vendor": "abode systems, inc.",
"versions": [
{
"status": "affected",
"version": "6.9X"
},
{
"status": "affected",
"version": "6.9Z"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `default_key_id` configuration parameter, as used within the `testWifiAP` XCMD handler"
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-03T22:11:40.626Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1581"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-35877",
"datePublished": "2022-10-25T16:34:16.353Z",
"dateReserved": "2022-07-15T00:00:00.000Z",
"dateUpdated": "2025-04-15T18:42:57.864Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35878 (GCVE-0-2022-35878)
Vulnerability from cvelistv5 – Published: 2022-10-25 16:34 – Updated: 2025-04-15 18:42- CWE-134 - Use of Externally-Controlled Format String
| Vendor | Product | Version | |
|---|---|---|---|
| abode systems, inc. | iota All-In-One Security Kit |
Affected:
6.9X
Affected: 6.9Z |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.172Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1583"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-35878",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-15T18:16:46.391540Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T18:42:48.179Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "iota All-In-One Security Kit",
"vendor": "abode systems, inc.",
"versions": [
{
"status": "affected",
"version": "6.9X"
},
{
"status": "affected",
"version": "6.9Z"
}
]
}
],
"datePublic": "2022-10-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Four format string injection vulnerabilities exist in the UPnP logging functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted UPnP negotiation can lead to memory corruption, information disclosure, and denial of service. An attacker can host a malicious UPnP service to trigger these vulnerabilities.This vulnerability arises from format string injection via `ST` and `Location` HTTP response headers, as used within the `DoEnumUPnPService` action handler."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-25T00:00:00.000Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1583"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-35878",
"datePublished": "2022-10-25T16:34:17.358Z",
"dateReserved": "2022-07-15T00:00:00.000Z",
"dateUpdated": "2025-04-15T18:42:48.179Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35879 (GCVE-0-2022-35879)
Vulnerability from cvelistv5 – Published: 2022-10-25 16:34 – Updated: 2025-04-15 18:42- CWE-134 - Use of Externally-Controlled Format String
| Vendor | Product | Version | |
|---|---|---|---|
| abode systems, inc. | iota All-In-One Security Kit |
Affected:
6.9X
Affected: 6.9Z |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.143Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1583"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-35879",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-15T18:16:43.151664Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T18:42:35.804Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "iota All-In-One Security Kit",
"vendor": "abode systems, inc.",
"versions": [
{
"status": "affected",
"version": "6.9X"
},
{
"status": "affected",
"version": "6.9Z"
}
]
}
],
"datePublic": "2022-10-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Four format string injection vulnerabilities exist in the UPnP logging functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted UPnP negotiation can lead to memory corruption, information disclosure, and denial of service. An attacker can host a malicious UPnP service to trigger these vulnerabilities.This vulnerability arises from format string injection via `controlURL` XML tag, as used within the `DoUpdateUPnPbyService` action handler."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-25T00:00:00.000Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1583"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-35879",
"datePublished": "2022-10-25T16:34:18.345Z",
"dateReserved": "2022-07-15T00:00:00.000Z",
"dateUpdated": "2025-04-15T18:42:35.804Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35880 (GCVE-0-2022-35880)
Vulnerability from cvelistv5 – Published: 2022-10-25 16:34 – Updated: 2025-04-15 18:42- CWE-134 - Use of Externally-Controlled Format String
| Vendor | Product | Version | |
|---|---|---|---|
| abode systems, inc. | iota All-In-One Security Kit |
Affected:
6.9X
Affected: 6.9Z |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.177Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1583"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-35880",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-15T18:16:39.935579Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T18:42:26.814Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "iota All-In-One Security Kit",
"vendor": "abode systems, inc.",
"versions": [
{
"status": "affected",
"version": "6.9X"
},
{
"status": "affected",
"version": "6.9Z"
}
]
}
],
"datePublic": "2022-10-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Four format string injection vulnerabilities exist in the UPnP logging functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted UPnP negotiation can lead to memory corruption, information disclosure, and denial of service. An attacker can host a malicious UPnP service to trigger these vulnerabilities.This vulnerability arises from format string injection via `NewInternalClient` XML tag, as used within the `DoUpdateUPnPbyService` action handler."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-25T00:00:00.000Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1583"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-35880",
"datePublished": "2022-10-25T16:34:19.367Z",
"dateReserved": "2022-07-15T00:00:00.000Z",
"dateUpdated": "2025-04-15T18:42:26.814Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35881 (GCVE-0-2022-35881)
Vulnerability from cvelistv5 – Published: 2022-10-25 16:34 – Updated: 2025-04-15 18:42- CWE-134 - Use of Externally-Controlled Format String
| Vendor | Product | Version | |
|---|---|---|---|
| abode systems, inc. | iota All-In-One Security Kit |
Affected:
6.9X
Affected: 6.9Z |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.163Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1583"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-35881",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-15T18:16:36.689362Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T18:42:12.665Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "iota All-In-One Security Kit",
"vendor": "abode systems, inc.",
"versions": [
{
"status": "affected",
"version": "6.9X"
},
{
"status": "affected",
"version": "6.9Z"
}
]
}
],
"datePublic": "2022-10-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Four format string injection vulnerabilities exist in the UPnP logging functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted UPnP negotiation can lead to memory corruption, information disclosure, and denial of service. An attacker can host a malicious UPnP service to trigger these vulnerabilities.This vulnerability arises from format string injection via `errorCode` and `errorDescription` XML tags, as used within the `DoUpdateUPnPbyService` action handler."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-25T00:00:00.000Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1583"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-35881",
"datePublished": "2022-10-25T16:34:20.328Z",
"dateReserved": "2022-07-15T00:00:00.000Z",
"dateUpdated": "2025-04-15T18:42:12.665Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35884 (GCVE-0-2022-35884)
Vulnerability from cvelistv5 – Published: 2022-10-25 16:34 – Updated: 2025-04-15 18:41- CWE-134 - Use of Externally-Controlled Format String
| Vendor | Product | Version | |
|---|---|---|---|
| abode systems, inc. | iota All-In-One Security Kit |
Affected:
6.9X
Affected: 6.9Z |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.250Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1585",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1585"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-35884",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-15T18:17:59.157749Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T18:41:57.938Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "iota All-In-One Security Kit",
"vendor": "abode systems, inc.",
"versions": [
{
"status": "affected",
"version": "6.9X"
},
{
"status": "affected",
"version": "6.9Z"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Four format string injection vulnerabilities exist in the web interface /action/wirelessConnect functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted HTTP request can lead to memory corruption, information disclosure and denial of service. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.This vulnerability arises from format string injection via the `ssid_hex` HTTP parameter, as used within the `/action/wirelessConnect` handler."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-03T22:11:40.626Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1585",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1585"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-35884",
"datePublished": "2022-10-25T16:34:21.353Z",
"dateReserved": "2022-07-15T00:00:00.000Z",
"dateUpdated": "2025-04-15T18:41:57.938Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35885 (GCVE-0-2022-35885)
Vulnerability from cvelistv5 – Published: 2022-10-25 16:34 – Updated: 2025-04-15 18:41- CWE-134 - Use of Externally-Controlled Format String
| Vendor | Product | Version | |
|---|---|---|---|
| abode systems, inc. | iota All-In-One Security Kit |
Affected:
6.9X
Affected: 6.9Z |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.211Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1585",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1585"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-35885",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-15T18:17:55.252840Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T18:41:46.855Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "iota All-In-One Security Kit",
"vendor": "abode systems, inc.",
"versions": [
{
"status": "affected",
"version": "6.9X"
},
{
"status": "affected",
"version": "6.9Z"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Four format string injection vulnerabilities exist in the web interface /action/wirelessConnect functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted HTTP request can lead to memory corruption, information disclosure and denial of service. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.This vulnerability arises from format string injection via the `wpapsk_hex` HTTP parameter, as used within the `/action/wirelessConnect` handler."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-03T22:11:40.626Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1585",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1585"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-35885",
"datePublished": "2022-10-25T16:34:22.339Z",
"dateReserved": "2022-07-15T00:00:00.000Z",
"dateUpdated": "2025-04-15T18:41:46.855Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Phase: Requirements
Description:
- Choose a language that is not subject to this flaw.
Mitigation
Phase: Implementation
Description:
- Ensure that all format string functions are passed a static string which cannot be controlled by the user, and that the proper number of arguments are always sent to that function as well. If at all possible, use functions that do not support the %n operator in format strings. [REF-116] [REF-117]
Mitigation
Phase: Build and Compilation
Description:
- Run compilers and linkers with high warning levels, since they may detect incorrect usage.
CAPEC-135: Format String Injection
An adversary includes formatting characters in a string input field on the target application. Most applications assume that users will provide static text and may respond unpredictably to the presence of formatting character. For example, in certain functions of the C programming languages such as printf, the formatting character %s will print the contents of a memory location expecting this location to identify a string and the formatting character %n prints the number of DWORD written in the memory. An adversary can use this to read or write to memory locations or files, or simply to manipulate the value of the resulting text in unexpected ways. Reading or writing memory may result in program crashes and writing memory could result in the execution of arbitrary code if the adversary can write to the program stack.
CAPEC-67: String Format Overflow in syslog()
This attack targets applications and software that uses the syslog() function insecurely. If an application does not explicitely use a format string parameter in a call to syslog(), user input can be placed in the format string parameter leading to a format string injection attack. Adversaries can then inject malicious format string commands into the function call leading to a buffer overflow. There are many reported software vulnerabilities with the root cause being a misuse of the syslog() function.