Search criteria

4 vulnerabilities found for BIG-IP (Advanced WAF, APM, ASM) by F5

CVE-2022-27806 (GCVE-0-2022-27806)

Vulnerability from cvelistv5 – Published: 2022-05-05 16:29 – Updated: 2024-09-17 01:36
VLAI?
Summary
On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker assigned the Administrator role may be able to bypass Appliance mode restrictions, utilizing command injection vulnerabilities in undisclosed URIs in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
f5
References
Impacted products
Vendor Product Version
F5 BIG-IP (Advanced WAF, APM, ASM) Affected: 16.1.x
Affected: 15.1.x
Affected: 14.1.x
Affected: 13.1.x
Affected: 12.1.x
Affected: 11.6.x
Unaffected: 17.0.0 , < 17.0.x* (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:32:59.981Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.f5.com/csp/article/K68647001"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BIG-IP (Advanced WAF, APM, ASM)",
          "vendor": "F5",
          "versions": [
            {
              "status": "affected",
              "version": "16.1.x"
            },
            {
              "status": "affected",
              "version": "15.1.x"
            },
            {
              "status": "affected",
              "version": "14.1.x"
            },
            {
              "status": "affected",
              "version": "13.1.x"
            },
            {
              "status": "affected",
              "version": "12.1.x"
            },
            {
              "status": "affected",
              "version": "11.6.x"
            },
            {
              "lessThan": "17.0.x*",
              "status": "unaffected",
              "version": "17.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "BIG-IP Guided Configuration (GC)",
          "vendor": "F5",
          "versions": [
            {
              "lessThan": "9.0",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-05-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker assigned the Administrator role may be able to bypass Appliance mode restrictions, utilizing command injection vulnerabilities in undisclosed URIs in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-05T16:29:58",
        "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "shortName": "f5"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.f5.com/csp/article/K68647001"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "f5sirt@f5.com",
          "DATE_PUBLIC": "2022-05-04T14:00:00.000Z",
          "ID": "CVE-2022-27806",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BIG-IP (Advanced WAF, APM, ASM)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "!\u003e=",
                            "version_name": "17.0.x",
                            "version_value": "17.0.0"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "16.1.x",
                            "version_value": "16.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "15.1.x",
                            "version_value": "15.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "14.1.x",
                            "version_value": "14.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "13.1.x",
                            "version_value": "13.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "12.1.x",
                            "version_value": "12.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "11.6.x",
                            "version_value": "11.6.x"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "BIG-IP Guided Configuration (GC)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "F5"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker assigned the Administrator role may be able to bypass Appliance mode restrictions, utilizing command injection vulnerabilities in undisclosed URIs in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.f5.com/csp/article/K68647001",
              "refsource": "MISC",
              "url": "https://support.f5.com/csp/article/K68647001"
            }
          ]
        },
        "source": {
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
    "assignerShortName": "f5",
    "cveId": "CVE-2022-27806",
    "datePublished": "2022-05-05T16:29:58.078244Z",
    "dateReserved": "2022-04-19T00:00:00",
    "dateUpdated": "2024-09-17T01:36:21.373Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25946 (GCVE-0-2022-25946)

Vulnerability from cvelistv5 – Published: 2022-05-05 16:21 – Updated: 2024-09-17 03:28
VLAI?
Summary
On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker with Administrator role privilege may be able to bypass Appliance mode restrictions due to a missing integrity check in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
CWE
  • CWE-354 - Improper Validation of Integrity Check Value
Assigner
f5
References
Impacted products
Vendor Product Version
F5 BIG-IP (Advanced WAF, APM, ASM) Affected: 16.1.x
Affected: 15.1.x
Affected: 14.1.x
Affected: 13.1.x
Affected: 12.1.x
Affected: 11.6.x
Unaffected: 17.0.0 , < 17.0.x* (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:44.326Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.f5.com/csp/article/K52322100"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BIG-IP (Advanced WAF, APM, ASM)",
          "vendor": "F5",
          "versions": [
            {
              "status": "affected",
              "version": "16.1.x"
            },
            {
              "status": "affected",
              "version": "15.1.x"
            },
            {
              "status": "affected",
              "version": "14.1.x"
            },
            {
              "status": "affected",
              "version": "13.1.x"
            },
            {
              "status": "affected",
              "version": "12.1.x"
            },
            {
              "status": "affected",
              "version": "11.6.x"
            },
            {
              "lessThan": "17.0.x*",
              "status": "unaffected",
              "version": "17.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "BIG-IP Guided Configuration (GC)",
          "vendor": "F5",
          "versions": [
            {
              "lessThan": "9.0",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-05-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker with Administrator role privilege may be able to bypass Appliance mode restrictions due to a missing integrity check in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-354",
              "description": "CWE-354 Improper Validation of Integrity Check Value",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-05T16:21:26",
        "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "shortName": "f5"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.f5.com/csp/article/K52322100"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "f5sirt@f5.com",
          "DATE_PUBLIC": "2022-05-04T14:00:00.000Z",
          "ID": "CVE-2022-25946",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BIG-IP (Advanced WAF, APM, ASM)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "!\u003e=",
                            "version_name": "17.0.x",
                            "version_value": "17.0.0"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "16.1.x",
                            "version_value": "16.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "15.1.x",
                            "version_value": "15.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "14.1.x",
                            "version_value": "14.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "13.1.x",
                            "version_value": "13.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "12.1.x",
                            "version_value": "12.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "11.6.x",
                            "version_value": "11.6.x"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "BIG-IP Guided Configuration (GC)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "F5"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker with Administrator role privilege may be able to bypass Appliance mode restrictions due to a missing integrity check in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-354 Improper Validation of Integrity Check Value"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.f5.com/csp/article/K52322100",
              "refsource": "MISC",
              "url": "https://support.f5.com/csp/article/K52322100"
            }
          ]
        },
        "source": {
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
    "assignerShortName": "f5",
    "cveId": "CVE-2022-25946",
    "datePublished": "2022-05-05T16:21:26.941651Z",
    "dateReserved": "2022-04-19T00:00:00",
    "dateUpdated": "2024-09-17T03:28:41.853Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-27806 (GCVE-0-2022-27806)

Vulnerability from nvd – Published: 2022-05-05 16:29 – Updated: 2024-09-17 01:36
VLAI?
Summary
On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker assigned the Administrator role may be able to bypass Appliance mode restrictions, utilizing command injection vulnerabilities in undisclosed URIs in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
f5
References
Impacted products
Vendor Product Version
F5 BIG-IP (Advanced WAF, APM, ASM) Affected: 16.1.x
Affected: 15.1.x
Affected: 14.1.x
Affected: 13.1.x
Affected: 12.1.x
Affected: 11.6.x
Unaffected: 17.0.0 , < 17.0.x* (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:32:59.981Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.f5.com/csp/article/K68647001"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BIG-IP (Advanced WAF, APM, ASM)",
          "vendor": "F5",
          "versions": [
            {
              "status": "affected",
              "version": "16.1.x"
            },
            {
              "status": "affected",
              "version": "15.1.x"
            },
            {
              "status": "affected",
              "version": "14.1.x"
            },
            {
              "status": "affected",
              "version": "13.1.x"
            },
            {
              "status": "affected",
              "version": "12.1.x"
            },
            {
              "status": "affected",
              "version": "11.6.x"
            },
            {
              "lessThan": "17.0.x*",
              "status": "unaffected",
              "version": "17.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "BIG-IP Guided Configuration (GC)",
          "vendor": "F5",
          "versions": [
            {
              "lessThan": "9.0",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-05-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker assigned the Administrator role may be able to bypass Appliance mode restrictions, utilizing command injection vulnerabilities in undisclosed URIs in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-05T16:29:58",
        "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "shortName": "f5"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.f5.com/csp/article/K68647001"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "f5sirt@f5.com",
          "DATE_PUBLIC": "2022-05-04T14:00:00.000Z",
          "ID": "CVE-2022-27806",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BIG-IP (Advanced WAF, APM, ASM)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "!\u003e=",
                            "version_name": "17.0.x",
                            "version_value": "17.0.0"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "16.1.x",
                            "version_value": "16.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "15.1.x",
                            "version_value": "15.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "14.1.x",
                            "version_value": "14.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "13.1.x",
                            "version_value": "13.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "12.1.x",
                            "version_value": "12.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "11.6.x",
                            "version_value": "11.6.x"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "BIG-IP Guided Configuration (GC)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "F5"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker assigned the Administrator role may be able to bypass Appliance mode restrictions, utilizing command injection vulnerabilities in undisclosed URIs in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.f5.com/csp/article/K68647001",
              "refsource": "MISC",
              "url": "https://support.f5.com/csp/article/K68647001"
            }
          ]
        },
        "source": {
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
    "assignerShortName": "f5",
    "cveId": "CVE-2022-27806",
    "datePublished": "2022-05-05T16:29:58.078244Z",
    "dateReserved": "2022-04-19T00:00:00",
    "dateUpdated": "2024-09-17T01:36:21.373Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25946 (GCVE-0-2022-25946)

Vulnerability from nvd – Published: 2022-05-05 16:21 – Updated: 2024-09-17 03:28
VLAI?
Summary
On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker with Administrator role privilege may be able to bypass Appliance mode restrictions due to a missing integrity check in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
CWE
  • CWE-354 - Improper Validation of Integrity Check Value
Assigner
f5
References
Impacted products
Vendor Product Version
F5 BIG-IP (Advanced WAF, APM, ASM) Affected: 16.1.x
Affected: 15.1.x
Affected: 14.1.x
Affected: 13.1.x
Affected: 12.1.x
Affected: 11.6.x
Unaffected: 17.0.0 , < 17.0.x* (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:44.326Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.f5.com/csp/article/K52322100"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BIG-IP (Advanced WAF, APM, ASM)",
          "vendor": "F5",
          "versions": [
            {
              "status": "affected",
              "version": "16.1.x"
            },
            {
              "status": "affected",
              "version": "15.1.x"
            },
            {
              "status": "affected",
              "version": "14.1.x"
            },
            {
              "status": "affected",
              "version": "13.1.x"
            },
            {
              "status": "affected",
              "version": "12.1.x"
            },
            {
              "status": "affected",
              "version": "11.6.x"
            },
            {
              "lessThan": "17.0.x*",
              "status": "unaffected",
              "version": "17.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "BIG-IP Guided Configuration (GC)",
          "vendor": "F5",
          "versions": [
            {
              "lessThan": "9.0",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-05-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker with Administrator role privilege may be able to bypass Appliance mode restrictions due to a missing integrity check in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-354",
              "description": "CWE-354 Improper Validation of Integrity Check Value",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-05T16:21:26",
        "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "shortName": "f5"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.f5.com/csp/article/K52322100"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "f5sirt@f5.com",
          "DATE_PUBLIC": "2022-05-04T14:00:00.000Z",
          "ID": "CVE-2022-25946",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BIG-IP (Advanced WAF, APM, ASM)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "!\u003e=",
                            "version_name": "17.0.x",
                            "version_value": "17.0.0"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "16.1.x",
                            "version_value": "16.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "15.1.x",
                            "version_value": "15.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "14.1.x",
                            "version_value": "14.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "13.1.x",
                            "version_value": "13.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "12.1.x",
                            "version_value": "12.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "11.6.x",
                            "version_value": "11.6.x"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "BIG-IP Guided Configuration (GC)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "F5"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker with Administrator role privilege may be able to bypass Appliance mode restrictions due to a missing integrity check in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-354 Improper Validation of Integrity Check Value"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.f5.com/csp/article/K52322100",
              "refsource": "MISC",
              "url": "https://support.f5.com/csp/article/K52322100"
            }
          ]
        },
        "source": {
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
    "assignerShortName": "f5",
    "cveId": "CVE-2022-25946",
    "datePublished": "2022-05-05T16:21:26.941651Z",
    "dateReserved": "2022-04-19T00:00:00",
    "dateUpdated": "2024-09-17T03:28:41.853Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}