Search criteria
96 vulnerabilities found for AC9 by Tenda
CVE-2025-14286 (GCVE-0-2025-14286)
Vulnerability from nvd – Published: 2025-12-09 01:32 – Updated: 2025-12-09 16:03| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-14286",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-09T14:35:32.257434Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T16:03:13.496Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN11.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Configuration File Handler"
],
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.14_multi"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jiahui2888 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda AC9 15.03.05.14_multi. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/DownloadCfg.jpg of the component Configuration File Handler. This manipulation causes information disclosure. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:W/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "Information Disclosure",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "Improper Access Controls",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T01:32:07.198Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-334874 | Tenda AC9 Configuration File DownloadCfg.jpg information disclosure",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.334874"
},
{
"name": "VDB-334874 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.334874"
},
{
"name": "Submit #702723 | Tenda AC9 V1.0 V15.03.05.14_multi Information Disclosure",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.702723"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN11.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-12-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-12-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-12-08T19:54:43.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9 Configuration File DownloadCfg.jpg information disclosure"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-14286",
"datePublished": "2025-12-09T01:32:07.198Z",
"dateReserved": "2025-12-08T18:49:39.958Z",
"dateUpdated": "2025-12-09T16:03:13.496Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-10443 (GCVE-0-2025-10443)
Vulnerability from nvd – Published: 2025-09-15 11:32 – Updated: 2025-09-15 11:40| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10443",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-15T11:40:27.372112Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T11:40:44.495Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.14"
},
{
"status": "affected",
"version": "15.03.05.18"
}
]
},
{
"product": "AC15",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.14"
},
{
"status": "affected",
"version": "15.03.05.18"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "shiny (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. This vulnerability affects the function formexeCommand of the file /goform/exeCommand. Such manipulation of the argument cmdinput leads to buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Tenda AC9 and AC15 15.03.05.14/15.03.05.18 entdeckt. Dabei betrifft es die Funktion formexeCommand der Datei /goform/exeCommand. Dank Manipulation des Arguments cmdinput mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Die Schwachstelle wurde \u00f6ffentlich offengelegt und k\u00f6nnte ausgenutzt werden."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T11:32:07.435Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-323877 | Tenda AC9/AC15 exeCommand formexeCommand buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.323877"
},
{
"name": "VDB-323877 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.323877"
},
{
"name": "Submit #647840 | Tenda Tenda AC15\u3001AC9 AC15 V1.0BR_V15.03.05.18 AC9 V1.0BR_V15.03.05.14 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.647840"
},
{
"tags": [
"related"
],
"url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC15_AC9_Bof.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC15_AC9_Bof.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-09-14T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-09-14T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-09-14T17:47:30.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9/AC15 exeCommand formexeCommand buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-10443",
"datePublished": "2025-09-15T11:32:07.435Z",
"dateReserved": "2025-09-14T15:42:18.331Z",
"dateUpdated": "2025-09-15T11:40:44.495Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-10442 (GCVE-0-2025-10442)
Vulnerability from nvd – Published: 2025-09-15 11:02 – Updated: 2025-09-15 11:59| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10442",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-15T11:58:44.891161Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T11:59:00.751Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.14"
}
]
},
{
"product": "AC15",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.14"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "shiny (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC9 and AC15 15.03.05.14 gefunden. Dies betrifft die Funktion formexeCommand der Datei /goform/exeCommand. Dank der Manipulation des Arguments cmdinput mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T11:02:06.735Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-323876 | Tenda AC9/AC15 exeCommand formexeCommand os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.323876"
},
{
"name": "VDB-323876 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.323876"
},
{
"name": "Submit #647838 | Tenda Tenda AC9 V1.0BR_V15.03.05.14 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.647838"
},
{
"name": "Submit #647839 | Tenda Tenda AC15 V1.0BR_V15.03.05.18 OS Command Injection (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.647839"
},
{
"tags": [
"related"
],
"url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC9_CJ.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC9_CJ.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-09-14T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-09-14T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-09-14T17:46:07.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9/AC15 exeCommand formexeCommand os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-10442",
"datePublished": "2025-09-15T11:02:06.735Z",
"dateReserved": "2025-09-14T15:40:13.804Z",
"dateUpdated": "2025-09-15T11:59:00.751Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-9731 (GCVE-0-2025-9731)
Vulnerability from nvd – Published: 2025-08-31 13:32 – Updated: 2025-09-02 15:14| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9731",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-02T14:40:47.599793Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-02T15:14:30.872Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/August829/Yu/blob/main/58ead8e7e08bfb0e4.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Administrative Interface"
],
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Yu_Bao (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda AC9 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation causes hard-coded credentials. It is possible to launch the attack on the local host. The attack\u0027s complexity is rated as high. The exploitability is regarded as difficult. The exploit has been publicly disclosed and may be utilized."
},
{
"lang": "de",
"value": "In Tenda AC9 15.03.05.19 wurde eine Schwachstelle gefunden. Dies betrifft einen unbekannten Teil der Datei /etc_ro/shadow der Komponente Administrative Interface. Durch Manipulieren mit unbekannten Daten kann eine hard-coded credentials-Schwachstelle ausgenutzt werden. Der Angriff ist nur lokal m\u00f6glich. Ein Angriff erfordert eine vergleichsweise hohe Komplexit\u00e4t. Die Ausnutzbarkeit gilt als schwierig. Die Schwachstelle wurde \u00f6ffentlich offengelegt und k\u00f6nnte ausgenutzt werden."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 2,
"baseSeverity": "LOW",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 1,
"vectorString": "AV:L/AC:H/Au:S/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-31T13:32:07.821Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-322022 | Tenda AC9 Administrative shadow hard-coded credentials",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.322022"
},
{
"name": "VDB-322022 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.322022"
},
{
"name": "Submit #639748 | Tenda AC9 V15.03.05.19 Hard-coded Credentials",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.639748"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/August829/Yu/blob/main/58ead8e7e08bfb0e4.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-08-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-08-30T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-08-30T16:03:04.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9 Administrative shadow hard-coded credentials"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-9731",
"datePublished": "2025-08-31T13:32:07.821Z",
"dateReserved": "2025-08-30T13:58:00.879Z",
"dateUpdated": "2025-09-02T15:14:30.872Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5900 (GCVE-0-2025-5900)
Vulnerability from nvd – Published: 2025-06-09 22:00 – Updated: 2025-06-10 15:29| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5900",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:21:05.917336Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T15:29:00.898Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolRestoreSet-20adf0aa11858094a25ae21f9b4203da"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.02.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ysnysn0121 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as problematic, was found in Tenda AC9 15.03.02.13. This affects an unknown part. The manipulation leads to cross-site request forgery. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine problematische Schwachstelle in Tenda AC9 15.03.02.13 gefunden. Dabei betrifft es einen unbekannter Codeteil. Durch Beeinflussen mit unbekannten Daten kann eine cross-site request forgery-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "Cross-Site Request Forgery",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T22:00:19.518Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311673 | Tenda AC9 cross-site request forgery",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.311673"
},
{
"name": "VDB-311673 | CTI Indicators (IOB, IOC)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311673"
},
{
"name": "Submit #592198 | Tenda AC9 V1.0 V15.03.02.13 Cross Site Request Forgery",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.592198"
},
{
"name": "Submit #592199 | Tenda AC9 V1.0 V15.03.02.13 Cross Site Request Forgery (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.592199"
},
{
"tags": [
"related"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolReboot-20adf0aa1185806a9d20ee5c355c08a6?pvs=73"
},
{
"tags": [
"exploit"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolRestoreSet-20adf0aa11858094a25ae21f9b4203da"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-09T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-09T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-09T09:47:36.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9 cross-site request forgery"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5900",
"datePublished": "2025-06-09T22:00:19.518Z",
"dateReserved": "2025-06-09T07:42:33.564Z",
"dateUpdated": "2025-06-10T15:29:00.898Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5847 (GCVE-0-2025-5847)
Vulnerability from nvd – Published: 2025-06-08 13:31 – Updated: 2025-06-09 13:54| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5847",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-09T13:53:24.790033Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T13:54:42.018Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP POST Request Handler"
],
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.02.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ysnysnysn (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda AC9 15.03.02.13 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion formSetSafeWanWebMan der Datei /goform/SetRemoteWebCfg der Komponente HTTP POST Request Handler. Durch das Manipulieren des Arguments remoteIp mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-08T13:32:05.147Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311593 | Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311593"
},
{
"name": "VDB-311593 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311593"
},
{
"name": "Submit #591362 | Tenda AC9 V1.0 V15.03.02.13 stack overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.591362"
},
{
"tags": [
"exploit"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetSafeWanWebMan-20adf0aa118580a29e80cef9109c947a"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-08T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-08T11:27:37.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5847",
"datePublished": "2025-06-08T13:31:44.996Z",
"dateReserved": "2025-06-08T09:22:34.441Z",
"dateUpdated": "2025-06-09T13:54:42.018Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5839 (GCVE-0-2025-5839)
Vulnerability from nvd – Published: 2025-06-07 17:31 – Updated: 2025-06-09 03:34| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5839",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-09T03:34:33.186014Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T03:34:50.223Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"POST Request Handler"
],
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.02.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ysnysn0121 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC9 15.03.02.13 entdeckt. Dies betrifft die Funktion fromadvsetlanip der Datei /goform/AdvSetLanip der Komponente POST Request Handler. Durch das Manipulieren des Arguments lanMask mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-07T17:31:13.113Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311582 | Tenda AC9 POST Request AdvSetLanip fromadvsetlanip buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311582"
},
{
"name": "VDB-311582 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311582"
},
{
"name": "Submit #591369 | Tenda AC9 V1.0 V15.03.02.13 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.591369"
},
{
"tags": [
"exploit"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromadvsetlanip-20adf0aa11858027b7c3c2f4e44bb867"
},
{
"tags": [
"broken-link",
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-06T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-06T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-06T22:21:47.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9 POST Request AdvSetLanip fromadvsetlanip buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5839",
"datePublished": "2025-06-07T17:31:13.113Z",
"dateReserved": "2025-06-06T20:16:06.753Z",
"dateUpdated": "2025-06-09T03:34:50.223Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5836 (GCVE-0-2025-5836)
Vulnerability from nvd – Published: 2025-06-07 13:31 – Updated: 2025-06-09 15:06| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5836",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-09T15:06:27.930039Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T15:06:31.883Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetIptv-209df0aa11858061ae2bcbf83918d034"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"POST Request Handler"
],
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.02.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ysnysn (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC9 15.03.02.13 ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetIptv der Datei /goform/SetIPTVCfg der Komponente POST Request Handler. Durch Manipulation des Arguments list mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-07T13:31:06.620Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311579 | Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311579"
},
{
"name": "VDB-311579 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311579"
},
{
"name": "Submit #591363 | Tenda AC9 V1.0 V15.03.02.13 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.591363"
},
{
"tags": [
"exploit"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetIptv-209df0aa11858061ae2bcbf83918d034"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-06T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-06T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-06T22:17:03.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5836",
"datePublished": "2025-06-07T13:31:06.620Z",
"dateReserved": "2025-06-06T20:11:59.450Z",
"dateUpdated": "2025-06-09T15:06:31.883Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-10280 (GCVE-0-2024-10280)
Vulnerability from nvd – Published: 2024-10-23 13:31 – Updated: 2024-10-23 17:41- CWE-476 - NULL Pointer Dereference
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac6_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.23"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac8_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.34.06"
}
]
},
{
"cpes": [
"cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac8_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.34.09"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.48.23"
},
{
"status": "affected",
"version": "16.03.48.19"
},
{
"status": "affected",
"version": "16.03.48.20"
},
{
"status": "affected",
"version": "16.03.48.13"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac1206_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.23"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac9_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.42"
},
{
"status": "affected",
"version": "15.03.05.19\\(6318_\\)"
},
{
"status": "affected",
"version": "15.03.05.14"
},
{
"status": "affected",
"version": "15.03.2.13"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19\\(6318\\)"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9\\(1307\\)"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.16"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.14"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac7_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac15_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.18"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac15_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10280",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T17:28:19.760214Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T17:41:57.370Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC8",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC15",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC500",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC1206",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "minipython (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.8,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T13:31:07.315Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.281555"
},
{
"name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.281555"
},
{
"name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.426417"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-10-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-10-23T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-10-23T08:07:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-10280",
"datePublished": "2024-10-23T13:31:07.315Z",
"dateReserved": "2024-10-23T06:02:03.363Z",
"dateUpdated": "2024-10-23T17:41:57.370Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-14286 (GCVE-0-2025-14286)
Vulnerability from cvelistv5 – Published: 2025-12-09 01:32 – Updated: 2025-12-09 16:03| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-14286",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-09T14:35:32.257434Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T16:03:13.496Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN11.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Configuration File Handler"
],
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.14_multi"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jiahui2888 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda AC9 15.03.05.14_multi. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/DownloadCfg.jpg of the component Configuration File Handler. This manipulation causes information disclosure. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:W/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "Information Disclosure",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "Improper Access Controls",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T01:32:07.198Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-334874 | Tenda AC9 Configuration File DownloadCfg.jpg information disclosure",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.334874"
},
{
"name": "VDB-334874 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.334874"
},
{
"name": "Submit #702723 | Tenda AC9 V1.0 V15.03.05.14_multi Information Disclosure",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.702723"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN11.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-12-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-12-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-12-08T19:54:43.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9 Configuration File DownloadCfg.jpg information disclosure"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-14286",
"datePublished": "2025-12-09T01:32:07.198Z",
"dateReserved": "2025-12-08T18:49:39.958Z",
"dateUpdated": "2025-12-09T16:03:13.496Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-10443 (GCVE-0-2025-10443)
Vulnerability from cvelistv5 – Published: 2025-09-15 11:32 – Updated: 2025-09-15 11:40| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10443",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-15T11:40:27.372112Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T11:40:44.495Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.14"
},
{
"status": "affected",
"version": "15.03.05.18"
}
]
},
{
"product": "AC15",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.14"
},
{
"status": "affected",
"version": "15.03.05.18"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "shiny (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. This vulnerability affects the function formexeCommand of the file /goform/exeCommand. Such manipulation of the argument cmdinput leads to buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Tenda AC9 and AC15 15.03.05.14/15.03.05.18 entdeckt. Dabei betrifft es die Funktion formexeCommand der Datei /goform/exeCommand. Dank Manipulation des Arguments cmdinput mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Die Schwachstelle wurde \u00f6ffentlich offengelegt und k\u00f6nnte ausgenutzt werden."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T11:32:07.435Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-323877 | Tenda AC9/AC15 exeCommand formexeCommand buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.323877"
},
{
"name": "VDB-323877 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.323877"
},
{
"name": "Submit #647840 | Tenda Tenda AC15\u3001AC9 AC15 V1.0BR_V15.03.05.18 AC9 V1.0BR_V15.03.05.14 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.647840"
},
{
"tags": [
"related"
],
"url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC15_AC9_Bof.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC15_AC9_Bof.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-09-14T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-09-14T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-09-14T17:47:30.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9/AC15 exeCommand formexeCommand buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-10443",
"datePublished": "2025-09-15T11:32:07.435Z",
"dateReserved": "2025-09-14T15:42:18.331Z",
"dateUpdated": "2025-09-15T11:40:44.495Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-10442 (GCVE-0-2025-10442)
Vulnerability from cvelistv5 – Published: 2025-09-15 11:02 – Updated: 2025-09-15 11:59| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10442",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-15T11:58:44.891161Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T11:59:00.751Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.14"
}
]
},
{
"product": "AC15",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.14"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "shiny (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC9 and AC15 15.03.05.14 gefunden. Dies betrifft die Funktion formexeCommand der Datei /goform/exeCommand. Dank der Manipulation des Arguments cmdinput mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T11:02:06.735Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-323876 | Tenda AC9/AC15 exeCommand formexeCommand os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.323876"
},
{
"name": "VDB-323876 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.323876"
},
{
"name": "Submit #647838 | Tenda Tenda AC9 V1.0BR_V15.03.05.14 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.647838"
},
{
"name": "Submit #647839 | Tenda Tenda AC15 V1.0BR_V15.03.05.18 OS Command Injection (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.647839"
},
{
"tags": [
"related"
],
"url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC9_CJ.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC9_CJ.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-09-14T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-09-14T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-09-14T17:46:07.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9/AC15 exeCommand formexeCommand os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-10442",
"datePublished": "2025-09-15T11:02:06.735Z",
"dateReserved": "2025-09-14T15:40:13.804Z",
"dateUpdated": "2025-09-15T11:59:00.751Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-9731 (GCVE-0-2025-9731)
Vulnerability from cvelistv5 – Published: 2025-08-31 13:32 – Updated: 2025-09-02 15:14| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9731",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-02T14:40:47.599793Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-02T15:14:30.872Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/August829/Yu/blob/main/58ead8e7e08bfb0e4.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Administrative Interface"
],
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Yu_Bao (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda AC9 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation causes hard-coded credentials. It is possible to launch the attack on the local host. The attack\u0027s complexity is rated as high. The exploitability is regarded as difficult. The exploit has been publicly disclosed and may be utilized."
},
{
"lang": "de",
"value": "In Tenda AC9 15.03.05.19 wurde eine Schwachstelle gefunden. Dies betrifft einen unbekannten Teil der Datei /etc_ro/shadow der Komponente Administrative Interface. Durch Manipulieren mit unbekannten Daten kann eine hard-coded credentials-Schwachstelle ausgenutzt werden. Der Angriff ist nur lokal m\u00f6glich. Ein Angriff erfordert eine vergleichsweise hohe Komplexit\u00e4t. Die Ausnutzbarkeit gilt als schwierig. Die Schwachstelle wurde \u00f6ffentlich offengelegt und k\u00f6nnte ausgenutzt werden."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 2,
"baseSeverity": "LOW",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 1,
"vectorString": "AV:L/AC:H/Au:S/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-31T13:32:07.821Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-322022 | Tenda AC9 Administrative shadow hard-coded credentials",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.322022"
},
{
"name": "VDB-322022 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.322022"
},
{
"name": "Submit #639748 | Tenda AC9 V15.03.05.19 Hard-coded Credentials",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.639748"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/August829/Yu/blob/main/58ead8e7e08bfb0e4.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-08-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-08-30T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-08-30T16:03:04.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9 Administrative shadow hard-coded credentials"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-9731",
"datePublished": "2025-08-31T13:32:07.821Z",
"dateReserved": "2025-08-30T13:58:00.879Z",
"dateUpdated": "2025-09-02T15:14:30.872Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5900 (GCVE-0-2025-5900)
Vulnerability from cvelistv5 – Published: 2025-06-09 22:00 – Updated: 2025-06-10 15:29| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5900",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:21:05.917336Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T15:29:00.898Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolRestoreSet-20adf0aa11858094a25ae21f9b4203da"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.02.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ysnysn0121 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as problematic, was found in Tenda AC9 15.03.02.13. This affects an unknown part. The manipulation leads to cross-site request forgery. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine problematische Schwachstelle in Tenda AC9 15.03.02.13 gefunden. Dabei betrifft es einen unbekannter Codeteil. Durch Beeinflussen mit unbekannten Daten kann eine cross-site request forgery-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "Cross-Site Request Forgery",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T22:00:19.518Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311673 | Tenda AC9 cross-site request forgery",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.311673"
},
{
"name": "VDB-311673 | CTI Indicators (IOB, IOC)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311673"
},
{
"name": "Submit #592198 | Tenda AC9 V1.0 V15.03.02.13 Cross Site Request Forgery",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.592198"
},
{
"name": "Submit #592199 | Tenda AC9 V1.0 V15.03.02.13 Cross Site Request Forgery (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.592199"
},
{
"tags": [
"related"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolReboot-20adf0aa1185806a9d20ee5c355c08a6?pvs=73"
},
{
"tags": [
"exploit"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolRestoreSet-20adf0aa11858094a25ae21f9b4203da"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-09T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-09T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-09T09:47:36.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9 cross-site request forgery"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5900",
"datePublished": "2025-06-09T22:00:19.518Z",
"dateReserved": "2025-06-09T07:42:33.564Z",
"dateUpdated": "2025-06-10T15:29:00.898Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5847 (GCVE-0-2025-5847)
Vulnerability from cvelistv5 – Published: 2025-06-08 13:31 – Updated: 2025-06-09 13:54| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5847",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-09T13:53:24.790033Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T13:54:42.018Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP POST Request Handler"
],
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.02.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ysnysnysn (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda AC9 15.03.02.13 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion formSetSafeWanWebMan der Datei /goform/SetRemoteWebCfg der Komponente HTTP POST Request Handler. Durch das Manipulieren des Arguments remoteIp mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-08T13:32:05.147Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311593 | Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311593"
},
{
"name": "VDB-311593 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311593"
},
{
"name": "Submit #591362 | Tenda AC9 V1.0 V15.03.02.13 stack overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.591362"
},
{
"tags": [
"exploit"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetSafeWanWebMan-20adf0aa118580a29e80cef9109c947a"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-08T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-08T11:27:37.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5847",
"datePublished": "2025-06-08T13:31:44.996Z",
"dateReserved": "2025-06-08T09:22:34.441Z",
"dateUpdated": "2025-06-09T13:54:42.018Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5839 (GCVE-0-2025-5839)
Vulnerability from cvelistv5 – Published: 2025-06-07 17:31 – Updated: 2025-06-09 03:34| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5839",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-09T03:34:33.186014Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T03:34:50.223Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"POST Request Handler"
],
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.02.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ysnysn0121 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC9 15.03.02.13 entdeckt. Dies betrifft die Funktion fromadvsetlanip der Datei /goform/AdvSetLanip der Komponente POST Request Handler. Durch das Manipulieren des Arguments lanMask mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-07T17:31:13.113Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311582 | Tenda AC9 POST Request AdvSetLanip fromadvsetlanip buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311582"
},
{
"name": "VDB-311582 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311582"
},
{
"name": "Submit #591369 | Tenda AC9 V1.0 V15.03.02.13 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.591369"
},
{
"tags": [
"exploit"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromadvsetlanip-20adf0aa11858027b7c3c2f4e44bb867"
},
{
"tags": [
"broken-link",
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-06T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-06T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-06T22:21:47.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9 POST Request AdvSetLanip fromadvsetlanip buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5839",
"datePublished": "2025-06-07T17:31:13.113Z",
"dateReserved": "2025-06-06T20:16:06.753Z",
"dateUpdated": "2025-06-09T03:34:50.223Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5836 (GCVE-0-2025-5836)
Vulnerability from cvelistv5 – Published: 2025-06-07 13:31 – Updated: 2025-06-09 15:06| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5836",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-09T15:06:27.930039Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T15:06:31.883Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetIptv-209df0aa11858061ae2bcbf83918d034"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"POST Request Handler"
],
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.02.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ysnysn (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC9 15.03.02.13 ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetIptv der Datei /goform/SetIPTVCfg der Komponente POST Request Handler. Durch Manipulation des Arguments list mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-07T13:31:06.620Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311579 | Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311579"
},
{
"name": "VDB-311579 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311579"
},
{
"name": "Submit #591363 | Tenda AC9 V1.0 V15.03.02.13 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.591363"
},
{
"tags": [
"exploit"
],
"url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetIptv-209df0aa11858061ae2bcbf83918d034"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-06T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-06T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-06T22:17:03.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5836",
"datePublished": "2025-06-07T13:31:06.620Z",
"dateReserved": "2025-06-06T20:11:59.450Z",
"dateUpdated": "2025-06-09T15:06:31.883Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-10280 (GCVE-0-2024-10280)
Vulnerability from cvelistv5 – Published: 2024-10-23 13:31 – Updated: 2024-10-23 17:41- CWE-476 - NULL Pointer Dereference
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac6_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.23"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac8_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.34.06"
}
]
},
{
"cpes": [
"cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac8_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.34.09"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.48.23"
},
{
"status": "affected",
"version": "16.03.48.19"
},
{
"status": "affected",
"version": "16.03.48.20"
},
{
"status": "affected",
"version": "16.03.48.13"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac1206_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.23"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac9_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.42"
},
{
"status": "affected",
"version": "15.03.05.19\\(6318_\\)"
},
{
"status": "affected",
"version": "15.03.05.14"
},
{
"status": "affected",
"version": "15.03.2.13"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19\\(6318\\)"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9\\(1307\\)"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.16"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.14"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac7_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac15_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.18"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac15_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10280",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T17:28:19.760214Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T17:41:57.370Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC8",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC15",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC500",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC1206",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "minipython (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.8,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T13:31:07.315Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.281555"
},
{
"name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.281555"
},
{
"name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.426417"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-10-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-10-23T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-10-23T08:07:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-10280",
"datePublished": "2024-10-23T13:31:07.315Z",
"dateReserved": "2024-10-23T06:02:03.363Z",
"dateUpdated": "2024-10-23T17:41:57.370Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
VAR-202402-0826
Vulnerability from variot - Updated: 2024-03-22 23:05Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.
Tenda AC9 has a buffer overflow vulnerability. The vulnerability stems from the failure of the setSchedWifi function to correctly verify the length of input data
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202402-0826",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42_multi"
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac9 firmware 15.03.06.42 multi"
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "3.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-14374"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-002610"
},
{
"db": "NVD",
"id": "CVE-2024-24543"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2024-24543"
}
]
},
"cve": "CVE-2024-24543",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-14374",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2024-24543",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2024-24543",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-14374",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-14374"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-002610"
},
{
"db": "NVD",
"id": "CVE-2024-24543"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\r\n\r\nTenda AC9 has a buffer overflow vulnerability. The vulnerability stems from the failure of the setSchedWifi function to correctly verify the length of input data",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-24543"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-002610"
},
{
"db": "CNVD",
"id": "CNVD-2024-14374"
},
{
"db": "VULMON",
"id": "CVE-2024-24543"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-24543",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2024-002610",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-14374",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2024-24543",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-14374"
},
{
"db": "VULMON",
"id": "CVE-2024-24543"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-002610"
},
{
"db": "NVD",
"id": "CVE-2024-24543"
}
]
},
"id": "VAR-202402-0826",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-14374"
}
],
"trust": 1.04830826
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-14374"
}
]
},
"last_update_date": "2024-03-22T23:05:07.358000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC9 buffer overflow vulnerability (CNVD-2024-14374)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/534936"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-14374"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-002610"
},
{
"db": "NVD",
"id": "CVE-2024-24543"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/timeseg/iot_cve/blob/main/tenda/ac9v3/0130/setschedwifi.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-24543"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-14374"
},
{
"db": "VULMON",
"id": "CVE-2024-24543"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-002610"
},
{
"db": "NVD",
"id": "CVE-2024-24543"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-14374"
},
{
"db": "VULMON",
"id": "CVE-2024-24543"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-002610"
},
{
"db": "NVD",
"id": "CVE-2024-24543"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-03-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-14374"
},
{
"date": "2024-02-05T00:00:00",
"db": "VULMON",
"id": "CVE-2024-24543"
},
{
"date": "2024-02-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-002610"
},
{
"date": "2024-02-05T21:15:12.073000",
"db": "NVD",
"id": "CVE-2024-24543"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-03-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-14374"
},
{
"date": "2024-02-06T00:00:00",
"db": "VULMON",
"id": "CVE-2024-24543"
},
{
"date": "2024-02-16T01:03:00",
"db": "JVNDB",
"id": "JVNDB-2024-002610"
},
{
"date": "2024-02-14T17:13:32.827000",
"db": "NVD",
"id": "CVE-2024-24543"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-002610"
}
],
"trust": 0.8
}
}
VAR-202308-3781
Vulnerability from variot - Updated: 2024-01-20 23:21Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3781",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "fh1205",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.0.7\\(775\\)"
},
{
"model": "fh1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42_multi"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.44"
},
{
"model": "f1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1205",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "f1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"cve": "CVE-2023-38933",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38933",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38933",
"trust": 1.8,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38933"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38933",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021661",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"id": "VAR-202308-3781",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.66374115
},
"last_update_date": "2024-01-20T23:21:05.858000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetclientstate/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38933"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"date": "2023-08-07T19:15:11.133000",
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T07:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"date": "2023-08-10T17:17:41.653000",
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
}
],
"trust": 0.8
}
}
VAR-202308-3714
Vulnerability from variot - Updated: 2024-01-20 23:18Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3714",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "fh1205",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.0.7\\(775\\)"
},
{
"model": "fh1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42_multi"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.44"
},
{
"model": "f1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1205",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "f1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"cve": "CVE-2023-38936",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38936",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38936",
"trust": 1.8,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38936"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38936",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021659",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"id": "VAR-202308-3714",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.66374115
},
"last_update_date": "2024-01-20T23:18:08.206000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetspeedwan/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38936"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"date": "2023-08-07T19:15:11.343000",
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T07:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"date": "2023-08-10T18:20:51.897000",
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
}
],
"trust": 0.8
}
}
VAR-202308-4027
Vulnerability from variot - Updated: 2024-01-20 23:18Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. ac1206 firmware, AC5 firmware, AC9 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-4027",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.10.13"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42_multi"
},
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"cve": "CVE-2023-38935",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38935",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38935",
"trust": 1.8,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. ac1206 firmware, AC5 firmware, AC9 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38935"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38935",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021660",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"id": "VAR-202308-4027",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5516548666666666
},
"last_update_date": "2024-01-20T23:18:08.182000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetqosband/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38935"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"date": "2023-08-07T19:15:11.277000",
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T07:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"date": "2023-08-10T17:18:24.527000",
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
}
],
"trust": 0.8
}
}
VAR-202308-4213
Vulnerability from variot - Updated: 2024-01-20 23:04Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-4213",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.10.13"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42_multi"
},
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.44"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"cve": "CVE-2023-38937",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38937",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38937",
"trust": 1.8,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38937"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38937",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021658",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"id": "VAR-202308-4213",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5516548666666666
},
"last_update_date": "2024-01-20T23:04:04.486000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetvirtualser/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38937"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"date": "2023-08-07T19:15:11.413000",
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T07:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"date": "2023-08-10T18:22:01.703000",
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
}
],
"trust": 0.8
}
}
VAR-202308-3852
Vulnerability from variot - Updated: 2024-01-19 23:21Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. AC7 firmware, f1203 firmware, fh1205 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3852",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "fh1205",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.0.7\\(775\\)"
},
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42_multi"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.44"
},
{
"model": "f1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "f1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1205",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"cve": "CVE-2023-38930",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38930",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38930",
"trust": 1.8,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. AC7 firmware, f1203 firmware, fh1205 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38930"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38930",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021095",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"id": "VAR-202308-3852",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.73276942
},
"last_update_date": "2024-01-19T23:21:34.368000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/addwifimacfilter/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38930"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"date": "2023-08-07T19:15:10.907000",
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-18T06:42:00",
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"date": "2023-08-09T18:05:36.363000",
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
}
],
"trust": 0.8
}
}
VAR-201810-0276
Vulnerability from variot - Updated: 2023-12-18 14:05An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'startIp' and 'endIp' parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201810-0276",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac10",
"scope": "eq",
"trust": 2.4,
"vendor": "tenda",
"version": "15.03.06.23_cn"
},
{
"model": "ac15",
"scope": "eq",
"trust": 2.4,
"vendor": "tenda",
"version": "15.03.05.19_cn"
},
{
"model": "ac7",
"scope": "eq",
"trust": 2.4,
"vendor": "tenda",
"version": "15.03.06.44_cn"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "15.03.05.19\\(6318\\)_cn"
},
{
"model": "ac18",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "15.03.05.19\\(6318\\)_cn"
},
{
"model": "ac18",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "15.03.05.19(6318)_cn"
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "15.03.05.19(6318)_cn"
},
{
"model": "ac7 v15.03.06.44 cn",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
},
{
"model": "ac9 v15.03.05.19 cn",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
},
{
"model": "ac10 v15.03.06.23 cn",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
},
{
"model": "ac15 v15.03.05.19 cn",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
},
{
"model": "ac18 v15.03.05.19 cn",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-01885"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011970"
},
{
"db": "NVD",
"id": "CVE-2018-18730"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1357"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-18730"
}
]
},
"cve": "CVE-2018-18730",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 7.8,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2018-18730",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-01885",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "VHN-129319",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2018-18730",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-18730",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2019-01885",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201810-1357",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-129319",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-01885"
},
{
"db": "VULHUB",
"id": "VHN-129319"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011970"
},
{
"db": "NVD",
"id": "CVE-2018-18730"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1357"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-18730"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011970"
},
{
"db": "CNVD",
"id": "CNVD-2019-01885"
},
{
"db": "VULHUB",
"id": "VHN-129319"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-18730",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011970",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1357",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2019-01885",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-129319",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-01885"
},
{
"db": "VULHUB",
"id": "VHN-129319"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011970"
},
{
"db": "NVD",
"id": "CVE-2018-18730"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1357"
}
]
},
"id": "VAR-201810-0276",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-01885"
},
{
"db": "VULHUB",
"id": "VHN-129319"
}
],
"trust": 1.4927520825
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-01885"
}
]
},
"last_update_date": "2023-12-18T14:05:18.908000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.tenda.com.cn/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-011970"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-129319"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011970"
},
{
"db": "NVD",
"id": "CVE-2018-18730"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/zillr0/routers/blob/master/tenda/stack3.md"
},
{
"trust": 1.4,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18730"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-18730"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-01885"
},
{
"db": "VULHUB",
"id": "VHN-129319"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011970"
},
{
"db": "NVD",
"id": "CVE-2018-18730"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1357"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-01885"
},
{
"db": "VULHUB",
"id": "VHN-129319"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011970"
},
{
"db": "NVD",
"id": "CVE-2018-18730"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1357"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-01-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-01885"
},
{
"date": "2018-10-29T00:00:00",
"db": "VULHUB",
"id": "VHN-129319"
},
{
"date": "2019-01-28T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-011970"
},
{
"date": "2018-10-29T12:29:07.727000",
"db": "NVD",
"id": "CVE-2018-18730"
},
{
"date": "2018-10-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201810-1357"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-01-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-01885"
},
{
"date": "2018-12-14T00:00:00",
"db": "VULHUB",
"id": "VHN-129319"
},
{
"date": "2019-01-28T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-011970"
},
{
"date": "2018-12-14T15:37:52.763000",
"db": "NVD",
"id": "CVE-2018-18730"
},
{
"date": "2018-10-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201810-1357"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201810-1357"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Tenda Product buffer error vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-011970"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer overflow",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201810-1357"
}
],
"trust": 0.6
}
}
VAR-202203-1209
Vulnerability from variot - Updated: 2023-12-18 14:04Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function. The Tenda AC9 is a wireless router from the Chinese company Tenda
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202203-1209",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.2.21"
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v15.03.2.21"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-24427"
},
{
"db": "NVD",
"id": "CVE-2022-25427"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-25427"
}
]
},
"cve": "CVE-2022-25427",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-24427",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-25427",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2022-24427",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202203-1861",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-24427"
},
{
"db": "NVD",
"id": "CVE-2022-25427"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1861"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function. The Tenda AC9 is a wireless router from the Chinese company Tenda",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-25427"
},
{
"db": "CNVD",
"id": "CNVD-2022-24427"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-25427",
"trust": 2.2
},
{
"db": "CNVD",
"id": "CNVD-2022-24427",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1861",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-24427"
},
{
"db": "NVD",
"id": "CVE-2022-25427"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1861"
}
]
},
"id": "VAR-202203-1209",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-24427"
}
],
"trust": 1.04830826
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-24427"
}
]
},
"last_update_date": "2023-12-18T14:04:01.807000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC9 openSchedWifi function stack overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/328496"
},
{
"title": "Tenda AC9 Fixes for command injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=186939"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-24427"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1861"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-25427"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/2"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-25427"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-25427/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-24427"
},
{
"db": "NVD",
"id": "CVE-2022-25427"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1861"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-24427"
},
{
"db": "NVD",
"id": "CVE-2022-25427"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1861"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-02T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-24427"
},
{
"date": "2022-03-18T21:15:07.907000",
"db": "NVD",
"id": "CVE-2022-25427"
},
{
"date": "2022-03-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202203-1861"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-03-31T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-24427"
},
{
"date": "2023-08-08T14:21:49.707000",
"db": "NVD",
"id": "CVE-2022-25427"
},
{
"date": "2022-03-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202203-1861"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202203-1861"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC9 openSchedWifi function stack overflow vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-24427"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "command injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202203-1861"
}
],
"trust": 0.6
}
}
VAR-201807-1285
Vulnerability from variot - Updated: 2023-12-18 14:01Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI. Tenda AC7 , AC9 ,and AC10 Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7, AC9 and AC10 are all wireless router products from Tenda. A buffer overflow vulnerability exists in TendaAC715.03.06.44_CN and previous versions, AC915.03.05.19 (6318)_CN and previous versions, and AC1015.03.06.23_CN and earlier. An attacker could exploit the vulnerability with a longer \342\200\230limitSpeed\342\200\231 or \342\200\230limitSpeedup\342\200\231 parameter to cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201807-1285",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac10",
"scope": "lte",
"trust": 1.0,
"vendor": "tendacn",
"version": "15.03.06.23_cn"
},
{
"model": "ac15",
"scope": "lte",
"trust": 1.0,
"vendor": "tendacn",
"version": "15.03.05.19_cn"
},
{
"model": "ac18",
"scope": "lte",
"trust": 1.0,
"vendor": "tendacn",
"version": "15.03.05.19\\(6318\\)_cn"
},
{
"model": "ac9",
"scope": "lte",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)_cn"
},
{
"model": "ac7",
"scope": "lte",
"trust": 1.0,
"vendor": "tendacn",
"version": "15.03.06.44_cn"
},
{
"model": "ac10",
"scope": "lte",
"trust": 0.8,
"vendor": "tenda",
"version": "15.03.06.23_cn"
},
{
"model": "ac15",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac18",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": "lte",
"trust": 0.8,
"vendor": "tenda",
"version": "15.03.06.44_cn"
},
{
"model": "ac9",
"scope": "lte",
"trust": 0.8,
"vendor": "tenda",
"version": "15.03.05.19(6318)_cn"
},
{
"model": "ac7 \u003c=15.03.06.44 cn",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
},
{
"model": "ac10 \u003c=15.03.06.23 cn",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
},
{
"model": "ac9 \u003c=15.03.05.19 cn",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": "eq",
"trust": 0.6,
"vendor": "tendacn",
"version": "15.03.06.44_cn"
},
{
"model": "ac10",
"scope": "eq",
"trust": 0.6,
"vendor": "tendacn",
"version": "15.03.06.23_cn"
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.6,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)_cn"
},
{
"model": "ac18",
"scope": "eq",
"trust": 0.6,
"vendor": "tendacn",
"version": "15.03.05.19\\(6318\\)_cn"
},
{
"model": "ac15",
"scope": "eq",
"trust": 0.6,
"vendor": "tendacn",
"version": "15.03.05.19_cn"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-14983"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-008461"
},
{
"db": "NVD",
"id": "CVE-2018-14492"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-1668"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tendacn:ac7_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.03.06.44_cn",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tendacn:ac7:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tendacn:ac9_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "v15.03.05.19\\(6318\\)_cn",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tendacn:ac9:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tendacn:ac10_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.03.06.23_cn",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tendacn:ac10:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tendacn:ac15_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.03.05.19_cn",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tendacn:ac15:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tendacn:ac18_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.03.05.19\\(6318\\)_cn",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tendacn:ac18:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14492"
}
]
},
"cve": "CVE-2018-14492",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 5.0,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2018-14492",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2018-14983",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "VHN-124657",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2018-14492",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-14492",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2018-14983",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201807-1668",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-124657",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-14983"
},
{
"db": "VULHUB",
"id": "VHN-124657"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-008461"
},
{
"db": "NVD",
"id": "CVE-2018-14492"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-1668"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI. Tenda AC7 , AC9 ,and AC10 Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7, AC9 and AC10 are all wireless router products from Tenda. A buffer overflow vulnerability exists in TendaAC715.03.06.44_CN and previous versions, AC915.03.05.19 (6318)_CN and previous versions, and AC1015.03.06.23_CN and earlier. An attacker could exploit the vulnerability with a longer \\342\\200\\230limitSpeed\\342\\200\\231 or \\342\\200\\230limitSpeedup\\342\\200\\231 parameter to cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14492"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-008461"
},
{
"db": "CNVD",
"id": "CNVD-2018-14983"
},
{
"db": "VULHUB",
"id": "VHN-124657"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-14492",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2018-008461",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201807-1668",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2018-14983",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-124657",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-14983"
},
{
"db": "VULHUB",
"id": "VHN-124657"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-008461"
},
{
"db": "NVD",
"id": "CVE-2018-14492"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-1668"
}
]
},
"id": "VAR-201807-1285",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-14983"
},
{
"db": "VULHUB",
"id": "VHN-124657"
}
],
"trust": 1.4236694433333335
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-14983"
}
]
},
"last_update_date": "2023-12-18T14:01:10.713000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.tenda.com.cn/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-008461"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.1
},
{
"problemtype": "CWE-119",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-124657"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-008461"
},
{
"db": "NVD",
"id": "CVE-2018-14492"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "https://github.com/zillr0/routers/blob/master/tendaoob1.md"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14492"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-14492"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-14983"
},
{
"db": "VULHUB",
"id": "VHN-124657"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-008461"
},
{
"db": "NVD",
"id": "CVE-2018-14492"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-1668"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2018-14983"
},
{
"db": "VULHUB",
"id": "VHN-124657"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-008461"
},
{
"db": "NVD",
"id": "CVE-2018-14492"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-1668"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-08-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-14983"
},
{
"date": "2018-07-21T00:00:00",
"db": "VULHUB",
"id": "VHN-124657"
},
{
"date": "2018-10-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-008461"
},
{
"date": "2018-07-21T12:29:00.333000",
"db": "NVD",
"id": "CVE-2018-14492"
},
{
"date": "2018-07-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201807-1668"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-08-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-14983"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULHUB",
"id": "VHN-124657"
},
{
"date": "2018-10-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-008461"
},
{
"date": "2020-08-24T17:37:01.140000",
"db": "NVD",
"id": "CVE-2018-14492"
},
{
"date": "2020-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201807-1668"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201807-1668"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Tenda Product buffer error vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-008461"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201807-1668"
}
],
"trust": 0.6
}
}
VAR-202203-0586
Vulnerability from variot - Updated: 2023-12-18 13:59Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function. The Tenda AC9 is a wireless router from the Chinese company Tenda
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202203-0586",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.2.21"
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v15.03.2.21"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-25785"
},
{
"db": "NVD",
"id": "CVE-2022-25433"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-25433"
}
]
},
"cve": "CVE-2022-25433",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-25785",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-25433",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2022-25785",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202203-1854",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-25785"
},
{
"db": "NVD",
"id": "CVE-2022-25433"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1854"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function. The Tenda AC9 is a wireless router from the Chinese company Tenda",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-25433"
},
{
"db": "CNVD",
"id": "CNVD-2022-25785"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-25433",
"trust": 2.2
},
{
"db": "CNVD",
"id": "CNVD-2022-25785",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1854",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-25785"
},
{
"db": "NVD",
"id": "CVE-2022-25433"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1854"
}
]
},
"id": "VAR-202203-0586",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-25785"
}
],
"trust": 1.04830826
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-25785"
}
]
},
"last_update_date": "2023-12-18T13:59:50.333000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC9 saveparentcontrolinfo function stack overflow vulnerability (CNVD-2022-25785)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/328511"
},
{
"title": "Tenda AC9 Fixes for command injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=186935"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-25785"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1854"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-25433"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/5"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-25433"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-25433/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-25785"
},
{
"db": "NVD",
"id": "CVE-2022-25433"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1854"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-25785"
},
{
"db": "NVD",
"id": "CVE-2022-25433"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1854"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-02T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-25785"
},
{
"date": "2022-03-18T21:15:08.057000",
"db": "NVD",
"id": "CVE-2022-25433"
},
{
"date": "2022-03-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202203-1854"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-02T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-25785"
},
{
"date": "2023-08-08T14:21:49.707000",
"db": "NVD",
"id": "CVE-2022-25433"
},
{
"date": "2022-03-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202203-1854"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202203-1854"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC9 saveparentcontrolinfo function stack overflow vulnerability (CNVD-2022-25785)",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-25785"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "command injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202203-1854"
}
],
"trust": 0.6
}
}
VAR-202202-1589
Vulnerability from variot - Updated: 2023-12-18 13:59Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo. Tenda AC9 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202202-1589",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "v15.03.2.21_cn"
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac9 firmware 15.03.2.21_cn"
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-006051"
},
{
"db": "NVD",
"id": "CVE-2022-25417"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:v15.03.2.21_cn:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-25417"
}
]
},
"cve": "CVE-2022-25417",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2022-25417",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-25417",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-25417",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202202-1828",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-006051"
},
{
"db": "NVD",
"id": "CVE-2022-25417"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1828"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo. Tenda AC9 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-25417"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-006051"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-25417",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-006051",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1828",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-006051"
},
{
"db": "NVD",
"id": "CVE-2022-25417"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1828"
}
]
},
"id": "VAR-202202-1589",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.44830826
},
"last_update_date": "2023-12-18T13:59:50.840000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.tendacn.com/default.html"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-006051"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-006051"
},
{
"db": "NVD",
"id": "CVE-2022-25417"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/3"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-25417"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-25417/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-006051"
},
{
"db": "NVD",
"id": "CVE-2022-25417"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1828"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-006051"
},
{
"db": "NVD",
"id": "CVE-2022-25417"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1828"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-06-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-006051"
},
{
"date": "2022-02-24T15:15:31.900000",
"db": "NVD",
"id": "CVE-2022-25417"
},
{
"date": "2022-02-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202202-1828"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-06-26T08:44:00",
"db": "JVNDB",
"id": "JVNDB-2022-006051"
},
{
"date": "2022-03-03T21:05:18.513000",
"db": "NVD",
"id": "CVE-2022-25417"
},
{
"date": "2022-03-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202202-1828"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202202-1828"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda\u00a0AC9\u00a0 Out-of-bounds write vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-006051"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202202-1828"
}
],
"trust": 0.6
}
}
VAR-202307-1306
Vulnerability from variot - Updated: 2023-12-18 13:59Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-1306",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "3.0"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
},
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0br"
},
{
"model": "fh1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.19_en"
},
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.20\\(408\\)"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37716"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\\(408\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.19_en:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:f1202_firmware:1.0br:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac1206_firmware:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37716"
}
]
},
"cve": "CVE-2023-37716",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-37716",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-1255",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"db": "VULMON",
"id": "CVE-2023-37716"
}
],
"trust": 0.99
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-37716",
"trust": 1.7
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1255",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-37716",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37716"
},
{
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
]
},
"id": "VAR-202307-1306",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5516548666666666
},
"last_update_date": "2023-12-18T13:59:00.602000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37716"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromnatstaticsetting/report.md"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-37716/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-37716"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37716"
},
{
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-37716"
},
{
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37716"
},
{
"date": "2023-07-14T00:15:09.430000",
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"date": "2023-07-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37716"
},
{
"date": "2023-07-21T14:33:30.690000",
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"date": "2023-07-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 Buffer error vulnerability",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
],
"trust": 0.6
}
}