cve-2024-6242
Vulnerability from cvelistv5
Published
2024-08-01 15:15
Modified
2024-08-01 18:01
Severity ?
EPSS score ?
Summary
Rockwell Automation Chassis Restrictions Bypass Vulnerability in Select Logix Devices
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-6242", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-01T18:00:51.414361Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-01T18:01:01.646Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ControlLogix\u00ae 5580 (1756-L8z)", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "V28" } ] }, { "defaultStatus": "unaffected", "product": "GuardLogix\u00ae 5580 (1756-L8zS)", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "V31" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN4TR", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "V2" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Series A/B/C" ], "product": "1756-EN2T", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v5.007(unsigned)/v5.027(signed)" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Series A/B" ], "product": "1756-EN2F", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v5.007(unsigned)/v5.027(signed)" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Series A/B" ], "product": "1756-EN2TR", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v5.007(unsigned)/v5.027(signed)" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Series B" ], "product": "1756-EN3TR", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v5.007(unsigned)/v5.027(signed)" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Series D" ], "product": "1756-EN2T", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "1756-EN2T/D: V10.006" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2F", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "1756-EN2F/C: V10.009" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Series C" ], "product": "1756-EN2TR", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "1756-EN2TR/C: V10.007" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Series B" ], "product": "1756-EN3TR", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "1756-EN3TR/B: V10.007" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Series A" ], "product": "1756-EN2TP", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "1756-EN2TP/A: V10.020" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Claroty reported this vulnerability." } ], "datePublic": "2024-08-01T13:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA vulnerability exists in Rockwell Automation affected products that allows a threat actor to bypass the Trusted\u00ae Slot feature in a ControlLogix\u00ae controller. If exploited on any affected module in a 1756 chassis, a threat actor could potentially execute CIP commands that modify user projects and/or device configuration on a Logix controller in the chassis. \u0026nbsp;\u003c/span\u003e" } ], "value": "A vulnerability exists in Rockwell Automation affected products that allows a threat actor to bypass the Trusted\u00ae Slot feature in a ControlLogix\u00ae controller. If exploited on any affected module in a 1756 chassis, a threat actor could potentially execute CIP commands that modify user projects and/or device configuration on a Logix controller in the chassis." } ], "impacts": [ { "capecId": "CAPEC-216", "descriptions": [ { "lang": "en", "value": "CAPEC-216 Communication Channel Manipulation" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "PRESENT", "attackVector": "NETWORK", "baseScore": 7.3, "baseSeverity": "HIGH", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "HIGH", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "LOW", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-420", "description": "CWE-420: Unprotected Alternate Channel", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-01T15:15:32.220Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1682.html" } ], "source": { "advisory": "SD1682", "discovery": "EXTERNAL" }, "title": "Rockwell Automation Chassis Restrictions Bypass Vulnerability in Select Logix Devices", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\n\n\u003c/p\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eAffected Product \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eFirst Known in Firmware Revision \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eCorrected in Firmware Revision \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eControlLogix\u00ae 5580 (1756-L8z) \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eV28 \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eV32.016, V33.015, V34.014, \u0026nbsp;\u003cbr\u003eV35.011 and later \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eGuardLogix\u00ae 5580 (1756-L8zS) \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eV31 \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eV32.016, V33.015, V34.014, \u0026nbsp;\u003cbr\u003eV35.011 and later \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003e1756-EN4TR \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eV2 \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eV5.001 and later \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003e1756-EN2T, Series A/B/C \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e1756-EN2F, Series A/B \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e1756-EN2TR, Series A/B \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e1756-EN3TR, Series B \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003ev5.007(unsigned)/v5.027(signed) \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eNo fix is available for Series A/B/C. Users can upgrade to Series D to remediate this vulnerability \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003e1756-EN2T, Series D \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e1756-EN2F, Series C \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e1756-EN2TR, Series C \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e1756-EN3TR, Series B \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e1756-EN2TP, Series A \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003e1756-EN2T/D: V10.006 \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e1756-EN2F/C: V10.009 \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e1756-EN2TR/C: V10.007 \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e1756-EN3TR/B: V10.007 \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e1756-EN2TP/A: V10.020 \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eV12.001 and later \u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\n\n\u003cbr\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003e\n\n\u003c/p\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUsers using the affected firmware and who are not able to upgrade to one of the corrected versions are encouraged to apply the following mitigation and security best practices, where possible.\u202f\u003c/span\u003e\u202f\u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eLimit the allowed CIP commands on controllers by setting the mode switch to the RUN position. \u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u0026nbsp;\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e\u003c/div\u003e\u003cp\u003e\u003c/p\u003e" } ], "value": "Affected Product \n\n\n\n\n\nFirst Known in Firmware Revision \n\n\n\n\n\nCorrected in Firmware Revision \n\n\n\n\n\nControlLogix\u00ae 5580 (1756-L8z) \n\n\n\n\n\nV28 \n\n\n\n\n\nV32.016, V33.015, V34.014, \u00a0\nV35.011 and later \n\n\n\n\u00a0\n\n\n\n\n\nGuardLogix\u00ae 5580 (1756-L8zS) \n\n\n\n\n\nV31 \n\n\n\n\n\nV32.016, V33.015, V34.014, \u00a0\nV35.011 and later \n\n\n\n\n\n1756-EN4TR \n\n\n\n\n\nV2 \n\n\n\n\n\nV5.001 and later \n\n\n\n\n\n1756-EN2T, Series A/B/C \n\n\n\n1756-EN2F, Series A/B \n\n\n\n1756-EN2TR, Series A/B \n\n\n\n1756-EN3TR, Series B \n\n\n\n\n\nv5.007(unsigned)/v5.027(signed) \n\n\n\n\n\nNo fix is available for Series A/B/C. Users can upgrade to Series D to remediate this vulnerability \n\n\n\n\n\n1756-EN2T, Series D \n\n\n\n1756-EN2F, Series C \n\n\n\n1756-EN2TR, Series C \n\n\n\n1756-EN3TR, Series B \n\n\n\n1756-EN2TP, Series A \n\n\n\n\n\n1756-EN2T/D: V10.006 \n\n\n\n1756-EN2F/C: V10.009 \n\n\n\n1756-EN2TR/C: V10.007 \n\n\n\n1756-EN3TR/B: V10.007 \n\n\n\n1756-EN2TP/A: V10.020 \n\n\n\n\n\nV12.001 and later \n\n\n\n\n\n\n\n\n\n\n\n\n\n\nUsers using the affected firmware and who are not able to upgrade to one of the corrected versions are encouraged to apply the following mitigation and security best practices, where possible.\u202f\u202f\u00a0\n\n\n\n * Limit the allowed CIP commands on controllers by setting the mode switch to the RUN position. \n\n\n\n\n\n\n\n\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight" } ], "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2024-6242", "datePublished": "2024-08-01T15:15:32.220Z", "dateReserved": "2024-06-21T12:21:00.689Z", "dateUpdated": "2024-08-01T18:01:01.646Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-8626
Vulnerability from cvelistv5
Published
2024-10-08 16:35
Modified
2024-10-08 17:36
Severity ?
EPSS score ?
Summary
Logix Controllers Vulnerable to Denial-of-Service Vulnerability
References
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "compactlogix_5380_firmware", "vendor": "rockwellautomation", "versions": [ { "lessThan": "33.015", "status": "affected", "version": "33.011", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "compact_guardlogix_5380_firmware", "vendor": "rockwellautomation", "versions": [ { "lessThan": "33.015", "status": "affected", "version": "33.011", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "compactlogix_5480_firmware", "vendor": "rockwellautomation", "versions": [ { "lessThan": "33.015", "status": "affected", "version": "33.011", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "guardlogix_5580_firmware", "vendor": "rockwellautomation", "versions": [ { "lessThan": "33.015", "status": "affected", "version": "33.001", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:rockwellautomation:1756-en4tr_firmware:3.002:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "1756-en4tr_firmware", "vendor": "rockwellautomation", "versions": [ { "status": "affected", "version": "3.002" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-8626", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-08T17:29:59.695076Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-08T17:36:25.719Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CompactLogix 5380 controllers", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v33.011 \u003c" } ] }, { "defaultStatus": "unaffected", "product": "Compact GuardLogix\u00ae 5380 controllers", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v33.011\u003c" } ] }, { "defaultStatus": "unaffected", "product": "CompactLogix 5480 controllers", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v33.011\u003c" } ] }, { "defaultStatus": "unaffected", "product": "GuardLogix 5580 controllers", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v33.011\u003c" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN4TR", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v3.002" } ] } ], "datePublic": "2024-10-08T16:24:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDue to a memory leak, a denial-of-service vulnerability exists in the Rockwell Automation affected products. A malicious actor could exploit this vulnerability by performing multiple actions on certain web pages of the product causing the affected products to become fully unavailable and require a power cycle to recover. \u003c/span\u003e" } ], "value": "Due to a memory leak, a denial-of-service vulnerability exists in the Rockwell Automation affected products. A malicious actor could exploit this vulnerability by performing multiple actions on certain web pages of the product causing the affected products to become fully unavailable and require a power cycle to recover." } ], "impacts": [ { "capecId": "CAPEC-124", "descriptions": [ { "lang": "en", "value": "CAPEC-124 Shared Resource Manipulation" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 8.7, "baseSeverity": "HIGH", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400 Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-08T16:35:04.513Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1706.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003cbr\u003eAffected Product\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eFirst Known in firmware Revision\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCorrected in Firmware Revision\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompactLogix 5380 controllers\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.011 \u0026lt;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd rowspan=\"5\"\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003ev33.015 and later for versions 33\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003ev34.011 and later\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompact GuardLogix\u00ae 5380 controllers\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.011\u0026lt;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompactLogix 5480 controllers\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.011\u0026lt;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eControlLogix 5580 controllers\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.011\u0026lt;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eGuardLogix 5580 controllers\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.011\u0026lt;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e1756-EN4TR\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev3.002\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e4.001 and later\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cbr\u003e\n\n\u003cp\u003eMitigations and Workarounds \u003c/p\u003e\u003cp\u003eCustomers using the affected versions are encouraged to upgrade to corrected firmware versions. We also strongly encourage customers to implement our suggested security best practices to minimize the risk of the vulnerability. \u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u0026nbsp;\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e" } ], "value": "Affected Product\u00a0\n\n\u00a0\n\n\u00a0\n\nFirst Known in firmware Revision\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCorrected in Firmware Revision\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompactLogix 5380 controllers\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.011 \u003c\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n * v33.015 and later for versions 33\n\n\n\n\n\u00a0\n\n\u00a0\n\n * v34.011 and later\n\n\n\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompact GuardLogix\u00ae 5380 controllers\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.011\u003c\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompactLogix 5480 controllers\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.011\u003c\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nControlLogix 5580 controllers\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.011\u003c\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nGuardLogix 5580 controllers\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.011\u003c\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n1756-EN4TR\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv3.002\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n * 4.001 and later\n\n\n\n\n\u00a0\n\n\u00a0\n\n\n\n\nMitigations and Workarounds \n\nCustomers using the affected versions are encouraged to upgrade to corrected firmware versions. We also strongly encourage customers to implement our suggested security best practices to minimize the risk of the vulnerability. \n\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight" } ], "source": { "advisory": "SD1706", "discovery": "EXTERNAL" }, "title": "Logix Controllers Vulnerable to Denial-of-Service Vulnerability", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2024-8626", "datePublished": "2024-10-08T16:35:04.513Z", "dateReserved": "2024-09-09T20:33:30.575Z", "dateUpdated": "2024-10-08T17:36:25.719Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-3493
Vulnerability from cvelistv5
Published
2024-04-15 21:17
Modified
2024-08-12 15:16
Severity ?
EPSS score ?
Summary
Rockwell Automation ControlLogix and GaurdLogix Vulnerable to Major Nonrecoverable Fault Due to Invalid Header Value
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T20:12:07.675Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1666.html" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:35.011:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "guardlogix_5580_firmware", "vendor": "rockwellautomation", "versions": [ { "status": "affected", "version": "35.011" } ] }, { "cpes": [ "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:5.001:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "compactlogix_5380_firmware", "vendor": "rockwellautomation", "versions": [ { "status": "affected", "version": "35.011" } ] }, { "cpes": [ "cpe:2.3:o:rockwellautomation:1756-en4tr_firmware:5.001:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "1756-en4tr_firmware", "vendor": "rockwellautomation", "versions": [ { "status": "affected", "version": "5.001" } ] }, { "cpes": [ "cpe:2.3:o:rockwellautomation:1756-en4tr_firmware:5.001:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "1756-en4tr_firmware", "vendor": "rockwellautomation", "versions": [ { "status": "affected", "version": "5.001" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3493", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-12T15:09:28.736089Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-12T15:16:08.155Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ControlLogix 5580", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v35.011" } ] }, { "defaultStatus": "unaffected", "product": "GuardLogix 5580", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v35.011" } ] }, { "defaultStatus": "unaffected", "product": "CompactLogix 5380", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v5.001" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN4TR", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v5.001" } ] } ], "datePublic": "2024-04-12T01:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA specific malformed fragmented packet type (fragmented packets may be generated automatically by devices that send large amounts of data) can cause a major nonrecoverable fault (MNRF) Rockwell Automation\u0027s ControlLogix 5580, Guard Logix\u0026nbsp;5580,\u0026nbsp;CompactLogix 5380,\u0026nbsp;and 1756-EN4TR. If exploited, the affected product will become unavailable and require a manual restart to recover it. Additionally, an MNRF could result in a loss of view and/or control of connected devices. \u003c/span\u003e\n\n" } ], "value": "\nA specific malformed fragmented packet type (fragmented packets may be generated automatically by devices that send large amounts of data) can cause a major nonrecoverable fault (MNRF) Rockwell Automation\u0027s ControlLogix 5580, Guard Logix\u00a05580,\u00a0CompactLogix 5380,\u00a0and 1756-EN4TR. If exploited, the affected product will become unavailable and require a manual restart to recover it. Additionally, an MNRF could result in a loss of view and/or control of connected devices. \n\n" } ], "impacts": [ { "capecId": "CAPEC-137", "descriptions": [ { "lang": "en", "value": "CAPEC-137 Parameter Injection" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-15T21:29:33.269Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1666.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cp\u003e\n\n\u003c/p\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003cbr\u003eAffected Product\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eFirst Known in Firmware Revision\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCorrected in Firmware Revision\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eControlLogix\u00ae 5580\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eV35.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eV35.013, V36.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eGuardLogix 5580\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eV35.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eV35.013, V36.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompactLogix 5380\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eV35.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eV35.013, V36.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e1756-EN4TR\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eV5.001\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eV6.001\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\n\n\u003cbr\u003e\u003cbr\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003eUsers using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.\u202f\u202f\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u0026nbsp;\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e" } ], "value": "\nAffected Product\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nFirst Known in Firmware Revision\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCorrected in Firmware Revision\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nControlLogix\u00ae 5580\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV35.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV35.013, V36.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nGuardLogix 5580\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV35.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV35.013, V36.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompactLogix 5380\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV35.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV35.013, V36.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n1756-EN4TR\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV5.001\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV6.001\n\n\u00a0\n\n\u00a0\n\nUsers using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.\u202f\u202f\n\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \u00a0\n\n" } ], "source": { "discovery": "INTERNAL" }, "title": "Rockwell Automation ControlLogix and GaurdLogix Vulnerable to Major Nonrecoverable Fault Due to Invalid Header Value", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2024-3493", "datePublished": "2024-04-15T21:17:36.077Z", "dateReserved": "2024-04-08T21:46:38.867Z", "dateUpdated": "2024-08-12T15:16:08.155Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }