All the vulnerabilites related to Rockwell Automation - Compact GuardLogix® 5380 controllers
cve-2024-8626
Vulnerability from cvelistv5
Published
2024-10-08 16:35
Modified
2024-10-08 17:36
Severity ?
EPSS score ?
Summary
Logix Controllers Vulnerable to Denial-of-Service Vulnerability
References
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "compactlogix_5380_firmware", "vendor": "rockwellautomation", "versions": [ { "lessThan": "33.015", "status": "affected", "version": "33.011", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "compact_guardlogix_5380_firmware", "vendor": "rockwellautomation", "versions": [ { "lessThan": "33.015", "status": "affected", "version": "33.011", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "compactlogix_5480_firmware", "vendor": "rockwellautomation", "versions": [ { "lessThan": "33.015", "status": "affected", "version": "33.011", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "guardlogix_5580_firmware", "vendor": "rockwellautomation", "versions": [ { "lessThan": "33.015", "status": "affected", "version": "33.001", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:rockwellautomation:1756-en4tr_firmware:3.002:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "1756-en4tr_firmware", "vendor": "rockwellautomation", "versions": [ { "status": "affected", "version": "3.002" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-8626", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-08T17:29:59.695076Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-08T17:36:25.719Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CompactLogix 5380 controllers", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v33.011 \u003c" } ] }, { "defaultStatus": "unaffected", "product": "Compact GuardLogix\u00ae 5380 controllers", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v33.011\u003c" } ] }, { "defaultStatus": "unaffected", "product": "CompactLogix 5480 controllers", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v33.011\u003c" } ] }, { "defaultStatus": "unaffected", "product": "GuardLogix 5580 controllers", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v33.011\u003c" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN4TR", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v3.002" } ] } ], "datePublic": "2024-10-08T16:24:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDue to a memory leak, a denial-of-service vulnerability exists in the Rockwell Automation affected products. A malicious actor could exploit this vulnerability by performing multiple actions on certain web pages of the product causing the affected products to become fully unavailable and require a power cycle to recover. \u003c/span\u003e" } ], "value": "Due to a memory leak, a denial-of-service vulnerability exists in the Rockwell Automation affected products. A malicious actor could exploit this vulnerability by performing multiple actions on certain web pages of the product causing the affected products to become fully unavailable and require a power cycle to recover." } ], "impacts": [ { "capecId": "CAPEC-124", "descriptions": [ { "lang": "en", "value": "CAPEC-124 Shared Resource Manipulation" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 8.7, "baseSeverity": "HIGH", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400 Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-08T16:35:04.513Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1706.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003cbr\u003eAffected Product\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eFirst Known in firmware Revision\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCorrected in Firmware Revision\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompactLogix 5380 controllers\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.011 \u0026lt;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd rowspan=\"5\"\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003ev33.015 and later for versions 33\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003ev34.011 and later\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompact GuardLogix\u00ae 5380 controllers\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.011\u0026lt;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompactLogix 5480 controllers\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.011\u0026lt;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eControlLogix 5580 controllers\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.011\u0026lt;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eGuardLogix 5580 controllers\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.011\u0026lt;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e1756-EN4TR\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev3.002\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e4.001 and later\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cbr\u003e\n\n\u003cp\u003eMitigations and Workarounds \u003c/p\u003e\u003cp\u003eCustomers using the affected versions are encouraged to upgrade to corrected firmware versions. We also strongly encourage customers to implement our suggested security best practices to minimize the risk of the vulnerability. \u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u0026nbsp;\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e" } ], "value": "Affected Product\u00a0\n\n\u00a0\n\n\u00a0\n\nFirst Known in firmware Revision\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCorrected in Firmware Revision\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompactLogix 5380 controllers\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.011 \u003c\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n * v33.015 and later for versions 33\n\n\n\n\n\u00a0\n\n\u00a0\n\n * v34.011 and later\n\n\n\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompact GuardLogix\u00ae 5380 controllers\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.011\u003c\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompactLogix 5480 controllers\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.011\u003c\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nControlLogix 5580 controllers\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.011\u003c\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nGuardLogix 5580 controllers\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.011\u003c\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n1756-EN4TR\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv3.002\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n * 4.001 and later\n\n\n\n\n\u00a0\n\n\u00a0\n\n\n\n\nMitigations and Workarounds \n\nCustomers using the affected versions are encouraged to upgrade to corrected firmware versions. We also strongly encourage customers to implement our suggested security best practices to minimize the risk of the vulnerability. \n\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight" } ], "source": { "advisory": "SD1706", "discovery": "EXTERNAL" }, "title": "Logix Controllers Vulnerable to Denial-of-Service Vulnerability", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2024-8626", "datePublished": "2024-10-08T16:35:04.513Z", "dateReserved": "2024-09-09T20:33:30.575Z", "dateUpdated": "2024-10-08T17:36:25.719Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }