cve-2018-7494
Vulnerability from cvelistv5
Published
2018-02-27 00:00
Modified
2024-08-05 06:31
Severity
Summary
WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length stack buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:31:03.543Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "103179",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/103179"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Delta Electronics WPLSoft",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "WPLSoft, Versions 2.45.0 and prior."
            }
          ]
        }
      ],
      "datePublic": "2018-02-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length stack buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-05-05T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "103179",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/103179"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-02-27T00:00:00",
          "ID": "CVE-2018-7494",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Delta Electronics WPLSoft",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "WPLSoft, Versions 2.45.0 and prior."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length stack buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "103179",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/103179"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-7494",
    "datePublished": "2018-02-27T00:00:00",
    "dateReserved": "2018-02-26T00:00:00",
    "dateUpdated": "2024-08-05T06:31:03.543Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-7507
Vulnerability from cvelistv5
Published
2018-05-04 19:00
Modified
2024-09-16 17:43
Severity
Summary
WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length heap buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:31:04.137Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "103179",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/103179"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Delta Electronics WPLSoft",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "WPLSoft, Versions 2.45.0 and prior."
            }
          ]
        }
      ],
      "datePublic": "2018-02-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length heap buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-05-05T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "103179",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/103179"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-02-27T00:00:00",
          "ID": "CVE-2018-7507",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Delta Electronics WPLSoft",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "WPLSoft, Versions 2.45.0 and prior."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length heap buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "103179",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/103179"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-7507",
    "datePublished": "2018-05-04T19:00:00Z",
    "dateReserved": "2018-02-26T00:00:00",
    "dateUpdated": "2024-09-16T17:43:16.317Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-7509
Vulnerability from cvelistv5
Published
2018-05-04 19:00
Modified
2024-09-16 18:23
Severity
Summary
WPLSoft in Delta Electronics versions 2.45.0 and prior writes data from a file outside the bounds of the intended buffer space, which could cause memory corruption or may allow remote code execution.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:31:04.379Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "103179",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/103179"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Delta Electronics WPLSoft",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "WPLSoft, Versions 2.45.0 and prior."
            }
          ]
        }
      ],
      "datePublic": "2018-02-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "WPLSoft in Delta Electronics versions 2.45.0 and prior writes data from a file outside the bounds of the intended buffer space, which could cause memory corruption or may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "OUT-OF-BOUNDS WRITE CWE-787",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-05-05T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "103179",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/103179"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-02-27T00:00:00",
          "ID": "CVE-2018-7509",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Delta Electronics WPLSoft",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "WPLSoft, Versions 2.45.0 and prior."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WPLSoft in Delta Electronics versions 2.45.0 and prior writes data from a file outside the bounds of the intended buffer space, which could cause memory corruption or may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OUT-OF-BOUNDS WRITE CWE-787"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "103179",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/103179"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-7509",
    "datePublished": "2018-05-04T19:00:00Z",
    "dateReserved": "2018-02-26T00:00:00",
    "dateUpdated": "2024-09-16T18:23:50.927Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}