Search criteria

4 vulnerabilities found for Connex Health Portal by Baxter

CVE-2024-6796 (GCVE-0-2024-6796)

Vulnerability from cvelistv5 – Published: 2024-09-09 19:28 – Updated: 2024-09-09 20:08
VLAI?
Title
Vulnerability in Baxter Connex Health Portal
Summary
In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal's database and/or modify content.
CWE
  • CWE-284 - Improper Access Control
Assigner
Impacted products
Vendor Product Version
Baxter Connex Health Portal Affected: 0 , < 8/30/2024 (date)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:hillrom:connex_health_portal:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "connex_health_portal",
            "vendor": "hillrom",
            "versions": [
              {
                "lessThan": "8.30.2024",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6796",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-09T19:51:44.387310Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-09T20:08:22.237Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Connex Health Portal",
          "vendor": "Baxter",
          "versions": [
            {
              "lessThan": "8/30/2024",
              "status": "affected",
              "version": "0",
              "versionType": "date"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database and/or modify content.\u0026nbsp;"
            }
          ],
          "value": "In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database and/or modify content."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-09T19:28:30.647Z",
        "orgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
        "shortName": "Baxter"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Baxter is unaware of any exploitation of this vulnerability in our product and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Baxter is unaware of any exploitation of this vulnerability in our product and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Vulnerability in Baxter Connex Health Portal",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
    "assignerShortName": "Baxter",
    "cveId": "CVE-2024-6796",
    "datePublished": "2024-09-09T19:28:30.647Z",
    "dateReserved": "2024-07-16T17:54:05.755Z",
    "dateUpdated": "2024-09-09T20:08:22.237Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-6795 (GCVE-0-2024-6795)

Vulnerability from cvelistv5 – Published: 2024-09-09 19:24 – Updated: 2024-09-09 20:08
VLAI?
Title
Vulnerability in Baxter Connex Health Portal
Summary
In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal's database.  An attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content and/or perform administrative operations including shutting down the database.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Vendor Product Version
Baxter Connex Health Portal Affected: 0 , < 8/30/2024 (date)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:hillrom:connex_health_portal:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "connex_health_portal",
            "vendor": "hillrom",
            "versions": [
              {
                "lessThan": "8.30.2024",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6795",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-09T20:04:42.779977Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-09T20:08:01.134Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Connex Health Portal",
          "vendor": "Baxter",
          "versions": [
            {
              "lessThan": "8/30/2024",
              "status": "affected",
              "version": "0",
              "versionType": "date"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database.\u0026nbsp;\n\nAn attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content \n\nand/or perform administrative operations including shutting down the database."
            }
          ],
          "value": "In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database.\u00a0\n\nAn attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content \n\nand/or perform administrative operations including shutting down the database."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-23",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-23 File Content Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-09T19:24:01.776Z",
        "orgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
        "shortName": "Baxter"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Baxter is unaware of any exploitation of this vulnerability and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required.\u003cbr\u003e"
            }
          ],
          "value": "Baxter is unaware of any exploitation of this vulnerability and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Vulnerability in Baxter Connex Health Portal",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
    "assignerShortName": "Baxter",
    "cveId": "CVE-2024-6795",
    "datePublished": "2024-09-09T19:24:01.776Z",
    "dateReserved": "2024-07-16T17:54:02.625Z",
    "dateUpdated": "2024-09-09T20:08:01.134Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-6796 (GCVE-0-2024-6796)

Vulnerability from nvd – Published: 2024-09-09 19:28 – Updated: 2024-09-09 20:08
VLAI?
Title
Vulnerability in Baxter Connex Health Portal
Summary
In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal's database and/or modify content.
CWE
  • CWE-284 - Improper Access Control
Assigner
Impacted products
Vendor Product Version
Baxter Connex Health Portal Affected: 0 , < 8/30/2024 (date)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:hillrom:connex_health_portal:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "connex_health_portal",
            "vendor": "hillrom",
            "versions": [
              {
                "lessThan": "8.30.2024",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6796",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-09T19:51:44.387310Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-09T20:08:22.237Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Connex Health Portal",
          "vendor": "Baxter",
          "versions": [
            {
              "lessThan": "8/30/2024",
              "status": "affected",
              "version": "0",
              "versionType": "date"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database and/or modify content.\u0026nbsp;"
            }
          ],
          "value": "In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database and/or modify content."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-09T19:28:30.647Z",
        "orgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
        "shortName": "Baxter"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Baxter is unaware of any exploitation of this vulnerability in our product and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Baxter is unaware of any exploitation of this vulnerability in our product and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Vulnerability in Baxter Connex Health Portal",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
    "assignerShortName": "Baxter",
    "cveId": "CVE-2024-6796",
    "datePublished": "2024-09-09T19:28:30.647Z",
    "dateReserved": "2024-07-16T17:54:05.755Z",
    "dateUpdated": "2024-09-09T20:08:22.237Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-6795 (GCVE-0-2024-6795)

Vulnerability from nvd – Published: 2024-09-09 19:24 – Updated: 2024-09-09 20:08
VLAI?
Title
Vulnerability in Baxter Connex Health Portal
Summary
In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal's database.  An attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content and/or perform administrative operations including shutting down the database.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Vendor Product Version
Baxter Connex Health Portal Affected: 0 , < 8/30/2024 (date)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:hillrom:connex_health_portal:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "connex_health_portal",
            "vendor": "hillrom",
            "versions": [
              {
                "lessThan": "8.30.2024",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6795",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-09T20:04:42.779977Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-09T20:08:01.134Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Connex Health Portal",
          "vendor": "Baxter",
          "versions": [
            {
              "lessThan": "8/30/2024",
              "status": "affected",
              "version": "0",
              "versionType": "date"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database.\u0026nbsp;\n\nAn attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content \n\nand/or perform administrative operations including shutting down the database."
            }
          ],
          "value": "In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal\u0027s database.\u00a0\n\nAn attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content \n\nand/or perform administrative operations including shutting down the database."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-23",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-23 File Content Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-09T19:24:01.776Z",
        "orgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
        "shortName": "Baxter"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Baxter is unaware of any exploitation of this vulnerability and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required.\u003cbr\u003e"
            }
          ],
          "value": "Baxter is unaware of any exploitation of this vulnerability and/or the compromise of personal or health data. Baxter patched all impacted systems promptly to address this vulnerability. No user action is required."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Vulnerability in Baxter Connex Health Portal",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
    "assignerShortName": "Baxter",
    "cveId": "CVE-2024-6795",
    "datePublished": "2024-09-09T19:24:01.776Z",
    "dateReserved": "2024-07-16T17:54:02.625Z",
    "dateUpdated": "2024-09-09T20:08:01.134Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}