Search criteria
5 vulnerabilities found for Controller BACnet/IP by WAGO
CVE-2018-25090 (GCVE-0-2018-25090)
Vulnerability from cvelistv5 – Published: 2024-03-13 08:32 – Updated: 2024-08-05 15:22- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | Controller BACnet/IP |
Affected:
0 , ≤ FW13
(semver)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:33:48.504Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2018-25090",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-05T15:21:55.909544Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-05T15:22:05.933Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Controller BACnet/IP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Controller BACnet MS/TP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Fieldbus Coupler Ethernet 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required.\u0026nbsp;This leads to a limited impact of confidentiality and integrity but no impact of availability."
}
],
"value": "An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required.\u00a0This leads to a limited impact of confidentiality and integrity but no impact of availability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T08:32:17.180Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"source": {
"advisory": "VDE-2023-039",
"defect": [
"CERT@VDE#64546"
],
"discovery": "EXTERNAL"
},
"title": "Wago: Improper Neutralization of Input During Web Page Generation in multiple devices",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2018-25090",
"datePublished": "2024-03-13T08:32:17.180Z",
"dateReserved": "2023-09-14T13:00:21.075Z",
"dateUpdated": "2024-08-05T15:22:05.933Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-10123 (GCVE-0-2015-10123)
Vulnerability from cvelistv5 – Published: 2024-03-13 08:31 – Updated: 2024-10-23 09:40- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | Controller BACnet/IP |
Affected:
0 , ≤ FW13
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T08:58:26.532Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:wago:750-352_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-352_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-831_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-831_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-829_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-829_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-852_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-852_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-880_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-880_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-881_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-881_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-882_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-882_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-885_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-885_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-889_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-889_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-884_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-884_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2015-10123",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-06T18:34:04.204030Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-06T19:37:09.871Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Controller BACnet/IP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Controller BACnet MS/TP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Fieldbus Coupler Ethernet 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device.\u003cbr\u003e"
}
],
"value": "An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T09:40:12.408Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"source": {
"advisory": "VDE-2023-039",
"defect": [
"CERT@VDE#64546"
],
"discovery": "EXTERNAL"
},
"title": "Wago: Buffer Copy without Checking Size of Input in wbm of multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2015-10123",
"datePublished": "2024-03-13T08:31:55.341Z",
"dateReserved": "2023-09-14T13:00:03.904Z",
"dateUpdated": "2024-10-23T09:40:12.408Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-25090 (GCVE-0-2018-25090)
Vulnerability from nvd – Published: 2024-03-13 08:32 – Updated: 2024-08-05 15:22- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | Controller BACnet/IP |
Affected:
0 , ≤ FW13
(semver)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:33:48.504Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2018-25090",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-05T15:21:55.909544Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-05T15:22:05.933Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Controller BACnet/IP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Controller BACnet MS/TP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Fieldbus Coupler Ethernet 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required.\u0026nbsp;This leads to a limited impact of confidentiality and integrity but no impact of availability."
}
],
"value": "An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required.\u00a0This leads to a limited impact of confidentiality and integrity but no impact of availability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T08:32:17.180Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"source": {
"advisory": "VDE-2023-039",
"defect": [
"CERT@VDE#64546"
],
"discovery": "EXTERNAL"
},
"title": "Wago: Improper Neutralization of Input During Web Page Generation in multiple devices",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2018-25090",
"datePublished": "2024-03-13T08:32:17.180Z",
"dateReserved": "2023-09-14T13:00:21.075Z",
"dateUpdated": "2024-08-05T15:22:05.933Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-10123 (GCVE-0-2015-10123)
Vulnerability from nvd – Published: 2024-03-13 08:31 – Updated: 2024-10-23 09:40- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | Controller BACnet/IP |
Affected:
0 , ≤ FW13
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T08:58:26.532Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:wago:750-352_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-352_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-831_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-831_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-829_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-829_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-852_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-852_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-880_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-880_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-881_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-881_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-882_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-882_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-885_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-885_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-889_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-889_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-884_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-884_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2015-10123",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-06T18:34:04.204030Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-06T19:37:09.871Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Controller BACnet/IP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Controller BACnet MS/TP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Fieldbus Coupler Ethernet 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device.\u003cbr\u003e"
}
],
"value": "An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T09:40:12.408Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"source": {
"advisory": "VDE-2023-039",
"defect": [
"CERT@VDE#64546"
],
"discovery": "EXTERNAL"
},
"title": "Wago: Buffer Copy without Checking Size of Input in wbm of multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2015-10123",
"datePublished": "2024-03-13T08:31:55.341Z",
"dateReserved": "2023-09-14T13:00:03.904Z",
"dateUpdated": "2024-10-23T09:40:12.408Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
VAR-201904-1022
Vulnerability from variot - Updated: 2023-12-18 12:43ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. Programmable Logic Controller Contains a resource exhaustion vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. ABB/Phoenix Contact/Schneider Electric/Siemens/WAGO PLCs are prone to an remote denial-of-service vulnerability. An attacker can exploit this issue to cause a denial of service condition. There are resource management error vulnerabilities in many PLC products, which originate from improper management of system resources (such as memory, disk space, files, etc.) by the network system or products
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201904-1022",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ilc 151 eth",
"scope": "eq",
"trust": 1.0,
"vendor": "phoenixcontact",
"version": null
},
{
"model": "modicon m221",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "1.10.0.0"
},
{
"model": "knx ip",
"scope": "eq",
"trust": 1.0,
"vendor": "wago",
"version": null
},
{
"model": "bacnet\\/ip",
"scope": "eq",
"trust": 1.0,
"vendor": "wago",
"version": null
},
{
"model": "6ed1052-1cc01-0ba8",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "6es7211-1ae40-0xb0",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "6es7314-6eh04-0ab0",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "pm554-tp-eth",
"scope": "eq",
"trust": 1.0,
"vendor": "abb",
"version": null
},
{
"model": "ethernet",
"scope": "eq",
"trust": 1.0,
"vendor": "wago",
"version": null
},
{
"model": "pfc100",
"scope": "eq",
"trust": 1.0,
"vendor": "wago",
"version": null
},
{
"model": "pm554-tp-eth",
"scope": null,
"trust": 0.8,
"vendor": "abb",
"version": null
},
{
"model": "ilc 151 eth",
"scope": null,
"trust": 0.8,
"vendor": "phoenix contact",
"version": null
},
{
"model": "modicon m221",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "6ed1052-1cc01-0ba8",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "6es7211-1ae40-0xb0",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "6es7314-6eh04-0ab0",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "bacnet/ip",
"scope": null,
"trust": 0.8,
"vendor": "wago",
"version": null
},
{
"model": "ethernet",
"scope": null,
"trust": 0.8,
"vendor": "wago",
"version": null
},
{
"model": "knx ip",
"scope": null,
"trust": 0.8,
"vendor": "wago",
"version": null
},
{
"model": "pfc100",
"scope": null,
"trust": 0.8,
"vendor": "wago",
"version": null
},
{
"model": "controller pfc100",
"scope": "eq",
"trust": 0.3,
"vendor": "wago",
"version": "(750-8100)0"
},
{
"model": "controller knx ip",
"scope": "eq",
"trust": 0.3,
"vendor": "wago",
"version": "(750-889)0"
},
{
"model": "controller ethernet",
"scope": "eq",
"trust": 0.3,
"vendor": "wago",
"version": "(750-880)0"
},
{
"model": "controller bacnet/ip",
"scope": "eq",
"trust": 0.3,
"vendor": "wago",
"version": "(750-831)0"
},
{
"model": "6es7314-6eh04-0ab0 simatic s7-314",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "6es7211-1ae40-0xb0 simatic s7-1211",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "6ed1052-1cc01-0ba8 logo!",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "80"
},
{
"model": "modicon m221",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "contact ilc eth",
"scope": "eq",
"trust": 0.3,
"vendor": "phoenix",
"version": "27009741510"
},
{
"model": "1sap120600r0071 pm554-tp-eth",
"scope": "eq",
"trust": 0.3,
"vendor": "abb",
"version": "0"
}
],
"sources": [
{
"db": "BID",
"id": "108413"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003487"
},
{
"db": "NVD",
"id": "CVE-2019-10953"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:abb:pm554-tp-eth_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:abb:pm554-tp-eth:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:phoenixcontact:ilc_151_eth_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:phoenixcontact:ilc_151_eth:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:modicon_m221_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.10.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_m221:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:6es7211-1ae40-0xb0_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:6es7211-1ae40-0xb0:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:6es7314-6eh04-0ab0_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:6es7314-6eh04-0ab0:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:6ed1052-1cc01-0ba8_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:6ed1052-1cc01-0ba8:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:wago:knx_ip_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:wago:knx_ip:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:wago:pfc100_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:wago:pfc100:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:wago:ethernet_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:wago:ethernet:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:wago:bacnet\\/ip_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:wago:bacnet\\/ip:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-10953"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "and Florian Fischer (Hochschule Augsburg), Jan-Ole Malchow (Freie Universita\u0308t Berlin), and Florian Fischer (Hochschule Augsburg) reported this vulnerability to NCCIC.,Matthias Niedermaier (Hochschule Augsburg), Jan-Ole Malchow (Freie Universita\u00c2\u00a8t Berlin)",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201904-770"
}
],
"trust": 0.6
},
"cve": "CVE-2019-10953",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 5.0,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2019-10953",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "VHN-142551",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2019-10953",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-10953",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201904-770",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-142551",
"trust": 0.1,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2019-10953",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-142551"
},
{
"db": "VULMON",
"id": "CVE-2019-10953"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003487"
},
{
"db": "NVD",
"id": "CVE-2019-10953"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-770"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. Programmable Logic Controller Contains a resource exhaustion vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. ABB/Phoenix Contact/Schneider Electric/Siemens/WAGO PLCs are prone to an remote denial-of-service vulnerability. \nAn attacker can exploit this issue to cause a denial of service condition. There are resource management error vulnerabilities in many PLC products, which originate from improper management of system resources (such as memory, disk space, files, etc.) by the network system or products",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-10953"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003487"
},
{
"db": "BID",
"id": "108413"
},
{
"db": "VULHUB",
"id": "VHN-142551"
},
{
"db": "VULMON",
"id": "CVE-2019-10953"
}
],
"trust": 2.07
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ICS CERT",
"id": "ICSA-19-106-03",
"trust": 2.9
},
{
"db": "NVD",
"id": "CVE-2019-10953",
"trust": 2.9
},
{
"db": "BID",
"id": "108413",
"trust": 2.1
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003487",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201904-770",
"trust": 0.7
},
{
"db": "AUSCERT",
"id": "ESB-2019.1312",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-142551",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2019-10953",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-142551"
},
{
"db": "VULMON",
"id": "CVE-2019-10953"
},
{
"db": "BID",
"id": "108413"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003487"
},
{
"db": "NVD",
"id": "CVE-2019-10953"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-770"
}
]
},
"id": "VAR-201904-1022",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-142551"
}
],
"trust": 0.9082869342857144
},
"last_update_date": "2023-12-18T12:43:33.591000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "PM554-TP-ETH",
"trust": 0.8,
"url": "https://new.abb.com/products/1sap120600r0071/pm554-tp-ethac500-prog-logic-controller"
},
{
"title": "Controller - ILC 151 ETH - 2700974",
"trust": 0.8,
"url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2700974\u0026library=usen\u0026pcck=p-08-12-08-07\u0026tab=5\u0026selectedcategory=all"
},
{
"title": "M221 firmware",
"trust": 0.8,
"url": "https://www.schneider-electric.com/en/download/document/m221+firmware+v1.3/"
},
{
"title": "Top Page",
"trust": 0.8,
"url": "https://new.siemens.com/global/en.html"
},
{
"title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
"trust": 0.8,
"url": "https://www.wago.co.jp/"
},
{
"title": "CVE-2019-10953",
"trust": 0.1,
"url": "https://github.com/alaial90/cve-2019-10953 "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-10953"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003487"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-770",
"trust": 1.1
},
{
"problemtype": "CWE-400",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-142551"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003487"
},
{
"db": "NVD",
"id": "CVE-2019-10953"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.6,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-19-106-03"
},
{
"trust": 2.5,
"url": "http://www.securityfocus.com/bid/108413"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-10953"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10953"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/79174"
},
{
"trust": 0.6,
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-106-03"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/770.html"
},
{
"trust": 0.1,
"url": "https://github.com/alaial90/cve-2019-10953"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-142551"
},
{
"db": "VULMON",
"id": "CVE-2019-10953"
},
{
"db": "BID",
"id": "108413"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003487"
},
{
"db": "NVD",
"id": "CVE-2019-10953"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-770"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-142551"
},
{
"db": "VULMON",
"id": "CVE-2019-10953"
},
{
"db": "BID",
"id": "108413"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003487"
},
{
"db": "NVD",
"id": "CVE-2019-10953"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-770"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-04-17T00:00:00",
"db": "VULHUB",
"id": "VHN-142551"
},
{
"date": "2019-04-17T00:00:00",
"db": "VULMON",
"id": "CVE-2019-10953"
},
{
"date": "2019-05-16T00:00:00",
"db": "BID",
"id": "108413"
},
{
"date": "2019-05-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-003487"
},
{
"date": "2019-04-17T15:29:00.843000",
"db": "NVD",
"id": "CVE-2019-10953"
},
{
"date": "2019-04-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201904-770"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-10-02T00:00:00",
"db": "VULHUB",
"id": "VHN-142551"
},
{
"date": "2021-08-19T00:00:00",
"db": "VULMON",
"id": "CVE-2019-10953"
},
{
"date": "2019-05-16T00:00:00",
"db": "BID",
"id": "108413"
},
{
"date": "2019-05-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-003487"
},
{
"date": "2022-01-31T20:48:56.740000",
"db": "NVD",
"id": "CVE-2019-10953"
},
{
"date": "2022-03-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201904-770"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201904-770"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Programmable Logic Controller Vulnerable to resource exhaustion",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-003487"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "resource management error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201904-770"
}
],
"trust": 0.6
}
}