CVE-2023-46144 (GCVE-0-2023-46144)
Vulnerability from cvelistv5 – Published: 2023-12-14 14:08 – Updated: 2024-10-01 06:18
VLAI?
Title
PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check
Summary
A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices.
Severity ?
6.5 (Medium)
CWE
- CWE-494 - Download of Code Without Integrity Check
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , ≤ 2024.0
(semver)
|
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
Credits
Reid Wightman of Dragos, Inc.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.934Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1502",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PLCnext Engineer",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
}
],
"value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494: Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-01T06:18:18.730Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"source": {
"advisory": "VDE-2023-058",
"defect": [
"CERT@VDE#64611"
],
"discovery": "EXTERNAL"
},
"title": "PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46144",
"datePublished": "2023-12-14T14:08:07.244Z",
"dateReserved": "2023-10-17T07:04:03.577Z",
"dateUpdated": "2024-10-01T06:18:18.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46142 (GCVE-0-2023-46142)
Vulnerability from cvelistv5 – Published: 2023-12-14 14:05 – Updated: 2024-08-02 20:37
VLAI?
Title
PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control
Summary
A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.
Severity ?
8.8 (High)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , ≤ 2024.0
(semver)
|
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
Credits
Reid Wightman of Dragos, Inc.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.840Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1502",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PLCnext Engineer",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
}
],
"value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T14:05:35.741Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"source": {
"advisory": "VDE-2023-056",
"defect": [
"CERT@VDE#64609"
],
"discovery": "EXTERNAL"
},
"title": "PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46142",
"datePublished": "2023-12-14T14:05:35.741Z",
"dateReserved": "2023-10-17T07:04:03.576Z",
"dateUpdated": "2024-08-02T20:37:39.840Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46144 (GCVE-0-2023-46144)
Vulnerability from nvd – Published: 2023-12-14 14:08 – Updated: 2024-10-01 06:18
VLAI?
Title
PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check
Summary
A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices.
Severity ?
6.5 (Medium)
CWE
- CWE-494 - Download of Code Without Integrity Check
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , ≤ 2024.0
(semver)
|
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
Credits
Reid Wightman of Dragos, Inc.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.934Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1502",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PLCnext Engineer",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
}
],
"value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494: Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-01T06:18:18.730Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"source": {
"advisory": "VDE-2023-058",
"defect": [
"CERT@VDE#64611"
],
"discovery": "EXTERNAL"
},
"title": "PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46144",
"datePublished": "2023-12-14T14:08:07.244Z",
"dateReserved": "2023-10-17T07:04:03.577Z",
"dateUpdated": "2024-10-01T06:18:18.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46142 (GCVE-0-2023-46142)
Vulnerability from nvd – Published: 2023-12-14 14:05 – Updated: 2024-08-02 20:37
VLAI?
Title
PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control
Summary
A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.
Severity ?
8.8 (High)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , ≤ 2024.0
(semver)
|
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
Credits
Reid Wightman of Dragos, Inc.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.840Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1502",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PLCnext Engineer",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
}
],
"value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T14:05:35.741Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"source": {
"advisory": "VDE-2023-056",
"defect": [
"CERT@VDE#64609"
],
"discovery": "EXTERNAL"
},
"title": "PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46142",
"datePublished": "2023-12-14T14:05:35.741Z",
"dateReserved": "2023-10-17T07:04:03.576Z",
"dateUpdated": "2024-08-02T20:37:39.840Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}