All the vulnerabilites related to Rockwell Automation - ControlLogix® 5570
cve-2024-21916
Vulnerability from cvelistv5
Published
2024-01-31 18:28
Modified
2024-08-01 22:35
Severity ?
EPSS score ?
Summary
Rockwell Automation Denial-of-service Vulnerability in ICE1 Controller
References
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "controllogix_5570_controller_firmware", "vendor": "rockwellautomation", "versions": [ { "status": "affected", "version": "20.011" } ] }, { "cpes": [ "cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "guardlogix_5570_controller_firmware", "vendor": "rockwellautomation", "versions": [ { "status": "affected", "version": "20.011" } ] }, { "cpes": [ "cpe:2.3:o:rockwellautomation:controllogix_5570_redundant_controller_firmware:20.054_kit1:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "controllogix_5570_redundant_controller_firmware", "vendor": "rockwellautomation", "versions": [ { "status": "affected", "version": "20.054_kit1" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-21916", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-02-06T05:00:32.025684Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-01T19:54:41.466Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T22:35:34.618Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ControlLogix\u00ae 5570", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "20.011" } ] }, { "defaultStatus": "unaffected", "product": "GuardLogix\u00ae 5570", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "20.011" } ] }, { "defaultStatus": "unaffected", "product": "ControlLogix\u00ae 5570 redundant", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "20.054_kit1" } ] } ], "datePublic": "2024-01-30T14:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMNRF.\u003c/a\u003e" } ], "value": "\nA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF." } ], "impacts": [ { "capecId": "CAPEC-100", "descriptions": [ { "lang": "en", "value": "CAPEC-100 Overflow Buffers" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-31T18:28:59.715Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cul\u003e\u003cli\u003eUpdate to corrected Firmware.\u0026nbsp;\u003c/li\u003e\u003c/ul\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eAffected Product\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eFirst Known in Firmware\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in Firmware\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\u00ae 5570\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.016, 34.013, 35.012, 36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eGuardLogix\u00ae 5570\u003cb\u003e\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.016, 34.013, 35.012, 36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\u00ae 5570 redundant\u003cb\u003e\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.054_kit1\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.053_kit1, 34.052_kit1, 35.052_kit1, 36.051_kit1 and late\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\n\n\u003cbr\u003e\n\n" } ], "value": "\n * Update to corrected Firmware.\u00a0\n\n\n\n\nAffected Product\n\nFirst Known in Firmware\n\nCorrected in Firmware\n\nControlLogix\u00ae 5570\n\n20.011\n\nv33.016, 34.013, 35.012, 36.011 and later\n\nGuardLogix\u00ae 5570\n\n20.011\n\nv33.016, 34.013, 35.012, 36.011 and later\n\nControlLogix\u00ae 5570 redundant\n\n20.054_kit1\n\nv33.053_kit1, 34.052_kit1, 35.052_kit1, 36.051_kit1 and late\n\n\n\n\n\n\n" } ], "source": { "discovery": "UNKNOWN" }, "title": "Rockwell Automation Denial-of-service Vulnerability in ICE1 Controller", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2024-21916", "datePublished": "2024-01-31T18:28:59.715Z", "dateReserved": "2024-01-03T16:40:50.367Z", "dateUpdated": "2024-08-01T22:35:34.618Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }