Search criteria
40 vulnerabilities found for EKI-6333AC-2G by Advantech
CVE-2024-50377 (GCVE-0-2024-50377)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:57 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-798 "Use of Hard-coded Credentials" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password.
Severity ?
6.5 (Medium)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50377",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:06:13.498542Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:25.481Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-798 \"Use of Hard-coded Credentials\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password."
}
],
"value": "A CWE-798 \"Use of Hard-coded Credentials\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:27:34.173Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50377"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50377",
"datePublished": "2024-11-26T10:57:27.054Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:25.481Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50376 (GCVE-0-2024-50376)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:57 – Updated: 2024-11-26 14:09
VLAI?
Summary
A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID.
Severity ?
7.3 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50376",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:01:58.748636Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:09:22.624Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-79 \"Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID."
}
],
"value": "A CWE-79 \"Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:27:26.192Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50376"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50376",
"datePublished": "2024-11-26T10:57:14.296Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:09:22.624Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50375 (GCVE-0-2024-50375)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:57 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50375",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:10:48.241907Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:25.629Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-306 \"Missing Authentication for Critical Function\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point."
}
],
"value": "A CWE-306 \"Missing Authentication for Critical Function\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:27:19.023Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50375"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50375",
"datePublished": "2024-11-26T10:57:03.468Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:25.629Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50374 (GCVE-0-2024-50374)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:56 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50374",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:10:55.509356Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:25.792Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"capture_packages\" operation."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"capture_packages\" operation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:27:11.826Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50374"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50374",
"datePublished": "2024-11-26T10:56:28.680Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:25.792Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50373 (GCVE-0-2024-50373)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:56 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50373",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:04.352815Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:25.933Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"restore_config_from_utility\" operation."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"restore_config_from_utility\" operation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:27:04.024Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50373"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50373",
"datePublished": "2024-11-26T10:56:18.987Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:25.933Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50372 (GCVE-0-2024-50372)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:56 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50372",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:11.452183Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:26.080Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"backup_config_to_utility\" operation."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"backup_config_to_utility\" operation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:55.560Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50372"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50372",
"datePublished": "2024-11-26T10:56:08.644Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:26.080Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50371 (GCVE-0-2024-50371)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:55 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50371",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:19.188383Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:26.231Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"wlan_scan\" operation."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"wlan_scan\" operation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:48.500Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50371"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50371",
"datePublished": "2024-11-26T10:55:58.526Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:26.231Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50370 (GCVE-0-2024-50370)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:55 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50370",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:28.496361Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:26.395Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"cfg_cmd_set_eth_conf\" operation."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"cfg_cmd_set_eth_conf\" operation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:39.677Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50370"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50370",
"datePublished": "2024-11-26T10:55:45.151Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:26.395Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50369 (GCVE-0-2024-50369)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:55 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50369",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:37.403098Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:26.553Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"multiple_ssid_htm\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"multiple_ssid_htm\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:31.178Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50369"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50369",
"datePublished": "2024-11-26T10:55:29.755Z",
"dateReserved": "2024-10-23T07:55:58.310Z",
"dateUpdated": "2024-11-26T14:19:26.553Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50368 (GCVE-0-2024-50368)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:55 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50368",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:44.207206Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:26.687Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"basic_htm\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"basic_htm\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:22.641Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50368"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50368",
"datePublished": "2024-11-26T10:55:16.384Z",
"dateReserved": "2024-10-23T07:55:58.310Z",
"dateUpdated": "2024-11-26T14:19:26.687Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50367 (GCVE-0-2024-50367)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:55 – Updated: 2024-11-26 15:37
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "sta_log_htm" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50367",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T15:37:05.528245Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T15:37:10.967Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"sta_log_htm\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"sta_log_htm\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:11.882Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50367"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50367",
"datePublished": "2024-11-26T10:55:06.118Z",
"dateReserved": "2024-10-23T07:55:56.656Z",
"dateUpdated": "2024-11-26T15:37:10.967Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50366 (GCVE-0-2024-50366)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:54 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "applications_apply" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50366",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:50.487229Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:26.822Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"applications_apply\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"applications_apply\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:01.513Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50366"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50366",
"datePublished": "2024-11-26T10:54:55.541Z",
"dateReserved": "2024-10-23T07:55:56.656Z",
"dateUpdated": "2024-11-26T14:19:26.822Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50365 (GCVE-0-2024-50365)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:54 – Updated: 2024-11-26 14:46
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "lan_apply" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50365",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:46:14.274310Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:46:21.281Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"lan_apply\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"lan_apply\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:25:51.031Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50365"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50365",
"datePublished": "2024-11-26T10:54:43.728Z",
"dateReserved": "2024-10-23T07:55:56.655Z",
"dateUpdated": "2024-11-26T14:46:21.281Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50364 (GCVE-0-2024-50364)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:54 – Updated: 2024-11-26 14:46
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "export_log" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50364",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:46:28.644094Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:46:34.267Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"export_log\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"export_log\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:25:40.520Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50364"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50364",
"datePublished": "2024-11-26T10:54:32.798Z",
"dateReserved": "2024-10-23T07:55:56.655Z",
"dateUpdated": "2024-11-26T14:46:34.267Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50363 (GCVE-0-2024-50363)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:54 – Updated: 2024-11-26 14:46
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "mp_apply" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50363",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:46:54.867164Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:46:59.844Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"mp_apply\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"mp_apply\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:25:31.876Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50363"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50363",
"datePublished": "2024-11-26T10:54:20.523Z",
"dateReserved": "2024-10-23T07:55:56.655Z",
"dateUpdated": "2024-11-26T14:46:59.844Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50377 (GCVE-0-2024-50377)
Vulnerability from nvd – Published: 2024-11-26 10:57 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-798 "Use of Hard-coded Credentials" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password.
Severity ?
6.5 (Medium)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50377",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:06:13.498542Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:25.481Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-798 \"Use of Hard-coded Credentials\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password."
}
],
"value": "A CWE-798 \"Use of Hard-coded Credentials\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:27:34.173Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50377"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50377",
"datePublished": "2024-11-26T10:57:27.054Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:25.481Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50376 (GCVE-0-2024-50376)
Vulnerability from nvd – Published: 2024-11-26 10:57 – Updated: 2024-11-26 14:09
VLAI?
Summary
A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID.
Severity ?
7.3 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50376",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:01:58.748636Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:09:22.624Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-79 \"Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID."
}
],
"value": "A CWE-79 \"Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:27:26.192Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50376"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50376",
"datePublished": "2024-11-26T10:57:14.296Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:09:22.624Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50375 (GCVE-0-2024-50375)
Vulnerability from nvd – Published: 2024-11-26 10:57 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50375",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:10:48.241907Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:25.629Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-306 \"Missing Authentication for Critical Function\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point."
}
],
"value": "A CWE-306 \"Missing Authentication for Critical Function\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:27:19.023Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50375"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50375",
"datePublished": "2024-11-26T10:57:03.468Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:25.629Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50374 (GCVE-0-2024-50374)
Vulnerability from nvd – Published: 2024-11-26 10:56 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50374",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:10:55.509356Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:25.792Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"capture_packages\" operation."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"capture_packages\" operation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:27:11.826Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50374"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50374",
"datePublished": "2024-11-26T10:56:28.680Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:25.792Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50373 (GCVE-0-2024-50373)
Vulnerability from nvd – Published: 2024-11-26 10:56 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50373",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:04.352815Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:25.933Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"restore_config_from_utility\" operation."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"restore_config_from_utility\" operation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:27:04.024Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50373"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50373",
"datePublished": "2024-11-26T10:56:18.987Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:25.933Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50372 (GCVE-0-2024-50372)
Vulnerability from nvd – Published: 2024-11-26 10:56 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50372",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:11.452183Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:26.080Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"backup_config_to_utility\" operation."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"backup_config_to_utility\" operation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:55.560Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50372"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50372",
"datePublished": "2024-11-26T10:56:08.644Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:26.080Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50371 (GCVE-0-2024-50371)
Vulnerability from nvd – Published: 2024-11-26 10:55 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50371",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:19.188383Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:26.231Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"wlan_scan\" operation."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"wlan_scan\" operation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:48.500Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50371"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50371",
"datePublished": "2024-11-26T10:55:58.526Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:26.231Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50370 (GCVE-0-2024-50370)
Vulnerability from nvd – Published: 2024-11-26 10:55 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50370",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:28.496361Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:26.395Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"cfg_cmd_set_eth_conf\" operation."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"cfg_cmd_set_eth_conf\" operation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:39.677Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50370"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50370",
"datePublished": "2024-11-26T10:55:45.151Z",
"dateReserved": "2024-10-23T07:55:58.311Z",
"dateUpdated": "2024-11-26T14:19:26.395Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50369 (GCVE-0-2024-50369)
Vulnerability from nvd – Published: 2024-11-26 10:55 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50369",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:37.403098Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:26.553Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"multiple_ssid_htm\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"multiple_ssid_htm\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:31.178Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50369"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50369",
"datePublished": "2024-11-26T10:55:29.755Z",
"dateReserved": "2024-10-23T07:55:58.310Z",
"dateUpdated": "2024-11-26T14:19:26.553Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50368 (GCVE-0-2024-50368)
Vulnerability from nvd – Published: 2024-11-26 10:55 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50368",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:44.207206Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:26.687Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"basic_htm\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"basic_htm\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:22.641Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50368"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50368",
"datePublished": "2024-11-26T10:55:16.384Z",
"dateReserved": "2024-10-23T07:55:58.310Z",
"dateUpdated": "2024-11-26T14:19:26.687Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50367 (GCVE-0-2024-50367)
Vulnerability from nvd – Published: 2024-11-26 10:55 – Updated: 2024-11-26 15:37
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "sta_log_htm" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50367",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T15:37:05.528245Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T15:37:10.967Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"sta_log_htm\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"sta_log_htm\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:11.882Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50367"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50367",
"datePublished": "2024-11-26T10:55:06.118Z",
"dateReserved": "2024-10-23T07:55:56.656Z",
"dateUpdated": "2024-11-26T15:37:10.967Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50366 (GCVE-0-2024-50366)
Vulnerability from nvd – Published: 2024-11-26 10:54 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "applications_apply" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50366",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:11:50.487229Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:26.822Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"applications_apply\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"applications_apply\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:26:01.513Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50366"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50366",
"datePublished": "2024-11-26T10:54:55.541Z",
"dateReserved": "2024-10-23T07:55:56.656Z",
"dateUpdated": "2024-11-26T14:19:26.822Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50365 (GCVE-0-2024-50365)
Vulnerability from nvd – Published: 2024-11-26 10:54 – Updated: 2024-11-26 14:46
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "lan_apply" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50365",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:46:14.274310Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:46:21.281Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"lan_apply\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"lan_apply\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:25:51.031Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50365"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50365",
"datePublished": "2024-11-26T10:54:43.728Z",
"dateReserved": "2024-10-23T07:55:56.655Z",
"dateUpdated": "2024-11-26T14:46:21.281Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50364 (GCVE-0-2024-50364)
Vulnerability from nvd – Published: 2024-11-26 10:54 – Updated: 2024-11-26 14:46
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "export_log" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50364",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:46:28.644094Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:46:34.267Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"export_log\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"export_log\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:25:40.520Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50364"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50364",
"datePublished": "2024-11-26T10:54:32.798Z",
"dateReserved": "2024-10-23T07:55:56.655Z",
"dateUpdated": "2024-11-26T14:46:34.267Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50363 (GCVE-0-2024-50363)
Vulnerability from nvd – Published: 2024-11-26 10:54 – Updated: 2024-11-26 14:46
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "mp_apply" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50363",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:46:54.867164Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:46:59.844Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"mp_apply\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"mp_apply\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:25:31.876Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50363"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50363",
"datePublished": "2024-11-26T10:54:20.523Z",
"dateReserved": "2024-10-23T07:55:56.655Z",
"dateUpdated": "2024-11-26T14:46:59.844Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}