All the vulnerabilites related to Delta Electronics - DIAEnergy
cve-2022-3214
Vulnerability from cvelistv5
Published
2022-09-16 18:05
Modified
2024-08-03 01:00
Severity ?
EPSS score ?
Summary
Delta Electronics DIAEnergy Use of Hard-coded Credentials
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-03 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Delta Electronics | DIAEnergy |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T01:00:10.813Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "DIAEnergy", "vendor": "Delta Electronics", "versions": [ { "lessThan": "1.9.03.009", "status": "affected", "version": "all", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Y4er working with Trend Micro Zero Day Initiative reported this vulnerability to CISA." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eDelta Industrial Automation\u0027s DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to\u0026nbsp;\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e1.9.03.009\u003c/span\u003e\n\n have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution.\u003c/p\u003e" } ], "value": "Delta Industrial Automation\u0027s DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to\u00a0\n\n1.9.03.009\n\n have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "CWE-798 Use of Hard-coded Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-05T22:22:18.986Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-03" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics fixed the reported vulnerability in version 1.9.03.009 and recommends all users update affected systems. Users can \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en-US/Customer-Service\"\u003econtact the front end sales or FAEs\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;to get this version.\u003c/span\u003e\n\n\u003cbr\u003e" } ], "value": "\nDelta Electronics fixed the reported vulnerability in version 1.9.03.009 and recommends all users update affected systems. Users can contact the front end sales or FAEs https://www.deltaww.com/en-US/Customer-Service \u00a0to get this version.\n\n\n" } ], "source": { "discovery": "EXTERNAL" }, "title": "Delta Electronics DIAEnergy Use of Hard-coded Credentials", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-3214", "STATE": "PUBLIC", "TITLE": "Delta Industrial Automation DIAEnergy Use of Hard-coded Credentials" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "DIAEnergy", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "all", "version_value": "1.8.0" } ] } } ] }, "vendor_name": "Delta Industrial Automation" } ] } }, "credit": [ { "lang": "eng", "value": "Y4er working with Trend Micro Zero Day Initiative reported this vulnerability to CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Delta Industrial Automation\u0027s DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Version 1.8.0 and prior have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-798 Use of Hard-coded Credentials" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-03", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-03" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-3214", "datePublished": "2022-09-16T18:05:41", "dateReserved": "2022-09-14T00:00:00", "dateUpdated": "2024-08-03T01:00:10.813Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }