Search criteria

2 vulnerabilities found for 1756-EN2F/C by Rockwell Automation

CVE-2025-7353 (GCVE-0-2025-7353)

Vulnerability from cvelistv5 – Published: 2025-08-14 13:23 – Updated: 2025-08-15 03:55
VLAI?
Title
Rockwell Automation ControlLogix® Ethernet Remote Code Execution Vulnerability
Summary
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.
CWE
  • CWE-1188 - Initialization of a Resource with an Insecure Default
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7353",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-14T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-15T03:55:58.371Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "1756-EN2T/D",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.004 or below"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "1756-EN2F/C",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.004 or below"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "1756-EN2TR/C",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.004 or below"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "1756-EN3TR/B",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.004 or below"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "1756-EN2TP/A",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.004 or below"
            }
          ]
        }
      ],
      "datePublic": "2025-08-14T13:11:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix\u00ae Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow. \u0026nbsp;\u003c/p\u003e\u003cbr\u003e"
            }
          ],
          "value": "A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix\u00ae Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188: Initialization of a Resource with an Insecure Default",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-14T13:49:37.413Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1732.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e12.001 and later\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "12.001 and later"
        }
      ],
      "source": {
        "advisory": "SD1732",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation ControlLogix\u00ae Ethernet Remote Code Execution Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-7353",
    "datePublished": "2025-08-14T13:23:26.940Z",
    "dateReserved": "2025-07-08T12:24:08.365Z",
    "dateUpdated": "2025-08-15T03:55:58.371Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7353 (GCVE-0-2025-7353)

Vulnerability from nvd – Published: 2025-08-14 13:23 – Updated: 2025-08-15 03:55
VLAI?
Title
Rockwell Automation ControlLogix® Ethernet Remote Code Execution Vulnerability
Summary
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.
CWE
  • CWE-1188 - Initialization of a Resource with an Insecure Default
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7353",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-14T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-15T03:55:58.371Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "1756-EN2T/D",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.004 or below"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "1756-EN2F/C",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.004 or below"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "1756-EN2TR/C",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.004 or below"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "1756-EN3TR/B",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.004 or below"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "1756-EN2TP/A",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.004 or below"
            }
          ]
        }
      ],
      "datePublic": "2025-08-14T13:11:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix\u00ae Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow. \u0026nbsp;\u003c/p\u003e\u003cbr\u003e"
            }
          ],
          "value": "A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix\u00ae Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188: Initialization of a Resource with an Insecure Default",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-14T13:49:37.413Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1732.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e12.001 and later\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "12.001 and later"
        }
      ],
      "source": {
        "advisory": "SD1732",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation ControlLogix\u00ae Ethernet Remote Code Execution Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-7353",
    "datePublished": "2025-08-14T13:23:26.940Z",
    "dateReserved": "2025-07-08T12:24:08.365Z",
    "dateUpdated": "2025-08-15T03:55:58.371Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}