3 vulnerabilities found for Automation FV Designer by Fatek

VAR-201702-0419

Vulnerability from variot - Updated: 2023-12-18 13:14

An issue was discovered in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0. By sending additional valid packets, an attacker could trigger a stack-based buffer overflow and cause a crash. Also, a malicious attacker can trigger a remote buffer overflow on the Fatek Communication Server. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Fatek Automation PM Designer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within parsing of a pm3 file. A malformed file can lead to heap memory corruption. A remote attacker can leverage this vulnerability to cause arbitrary code execution in the context of the user. Multiple Fatek Automation Products are prone to multiple remote code-execution vulnerabilities because it fails to perform adequate boundary checks on user-supplied input. Failed exploit attempts will likely result in denial-of-service conditions

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201702-0419",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "automation pm designer",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "fatek",
        "version": "2.1.2.2"
      },
      {
        "model": "automation fv designer",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "fatek",
        "version": "1.2.8.0"
      },
      {
        "model": "fv designer",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "fatek automation",
        "version": "1.2.8.0"
      },
      {
        "model": "pm designer",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "fatek automation",
        "version": "v3 2.1.2.2"
      },
      {
        "model": "pm designer",
        "scope": null,
        "trust": 0.7,
        "vendor": "fatek automation",
        "version": null
      },
      {
        "model": "fvdesigner",
        "scope": null,
        "trust": 0.7,
        "vendor": "fatek automation",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-16-525"
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-634"
      },
      {
        "db": "BID",
        "id": "93105"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007657"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-5798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-436"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:fatek:automation_fv_designer:1.2.8.0:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:fatek:automation_pm_designer:2.1.2.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2016-5798"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Ariele Caltabiano (kimiya)",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-16-525"
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-634"
      }
    ],
    "trust": 1.4
  },
  "cve": "CVE-2016-5798",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 5.0,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2016-5798",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "ZDI",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "ZDI-16-525",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "MEDIUM",
            "trust": 0.7,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "ZDI",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2016-5798",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "HIGH",
            "trust": 0.7,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2016-5798",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2016-5798",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "ZDI",
            "id": "ZDI-16-525",
            "trust": 0.7,
            "value": "MEDIUM"
          },
          {
            "author": "ZDI",
            "id": "CVE-2016-5798",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201610-436",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-16-525"
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-634"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007657"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-5798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-436"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0. By sending additional valid packets, an attacker could trigger a stack-based buffer overflow and cause a crash. Also, a malicious attacker can trigger a remote buffer overflow on the Fatek Communication Server. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Fatek Automation PM Designer.  User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within parsing of a pm3 file.  A malformed file can lead to heap memory corruption.  A remote attacker can leverage this vulnerability to cause arbitrary code execution in the context of the user. Multiple Fatek Automation Products are prone to multiple remote code-execution vulnerabilities because it fails to perform adequate boundary checks on user-supplied input. Failed exploit attempts will likely result in denial-of-service conditions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2016-5798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007657"
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-525"
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-634"
      },
      {
        "db": "BID",
        "id": "93105"
      }
    ],
    "trust": 3.15
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2016-5798",
        "trust": 3.4
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-16-287-06",
        "trust": 2.7
      },
      {
        "db": "BID",
        "id": "93105",
        "trust": 1.9
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-525",
        "trust": 1.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007657",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-3586",
        "trust": 0.7
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-3676",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-634",
        "trust": 0.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-436",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-16-525"
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-634"
      },
      {
        "db": "BID",
        "id": "93105"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007657"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-5798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-436"
      }
    ]
  },
  "id": "VAR-201702-0419",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.5535714
  },
  "last_update_date": "2023-12-18T13:14:25.792000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.fatek.com/en/"
      },
      {
        "title": "Fatek Automation has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-16-287-06"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-16-634"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007657"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007657"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-5798"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.4,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-16-287-06"
      },
      {
        "trust": 1.6,
        "url": "http://www.securityfocus.com/bid/93105"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-5798"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-5798"
      },
      {
        "trust": 0.3,
        "url": "http://www.fatek.com/en/"
      },
      {
        "trust": 0.3,
        "url": "http://www.zerodayinitiative.com/advisories/zdi-16-525/"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-16-634"
      },
      {
        "db": "BID",
        "id": "93105"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007657"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-5798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-436"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-16-525"
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-634"
      },
      {
        "db": "BID",
        "id": "93105"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007657"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-5798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-436"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-09-21T00:00:00",
        "db": "ZDI",
        "id": "ZDI-16-525"
      },
      {
        "date": "2016-12-14T00:00:00",
        "db": "ZDI",
        "id": "ZDI-16-634"
      },
      {
        "date": "2016-09-21T00:00:00",
        "db": "BID",
        "id": "93105"
      },
      {
        "date": "2017-03-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2016-007657"
      },
      {
        "date": "2017-02-13T21:59:00.267000",
        "db": "NVD",
        "id": "CVE-2016-5798"
      },
      {
        "date": "2016-09-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201610-436"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-09-21T00:00:00",
        "db": "ZDI",
        "id": "ZDI-16-525"
      },
      {
        "date": "2016-12-14T00:00:00",
        "db": "ZDI",
        "id": "ZDI-16-634"
      },
      {
        "date": "2016-10-26T09:08:00",
        "db": "BID",
        "id": "93105"
      },
      {
        "date": "2017-03-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2016-007657"
      },
      {
        "date": "2017-02-17T15:07:08.957000",
        "db": "NVD",
        "id": "CVE-2016-5798"
      },
      {
        "date": "2016-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201610-436"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-436"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fatek Automation PM Designer V3 and  FV Designer Vulnerable to stack-based buffer overflow",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007657"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-436"
      }
    ],
    "trust": 0.6
  }
}

CVE-2016-5800 (GCVE-0-2016-5800)

Vulnerability from cvelistv5 – Published: 2019-03-21 13:56 – Updated: 2024-08-06 01:15
VLAI?
Summary
A malicious attacker can trigger a remote buffer overflow in the Communication Server in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0.
Severity ?
No CVSS data available.
CWE
  • CWE-121 - Buffer overflow CWE-121
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T01:15:10.834Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-06"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Automation PM Designer V3",
          "vendor": "Fatek",
          "versions": [
            {
              "status": "affected",
              "version": "2.1.2.2"
            }
          ]
        },
        {
          "product": "Automation FV Designer",
          "vendor": "Fatek",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.8.0"
            }
          ]
        }
      ],
      "datePublic": "2016-10-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A malicious attacker can trigger a remote buffer overflow in the Communication Server in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Buffer overflow CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-21T13:56:42",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-06"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2016-5800",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Automation PM Designer V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2.1.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fatek"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Automation FV Designer",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.2.8.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fatek"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A malicious attacker can trigger a remote buffer overflow in the Communication Server in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Buffer overflow CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-06",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-06"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2016-5800",
    "datePublished": "2019-03-21T13:56:42",
    "dateReserved": "2016-06-23T00:00:00",
    "dateUpdated": "2024-08-06T01:15:10.834Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2016-5800 (GCVE-0-2016-5800)

Vulnerability from nvd – Published: 2019-03-21 13:56 – Updated: 2024-08-06 01:15
VLAI?
Summary
A malicious attacker can trigger a remote buffer overflow in the Communication Server in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0.
Severity ?
No CVSS data available.
CWE
  • CWE-121 - Buffer overflow CWE-121
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T01:15:10.834Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-06"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Automation PM Designer V3",
          "vendor": "Fatek",
          "versions": [
            {
              "status": "affected",
              "version": "2.1.2.2"
            }
          ]
        },
        {
          "product": "Automation FV Designer",
          "vendor": "Fatek",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.8.0"
            }
          ]
        }
      ],
      "datePublic": "2016-10-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A malicious attacker can trigger a remote buffer overflow in the Communication Server in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Buffer overflow CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-21T13:56:42",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-06"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2016-5800",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Automation PM Designer V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2.1.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fatek"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Automation FV Designer",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.2.8.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fatek"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A malicious attacker can trigger a remote buffer overflow in the Communication Server in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Buffer overflow CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-06",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-06"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2016-5800",
    "datePublished": "2019-03-21T13:56:42",
    "dateReserved": "2016-06-23T00:00:00",
    "dateUpdated": "2024-08-06T01:15:10.834Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}