All the vulnerabilites related to Frauscher Sensortechnik - Diagnostic System FDS101 for FAdC/FAdCi
cve-2023-2880
Vulnerability from cvelistv5
Published
2023-07-05 09:04
Modified
2024-11-20 21:26
Severity ?
EPSS score ?
Summary
Frauscher Sensortechnik Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T06:41:02.358Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert.vde.com/en/advisories/VDE-2023-011/" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-2880", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-20T21:26:00.294473Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-20T21:26:10.093Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Diagnostic System FDS101 for FAdC/FAdCi", "vendor": "Frauscher Sensortechnik", "versions": [ { "lessThanOrEqual": "1.3.3", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device." } ], "value": "Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-05T09:04:28.091Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2023-011/" } ], "source": { "advisory": "VDE-2023-011", "defect": [ "CERT@VDE#64526" ], "discovery": "INTERNAL" }, "title": "Frauscher Sensortechnik Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2023-2880", "datePublished": "2023-07-05T09:04:28.091Z", "dateReserved": "2023-05-25T07:17:13.633Z", "dateUpdated": "2024-11-20T21:26:10.093Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }