Vulnerabilites related to rockwellautomation - 1756-en4trk
cve-2023-3596
Vulnerability from cvelistv5
Published
2023-07-12 12:51
Modified
2024-11-07 16:59
Summary
Where this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages.
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-02T07:01:56.685Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010",
               },
            ],
            title: "CVE Program Container",
         },
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:h:rockwellautomation:1756-en4tr:-:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unaffected",
                  product: "1756-en4tr",
                  vendor: "rockwellautomation",
                  versions: [
                     {
                        lessThanOrEqual: "5.001",
                        status: "affected",
                        version: "0",
                        versionType: "custom",
                     },
                  ],
               },
               {
                  cpes: [
                     "cpe:2.3:h:rockwellautomation:1756-en4trk:-:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unaffected",
                  product: "1756-en4trk",
                  vendor: "rockwellautomation",
                  versions: [
                     {
                        lessThanOrEqual: "5.001",
                        status: "affected",
                        version: "0",
                        versionType: "custom",
                     },
                  ],
               },
               {
                  cpes: [
                     "cpe:2.3:h:rockwellautomation:1756-en4trxt:-:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unaffected",
                  product: "1756-en4trxt",
                  vendor: "rockwellautomation",
                  versions: [
                     {
                        lessThanOrEqual: "5.001",
                        status: "affected",
                        version: "0",
                        versionType: "custom",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2023-3596",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "partial",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-11-07T16:56:23.761081Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-11-07T16:59:33.267Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unaffected",
               product: "1756-EN4TR Series A",
               vendor: "Rockwell Automation",
               versions: [
                  {
                     status: "affected",
                     version: "<=5.001",
                  },
               ],
            },
            {
               defaultStatus: "unaffected",
               product: "1756-EN4TRK Series A",
               vendor: "Rockwell Automation",
               versions: [
                  {
                     status: "affected",
                     version: "<=5.001",
                  },
               ],
            },
            {
               defaultStatus: "unaffected",
               product: "1756-EN4TRXT Series A\t",
               vendor: "Rockwell Automation",
               versions: [
                  {
                     status: "affected",
                     version: "<=5.001",
                  },
               ],
            },
         ],
         datePublic: "2023-07-12T12:00:00.000Z",
         descriptions: [
            {
               lang: "en",
               supportingMedia: [
                  {
                     base64: false,
                     type: "text/html",
                     value: "\n\n<span style=\"background-color: rgb(255, 255, 255);\">Where this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages.</span>\n\n",
                  },
               ],
               value: "\nWhere this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages.\n\n",
            },
         ],
         impacts: [
            {
               capecId: "CAPEC-100",
               descriptions: [
                  {
                     lang: "en",
                     value: "CAPEC-100 Overflow Buffers",
                  },
               ],
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  availabilityImpact: "HIGH",
                  baseScore: 7.5,
                  baseSeverity: "HIGH",
                  confidentialityImpact: "NONE",
                  integrityImpact: "NONE",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  version: "3.1",
               },
               format: "CVSS",
               scenarios: [
                  {
                     lang: "en",
                     value: "GENERAL",
                  },
               ],
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-787",
                     description: "CWE-787 Out-of-bounds Write",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2023-07-12T13:16:21.672Z",
            orgId: "b73dd486-f505-4403-b634-40b078b177f0",
            shortName: "Rockwell",
         },
         references: [
            {
               url: "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010",
            },
         ],
         solutions: [
            {
               lang: "en",
               supportingMedia: [
                  {
                     base64: false,
                     type: "text/html",
                     value: "\n\n<ul><li><strong>Update firmware. </strong>Update EN4* ControlLogix communications modules to firmware revision 5.002.&nbsp;</li><li><strong>Properly segment networks.</strong>&nbsp;Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks. </li><li><strong>Implement detection signatures.</strong>&nbsp;Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices. </li></ul>\n\n<br>",
                  },
               ],
               value: "\n  *  Update firmware. Update EN4* ControlLogix communications modules to firmware revision 5.002. \n  *  Properly segment networks. Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks. \n  *  Implement detection signatures. Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices. \n\n\n\n\n\n",
            },
         ],
         source: {
            discovery: "UNKNOWN",
         },
         title: "Rockwell Automation Allen-Bradley ControlLogix Communication Modules vulnerable to Denial of Service ",
         x_generator: {
            engine: "Vulnogram 0.1.0-dev",
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "b73dd486-f505-4403-b634-40b078b177f0",
      assignerShortName: "Rockwell",
      cveId: "CVE-2023-3596",
      datePublished: "2023-07-12T12:51:19.498Z",
      dateReserved: "2023-07-10T15:34:53.790Z",
      dateUpdated: "2024-11-07T16:59:33.267Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

Vulnerability from fkie_nvd
Published
2023-07-12 13:15
Modified
2024-11-21 08:17
Summary
Where this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages.



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:rockwellautomation:1756-en4tr_firmware:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "DB4EB5E2-9FB4-419E-B23A-458436E61121",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:rockwellautomation:1756-en4tr:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "898EE953-E0EF-4B52-8EA0-41AAD8B5CCF3",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:rockwellautomation:1756-en4trk_firmware:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "AEF09D94-1AE1-4449-8ECA-0A5B1F5019C9",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:rockwellautomation:1756-en4trk:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4BE4EFEA-79D9-4903-8272-49756A014BD4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:rockwellautomation:1756-en4trxt_firmware:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "12EE978F-DECE-4572-93AE-026D3EDC5878",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:rockwellautomation:1756-en4trxt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E45471FA-99BF-4F57-BFC8-224BB9576670",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "\nWhere this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages.\n\n",
      },
   ],
   id: "CVE-2023-3596",
   lastModified: "2024-11-21T08:17:37.873",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 7.5,
               baseSeverity: "HIGH",
               confidentialityImpact: "NONE",
               integrityImpact: "NONE",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 3.6,
            source: "PSIRT@rockwellautomation.com",
            type: "Secondary",
         },
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 7.5,
               baseSeverity: "HIGH",
               confidentialityImpact: "NONE",
               integrityImpact: "NONE",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 3.6,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2023-07-12T13:15:09.947",
   references: [
      {
         source: "PSIRT@rockwellautomation.com",
         tags: [
            "Permissions Required",
            "Vendor Advisory",
         ],
         url: "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Permissions Required",
            "Vendor Advisory",
         ],
         url: "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010",
      },
   ],
   sourceIdentifier: "PSIRT@rockwellautomation.com",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-787",
            },
         ],
         source: "PSIRT@rockwellautomation.com",
         type: "Secondary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-787",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}