Search criteria
6 vulnerabilities found for 2tma310010b0003_firmware by abb
FKIE_CVE-2024-4009
Vulnerability from fkie_nvd - Published: 2024-06-05 18:15 - Updated: 2025-03-27 21:15
Severity ?
9.2 (Critical) - CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Replay Attack
in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| abb | 2tma310010b0001_firmware | * | |
| abb | 2tma310010b0001 | - | |
| abb | 2tma310011b0001_firmware | * | |
| abb | 2tma310011b0001 | - | |
| abb | 2tma310011b0002_firmware | * | |
| abb | 2tma310011b0002 | - | |
| abb | 2tma310010b0003_firmware | * | |
| abb | 2tma310010b0003 | - | |
| abb | 2tma310011b0003_firmware | * | |
| abb | 2tma310011b0003 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abb:2tma310010b0001_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2FB4E951-BB1E-49EF-89E1-5FC528E7C39F",
"versionEndExcluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abb:2tma310010b0001:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5887B6A4-F626-43C0-B660-18E9BCB7573A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abb:2tma310011b0001_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47B72D86-BE3B-4E5E-AF78-D15B7BAAFB07",
"versionEndExcluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abb:2tma310011b0001:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF081477-A638-403C-B964-512AD9D778A1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abb:2tma310011b0002_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BF7134CF-B90B-44C5-9AE9-634AD6390C82",
"versionEndExcluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abb:2tma310011b0002:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2040D08-9289-452C-87A1-0FDE70923797",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abb:2tma310010b0003_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "90A07BBA-AC3C-43A4-87F5-B7873DE0E83E",
"versionEndExcluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abb:2tma310010b0003:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EAB58037-6EC4-4816-B310-2D8000A1FF74",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abb:2tma310011b0003_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9125F6EB-0667-47AD-B2EA-F48FF5FE4D63",
"versionEndExcluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abb:2tma310011b0003:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3D74D97B-D726-445F-9E69-9A613D466629",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Replay Attack\n\nin ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System"
},
{
"lang": "es",
"value": "Replay Attack en ABB, Busch-Jaeger, FTS Display (versi\u00f3n 1.00) y BCU (versi\u00f3n 1.3.0.33) permite al atacante capturar/reproducir telegramas KNX al sistema de bus KNX local"
}
],
"id": "CVE-2024-4009",
"lastModified": "2025-03-27T21:15:49.760",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.5,
"impactScore": 6.0,
"source": "cybersecurity@ch.abb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NO",
"Recovery": "NOT_DEFINED",
"Safety": "NEGLIGIBLE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "GREEN",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:N/R:X/V:D/RE:M/U:Green",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "MODERATE"
},
"source": "cybersecurity@ch.abb.com",
"type": "Secondary"
}
]
},
"published": "2024-06-05T18:15:11.420",
"references": [
{
"source": "cybersecurity@ch.abb.com",
"tags": [
"Vendor Advisory"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"sourceIdentifier": "cybersecurity@ch.abb.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-294"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-294"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-4008
Vulnerability from fkie_nvd - Published: 2024-06-05 18:15 - Updated: 2025-09-17 06:15
Severity ?
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| abb | 2tma310010b0001_firmware | * | |
| abb | 2tma310010b0001 | - | |
| abb | 2tma310011b0001_firmware | * | |
| abb | 2tma310011b0001 | - | |
| abb | 2tma310011b0002_firmware | * | |
| abb | 2tma310011b0002 | - | |
| abb | 2tma310010b0003_firmware | * | |
| abb | 2tma310010b0003 | - | |
| abb | 2tma310011b0003_firmware | * | |
| abb | 2tma310011b0003 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abb:2tma310010b0001_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2FB4E951-BB1E-49EF-89E1-5FC528E7C39F",
"versionEndExcluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abb:2tma310010b0001:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5887B6A4-F626-43C0-B660-18E9BCB7573A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abb:2tma310011b0001_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47B72D86-BE3B-4E5E-AF78-D15B7BAAFB07",
"versionEndExcluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abb:2tma310011b0001:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF081477-A638-403C-B964-512AD9D778A1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abb:2tma310011b0002_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BF7134CF-B90B-44C5-9AE9-634AD6390C82",
"versionEndExcluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abb:2tma310011b0002:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2040D08-9289-452C-87A1-0FDE70923797",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abb:2tma310010b0003_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "90A07BBA-AC3C-43A4-87F5-B7873DE0E83E",
"versionEndExcluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abb:2tma310010b0003:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EAB58037-6EC4-4816-B310-2D8000A1FF74",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abb:2tma310011b0003_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9125F6EB-0667-47AD-B2EA-F48FF5FE4D63",
"versionEndExcluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abb:2tma310011b0003:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3D74D97B-D726-445F-9E69-9A613D466629",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System"
},
{
"lang": "es",
"value": "La fuga de FDSK en ABB, Busch-Jaeger, FTS Display (versi\u00f3n 1.00) y BCU (versi\u00f3n 1.3.0.33) permite al atacante tomar el control mediante el acceso al sistema de bus KNX local"
}
],
"id": "CVE-2024-4008",
"lastModified": "2025-09-17T06:15:33.880",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0,
"source": "cybersecurity@ch.abb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NO",
"Recovery": "NOT_DEFINED",
"Safety": "NEGLIGIBLE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "GREEN",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:N/R:X/V:D/RE:M/U:Green",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "MODERATE"
},
"source": "cybersecurity@ch.abb.com",
"type": "Secondary"
}
]
},
"published": "2024-06-05T18:15:11.113",
"references": [
{
"source": "cybersecurity@ch.abb.com",
"tags": [
"Vendor Advisory"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"sourceIdentifier": "cybersecurity@ch.abb.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-497"
}
],
"source": "cybersecurity@ch.abb.com",
"type": "Secondary"
}
]
}
CVE-2024-4009 (GCVE-0-2024-4009)
Vulnerability from cvelistv5 – Published: 2024-06-05 17:19 – Updated: 2025-03-27 20:31
VLAI?
Title
Replay Attack in KNX Secure Devices
Summary
Replay Attack
in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System
Severity ?
CWE
- CWE-294 - Authentication Bypass by Capture-replay
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ABB, Busch-Jaeger | 2.4! Display 55, SD/U12.55.11-825 |
Affected:
1.00
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4009",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-06T13:52:06.305528Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-294",
"description": "CWE-294 Authentication Bypass by Capture-replay",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-27T20:31:09.386Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.233Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0001/sd-u12-55-11-825",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "2.4! Display 55, SD/U12.55.11-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011B0001/sd-u12-55-1-825",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "2.4! Display 55, SD/SD/U12.55.1-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0003/",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "2.4! Display 63, SD/U12.63.11-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011B0003/rt-u12-86-1-825",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "RoomTouch 4\", RT/U12.86.1-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0004/rt-u12-86-11-825",
"defaultStatus": "unaffected",
"product": "RoomTouch 4\", RT/U12.86.11-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0006/sd-u12-70-11-4015",
"defaultStatus": "unaffected",
"product": "2,4\u0027\u0027 Display 70, SD/U12.70.11-4015",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011B00004/sd-u12-70-1-4015",
"defaultStatus": "unaffected",
"product": "2,4\u0027\u0027 Display 70, SD-U12-70-1-4015",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010W0001/rt-u12-86-11-811",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "RoomTouch 4\", RT/U12.86.11-811",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011W0001/rt-u12-86-1-811",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "RoomTouch 4\", RT-U12-86-1-811",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2CKA006120A0079/ba-u1-0-11",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "BCU KNX, BA-U1.0.11",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.3.0.33",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2CKA006120A0080/ba-u1-0-1",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "BCU KNX, BA-U1.0.1",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.3.0.33",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2CKA006120A0081/ba-u1-0-21",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "BCU KNX, BA-U1.0.21",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.3.0.33",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-06-05T16:16:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eReplay Attack\u003c/span\u003e\n\nin ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System\u0026nbsp;\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Replay Attack\n\nin ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "NOT_DEFINED",
"Safety": "NEGLIGIBLE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "GREEN",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/S:N/AU:N/V:D/RE:M/U:Green",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-05T17:19:07.010Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Replay Attack in KNX Secure Devices",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2024-4009",
"datePublished": "2024-06-05T17:19:07.010Z",
"dateReserved": "2024-04-19T17:09:27.489Z",
"dateUpdated": "2025-03-27T20:31:09.386Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4008 (GCVE-0-2024-4008)
Vulnerability from cvelistv5 – Published: 2024-06-05 17:15 – Updated: 2025-09-17 05:33
VLAI?
Title
FDSK Leak in KNX Secure Devices
Summary
FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System
Severity ?
CWE
- CWE-497 - [LLM] Exposure of Sensitive System Information to an Unauthorized Control Sphere
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ABB, Busch-Jaeger | 2.4! Display 55, SD/U12.55.11-825 |
Affected:
1.00
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4008",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-10T11:08:58.207948Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-10T11:09:06.018Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.325Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0001/sd-u12-55-11-825",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "2.4! Display 55, SD/U12.55.11-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011B0001/sd-u12-55-1-825",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "2.4! Display 55, SD/SD/U12.55.1-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0003/",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "2.4! Display 63, SD/U12.63.11-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011B0003/rt-u12-86-1-825",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "RoomTouch 4\", RT/U12.86.1-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0004/rt-u12-86-11-825",
"defaultStatus": "unaffected",
"product": "RoomTouch 4\", RT/U12.86.11-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0006/sd-u12-70-11-4015",
"defaultStatus": "unaffected",
"product": "2,4\u0027\u0027 Display 70, SD/U12.70.11-4015",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011B00004/sd-u12-70-1-4015",
"defaultStatus": "unaffected",
"product": "2,4\u0027\u0027 Display 70, SD-U12-70-1-4015",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010W0001/rt-u12-86-11-811",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "RoomTouch 4\", RT/U12.86.11-811",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011W0001/rt-u12-86-1-811",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "RoomTouch 4\", RT-U12-86-1-811",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2CKA006120A0079/ba-u1-0-11",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "BCU KNX, BA-U1.0.11",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.3.0.33",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2CKA006120A0080/ba-u1-0-1",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "BCU KNX, BA-U1.0.1",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.3.0.33",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2CKA006120A0081/ba-u1-0-21",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "BCU KNX, BA-U1.0.21",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.3.0.33",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-06-05T16:16:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System\u0026nbsp;"
}
],
"value": "FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "NOT_DEFINED",
"Safety": "NEGLIGIBLE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "GREEN",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/S:N/AU:N/V:D/RE:M/U:Green",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-497",
"description": "CWE-497 [LLM] Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-17T05:33:02.694Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "FDSK Leak in KNX Secure Devices",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2024-4008",
"datePublished": "2024-06-05T17:15:56.523Z",
"dateReserved": "2024-04-19T17:09:06.029Z",
"dateUpdated": "2025-09-17T05:33:02.694Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4009 (GCVE-0-2024-4009)
Vulnerability from nvd – Published: 2024-06-05 17:19 – Updated: 2025-03-27 20:31
VLAI?
Title
Replay Attack in KNX Secure Devices
Summary
Replay Attack
in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System
Severity ?
CWE
- CWE-294 - Authentication Bypass by Capture-replay
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ABB, Busch-Jaeger | 2.4! Display 55, SD/U12.55.11-825 |
Affected:
1.00
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4009",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-06T13:52:06.305528Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-294",
"description": "CWE-294 Authentication Bypass by Capture-replay",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-27T20:31:09.386Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.233Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0001/sd-u12-55-11-825",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "2.4! Display 55, SD/U12.55.11-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011B0001/sd-u12-55-1-825",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "2.4! Display 55, SD/SD/U12.55.1-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0003/",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "2.4! Display 63, SD/U12.63.11-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011B0003/rt-u12-86-1-825",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "RoomTouch 4\", RT/U12.86.1-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0004/rt-u12-86-11-825",
"defaultStatus": "unaffected",
"product": "RoomTouch 4\", RT/U12.86.11-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0006/sd-u12-70-11-4015",
"defaultStatus": "unaffected",
"product": "2,4\u0027\u0027 Display 70, SD/U12.70.11-4015",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011B00004/sd-u12-70-1-4015",
"defaultStatus": "unaffected",
"product": "2,4\u0027\u0027 Display 70, SD-U12-70-1-4015",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010W0001/rt-u12-86-11-811",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "RoomTouch 4\", RT/U12.86.11-811",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011W0001/rt-u12-86-1-811",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "RoomTouch 4\", RT-U12-86-1-811",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2CKA006120A0079/ba-u1-0-11",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "BCU KNX, BA-U1.0.11",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.3.0.33",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2CKA006120A0080/ba-u1-0-1",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "BCU KNX, BA-U1.0.1",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.3.0.33",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2CKA006120A0081/ba-u1-0-21",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "BCU KNX, BA-U1.0.21",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.3.0.33",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-06-05T16:16:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eReplay Attack\u003c/span\u003e\n\nin ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System\u0026nbsp;\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Replay Attack\n\nin ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "NOT_DEFINED",
"Safety": "NEGLIGIBLE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "GREEN",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/S:N/AU:N/V:D/RE:M/U:Green",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-05T17:19:07.010Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Replay Attack in KNX Secure Devices",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2024-4009",
"datePublished": "2024-06-05T17:19:07.010Z",
"dateReserved": "2024-04-19T17:09:27.489Z",
"dateUpdated": "2025-03-27T20:31:09.386Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4008 (GCVE-0-2024-4008)
Vulnerability from nvd – Published: 2024-06-05 17:15 – Updated: 2025-09-17 05:33
VLAI?
Title
FDSK Leak in KNX Secure Devices
Summary
FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System
Severity ?
CWE
- CWE-497 - [LLM] Exposure of Sensitive System Information to an Unauthorized Control Sphere
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ABB, Busch-Jaeger | 2.4! Display 55, SD/U12.55.11-825 |
Affected:
1.00
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4008",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-10T11:08:58.207948Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-10T11:09:06.018Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.325Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0001/sd-u12-55-11-825",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "2.4! Display 55, SD/U12.55.11-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011B0001/sd-u12-55-1-825",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "2.4! Display 55, SD/SD/U12.55.1-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0003/",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "2.4! Display 63, SD/U12.63.11-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011B0003/rt-u12-86-1-825",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "RoomTouch 4\", RT/U12.86.1-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0004/rt-u12-86-11-825",
"defaultStatus": "unaffected",
"product": "RoomTouch 4\", RT/U12.86.11-825",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010B0006/sd-u12-70-11-4015",
"defaultStatus": "unaffected",
"product": "2,4\u0027\u0027 Display 70, SD/U12.70.11-4015",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011B00004/sd-u12-70-1-4015",
"defaultStatus": "unaffected",
"product": "2,4\u0027\u0027 Display 70, SD-U12-70-1-4015",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310010W0001/rt-u12-86-11-811",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "RoomTouch 4\", RT/U12.86.11-811",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2TMA310011W0001/rt-u12-86-1-811",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "RoomTouch 4\", RT-U12-86-1-811",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.00",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2CKA006120A0079/ba-u1-0-11",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "BCU KNX, BA-U1.0.11",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.3.0.33",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2CKA006120A0080/ba-u1-0-1",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "BCU KNX, BA-U1.0.1",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.3.0.33",
"versionType": "custom"
}
]
},
{
"collectionURL": "https://new.abb.com/products/de/2CKA006120A0081/ba-u1-0-21",
"defaultStatus": "unaffected",
"platforms": [
"proprietary"
],
"product": "BCU KNX, BA-U1.0.21",
"vendor": "ABB, Busch-Jaeger",
"versions": [
{
"status": "affected",
"version": "1.3.0.33",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-06-05T16:16:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System\u0026nbsp;"
}
],
"value": "FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "NOT_DEFINED",
"Safety": "NEGLIGIBLE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "GREEN",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/S:N/AU:N/V:D/RE:M/U:Green",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-497",
"description": "CWE-497 [LLM] Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-17T05:33:02.694Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "FDSK Leak in KNX Secure Devices",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2024-4008",
"datePublished": "2024-06-05T17:15:56.523Z",
"dateReserved": "2024-04-19T17:09:06.029Z",
"dateUpdated": "2025-09-17T05:33:02.694Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",