Search criteria
6 vulnerabilities found for 100ap_device_firmware by brickcom
FKIE_CVE-2013-3689
Vulnerability from fkie_nvd - Published: 2013-10-04 23:55 - Updated: 2025-04-11 00:51
Severity ?
Summary
Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.0.6.16C1 and earlier, do not properly restrict access to configfile.dump, which allow remote attackers to obtain sensitive information (user names, passwords, and configurations) via a get action.
References
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:brickcom:100ap_device_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5B92EEBC-BD88-4F6F-A0F5-9B90F0E80F9C",
"versionEndIncluding": "3.0.6.16c1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:brickcom:fb-100ap:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8793329F-0144-40FB-A2C5-AC5F8E3A2DAF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:brickcom:md-100ap:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7272E6B1-E94B-463E-843B-DCD5448718B5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:brickcom:ob-100ae:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C8DC5FA0-0BD5-41A3-8924-AC775728A763",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:brickcom:osd-040e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2BDD54A2-36B9-4A17-8C2D-A0CCB9CD5379",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:brickcom:wcb-100ap:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6A2CF165-23AA-4C7D-9D8F-3A225CAB3193",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:brickcom:wfb-100ap:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C9DD4683-503D-4F23-A9D3-531A04207E37",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.0.6.16C1 and earlier, do not properly restrict access to configfile.dump, which allow remote attackers to obtain sensitive information (user names, passwords, and configurations) via a get action."
},
{
"lang": "es",
"value": "Brickcom FB-100AP, WCB-100AP, MD-100AP, WFB-100AP, OB-100Ae, OSD-040E, y posiblemente otros modelos de c\u00e1maras con firmware 3.0.6.16C1 y anteriores, no limitan adecuadamente el acceso a configfile.dump, que permite a atacantes remotos obtener informaci\u00f3n sensible (nombres de usuario, contrase\u00f1as y configuraciones) a trav\u00e9s de una acci\u00f3n get."
}
],
"id": "CVE-2013-3689",
"lastModified": "2025-04-11T00:51:21.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2013-10-04T23:55:03.970",
"references": [
{
"source": "cve@mitre.org",
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-264"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2013-3690
Vulnerability from fkie_nvd - Published: 2013-10-01 19:55 - Updated: 2025-04-11 00:51
Severity ?
Summary
Cross-site request forgery (CSRF) vulnerability in cgi-bin/users.cgi in Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.1.0.8 and earlier, allows remote attackers to hijack the authentication of administrators for requests that add users.
References
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:brickcom:100ap_device_firmware:3.1.0.8:*:*:*:*:*:*:*",
"matchCriteriaId": "9C749291-D2A6-41CD-AF03-E0DAE0056FA0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:brickcom:fb-100ap:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8793329F-0144-40FB-A2C5-AC5F8E3A2DAF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:brickcom:md-100ap:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7272E6B1-E94B-463E-843B-DCD5448718B5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:brickcom:ob-100ae:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C8DC5FA0-0BD5-41A3-8924-AC775728A763",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:brickcom:osd-040e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2BDD54A2-36B9-4A17-8C2D-A0CCB9CD5379",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:brickcom:wcb-100ap:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6A2CF165-23AA-4C7D-9D8F-3A225CAB3193",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:brickcom:wfb-100ap:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C9DD4683-503D-4F23-A9D3-531A04207E37",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability in cgi-bin/users.cgi in Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.1.0.8 and earlier, allows remote attackers to hijack the authentication of administrators for requests that add users."
},
{
"lang": "es",
"value": "Vulnerabilidad de CSRF en cgi-bin/users.cgi en Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, y posiblemente otros modelos de c\u00e1mara con firmware 3.1.0.8 y anteriores, permite a atacantes remotos secuestrar la autenticaci\u00f3n de administradores para peticiones que incluyan usuarios."
}
],
"id": "CVE-2013-3690",
"lastModified": "2025-04-11T00:51:21.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
]
},
"published": "2013-10-01T19:55:09.397",
"references": [
{
"source": "cve@mitre.org",
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2013-3689 (GCVE-0-2013-3689)
Vulnerability from cvelistv5 – Published: 2013-10-04 23:00 – Updated: 2024-09-17 03:38
VLAI?
Summary
Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.0.6.16C1 and earlier, do not properly restrict access to configfile.dump, which allow remote attackers to obtain sensitive information (user names, passwords, and configurations) via a get action.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:14:56.820Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20130612 Security Analysis of IP video surveillance cameras",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.0.6.16C1 and earlier, do not properly restrict access to configfile.dump, which allow remote attackers to obtain sensitive information (user names, passwords, and configurations) via a get action."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-10-04T23:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "20130612 Security Analysis of IP video surveillance cameras",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-3689",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.0.6.16C1 and earlier, do not properly restrict access to configfile.dump, which allow remote attackers to obtain sensitive information (user names, passwords, and configurations) via a get action."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20130612 Security Analysis of IP video surveillance cameras",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-3689",
"datePublished": "2013-10-04T23:00:00Z",
"dateReserved": "2013-05-29T00:00:00Z",
"dateUpdated": "2024-09-17T03:38:30.242Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-3690 (GCVE-0-2013-3690)
Vulnerability from cvelistv5 – Published: 2013-10-01 19:00 – Updated: 2024-09-17 04:28
VLAI?
Summary
Cross-site request forgery (CSRF) vulnerability in cgi-bin/users.cgi in Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.1.0.8 and earlier, allows remote attackers to hijack the authentication of administrators for requests that add users.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:14:56.653Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20130612 Security Analysis of IP video surveillance cameras",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability in cgi-bin/users.cgi in Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.1.0.8 and earlier, allows remote attackers to hijack the authentication of administrators for requests that add users."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-10-01T19:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "20130612 Security Analysis of IP video surveillance cameras",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-3690",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site request forgery (CSRF) vulnerability in cgi-bin/users.cgi in Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.1.0.8 and earlier, allows remote attackers to hijack the authentication of administrators for requests that add users."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20130612 Security Analysis of IP video surveillance cameras",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-3690",
"datePublished": "2013-10-01T19:00:00Z",
"dateReserved": "2013-05-29T00:00:00Z",
"dateUpdated": "2024-09-17T04:28:59.577Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-3689 (GCVE-0-2013-3689)
Vulnerability from nvd – Published: 2013-10-04 23:00 – Updated: 2024-09-17 03:38
VLAI?
Summary
Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.0.6.16C1 and earlier, do not properly restrict access to configfile.dump, which allow remote attackers to obtain sensitive information (user names, passwords, and configurations) via a get action.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:14:56.820Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20130612 Security Analysis of IP video surveillance cameras",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.0.6.16C1 and earlier, do not properly restrict access to configfile.dump, which allow remote attackers to obtain sensitive information (user names, passwords, and configurations) via a get action."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-10-04T23:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "20130612 Security Analysis of IP video surveillance cameras",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-3689",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.0.6.16C1 and earlier, do not properly restrict access to configfile.dump, which allow remote attackers to obtain sensitive information (user names, passwords, and configurations) via a get action."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20130612 Security Analysis of IP video surveillance cameras",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-3689",
"datePublished": "2013-10-04T23:00:00Z",
"dateReserved": "2013-05-29T00:00:00Z",
"dateUpdated": "2024-09-17T03:38:30.242Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-3690 (GCVE-0-2013-3690)
Vulnerability from nvd – Published: 2013-10-01 19:00 – Updated: 2024-09-17 04:28
VLAI?
Summary
Cross-site request forgery (CSRF) vulnerability in cgi-bin/users.cgi in Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.1.0.8 and earlier, allows remote attackers to hijack the authentication of administrators for requests that add users.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:14:56.653Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20130612 Security Analysis of IP video surveillance cameras",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability in cgi-bin/users.cgi in Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.1.0.8 and earlier, allows remote attackers to hijack the authentication of administrators for requests that add users."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-10-01T19:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "20130612 Security Analysis of IP video surveillance cameras",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-3690",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site request forgery (CSRF) vulnerability in cgi-bin/users.cgi in Brickcom FB-100Ap, WCB-100Ap, MD-100Ap, WFB-100Ap, OB-100Ae, OSD-040E, and possibly other camera models with firmware 3.1.0.8 and earlier, allows remote attackers to hijack the authentication of administrators for requests that add users."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20130612 Security Analysis of IP video surveillance cameras",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2013/Jun/84"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-3690",
"datePublished": "2013-10-01T19:00:00Z",
"dateReserved": "2013-05-29T00:00:00Z",
"dateUpdated": "2024-09-17T04:28:59.577Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}