CWE-319

Cleartext Transmission of Sensitive Information

The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.

CVE-2025-27457 (GCVE-0-2025-27457)

Vulnerability from cvelistv5 – Published: 2025-07-03 11:32 – Updated: 2025-07-03 13:15
VLAI
Title
CVE-2025-27457
Summary
All communication between the VNC server and client(s) is unencrypted. This allows an attacker to intercept the traffic and obtain sensitive data.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
URL Tags
https://www.endress.com x_Endress+Hauser
https://sick.com/psirt x_SICK PSIRT Security Advisories
https://www.cisa.gov/resources-tools/resources/ic… x_ICS-CERT recommended practices on Industrial Security
https://www.first.org/cvss/calculator/3.1 x_CVSS v3.1 Calculator
https://www.sick.com/.well-known/csaf/white/2025/… x_The canonical URL.
https://www.sick.com/.well-known/csaf/white/2025/… vendor-advisory
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27457",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-03T12:59:46.824815Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-03T13:15:48.078Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Endress+Hauser MEAC300-FNADE4",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "vers:all/*",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAll communication between the VNC server and client(s) is unencrypted. This allows an attacker to intercept the traffic and obtain sensitive data.\u003c/p\u003e"
            }
          ],
          "value": "All communication between the VNC server and client(s) is unencrypted. This allows an attacker to intercept the traffic and obtain sensitive data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "environmentalScore": 6.5,
            "environmentalSeverity": "MEDIUM",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "temporalScore": 6.5,
            "temporalSeverity": "MEDIUM",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-03T11:32:59.576Z",
        "orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
        "shortName": "SICK AG"
      },
      "references": [
        {
          "tags": [
            "x_Endress+Hauser"
          ],
          "url": "https://www.endress.com"
        },
        {
          "tags": [
            "x_SICK PSIRT Security Advisories"
          ],
          "url": "https://sick.com/psirt"
        },
        {
          "tags": [
            "x_ICS-CERT recommended practices on Industrial Security"
          ],
          "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
        },
        {
          "tags": [
            "x_CVSS v3.1 Calculator"
          ],
          "url": "https://www.first.org/cvss/calculator/3.1"
        },
        {
          "tags": [
            "x_The canonical URL."
          ],
          "url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0008.json"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://sick.com/psirt"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0008.pdf"
        }
      ],
      "source": {
        "advisory": "SCA-2025-0008",
        "discovery": "INTERNAL"
      },
      "title": "CVE-2025-27457",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003ePlease make sure that you apply general security practices when operating the MEAC300-FNADE4. The following General Security Practices could mitigate the associated security risk.\u003c/p\u003e"
            }
          ],
          "value": "Please make sure that you apply general security practices when operating the MEAC300-FNADE4. The following General Security Practices could mitigate the associated security risk."
        }
      ],
      "x_generator": {
        "engine": "csaf2cve 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
    "assignerShortName": "SICK AG",
    "cveId": "CVE-2025-27457",
    "datePublished": "2025-07-03T11:32:59.576Z",
    "dateReserved": "2025-02-26T08:40:02.358Z",
    "dateUpdated": "2025-07-03T13:15:48.078Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-27594 (GCVE-0-2025-27594)

Vulnerability from cvelistv5 – Published: 2025-03-14 12:50 – Updated: 2025-03-14 13:35
VLAI
Title
Unencrypted transmission of password hash
Summary
The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device authentication is performed. An attacker can thereby intercept the authentication hash and use it to log into the device using a pass-the-hash attack.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
SICK AG SICK DL100-2xxxxxxx Affected: all versions (custom)
Create a notification for this product.
Date Public
2025-03-14 12:32
Credits
Leonard Lewedei
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27594",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-14T13:35:21.904586Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-14T13:35:28.200Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "SICK DL100-2xxxxxxx",
          "vendor": "SICK AG",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Leonard Lewedei"
        }
      ],
      "datePublic": "2025-03-14T12:32:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device authentication is performed. An attacker can thereby intercept the authentication hash and use it to log into the device using a pass-the-hash attack.\u003cbr\u003e"
            }
          ],
          "value": "The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device authentication is performed. An attacker can thereby intercept the authentication hash and use it to log into the device using a pass-the-hash attack."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-14T12:50:15.198Z",
        "orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
        "shortName": "SICK AG"
      },
      "references": [
        {
          "tags": [
            "x_SICK PSIRT Website"
          ],
          "url": "https://sick.com/psirt"
        },
        {
          "tags": [
            "x_SICK Operating Guidelines"
          ],
          "url": "https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF"
        },
        {
          "tags": [
            "x_ICS-CERT recommended practices on Industrial Security"
          ],
          "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
        },
        {
          "tags": [
            "x_CVSS v3.1 Calculator"
          ],
          "url": "https://www.first.org/cvss/calculator/3.1"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0004.pdf"
        },
        {
          "tags": [
            "vendor-advisory",
            "x_csaf"
          ],
          "url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0004.json"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://github.security.telekom.com/2025/03/multiple-vulnerabilities-in-sick-dl100.html"
        }
      ],
      "source": {
        "advisory": "sca-2025-0004",
        "discovery": "EXTERNAL"
      },
      "title": "Unencrypted transmission of password hash",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Please make sure that you apply general security practices when operating the products. The following General Security Practices and Operating Guidelines could mitigate the associated security risk.\u003cbr\u003e"
            }
          ],
          "value": "Please make sure that you apply general security practices when operating the products. The following General Security Practices and Operating Guidelines could mitigate the associated security risk."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
    "assignerShortName": "SICK AG",
    "cveId": "CVE-2025-27594",
    "datePublished": "2025-03-14T12:50:15.198Z",
    "dateReserved": "2025-03-03T13:27:07.018Z",
    "dateUpdated": "2025-03-14T13:35:28.200Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-27720 (GCVE-0-2025-27720)

Vulnerability from cvelistv5 – Published: 2025-05-08 22:43 – Updated: 2025-05-09 04:03
VLAI
Title
Pixmeo OsiriX MD Cleartext Transmission of Sensitive Information
Summary
The Pixmeo Osirix MD Web Portal sends credential information without encryption, which could allow an attacker to steal credentials.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
Impacted products
Vendor Product Version
Pixmeo OsiriX MD Affected: 0 , ≤ 14.0.1 (Build 2024-02-28) (custom)
Create a notification for this product.
Date Public
2025-05-08 17:00
Credits
Chizuru Toyama of TXOne Networks and Canaan Kao of TXOne Networks reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27720",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-09T04:03:15.144661Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-09T04:03:25.385Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OsiriX MD",
          "vendor": "Pixmeo",
          "versions": [
            {
              "lessThanOrEqual": "14.0.1 (Build 2024-02-28)",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Chizuru Toyama of TXOne Networks and Canaan Kao of TXOne Networks reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2025-05-08T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe Pixmeo Osirix MD Web Portal sends credential information without encryption, which could allow an attacker to steal credentials.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "The Pixmeo Osirix MD Web Portal sends credential information without encryption, which could allow an attacker to steal credentials."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-08T22:43:28.046Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-128-01"
        },
        {
          "url": "https://www.osirix-viewer.com/osirix/osirix-md/"
        },
        {
          "url": "https://www.osirix-viewer.com/about/contact/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003ePixmeo recommends users to download the latest version of \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.osirix-viewer.com/osirix/osirix-md/\"\u003eOsiriX MD\u003c/a\u003e.\u003c/p\u003e\u003cp\u003eFor additional support regarding OsiriX MD, users should \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.osirix-viewer.com/about/contact/\"\u003econtact Pixmeo\u003c/a\u003e\u0026nbsp;directly.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Pixmeo recommends users to download the latest version of  OsiriX MD https://www.osirix-viewer.com/osirix/osirix-md/ .\n\nFor additional support regarding OsiriX MD, users should  contact Pixmeo https://www.osirix-viewer.com/about/contact/ \u00a0directly."
        }
      ],
      "source": {
        "advisory": "ICSMA-25-128-01",
        "discovery": "EXTERNAL"
      },
      "title": "Pixmeo OsiriX MD Cleartext Transmission of Sensitive Information",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-27720",
    "datePublished": "2025-05-08T22:43:28.046Z",
    "dateReserved": "2025-04-03T20:57:04.866Z",
    "dateUpdated": "2025-05-09T04:03:25.385Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-27722 (GCVE-0-2025-27722)

Vulnerability from cvelistv5 – Published: 2025-04-09 09:03 – Updated: 2025-04-09 15:07
VLAI
Summary
Cleartext transmission of sensitive information issue exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a man-in-the-middle attack may allow a remote unauthenticated attacker to eavesdrop the communication and obtain the authentication information.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext transmission of sensitive information
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27722",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-09T15:05:43.543317Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-09T15:07:39.314Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC-WPS-11ac",
          "vendor": "Inaba Denki Sangyo Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "v2.0.03P and earlier"
            }
          ]
        },
        {
          "product": "AC-WPS-11ac-P",
          "vendor": "Inaba Denki Sangyo Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "v2.0.03P and earlier"
            }
          ]
        },
        {
          "product": "AC-WPSM-11ac",
          "vendor": "Inaba Denki Sangyo Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "v2.0.03P and earlier"
            }
          ]
        },
        {
          "product": "AC-WPSM-11ac-P",
          "vendor": "Inaba Denki Sangyo Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "v2.0.03P and earlier"
            }
          ]
        },
        {
          "product": "AC-PD-WPS-11ac",
          "vendor": "Inaba Denki Sangyo Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "v2.0.03P and earlier"
            }
          ]
        },
        {
          "product": "AC-PD-WPS-11ac-P",
          "vendor": "Inaba Denki Sangyo Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "v2.0.03P and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cleartext transmission of sensitive information issue exists in Wi-Fi AP UNIT \u0027AC-WPS-11ac series\u0027. If exploited, a man-in-the-middle attack may allow a remote unauthenticated attacker to eavesdrop the communication and obtain the authentication information."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "Cleartext transmission of sensitive information",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-09T09:03:26.029Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.inaba.co.jp/abaniact/news/security_20250404.pdf"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU93925742/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2025-27722",
    "datePublished": "2025-04-09T09:03:26.029Z",
    "dateReserved": "2025-03-24T07:21:19.872Z",
    "dateUpdated": "2025-04-09T15:07:39.314Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-27903 (GCVE-0-2025-27903)

Vulnerability from cvelistv5 – Published: 2026-02-17 19:32 – Updated: 2026-02-17 20:29
VLAI
Title
Multiple vulnerabilities in IBM Java SDK affecting Db2 Recovery Expert for Linux, Unix and Windows
Summary
IBM DB2 Recovery Expert for LUW 5.5 Interim Fix 002 IBM Db2 Recovery Expert for Linux, UNIX and Windows transmits data in a cleartext communication channel that could allow an attacker to obtain sensitive information using man in the middle techniques.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
ibm
References
URL Tags
https://www.ibm.com/support/pages/node/7259901 vendor-advisorypatch
Impacted products
Vendor Product Version
IBM DB2 Recovery Expert for LUW Affected: 5.5 Interim Fix 002 (semver)
    cpe:2.3:a:ibm:db2_recovery_expert_for_luw:5.5:interim_fix_002:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27903",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-17T20:28:08.135809Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-17T20:29:07.981Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:a:ibm:db2_recovery_expert_for_luw:5.5:interim_fix_002:*:*:*:*:*:*"
          ],
          "product": "DB2 Recovery Expert for LUW",
          "vendor": "IBM",
          "versions": [
            {
              "status": "affected",
              "version": "5.5 Interim Fix 002",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eIBM DB2 Recovery Expert for LUW 5.5 Interim Fix 002 IBM Db2 Recovery Expert for Linux, UNIX and Windows transmits data in a cleartext communication channel that could allow an attacker to obtain sensitive information using man in the middle techniques.\u003c/p\u003e"
            }
          ],
          "value": "IBM DB2 Recovery Expert for LUW 5.5 Interim Fix 002 IBM Db2 Recovery Expert for Linux, UNIX and Windows transmits data in a cleartext communication channel that could allow an attacker to obtain sensitive information using man in the middle techniques."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-17T19:32:05.961Z",
        "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
        "shortName": "ibm"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://www.ibm.com/support/pages/node/7259901"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eUpgrade to DB2 Recovery Expert for Linux, Unix and Windows v5.5.0.1 Interim Fix 8 available on Fix Central.\u003c/p\u003e"
            }
          ],
          "value": "Upgrade to DB2 Recovery Expert for Linux, Unix and Windows v5.5.0.1 Interim Fix 8 available on Fix Central."
        }
      ],
      "title": "Multiple vulnerabilities in IBM Java SDK affecting Db2 Recovery Expert for Linux, Unix and Windows",
      "x_generator": {
        "engine": "ibm-cvegen"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
    "assignerShortName": "ibm",
    "cveId": "CVE-2025-27903",
    "datePublished": "2026-02-17T19:32:05.961Z",
    "dateReserved": "2025-03-10T17:14:03.091Z",
    "dateUpdated": "2026-02-17T20:29:07.981Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-2818 (GCVE-0-2025-2818)

Vulnerability from cvelistv5 – Published: 2025-07-17 19:17 – Updated: 2025-07-17 20:11
VLAI
Summary
A vulnerability was reported in version 1.0 of the Bluetooth Transmission Alliance protocol adopted by Motorola Smart Connect Android Application that could allow a nearby attacker within the Bluetooth interaction range to intercept files when transferred to a device not paired in Smart Connect.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
Impacted products
Vendor Product Version
Motorola Smart Connect Android Application Affected: 0 , < 08.0.1.011.0 (custom)
Create a notification for this product.
Credits
Motorola/Lenovo thanks MS. Candidate Bai Xingyu, Ph.D. Candidate Liu Xiaofeng, Ph.D. Candidate Song Xiangpu, Prof. Hu Chengyu, Prof. Guo Shanqing from Shandong University for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2818",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-17T20:11:21.730503Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-17T20:11:30.889Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Smart Connect Android Application",
          "vendor": "Motorola",
          "versions": [
            {
              "lessThan": "08.0.1.011.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:motorola:smart_connect:*:*:*:*:*:android:*:*",
                  "versionEndExcluding": "08.0.1.011.0",
                  "vulnerable": true
                }
              ],
              "operator": "OR"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Motorola/Lenovo thanks MS. Candidate Bai Xingyu, Ph.D. Candidate Liu Xiaofeng, Ph.D. Candidate Song Xiangpu, Prof. Hu Chengyu, Prof. Guo Shanqing from Shandong University for reporting this issue."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA vulnerability was reported in version 1.0 of the Bluetooth Transmission Alliance protocol adopted by Motorola Smart Connect Android Application that could allow a nearby attacker within the Bluetooth interaction range to intercept files when transferred to a device not paired in Smart Connect. \u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "A vulnerability was reported in version 1.0 of the Bluetooth Transmission Alliance protocol adopted by Motorola Smart Connect Android Application that could allow a nearby attacker within the Bluetooth interaction range to intercept files when transferred to a device not paired in Smart Connect."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-17T19:17:51.443Z",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "url": "https://en-us.support.motorola.com/app/answers/detail/a_id/186727"
        },
        {
          "url": "https://support.lenovo.com/us/en/product_security/LEN-188742"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpdate Motorola Smart Connect Android Application to version 08.0.1.011.0 (or newer).\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Update Motorola Smart Connect Android Application to version 08.0.1.011.0 (or newer)."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2025-2818",
    "datePublished": "2025-07-17T19:17:51.443Z",
    "dateReserved": "2025-03-26T14:25:01.182Z",
    "dateUpdated": "2025-07-17T20:11:30.889Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2861 (GCVE-0-2025-2861)

Vulnerability from cvelistv5 – Published: 2025-03-28 13:11 – Updated: 2025-04-03 12:58
VLAI
Title
Cleartext Transmission of Sensitive Information vulnerability in saTECH BCU
Summary
SaTECH BCU in its firmware version 2.1.3 uses the HTTP protocol. The use of the HTTP protocol for web browsing has the problem that information is exchanged in unencrypted text. Since sensitive data such as credentials are exchanged, an attacker could obtain them and log in legitimately.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
Impacted products
Vendor Product Version
Arteche saTECH BCU Affected: 2.1.3
Create a notification for this product.
Date Public
2025-03-27 11:00
Credits
Aarón Flecha Gabriel Vía Echezarreta
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2861",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-28T13:35:01.742369Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-03T12:58:35.556Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "saTECH BCU",
          "vendor": "Arteche",
          "versions": [
            {
              "status": "affected",
              "version": "2.1.3"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Aar\u00f3n Flecha"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Gabriel V\u00eda Echezarreta"
        }
      ],
      "datePublic": "2025-03-27T11:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SaTECH BCU in its firmware version 2.1.3 uses the HTTP protocol. The use of the HTTP protocol for web browsing has the problem that information is exchanged in unencrypted text. Since sensitive data such as credentials are exchanged, an attacker could obtain them and log in legitimately."
            }
          ],
          "value": "SaTECH BCU in its firmware version 2.1.3 uses the HTTP protocol. The use of the HTTP protocol for web browsing has the problem that information is exchanged in unencrypted text. Since sensitive data such as credentials are exchanged, an attacker could obtain them and log in legitimately."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-28T13:11:29.282Z",
        "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "shortName": "INCIBE"
      },
      "references": [
        {
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-arteches-satech-bcu"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The vulnerability has been fixed by Arteche in firmware version 2.2.1."
            }
          ],
          "value": "The vulnerability has been fixed by Arteche in firmware version 2.2.1."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Cleartext Transmission of Sensitive Information vulnerability in saTECH BCU",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
    "assignerShortName": "INCIBE",
    "cveId": "CVE-2025-2861",
    "datePublished": "2025-03-28T13:11:29.282Z",
    "dateReserved": "2025-03-27T10:59:42.618Z",
    "dateUpdated": "2025-04-03T12:58:35.556Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-31972 (GCVE-0-2025-31972)

Vulnerability from cvelistv5 – Published: 2025-08-28 16:50 – Updated: 2025-08-28 17:14
VLAI
Title
HCL BigFix Service Management (SM) is affected by a Sensitive Information Exposure vulnerability
Summary
HCL BigFix SM is affected by a Sensitive Information Exposure vulnerability where internal connections do not use TLS encryption which could allow an attacker unauthorized access to sensitive data transmitted between internal components.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
HCL
Impacted products
Date Public
2025-08-28 16:46
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-31972",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-28T17:14:36.387228Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-28T17:14:41.728Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "BigFix Service Management (SM)",
          "vendor": "HCL Software",
          "versions": [
            {
              "status": "affected",
              "version": "23",
              "versionType": "Framework"
            }
          ]
        }
      ],
      "datePublic": "2025-08-28T16:46:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "HCL BigFix SM is affected by a Sensitive Information Exposure vulnerability where internal connections do not use TLS encryption which could allow an attacker unauthorized access to sensitive data transmitted between internal components.\u003cbr\u003e"
            }
          ],
          "value": "HCL BigFix SM is affected by a Sensitive Information Exposure vulnerability where internal connections do not use TLS encryption which could allow an attacker unauthorized access to sensitive data transmitted between internal components."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-28T16:50:07.540Z",
        "orgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
        "shortName": "HCL"
      },
      "references": [
        {
          "url": "https://support.hcl-software.com/csm?id=kb_article\u0026sysparm_article=KB0123631"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "HCL BigFix Service Management (SM) is affected by a Sensitive Information Exposure vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
    "assignerShortName": "HCL",
    "cveId": "CVE-2025-31972",
    "datePublished": "2025-08-28T16:50:07.540Z",
    "dateReserved": "2025-04-01T18:46:26.620Z",
    "dateUpdated": "2025-08-28T17:14:41.728Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-31981 (GCVE-0-2025-31981)

Vulnerability from cvelistv5 – Published: 2026-04-21 14:26 – Updated: 2026-04-21 19:28
VLAI
Title
HCL BigFix Service Management (SM) Discovery is vulnerable to unenforced encryption
Summary
HCL BigFix Service Management (SM) Discovery is vulnerable to unenforced encryption due to port 80 (HTTP) being open, allowing unencrypted access.  An attacker with access to the network traffic can sniff packets from the connection and uncover the data.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext transmission of sensitive information
Assigner
HCL
Impacted products
Date Public
2026-04-20 13:55
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-31981",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-21T19:28:07.221158Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-21T19:28:19.397Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "BigFix Service Management (SM)",
          "vendor": "HCLSoftware",
          "versions": [
            {
              "status": "affected",
              "version": "23"
            }
          ]
        }
      ],
      "datePublic": "2026-04-20T13:55:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "HCL BigFix Service Management (SM) Discovery is vulnerable to unenforced encryption due to port 80 (HTTP) being open, allowing unencrypted access.\u0026nbsp; An attacker with access to the network traffic can sniff packets from the connection and uncover the data.\u0026nbsp;"
            }
          ],
          "value": "HCL BigFix Service Management (SM) Discovery is vulnerable to unenforced encryption due to port 80 (HTTP) being open, allowing unencrypted access.\u00a0 An attacker with access to the network traffic can sniff packets from the connection and uncover the data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext transmission of sensitive information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-21T14:28:24.452Z",
        "orgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
        "shortName": "HCL"
      },
      "references": [
        {
          "url": "https://support.hcl-software.com/csm?id=kb_article\u0026sysparm_article=KB0127605"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "HCL BigFix Service Management (SM) Discovery is vulnerable to unenforced encryption",
      "x_generator": {
        "engine": "Vulnogram 1.0.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
    "assignerShortName": "HCL",
    "cveId": "CVE-2025-31981",
    "datePublished": "2026-04-21T14:26:39.400Z",
    "dateReserved": "2025-04-01T18:46:33.655Z",
    "dateUpdated": "2026-04-21T19:28:19.397Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-32793 (GCVE-0-2025-32793)

Vulnerability from cvelistv5 – Published: 2025-04-21 15:34 – Updated: 2025-04-21 15:48
VLAI
Title
Cilium packets from terminating endpoints may not be encrypted in Wireguard-enabled clusters
Summary
Cilium is a networking, observability, and security solution with an eBPF-based dataplane. Versions 1.15.0 to 1.15.15, 1.16.0 to 1.16.8, and 1.17.0 to 1.17.2, are vulnerable when using Wireguard transparent encryption in a Cilium cluster, packets that originate from a terminating endpoint can leave the source node without encryption due to a race condition in how traffic is processed by Cilium. This issue has been patched in versions 1.15.16, 1.16.9, and 1.17.3. There are no workarounds available for this issue.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
cilium cilium Affected: >= v1.13.0, < v1.15.16
Affected: >= v1.16.0, < v1.16.9
Affected: >= v1.17.0, < v1.17.3
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32793",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-21T15:48:39.310786Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T15:48:55.214Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "cilium",
          "vendor": "cilium",
          "versions": [
            {
              "status": "affected",
              "version": "\u003e= v1.13.0, \u003c v1.15.16"
            },
            {
              "status": "affected",
              "version": "\u003e= v1.16.0, \u003c v1.16.9"
            },
            {
              "status": "affected",
              "version": "\u003e= v1.17.0, \u003c v1.17.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cilium is a networking, observability, and security solution with an eBPF-based dataplane. Versions 1.15.0 to 1.15.15, 1.16.0 to 1.16.8, and 1.17.0 to 1.17.2, are vulnerable when using Wireguard transparent encryption in a Cilium cluster, packets that originate from a terminating endpoint can leave the source node without encryption due to a race condition in how traffic is processed by Cilium. This issue has been patched in versions 1.15.16, 1.16.9, and 1.17.3. There are no workarounds available for this issue."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-21T15:34:14.315Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/cilium/cilium/security/advisories/GHSA-5vxx-c285-pcq4",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/cilium/cilium/security/advisories/GHSA-5vxx-c285-pcq4"
        },
        {
          "name": "https://github.com/cilium/cilium/pull/38592",
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/cilium/cilium/pull/38592"
        }
      ],
      "source": {
        "advisory": "GHSA-5vxx-c285-pcq4",
        "discovery": "UNKNOWN"
      },
      "title": "Cilium packets from terminating endpoints may not be encrypted in Wireguard-enabled clusters"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2025-32793",
    "datePublished": "2025-04-21T15:34:14.315Z",
    "dateReserved": "2025-04-10T12:51:12.281Z",
    "dateUpdated": "2025-04-21T15:48:55.214Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phase: Architecture and Design

Description:

  • Before transmitting, encrypt the data using reliable, confidentiality-protecting cryptographic protocols.
Mitigation

Phase: Implementation

Description:

  • When using web applications with SSL, use SSL for the entire session from login to logout, not just for the initial login page.
Mitigation

Phase: Implementation

Description:

  • When designing hardware platforms, ensure that approved encryption algorithms (such as those recommended by NIST) protect paths from security critical data to trusted user applications.
Mitigation

Phase: Testing

Description:

  • Use tools and techniques that require manual (human) analysis, such as penetration testing, threat modeling, and interactive tools that allow the tester to record and modify an active session. These may be more effective than strictly automated techniques. This is especially the case with weaknesses that are related to design and business rules.
Mitigation

Phase: Operation

Description:

  • Configure servers to use encrypted channels for communication, which may include SSL or other secure protocols.
CAPEC-102: Session Sidejacking

Session sidejacking takes advantage of an unencrypted communication channel between a victim and target system. The attacker sniffs traffic on a network looking for session tokens in unencrypted traffic. Once a session token is captured, the attacker performs malicious actions by using the stolen token with the targeted application to impersonate the victim. This attack is a specific method of session hijacking, which is exploiting a valid session token to gain unauthorized access to a target system or information. Other methods to perform a session hijacking are session fixation, cross-site scripting, or compromising a user or server machine and stealing the session token.

CAPEC-117: Interception

An adversary monitors data streams to or from the target for information gathering purposes. This attack may be undertaken to solely gather sensitive information or to support a further attack against the target. This attack pattern can involve sniffing network traffic as well as other types of data streams (e.g. radio). The adversary can attempt to initiate the establishment of a data stream or passively observe the communications as they unfold. In all variants of this attack, the adversary is not the intended recipient of the data stream. In contrast to other means of gathering information (e.g., targeting data leaks), the adversary must actively position themself so as to observe explicit data channels (e.g. network traffic) and read the content. However, this attack differs from a Adversary-In-the-Middle (CAPEC-94) attack, as the adversary does not alter the content of the communications nor forward data to the intended recipient.

CAPEC-383: Harvesting Information via API Event Monitoring

An adversary hosts an event within an application framework and then monitors the data exchanged during the course of the event for the purpose of harvesting any important data leaked during the transactions. One example could be harvesting lists of usernames or userIDs for the purpose of sending spam messages to those users. One example of this type of attack involves the adversary creating an event within the sub-application. Assume the adversary hosts a "virtual sale" of rare items. As other users enter the event, the attacker records via AiTM (CAPEC-94) proxy the user_ids and usernames of everyone who attends. The adversary would then be able to spam those users within the application using an automated script.

CAPEC-477: Signature Spoofing by Mixing Signed and Unsigned Content

An attacker exploits the underlying complexity of a data structure that allows for both signed and unsigned content, to cause unsigned data to be processed as though it were signed data.

CAPEC-65: Sniff Application Code

An adversary passively sniffs network communications and captures application code bound for an authorized client. Once obtained, they can use it as-is, or through reverse-engineering glean sensitive information or exploit the trust relationship between the client and server. Such code may belong to a dynamic update to the client, a patch being applied to a client component or any such interaction where the client is authorized to communicate with the server.

Back to CWE stats page