CVE-2024-13967 (GCVE-0-2024-13967)

Vulnerability from cvelistv5 – Published: 2025-06-04 08:01 – Updated: 2025-06-17 11:46
VLAI?
Summary
This vulnerability allows the successful attacker to gain unauthorized access to a configuration web page delivered by the integrated web Server of EIBPORT. This issue affects EIBPORT V3 KNX: through 3.9.8; EIBPORT V3 KNX GSM: through 3.9.8.
CWE
Assigner
ABB
Impacted products
Vendor Product Version
ABB EIBPORT V3 KNX Affected: 0 , ≤ 3.9.8 (custom)
Create a notification for this product.
    ABB EIBPORT V3 KNX GSM Affected: 0 , ≤ 3.9.8 (custom)
Create a notification for this product.
Credits
Psytester for describing the findings and helping to verify the resolving implementation Frank van den Hurk for working with us to help protect customers
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-13967",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-04T13:28:21.636579Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-04T13:28:36.576Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EIBPORT V3 KNX",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.9.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EIBPORT V3  KNX GSM",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.9.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Psytester for describing the findings and helping to verify the resolving implementation"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Frank van den Hurk for working with us to help protect customers"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "This vulnerability allows the successful attacker to gain unauthorized access to a \nconfiguration web page delivered by the integrated web Server of EIBPORT.\n\n\u003cp\u003eThis issue affects EIBPORT V3 KNX: through 3.9.8; EIBPORT V3 KNX GSM: through 3.9.8.\u003c/p\u003e"
            }
          ],
          "value": "This vulnerability allows the successful attacker to gain unauthorized access to a \nconfiguration web page delivered by the integrated web Server of EIBPORT.\n\nThis issue affects EIBPORT V3 KNX: through 3.9.8; EIBPORT V3 KNX GSM: through 3.9.8."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-384",
              "description": "CWE-384 Session Fixation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-17T11:46:53.508Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A1621\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ession-Management Failure",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2024-13967",
    "datePublished": "2025-06-04T08:01:43.117Z",
    "dateReserved": "2025-06-04T07:03:43.612Z",
    "dateUpdated": "2025-06-17T11:46:53.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-13967 (GCVE-0-2024-13967)

Vulnerability from nvd – Published: 2025-06-04 08:01 – Updated: 2025-06-17 11:46
VLAI?
Summary
This vulnerability allows the successful attacker to gain unauthorized access to a configuration web page delivered by the integrated web Server of EIBPORT. This issue affects EIBPORT V3 KNX: through 3.9.8; EIBPORT V3 KNX GSM: through 3.9.8.
CWE
Assigner
ABB
Impacted products
Vendor Product Version
ABB EIBPORT V3 KNX Affected: 0 , ≤ 3.9.8 (custom)
Create a notification for this product.
    ABB EIBPORT V3 KNX GSM Affected: 0 , ≤ 3.9.8 (custom)
Create a notification for this product.
Credits
Psytester for describing the findings and helping to verify the resolving implementation Frank van den Hurk for working with us to help protect customers
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-13967",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-04T13:28:21.636579Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-04T13:28:36.576Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EIBPORT V3 KNX",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.9.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EIBPORT V3  KNX GSM",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.9.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Psytester for describing the findings and helping to verify the resolving implementation"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Frank van den Hurk for working with us to help protect customers"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "This vulnerability allows the successful attacker to gain unauthorized access to a \nconfiguration web page delivered by the integrated web Server of EIBPORT.\n\n\u003cp\u003eThis issue affects EIBPORT V3 KNX: through 3.9.8; EIBPORT V3 KNX GSM: through 3.9.8.\u003c/p\u003e"
            }
          ],
          "value": "This vulnerability allows the successful attacker to gain unauthorized access to a \nconfiguration web page delivered by the integrated web Server of EIBPORT.\n\nThis issue affects EIBPORT V3 KNX: through 3.9.8; EIBPORT V3 KNX GSM: through 3.9.8."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-384",
              "description": "CWE-384 Session Fixation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-17T11:46:53.508Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A1621\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ession-Management Failure",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2024-13967",
    "datePublished": "2025-06-04T08:01:43.117Z",
    "dateReserved": "2025-06-04T07:03:43.612Z",
    "dateUpdated": "2025-06-17T11:46:53.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}