CWE-489
Active Debug Code
The product is released with debugging code still enabled or active.
CVE-2024-21827 (GCVE-0-2024-21827)
Vulnerability from cvelistv5 – Published: 2024-06-25 14:01 – Updated: 2025-11-04 17:14- CWE-489 - Leftover Debug Code
| Vendor | Product | Version | |
|---|---|---|---|
| Tp-Link | ER7206 Omada Gigabit VPN Router |
Affected:
1.4.1 Build 20240117 Rel.57421
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tp-link:er7206:1.4.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "er7206",
"vendor": "tp-link",
"versions": [
{
"status": "affected",
"version": "1.4.1"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-21827",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-28T03:55:30.451509Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T13:04:19.580Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-04T17:14:15.827Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1947",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1947"
},
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-1947"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "ER7206 Omada Gigabit VPN Router",
"vendor": "Tp-Link",
"versions": [
{
"status": "affected",
"version": "1.4.1 Build 20240117 Rel.57421"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Discovered by the Vulnerability Discovery and Research team of Cisco Talos."
}
],
"descriptions": [
{
"lang": "en",
"value": "A leftover debug code vulnerability exists in the cli_server debug functionality of Tp-Link ER7206 Omada Gigabit VPN Router 1.4.1 Build 20240117 Rel.57421. A specially crafted series of network requests can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "CWE-489: Leftover Debug Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-25T17:00:06.591Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1947",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1947"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2024-21827",
"datePublished": "2024-06-25T14:01:26.644Z",
"dateReserved": "2024-02-14T16:25:03.146Z",
"dateUpdated": "2025-11-04T17:14:15.827Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-28008 (GCVE-0-2024-28008)
Vulnerability from cvelistv5 – Published: 2024-03-28 00:52 – Updated: 2025-01-14 03:52- CWE-489 - Active Debug Code
| Vendor | Product | Version | |
|---|---|---|---|
| NEC Corporation | WG1800HP4 |
Affected:
all versions
|
|
| NEC Corporation | WG1200HS3 |
Affected:
all versions
|
|
| NEC Corporation | WG1900HP2 |
Affected:
all versions
|
|
| NEC Corporation | WG1200HP3 |
Affected:
all versions
|
|
| NEC Corporation | WG1800HP3 |
Affected:
all versions
|
|
| NEC Corporation | WG1200HS2 |
Affected:
all versions
|
|
| NEC Corporation | WG1900HP |
Affected:
all versions
|
|
| NEC Corporation | WG1200HP2 |
Affected:
all versions
|
|
| NEC Corporation | W1200EX(-MS) |
Affected:
all versions
|
|
| NEC Corporation | WG1200HS |
Affected:
all versions
|
|
| NEC Corporation | WG1200HP |
Affected:
all versions
|
|
| NEC Corporation | WF300HP2 |
Affected:
all versions
|
|
| NEC Corporation | W300P |
Affected:
all versions
|
|
| NEC Corporation | WF800HP |
Affected:
all versions
|
|
| NEC Corporation | WR8165N |
Affected:
all versions
|
|
| NEC Corporation | WG2200HP |
Affected:
all versions
|
|
| NEC Corporation | WF1200HP2 |
Affected:
all versions
|
|
| NEC Corporation | WG1800HP2 |
Affected:
all versions
|
|
| NEC Corporation | WF1200HP |
Affected:
all versions
|
|
| NEC Corporation | WG600HP |
Affected:
all versions
|
|
| NEC Corporation | WG300HP |
Affected:
all versions
|
|
| NEC Corporation | WF300HP |
Affected:
all versions
|
|
| NEC Corporation | WG1800HP |
Affected:
all versions
|
|
| NEC Corporation | WG1400HP |
Affected:
all versions
|
|
| NEC Corporation | WR8175N |
Affected:
all versions
|
|
| NEC Corporation | WR9300N |
Affected:
all versions
|
|
| NEC Corporation | WR8750N |
Affected:
all versions
|
|
| NEC Corporation | WR8160N |
Affected:
all versions
|
|
| NEC Corporation | WR9500N |
Affected:
all versions
|
|
| NEC Corporation | WR8600N |
Affected:
all versions
|
|
| NEC Corporation | WR8370N |
Affected:
all versions
|
|
| NEC Corporation | WR8170N |
Affected:
all versions
|
|
| NEC Corporation | WR8700N |
Affected:
all versions
|
|
| NEC Corporation | WR8300N |
Affected:
all versions
|
|
| NEC Corporation | WR8150N |
Affected:
all versions
|
|
| NEC Corporation | WR4100N |
Affected:
all versions
|
|
| NEC Corporation | WR4500N |
Affected:
all versions
|
|
| NEC Corporation | WR8100N |
Affected:
all versions
|
|
| NEC Corporation | WR8500N |
Affected:
all versions
|
|
| NEC Corporation | CR2500P |
Affected:
all versions
|
|
| NEC Corporation | WR8400N |
Affected:
all versions
|
|
| NEC Corporation | WR8200N |
Affected:
all versions
|
|
| NEC Corporation | WR1200H |
Affected:
all versions
|
|
| NEC Corporation | WR7870S |
Affected:
all versions
|
|
| NEC Corporation | WR6670S |
Affected:
all versions
|
|
| NEC Corporation | WR7850S |
Affected:
all versions
|
|
| NEC Corporation | WR6650S |
Affected:
all versions
|
|
| NEC Corporation | WR6600H |
Affected:
all versions
|
|
| NEC Corporation | WR7800H |
Affected:
all versions
|
|
| NEC Corporation | WM3400RN |
Affected:
all versions
|
|
| NEC Corporation | WM3450RN |
Affected:
all versions
|
|
| NEC Corporation | WM3500R |
Affected:
all versions
|
|
| NEC Corporation | WM3600R |
Affected:
all versions
|
|
| NEC Corporation | WM3800R |
Affected:
all versions
|
|
| NEC Corporation | WR8166N |
Affected:
all versions
|
|
| NEC Corporation | MR01LN |
Affected:
all versions
|
|
| NEC Corporation | MR02LN |
Affected:
all versions
|
|
| NEC Corporation | WG1810HP(JE) |
Affected:
all versions
|
|
| NEC Corporation | WG1810HP(MF) |
Affected:
all versions
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:nec:aterm_wr8700n_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_w1200ex-ms_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wf300hp2_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wf300hp_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wf800hp_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg1200hp_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg1200hs2_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg1200hs_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg1400hp_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg1800hp2_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:h:nec:aterm_wg1800hp3:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg1800hp_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg1900hp_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg2200hp_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg300hp_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg600hp_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wr8165n_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wr8170n_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wr8175n_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wr8370n_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wr8600n_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wr8750n_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wr9300n_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wr9500n_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg1200hp3_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg1900hp2_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg1200hs3_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:nec:aterm_wg1800hp4_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "aterm_wg1800hp4_firmware",
"vendor": "nec",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-28008",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-02T13:05:24.151876Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-29T16:41:51.065Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:48:47.634Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://jpn.nec.com/security-info/secinfo/nv24-001_en.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "WG1800HP4",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1200HS3",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1900HP2",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1200HP3",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1800HP3",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1200HS2",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1900HP",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1200HP2",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "W1200EX(-MS)",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1200HS",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1200HP",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WF300HP2",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "W300P",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WF800HP",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8165N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG2200HP",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WF1200HP2",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1800HP2",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WF1200HP",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG600HP",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG300HP",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WF300HP",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1800HP",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1400HP",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8175N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR9300N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8750N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8160N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR9500N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8600N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8370N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8170N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8700N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8300N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8150N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR4100N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR4500N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8100N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8500N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "CR2500P",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8400N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8200N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR1200H",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR7870S",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR6670S",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR7850S",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR6650S",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR6600H",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR7800H",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WM3400RN",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WM3450RN",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WM3500R",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WM3600R",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WM3800R",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WR8166N",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "MR01LN",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "MR02LN",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1810HP(JE)",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1810HP(MF)",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Katsuhiko Sato and Ryo Kashiro of 00One, Inc. and Takayuki Sasaki and Katsunari Yoshioka of Yokohama National University."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Active Debug Code in NEC Corporation Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX(-MS), WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP, WG1800HP, WG1400HP, WR8175N, WR9300N, WR8750N, WR8160N, WR9500N, WR8600N, WR8370N, WR8170N, WR8700N, WR8300N, WR8150N, WR4100N, WR4500N, WR8100N, WR8500N, CR2500P, WR8400N, WR8200N, WR1200H, WR7870S, WR6670S, WR7850S, WR6650S, WR6600H, WR7800H, WM3400RN, WM3450RN, WM3500R, WM3600R, WM3800R, WR8166N, MR01LN MR02LN, WG1810HP(JE) and WG1810HP(MF) all versions allows a attacker to execute an arbitrary OS command via the internet."
}
],
"value": "Active Debug Code in NEC Corporation Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX(-MS), WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP, WG1800HP, WG1400HP, WR8175N, WR9300N, WR8750N, WR8160N, WR9500N, WR8600N, WR8370N, WR8170N, WR8700N, WR8300N, WR8150N, WR4100N, WR4500N, WR8100N, WR8500N, CR2500P, WR8400N, WR8200N, WR1200H, WR7870S, WR6670S, WR7850S, WR6650S, WR6600H, WR7800H, WM3400RN, WM3450RN, WM3500R, WM3600R, WM3800R, WR8166N, MR01LN MR02LN, WG1810HP(JE) and WG1810HP(MF) all versions allows a attacker to execute an arbitrary OS command via the internet."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "CWE-489: Active Debug Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T03:52:42.613Z",
"orgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
"shortName": "NEC"
},
"references": [
{
"url": "https://jpn.nec.com/security-info/secinfo/nv24-001_en.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
"assignerShortName": "NEC",
"cveId": "CVE-2024-28008",
"datePublished": "2024-03-28T00:52:51.641Z",
"dateReserved": "2024-02-29T08:40:07.582Z",
"dateUpdated": "2025-01-14T03:52:42.613Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-29075 (GCVE-0-2024-29075)
Vulnerability from cvelistv5 – Published: 2024-11-12 05:30 – Updated: 2024-11-12 14:41- CWE-489 - Active debug code
| URL | Tags |
|---|---|
| https://jvn.jp/en/vu/JVNVU90676195/ |
| Vendor | Product | Version | |
|---|---|---|---|
| SoftBank Corp. | Mesh Wi-Fi router RP562B |
Affected:
firmware version v1.0.2 and earlier
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-29075",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T14:41:08.506744Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T14:41:17.749Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Mesh Wi-Fi router RP562B",
"vendor": "SoftBank Corp.",
"versions": [
{
"status": "affected",
"version": "firmware version v1.0.2 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Active debug code vulnerability exists in Mesh Wi-Fi router RP562B firmware version v1.0.2 and earlier. If this vulnerability is exploited, a network-adjacent authenticated attacker may obtain or alter the settings of the device ."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "Active debug code",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T05:30:10.952Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://jvn.jp/en/vu/JVNVU90676195/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2024-29075",
"datePublished": "2024-11-12T05:30:10.952Z",
"dateReserved": "2024-10-30T23:12:15.239Z",
"dateUpdated": "2024-11-12T14:41:17.749Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30219 (GCVE-0-2024-30219)
Vulnerability from cvelistv5 – Published: 2024-04-15 10:42 – Updated: 2025-08-27 21:02- CWE-489 - Active debug code
| URL | Tags |
|---|---|
| https://jvn.jp/en/vu/JVNVU91975826/ |
| Vendor | Product | Version | |
|---|---|---|---|
| PLANEX COMMUNICATIONS INC. | MZK-MF300N |
Affected:
all firmware versions
|
|
| PLANEX COMMUNICATIONS INC. | MZK-MF300HP2 |
Affected:
firmware versions 1.18 and earlier
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:planex:mzk-mf300n_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "mzk-mf300n_firmware",
"vendor": "planex",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30219",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-27T02:15:27.805566Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T21:02:07.280Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:25:03.416Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU91975826/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "MZK-MF300N",
"vendor": "PLANEX COMMUNICATIONS INC.",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"product": "MZK-MF300HP2",
"vendor": "PLANEX COMMUNICATIONS INC.",
"versions": [
{
"status": "affected",
"version": "firmware versions 1.18 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Active debug code vulnerability exists in PLANEX COMMUNICATIONS wireless LAN routers. If a logged-in user who knows how to use the debug function accesses the device\u0027s management page, an unintended operation may be performed. Note that MZK-MF300N is no longer supported, therefore the update for this product is not provided."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "Active debug code",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T07:21:48.696Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://jvn.jp/en/vu/JVNVU91975826/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2024-30219",
"datePublished": "2024-04-15T10:42:30.673Z",
"dateReserved": "2024-03-26T06:29:22.984Z",
"dateUpdated": "2025-08-27T21:02:07.280Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32047 (GCVE-0-2024-32047)
Vulnerability from cvelistv5 – Published: 2024-05-15 19:36 – Updated: 2024-08-02 02:06| Vendor | Product | Version | |
|---|---|---|---|
| CyberPower | PowerPanel business |
Affected:
0 , < 4.9.0
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:cyberpower:powerpanel_business:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "powerpanel_business",
"vendor": "cyberpower",
"versions": [
{
"lessThan": "4.9.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32047",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-16T18:13:39.475129Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:50:55.367Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:06:43.550Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-01"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.cyberpower.com/global/en/product/sku/powerpanel_business_for_windows#downloads"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerPanel business",
"vendor": "CyberPower",
"versions": [
{
"lessThan": "4.9.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Amir Preminger and Noam Moshe of Claroty Team82 Research reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Hard-coded credentials for the \nCyberPower PowerPanel test server can be found in the \nproduction code. This might result in an attacker gaining access to the \ntesting or production server.\n\n\u003cbr\u003e"
}
],
"value": "Hard-coded credentials for the \nCyberPower PowerPanel test server can be found in the \nproduction code. This might result in an attacker gaining access to the \ntesting or production server."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "CWE-489",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T19:36:41.936Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-01"
},
{
"url": "https://www.cyberpower.com/global/en/product/sku/powerpanel_business_for_windows#downloads"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\u003cp\u003eCyberPower has released a new version (v4.10.1 or later version) of PowerPanel business that fixes these vulnerabilities.\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.cyberpower.com/global/en/product/sku/powerpanel_business_for_windows#downloads\"\u003ehttps://www.cyberpower.com/global/en/product/sku/powerpanel_business_for_windows#downloads\u003c/a\u003e\u003cbr\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "CyberPower has released a new version (v4.10.1 or later version) of PowerPanel business that fixes these vulnerabilities.\n\n\n https://www.cyberpower.com/global/en/product/sku/powerpanel_business_for_windows#downloads"
}
],
"source": {
"advisory": "ICSA-24-123-01",
"discovery": "EXTERNAL"
},
"title": "CyberPower PowerPanel business Active Debug Code",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-32047",
"datePublished": "2024-05-15T19:36:41.936Z",
"dateReserved": "2024-04-29T16:47:22.349Z",
"dateUpdated": "2024-08-02T02:06:43.550Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41999 (GCVE-0-2024-41999)
Vulnerability from cvelistv5 – Published: 2024-09-30 07:50 – Updated: 2024-09-30 16:45- CWE-489 - Active debug code
| Vendor | Product | Version | |
|---|---|---|---|
| TECHNO SUPPORT COMPANY | Smart-tab Android app |
Affected:
installed April 2023 or earlier
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:android_app:smart_tab:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "smart_tab",
"vendor": "android_app",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-41999",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-30T16:41:52.476692Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T16:45:01.184Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Smart-tab Android app",
"vendor": "TECHNO SUPPORT COMPANY",
"versions": [
{
"status": "affected",
"version": "installed April 2023 or earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Smart-tab Android app installed April 2023 or earlier contains an active debug code vulnerability. If this vulnerability is exploited, an attacker with physical access to the device may exploit the debug function to gain access to the OS functions, escalate the privilege, change the device\u0027s settings, or spoof devices in other rooms."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "Active debug code",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T07:50:34.536Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://tsc-soft.co.jp/smart-tab/"
},
{
"url": "https://jvn.jp/en/jp/JVN42445661/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2024-41999",
"datePublished": "2024-09-30T07:50:34.536Z",
"dateReserved": "2024-09-18T23:09:30.952Z",
"dateUpdated": "2024-09-30T16:45:01.184Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46873 (GCVE-0-2024-46873)
Vulnerability from cvelistv5 – Published: 2024-12-23 00:17 – Updated: 2024-12-24 00:39- CWE-489 - Active debug code
| Vendor | Product | Version | |
|---|---|---|---|
| Sharp Corporation | home 5G HR02 |
Affected:
S5.82.00 and earlier
|
|
| Sharp Corporation | Wi-Fi STATION SH-52B |
Affected:
S3.87.11 and earlier
|
|
| Sharp Corporation | Wi-Fi STATION SH-54C |
Affected:
S6.60.00 and earlier
|
|
| Sharp Corporation | Wi-Fi STATION SH-05L |
Affected:
01.00.C0 and earlier
|
|
| Sharp Corporation | PocketWifi 809SH |
Affected:
01.00.B9 and earlier
|
|
| Sharp Corporation | Speed Wi-Fi NEXT W07 |
Affected:
02.00.48 and earlier
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-46873",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-24T00:35:52.238750Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-24T00:39:44.951Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "home 5G HR02",
"vendor": "Sharp Corporation",
"versions": [
{
"status": "affected",
"version": "S5.82.00 and earlier"
}
]
},
{
"product": "Wi-Fi STATION SH-52B",
"vendor": "Sharp Corporation",
"versions": [
{
"status": "affected",
"version": "S3.87.11 and earlier"
}
]
},
{
"product": "Wi-Fi STATION SH-54C",
"vendor": "Sharp Corporation",
"versions": [
{
"status": "affected",
"version": "S6.60.00 and earlier"
}
]
},
{
"product": "Wi-Fi STATION SH-05L",
"vendor": "Sharp Corporation",
"versions": [
{
"status": "affected",
"version": "01.00.C0 and earlier"
}
]
},
{
"product": "PocketWifi 809SH",
"vendor": "Sharp Corporation",
"versions": [
{
"status": "affected",
"version": "01.00.B9 and earlier"
}
]
},
{
"product": "Speed Wi-Fi NEXT W07",
"vendor": "Sharp Corporation",
"versions": [
{
"status": "affected",
"version": "02.00.48 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple SHARP routers leave the hidden debug function enabled. An arbitrary OS command may be executed with the root privilege by a remote unauthenticated attacker."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "Active debug code",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-23T00:17:59.216Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://k-tai.sharp.co.jp/support/info/info083.html"
},
{
"url": "https://jvn.jp/en/jp/JVN61635834/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2024-46873",
"datePublished": "2024-12-23T00:17:59.216Z",
"dateReserved": "2024-12-02T06:03:30.029Z",
"dateUpdated": "2024-12-24T00:39:44.951Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-53648 (GCVE-0-2024-53648)
Vulnerability from cvelistv5 – Published: 2025-02-11 10:28 – Updated: 2025-11-11 20:20- CWE-489 - Active Debug Code
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIPROTEC 5 6MD84 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 6MD85 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 6MD85 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 6MD86 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 6MD86 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 6MD89 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 6MU85 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7KE85 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7KE85 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SA82 (CP100) |
Affected:
0 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SA82 (CP150) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SA86 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SA86 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SA87 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SA87 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SD82 (CP100) |
Affected:
0 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SD82 (CP150) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SD86 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SD86 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SD87 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SD87 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ81 (CP100) |
Affected:
0 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ81 (CP150) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ82 (CP100) |
Affected:
0 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ82 (CP150) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ85 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ85 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ86 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ86 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SK82 (CP100) |
Affected:
0 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SK82 (CP150) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SK85 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SK85 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SL82 (CP100) |
Affected:
0 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SL82 (CP150) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SL86 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SL86 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SL87 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SL87 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SS85 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SS85 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7ST85 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7ST85 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7ST86 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SX82 (CP150) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SX85 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SY82 (CP150) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7UM85 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7UT82 (CP100) |
Affected:
0 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7UT82 (CP150) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7UT85 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7UT85 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7UT86 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7UT86 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7UT87 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7UT87 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7VE85 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7VK87 (CP200) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7VK87 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 7VU85 (CP300) |
Affected:
0 , < V9.90
(custom)
|
|
| Siemens | SIPROTEC 5 Compact 7SX800 (CP050) |
Affected:
0 , < V9.90
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-53648",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-11T14:35:44.427665Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-11T14:35:58.855Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD84 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD86 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD89 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7KE85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7KE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA86 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA87 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD86 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD87 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ81 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ81 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ86 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL86 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL87 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SS85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SS85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SY82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UM85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT86 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT87 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VK87 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VK87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Compact 7SX800 (CP050)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 6MD89 (CP300) (All versions \u003c V9.90), SIPROTEC 5 6MU85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SA82 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SD82 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SK82 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SL82 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7UM85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7UT82 (CP100) (All versions \u003c V8.90), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7VE85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "CWE-489: Active Debug Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-11T20:20:22.924Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-687955.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-53648",
"datePublished": "2025-02-11T10:28:52.039Z",
"dateReserved": "2024-11-21T13:26:39.692Z",
"dateUpdated": "2025-11-11T20:20:22.924Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-7756 (GCVE-0-2024-7756)
Vulnerability from cvelistv5 – Published: 2024-09-13 17:26 – Updated: 2024-09-16 17:51- CWE-489 - Active Debug Code
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | 10w (Type 82ST, 82SU) Laptop (Lenovo) BIOS |
Affected:
0 , < JSCN28WW
(custom)
|
|
| Lenovo | L390 (type 20NR, 20NS) Laptops (ThinkPad) BIOS |
Affected:
0 , < 1.47
(custom)
|
|
| Lenovo | L390 Yoga (type 20NT, 20NU) Laptops (ThinkPad) BIOS |
Affected:
0 , < 1.47
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:lenovo:thinkpad_l390_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:lenovo:thinkpad_l390_yoga_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "thinkpad_l390_yoga_firmware",
"vendor": "lenovo",
"versions": [
{
"lessThan": "1.47",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:lenovo:10w_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "10w_firmware",
"vendor": "lenovo",
"versions": [
{
"lessThan": "jscn28ww",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7756",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-13T21:04:45.731099Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-16T17:51:12.837Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "10w (Type 82ST, 82SU) Laptop (Lenovo) BIOS",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "JSCN28WW",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "L390 (type 20NR, 20NS) Laptops (ThinkPad) BIOS",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "1.47",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "L390 Yoga (type 20NT, 20NU) Laptops (ThinkPad) BIOS",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "1.47",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Lenovo thanks Warren Togami for reporting this issue."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA potential vulnerability was reported in the ThinkPad L390 Yoga and 10w Notebook that could allow a local attacker to escalate privileges by accessing an embedded UEFI shell. \u003c/span\u003e"
}
],
"value": "A potential vulnerability was reported in the ThinkPad L390 Yoga and 10w Notebook that could allow a local attacker to escalate privileges by accessing an embedded UEFI shell."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "CWE-489: Active Debug Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-13T17:26:58.798Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"url": "https://support.lenovo.com/us/en/product_security/LEN-165524"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update system firmware to the version (or newer) indicated for your model in the advisory:\u0026nbsp;\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.lenovo.com/us/en/product_security/LEN-165524\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-165524\u003c/a\u003e\u003cbr\u003e"
}
],
"value": "Update system firmware to the version (or newer) indicated for your model in the advisory:\u00a0 https://support.lenovo.com/us/en/product_security/LEN-165524"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2024-7756",
"datePublished": "2024-09-13T17:26:58.798Z",
"dateReserved": "2024-08-13T17:13:25.142Z",
"dateUpdated": "2024-09-16T17:51:12.837Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-9643 (GCVE-0-2024-9643)
Vulnerability from cvelistv5 – Published: 2025-02-04 14:47 – Updated: 2025-11-22 01:43| URL | Tags |
|---|---|
| https://vulncheck.com/advisories/four-faith-hard-… | third-party-advisory |
| https://talosintelligence.com/vulnerability_repor… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Four-Faith | F3x36 |
Affected:
2.0.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-9643",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-04T15:51:11.212644Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-04T15:51:15.735Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2023-1752"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "F3x36",
"vendor": "Four-Faith",
"versions": [
{
"status": "affected",
"version": "2.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:four-faith:f3x24:2.0.0:*:*:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Jacob Baines"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Four-Faith\u0026nbsp;F3x36 router using firmware v2.0.0 is vulnerable to authentication bypass due to hard-coded credentials in the administrative web server. An attacker with knowledge of the credentials can gain administrative access via crafted HTTP requests. This issue appears similar to CVE-2023-32645.\u003cbr\u003e"
}
],
"value": "The Four-Faith\u00a0F3x36 router using firmware v2.0.0 is vulnerable to authentication bypass due to hard-coded credentials in the administrative web server. An attacker with knowledge of the credentials can gain administrative access via crafted HTTP requests. This issue appears similar to CVE-2023-32645."
}
],
"impacts": [
{
"capecId": "CAPEC-70",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-70 Try Common or Default Usernames and Passwords"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "CWE-489 Active Debug Code",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-22T01:43:40.757Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://vulncheck.com/advisories/four-faith-hard-coded-creds"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2023-1752"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Four-Faith F3x36 Hidden Debug Credentials",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2024-9643",
"datePublished": "2025-02-04T14:47:40.214Z",
"dateReserved": "2024-10-08T18:08:00.149Z",
"dateUpdated": "2025-11-22T01:43:40.757Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Mitigation
Phases: Build and Compilation, Distribution
Description:
- Remove debug code before deploying the application.
CAPEC-121: Exploit Non-Production Interfaces
An adversary exploits a sample, demonstration, test, or debug interface that is unintentionally enabled on a production system, with the goal of gleaning information or leveraging functionality that would otherwise be unavailable.
CAPEC-661: Root/Jailbreak Detection Evasion via Debugging
An adversary inserts a debugger into the program entry point of a mobile application to modify the application binary, with the goal of evading Root/Jailbreak detection. Mobile device users often Root/Jailbreak their devices in order to gain administrative control over the mobile operating system and/or to install third-party mobile applications that are not provided by authorized application stores (e.g. Google Play Store and Apple App Store). Rooting/Jailbreaking a mobile device also provides users with access to system debuggers and disassemblers, which can be leveraged to exploit applications by dumping the application's memory at runtime in order to remove or bypass signature verification methods. This further allows the adversary to evade Root/Jailbreak detection mechanisms, which can result in execution of administrative commands, obtaining confidential data, impersonating legitimate users of the application, and more.