Search criteria

2 vulnerabilities found for Control-M/Server by BMC

CVE-2025-48709 (GCVE-0-2025-48709)

Vulnerability from cvelistv5 – Published: 2025-08-07 00:00 – Updated: 2025-12-01 21:57
VLAI
Title
BMC Control-M/Server cleartext database credentials in process lists and logs
Summary
BMC Control-M/Server 9.0.21.300 displays cleartext database credentials in process lists and logs. An authenticated attacker with shell access could observe these credentials and use them to log in to the database server. For example, when Control-M/Server on Windows has a database connection on, it runs 'DBUStatus.exe' frequently, which then calls 'dbu_connection_details.vbs' with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations. Fixed in PACTV.9.0.21.307.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
  • CWE-214 - Invocation of Process Using Visible Sensitive Information
Assigner
Impacted products
Vendor Product Version
BMC Control-M/Server Affected: 9.0.21.300 , < PACTV.9.0.21.307 (custom)
Unaffected: PACTV.9.0.21.307
Create a notification for this product.
bmc control-m Affected: 9.0.21.300 , < 9.0.21.300 PACTV.9.0.21.307 (custom)
Unaffected: PACTV.9.0.21.307
    cpe:2.3:a:bmc:control-m:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2025-08-06 00:00
Credits
Derrick Polakoff
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:bmc:control-m:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "control-m",
            "vendor": "bmc",
            "versions": [
              {
                "lessThan": "9.0.21.300 PACTV.9.0.21.307",
                "status": "affected",
                "version": "9.0.21.300",
                "versionType": "custom"
              },
              {
                "status": "unaffected",
                "version": "PACTV.9.0.21.307"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-48709",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-27T15:23:04.978628Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-01T21:57:06.906Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Control-M/Server",
          "vendor": "BMC",
          "versions": [
            {
              "lessThan": "PACTV.9.0.21.307",
              "status": "affected",
              "version": "9.0.21.300",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "PACTV.9.0.21.307"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Derrick Polakoff"
        }
      ],
      "datePublic": "2025-08-06T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "BMC Control-M/Server 9.0.21.300 displays cleartext database credentials in process lists and logs. An authenticated attacker with shell access could observe these credentials and use them to log in to the database server. For example, when Control-M/Server on Windows has a database connection on, it runs \u0027DBUStatus.exe\u0027 frequently, which then calls \u0027dbu_connection_details.vbs\u0027 with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations. Fixed in PACTV.9.0.21.307."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE"
          }
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "other": {
            "content": {
              "id": "CVE-2025-48709",
              "options": [
                {
                  "Exploitation": "poc"
                },
                {
                  "Automatable": "no"
                },
                {
                  "Technical Impact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-10-02T16:23:53.246063Z",
              "version": "2.0.3"
            },
            "type": "ssvc"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-214",
              "description": "CWE-214 Invocation of Process Using Visible Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-01T21:20:49.549Z",
        "orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
        "shortName": "cisa-cg"
      },
      "references": [
        {
          "name": "url",
          "url": "https://docs.bmc.com/xwiki/bin/view/Control-M-Orchestration/Control-M/ctm9021/Patches/Control-M-Server-PACTV-9-0-21-307/"
        }
      ],
      "title": "BMC Control-M/Server cleartext database credentials in process lists and logs"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-48709",
    "datePublished": "2025-08-07T00:00:00.000Z",
    "dateReserved": "2025-05-23T00:00:00.000Z",
    "dateUpdated": "2025-12-01T21:57:06.906Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-48709 (GCVE-0-2025-48709)

Vulnerability from nvd – Published: 2025-08-07 00:00 – Updated: 2025-12-01 21:57
VLAI
Title
BMC Control-M/Server cleartext database credentials in process lists and logs
Summary
BMC Control-M/Server 9.0.21.300 displays cleartext database credentials in process lists and logs. An authenticated attacker with shell access could observe these credentials and use them to log in to the database server. For example, when Control-M/Server on Windows has a database connection on, it runs 'DBUStatus.exe' frequently, which then calls 'dbu_connection_details.vbs' with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations. Fixed in PACTV.9.0.21.307.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
  • CWE-214 - Invocation of Process Using Visible Sensitive Information
Assigner
Impacted products
Vendor Product Version
BMC Control-M/Server Affected: 9.0.21.300 , < PACTV.9.0.21.307 (custom)
Unaffected: PACTV.9.0.21.307
Create a notification for this product.
bmc control-m Affected: 9.0.21.300 , < 9.0.21.300 PACTV.9.0.21.307 (custom)
Unaffected: PACTV.9.0.21.307
    cpe:2.3:a:bmc:control-m:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2025-08-06 00:00
Credits
Derrick Polakoff
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:bmc:control-m:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "control-m",
            "vendor": "bmc",
            "versions": [
              {
                "lessThan": "9.0.21.300 PACTV.9.0.21.307",
                "status": "affected",
                "version": "9.0.21.300",
                "versionType": "custom"
              },
              {
                "status": "unaffected",
                "version": "PACTV.9.0.21.307"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-48709",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-27T15:23:04.978628Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-01T21:57:06.906Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Control-M/Server",
          "vendor": "BMC",
          "versions": [
            {
              "lessThan": "PACTV.9.0.21.307",
              "status": "affected",
              "version": "9.0.21.300",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "PACTV.9.0.21.307"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Derrick Polakoff"
        }
      ],
      "datePublic": "2025-08-06T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "BMC Control-M/Server 9.0.21.300 displays cleartext database credentials in process lists and logs. An authenticated attacker with shell access could observe these credentials and use them to log in to the database server. For example, when Control-M/Server on Windows has a database connection on, it runs \u0027DBUStatus.exe\u0027 frequently, which then calls \u0027dbu_connection_details.vbs\u0027 with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations. Fixed in PACTV.9.0.21.307."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE"
          }
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "other": {
            "content": {
              "id": "CVE-2025-48709",
              "options": [
                {
                  "Exploitation": "poc"
                },
                {
                  "Automatable": "no"
                },
                {
                  "Technical Impact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-10-02T16:23:53.246063Z",
              "version": "2.0.3"
            },
            "type": "ssvc"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-214",
              "description": "CWE-214 Invocation of Process Using Visible Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-01T21:20:49.549Z",
        "orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
        "shortName": "cisa-cg"
      },
      "references": [
        {
          "name": "url",
          "url": "https://docs.bmc.com/xwiki/bin/view/Control-M-Orchestration/Control-M/ctm9021/Patches/Control-M-Server-PACTV-9-0-21-307/"
        }
      ],
      "title": "BMC Control-M/Server cleartext database credentials in process lists and logs"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-48709",
    "datePublished": "2025-08-07T00:00:00.000Z",
    "dateReserved": "2025-05-23T00:00:00.000Z",
    "dateUpdated": "2025-12-01T21:57:06.906Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}