All the vulnerabilites related to Siemens AG - DIGSI 5 engineering software
cve-2019-10930
Vulnerability from cvelistv5
Published
2019-07-11 21:17
Modified
2024-08-04 22:40
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions). A remote attacker could use specially crafted packets sent to port 443/TCP to upload, download or delete files in certain parts of the file system.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens AG | All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules |
Version: All versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T22:40:15.221Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "product": "DIGSI 5 engineering software", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V7.90" } ] }, { "product": "SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V7.90" } ] }, { "product": "SIPROTEC 5 device types 7SS85 and 7KE85", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V8.01" } ] }, { "product": "SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions \u003c V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions \u003c V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions). A remote attacker could use specially crafted packets sent to port 443/TCP to upload, download or delete files in certain parts of the file system." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-552", "description": "CWE-552: Files or Directories Accessible to External Parties", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-10T16:13:01", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-10930", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules", "version": { "version_data": [ { "version_value": "All versions " } ] } }, { "product_name": "DIGSI 5 engineering software", "version": { "version_data": [ { "version_value": "All versions \u003c V7.90" } ] } }, { "product_name": "SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules", "version": { "version_data": [ { "version_value": "All versions \u003c V7.90" } ] } }, { "product_name": "SIPROTEC 5 device types 7SS85 and 7KE85", "version": { "version_data": [ { "version_value": "All versions \u003c V8.01" } ] } }, { "product_name": "SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions \u003c V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions \u003c V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions). A remote attacker could use specially crafted packets sent to port 443/TCP to upload, download or delete files in certain parts of the file system." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-552: Files or Directories Accessible to External Parties" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-10930", "datePublished": "2019-07-11T21:17:47", "dateReserved": "2019-04-08T00:00:00", "dateUpdated": "2024-08-04T22:40:15.221Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-10931
Vulnerability from cvelistv5
Published
2019-07-11 21:17
Modified
2024-08-04 22:40
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens AG | All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules |
Version: All versions |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T22:40:15.283Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "product": "DIGSI 5 engineering software", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V7.90" } ] }, { "product": "SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V7.90" } ] }, { "product": "SIPROTEC 5 device types 7SS85 and 7KE85", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V8.01" } ] }, { "product": "SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V7.59" } ] }, { "product": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V7.59" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions \u003c V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions \u003c V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-248", "description": "CWE-248: Uncaught Exception", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-10T16:15:57", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-10931", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules", "version": { "version_data": [ { "version_value": "All versions " } ] } }, { "product_name": "DIGSI 5 engineering software", "version": { "version_data": [ { "version_value": "All versions \u003c V7.90" } ] } }, { "product_name": "SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules", "version": { "version_data": [ { "version_value": "All versions \u003c V7.90" } ] } }, { "product_name": "SIPROTEC 5 device types 7SS85 and 7KE85", "version": { "version_data": [ { "version_value": "All versions \u003c V8.01" } ] } }, { "product_name": "SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules", "version": { "version_data": [ { "version_value": "All versions \u003c V7.59" } ] } }, { "product_name": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules", "version": { "version_data": [ { "version_value": "All versions \u003c V7.59" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions \u003c V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions \u003c V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-248: Uncaught Exception" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-10931", "datePublished": "2019-07-11T21:17:47", "dateReserved": "2019-04-08T00:00:00", "dateUpdated": "2024-08-04T22:40:15.283Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }