Search criteria
28 vulnerabilities found for EX1800T by TOTOLINK
CVE-2025-2370 (GCVE-0-2025-2370)
Vulnerability from cvelistv5 – Published: 2025-03-17 09:00 – Updated: 2025-03-17 16:08| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2370",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-17T16:07:52.831698Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T16:08:06.591Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "selph (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in TOTOLINK EX1800T up to 9.1.0cu.2112_B20220316. It has been declared as critical. Affected by this vulnerability is the function setWiFiExtenderConfig of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument apcliSsid leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In TOTOLINK EX1800T bis 9.1.0cu.2112_B20220316 wurde eine kritische Schwachstelle ausgemacht. Hierbei betrifft es die Funktion setWiFiExtenderConfig der Datei /cgi-bin/cstecgi.cgi. Durch das Beeinflussen des Arguments apcliSsid mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T09:00:09.912Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-299869 | TOTOLINK EX1800T cstecgi.cgi setWiFiExtenderConfig stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.299869"
},
{
"name": "VDB-299869 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.299869"
},
{
"name": "Submit #515329 | Totolink EX1800T V9.1.0cu.2112_B20220316 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.515329"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/Stack-based%20Buffer%20Overflow%2003%20setWiFiExtenderConfig-_apcliSsid.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-16T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-16T13:57:26.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi setWiFiExtenderConfig stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2370",
"datePublished": "2025-03-17T09:00:09.912Z",
"dateReserved": "2025-03-16T12:52:07.942Z",
"dateUpdated": "2025-03-17T16:08:06.591Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2369 (GCVE-0-2025-2369)
Vulnerability from cvelistv5 – Published: 2025-03-17 08:31 – Updated: 2025-03-17 16:22| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2369",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-17T16:22:14.210008Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T16:22:33.739Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "selph (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in TOTOLINK EX1800T up to 9.1.0cu.2112_B20220316. It has been classified as critical. Affected is the function setPasswordCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument admpass leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in TOTOLINK EX1800T bis 9.1.0cu.2112_B20220316 ausgemacht. Dabei betrifft es die Funktion setPasswordCfg der Datei /cgi-bin/cstecgi.cgi. Durch Manipulieren des Arguments admpass mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T08:31:07.147Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-299868 | TOTOLINK EX1800T cstecgi.cgi setPasswordCfg stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.299868"
},
{
"name": "VDB-299868 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.299868"
},
{
"name": "Submit #515328 | Totolink EX1800T V9.1.0cu.2112_B20220316 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.515328"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/Stack-based%20Buffer%20Overflow%2002%20setPasswordCfg-_admpass.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-16T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-16T13:57:20.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi setPasswordCfg stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2369",
"datePublished": "2025-03-17T08:31:07.147Z",
"dateReserved": "2025-03-16T12:52:05.519Z",
"dateUpdated": "2025-03-17T16:22:33.739Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2097 (GCVE-0-2025-2097)
Vulnerability from cvelistv5 – Published: 2025-03-07 22:31 – Updated: 2025-03-10 17:20| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2097",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-10T17:20:16.526876Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-10T17:20:32.188Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/Stack-based%20Buffer%20Overflow%2001%20setRptWizardCfg-_loginpass.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "selph (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. This issue affects the function setRptWizardCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument loginpass leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in TOTOLINK EX1800T 9.1.0cu.2112_B20220316 entdeckt. Sie wurde als kritisch eingestuft. Davon betroffen ist die Funktion setRptWizardCfg der Datei /cgi-bin/cstecgi.cgi. Durch Manipulieren des Arguments loginpass mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T22:31:06.074Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-298955 | TOTOLINK EX1800T cstecgi.cgi setRptWizardCfg stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.298955"
},
{
"name": "VDB-298955 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.298955"
},
{
"name": "Submit #515326 | Totolink EX1800T V9.1.0cu.2112_B20220316 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.515326"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/Stack-based%20Buffer%20Overflow%2001%20setRptWizardCfg-_loginpass.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-07T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-07T16:50:18.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi setRptWizardCfg stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2097",
"datePublished": "2025-03-07T22:31:06.074Z",
"dateReserved": "2025-03-07T15:45:15.110Z",
"dateUpdated": "2025-03-10T17:20:32.188Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2096 (GCVE-0-2025-2096)
Vulnerability from cvelistv5 – Published: 2025-03-07 22:00 – Updated: 2025-03-07 22:28| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2096",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-07T22:28:32.308262Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T22:28:45.665Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/OS%20Command%20Injection%2004%20setRebootScheCfg-_mode.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "selph (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. This vulnerability affects the function setRebootScheCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument mode/week/minute/recHour leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In TOTOLINK EX1800T 9.1.0cu.2112_B20220316 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Hierbei betrifft es die Funktion setRebootScheCfg der Datei /cgi-bin/cstecgi.cgi. Durch das Manipulieren des Arguments mode/week/minute/recHour mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T22:00:16.475Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-298954 | TOTOLINK EX1800T cstecgi.cgi setRebootScheCfg os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.298954"
},
{
"name": "VDB-298954 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.298954"
},
{
"name": "Submit #515322 | Totolink EX1800T V9.1.0cu.2112_B20220316 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.515322"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/OS%20Command%20Injection%2004%20setRebootScheCfg-_mode.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-07T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-07T16:50:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi setRebootScheCfg os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2096",
"datePublished": "2025-03-07T22:00:16.475Z",
"dateReserved": "2025-03-07T15:44:58.716Z",
"dateUpdated": "2025-03-07T22:28:45.665Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2095 (GCVE-0-2025-2095)
Vulnerability from cvelistv5 – Published: 2025-03-07 22:00 – Updated: 2025-03-07 22:28| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2095",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-07T22:27:59.117562Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T22:28:13.640Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/OS%20Command%20Injection%2003%20setDmzCfg-_ip.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "selph (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. This affects the function setDmzCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ip leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in TOTOLINK EX1800T 9.1.0cu.2112_B20220316 entdeckt. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion setDmzCfg der Datei /cgi-bin/cstecgi.cgi. Mittels Manipulieren des Arguments ip mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T22:00:12.940Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-298953 | TOTOLINK EX1800T cstecgi.cgi setDmzCfg os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.298953"
},
{
"name": "VDB-298953 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.298953"
},
{
"name": "Submit #515321 | Totolink EX1800T V9.1.0cu.2112_B20220316 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.515321"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/OS%20Command%20Injection%2003%20setDmzCfg-_ip.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-07T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-07T16:49:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi setDmzCfg os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2095",
"datePublished": "2025-03-07T22:00:12.940Z",
"dateReserved": "2025-03-07T15:44:50.692Z",
"dateUpdated": "2025-03-07T22:28:13.640Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2094 (GCVE-0-2025-2094)
Vulnerability from cvelistv5 – Published: 2025-03-07 21:31 – Updated: 2025-03-07 22:27| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2094",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-07T22:27:19.607418Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T22:27:35.683Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/OS%20Command%20Injection%2001%20setWiFiExtenderConfig-_apcliKey.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "selph (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. It has been rated as critical. Affected by this issue is the function setWiFiExtenderConfig of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument apcliKey/key leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in TOTOLINK EX1800T 9.1.0cu.2112_B20220316 ausgemacht. Dies betrifft die Funktion setWiFiExtenderConfig der Datei /cgi-bin/cstecgi.cgi. Mittels dem Manipulieren des Arguments apcliKey/key mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T21:31:09.611Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-298952 | TOTOLINK EX1800T cstecgi.cgi setWiFiExtenderConfig os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.298952"
},
{
"name": "VDB-298952 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.298952"
},
{
"name": "Submit #515319 | Totolink EX1800T V9.1.0cu.2112_B20220316 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.515319"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/OS%20Command%20Injection%2001%20setWiFiExtenderConfig-_apcliKey.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-07T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-07T16:49:40.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi setWiFiExtenderConfig os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2094",
"datePublished": "2025-03-07T21:31:09.611Z",
"dateReserved": "2025-03-07T15:44:35.129Z",
"dateUpdated": "2025-03-07T22:27:35.683Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-1852 (GCVE-0-2025-1852)
Vulnerability from cvelistv5 – Published: 2025-03-03 05:31 – Updated: 2025-03-03 17:19| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1852",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-03T17:18:59.736991Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-03T17:19:05.041Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/watermelon-happy/cve/blob/main/ex1800tCVE.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "Totolink",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "watermelon-happy (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Totolink EX1800T 9.1.0cu.2112_B20220316 and classified as critical. This vulnerability affects the function loginAuth of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument password leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Totolink EX1800T 9.1.0cu.2112_B20220316 wurde eine kritische Schwachstelle gefunden. Es geht um die Funktion loginAuth der Datei /cgi-bin/cstecgi.cgi. Durch das Beeinflussen des Arguments password mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-03T05:31:06.795Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-298120 | Totolink EX1800T cstecgi.cgi loginAuth buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.298120"
},
{
"name": "VDB-298120 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.298120"
},
{
"name": "Submit #505362 | totolink EX1800T V9.1.0cu.2112_B20220316 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.505362"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/watermelon-happy/cve/blob/main/ex1800tCVE.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-02T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-02T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-02T21:13:06.000Z",
"value": "VulDB entry last update"
}
],
"title": "Totolink EX1800T cstecgi.cgi loginAuth buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-1852",
"datePublished": "2025-03-03T05:31:06.795Z",
"dateReserved": "2025-03-02T20:08:03.083Z",
"dateUpdated": "2025-03-03T17:19:05.041Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-12352 (GCVE-0-2024-12352)
Vulnerability from cvelistv5 – Published: 2024-12-09 01:00 – Updated: 2024-12-09 20:19| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ex1800t",
"vendor": "totolink",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-12352",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-09T20:18:56.909258Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-09T20:19:48.365Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "zhangzheng (VulDB User)"
},
{
"lang": "en",
"type": "analyst",
"value": "zhangzheng (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as problematic was found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. This vulnerability affects the function sub_40662C of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In TOTOLINK EX1800T 9.1.0cu.2112_B20220316 wurde eine Schwachstelle entdeckt. Sie wurde als problematisch eingestuft. Betroffen ist die Funktion sub_40662C der Datei /cgi-bin/cstecgi.cgi. Durch das Manipulieren des Arguments ssid mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 4,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-09T06:22:31.784Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-287272 | TOTOLINK EX1800T cstecgi.cgi sub_40662C stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.287272"
},
{
"name": "VDB-287272 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.287272"
},
{
"name": "Submit #457392 | Totolink ex1800t V9.1.0cu.2112_B20220316 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.457392"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/zheng0064/cve/blob/main/StackOverFlow-CVE.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-12-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-12-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-12-09T07:27:11.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi sub_40662C stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-12352",
"datePublished": "2024-12-09T01:00:16.961Z",
"dateReserved": "2024-12-08T17:01:34.733Z",
"dateUpdated": "2024-12-09T20:19:48.365Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2370 (GCVE-0-2025-2370)
Vulnerability from nvd – Published: 2025-03-17 09:00 – Updated: 2025-03-17 16:08| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2370",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-17T16:07:52.831698Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T16:08:06.591Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "selph (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in TOTOLINK EX1800T up to 9.1.0cu.2112_B20220316. It has been declared as critical. Affected by this vulnerability is the function setWiFiExtenderConfig of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument apcliSsid leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In TOTOLINK EX1800T bis 9.1.0cu.2112_B20220316 wurde eine kritische Schwachstelle ausgemacht. Hierbei betrifft es die Funktion setWiFiExtenderConfig der Datei /cgi-bin/cstecgi.cgi. Durch das Beeinflussen des Arguments apcliSsid mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T09:00:09.912Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-299869 | TOTOLINK EX1800T cstecgi.cgi setWiFiExtenderConfig stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.299869"
},
{
"name": "VDB-299869 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.299869"
},
{
"name": "Submit #515329 | Totolink EX1800T V9.1.0cu.2112_B20220316 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.515329"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/Stack-based%20Buffer%20Overflow%2003%20setWiFiExtenderConfig-_apcliSsid.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-16T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-16T13:57:26.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi setWiFiExtenderConfig stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2370",
"datePublished": "2025-03-17T09:00:09.912Z",
"dateReserved": "2025-03-16T12:52:07.942Z",
"dateUpdated": "2025-03-17T16:08:06.591Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2369 (GCVE-0-2025-2369)
Vulnerability from nvd – Published: 2025-03-17 08:31 – Updated: 2025-03-17 16:22| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2369",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-17T16:22:14.210008Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T16:22:33.739Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "selph (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in TOTOLINK EX1800T up to 9.1.0cu.2112_B20220316. It has been classified as critical. Affected is the function setPasswordCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument admpass leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in TOTOLINK EX1800T bis 9.1.0cu.2112_B20220316 ausgemacht. Dabei betrifft es die Funktion setPasswordCfg der Datei /cgi-bin/cstecgi.cgi. Durch Manipulieren des Arguments admpass mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T08:31:07.147Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-299868 | TOTOLINK EX1800T cstecgi.cgi setPasswordCfg stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.299868"
},
{
"name": "VDB-299868 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.299868"
},
{
"name": "Submit #515328 | Totolink EX1800T V9.1.0cu.2112_B20220316 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.515328"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/Stack-based%20Buffer%20Overflow%2002%20setPasswordCfg-_admpass.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-16T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-16T13:57:20.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi setPasswordCfg stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2369",
"datePublished": "2025-03-17T08:31:07.147Z",
"dateReserved": "2025-03-16T12:52:05.519Z",
"dateUpdated": "2025-03-17T16:22:33.739Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2097 (GCVE-0-2025-2097)
Vulnerability from nvd – Published: 2025-03-07 22:31 – Updated: 2025-03-10 17:20| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2097",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-10T17:20:16.526876Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-10T17:20:32.188Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/Stack-based%20Buffer%20Overflow%2001%20setRptWizardCfg-_loginpass.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "selph (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. This issue affects the function setRptWizardCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument loginpass leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in TOTOLINK EX1800T 9.1.0cu.2112_B20220316 entdeckt. Sie wurde als kritisch eingestuft. Davon betroffen ist die Funktion setRptWizardCfg der Datei /cgi-bin/cstecgi.cgi. Durch Manipulieren des Arguments loginpass mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T22:31:06.074Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-298955 | TOTOLINK EX1800T cstecgi.cgi setRptWizardCfg stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.298955"
},
{
"name": "VDB-298955 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.298955"
},
{
"name": "Submit #515326 | Totolink EX1800T V9.1.0cu.2112_B20220316 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.515326"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/Stack-based%20Buffer%20Overflow%2001%20setRptWizardCfg-_loginpass.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-07T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-07T16:50:18.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi setRptWizardCfg stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2097",
"datePublished": "2025-03-07T22:31:06.074Z",
"dateReserved": "2025-03-07T15:45:15.110Z",
"dateUpdated": "2025-03-10T17:20:32.188Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2096 (GCVE-0-2025-2096)
Vulnerability from nvd – Published: 2025-03-07 22:00 – Updated: 2025-03-07 22:28| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2096",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-07T22:28:32.308262Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T22:28:45.665Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/OS%20Command%20Injection%2004%20setRebootScheCfg-_mode.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "selph (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. This vulnerability affects the function setRebootScheCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument mode/week/minute/recHour leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In TOTOLINK EX1800T 9.1.0cu.2112_B20220316 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Hierbei betrifft es die Funktion setRebootScheCfg der Datei /cgi-bin/cstecgi.cgi. Durch das Manipulieren des Arguments mode/week/minute/recHour mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T22:00:16.475Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-298954 | TOTOLINK EX1800T cstecgi.cgi setRebootScheCfg os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.298954"
},
{
"name": "VDB-298954 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.298954"
},
{
"name": "Submit #515322 | Totolink EX1800T V9.1.0cu.2112_B20220316 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.515322"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/OS%20Command%20Injection%2004%20setRebootScheCfg-_mode.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-07T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-07T16:50:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi setRebootScheCfg os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2096",
"datePublished": "2025-03-07T22:00:16.475Z",
"dateReserved": "2025-03-07T15:44:58.716Z",
"dateUpdated": "2025-03-07T22:28:45.665Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2095 (GCVE-0-2025-2095)
Vulnerability from nvd – Published: 2025-03-07 22:00 – Updated: 2025-03-07 22:28| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2095",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-07T22:27:59.117562Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T22:28:13.640Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/OS%20Command%20Injection%2003%20setDmzCfg-_ip.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "selph (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. This affects the function setDmzCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ip leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in TOTOLINK EX1800T 9.1.0cu.2112_B20220316 entdeckt. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion setDmzCfg der Datei /cgi-bin/cstecgi.cgi. Mittels Manipulieren des Arguments ip mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T22:00:12.940Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-298953 | TOTOLINK EX1800T cstecgi.cgi setDmzCfg os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.298953"
},
{
"name": "VDB-298953 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.298953"
},
{
"name": "Submit #515321 | Totolink EX1800T V9.1.0cu.2112_B20220316 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.515321"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/OS%20Command%20Injection%2003%20setDmzCfg-_ip.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-07T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-07T16:49:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi setDmzCfg os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2095",
"datePublished": "2025-03-07T22:00:12.940Z",
"dateReserved": "2025-03-07T15:44:50.692Z",
"dateUpdated": "2025-03-07T22:28:13.640Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2094 (GCVE-0-2025-2094)
Vulnerability from nvd – Published: 2025-03-07 21:31 – Updated: 2025-03-07 22:27| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2094",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-07T22:27:19.607418Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T22:27:35.683Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/OS%20Command%20Injection%2001%20setWiFiExtenderConfig-_apcliKey.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "selph (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. It has been rated as critical. Affected by this issue is the function setWiFiExtenderConfig of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument apcliKey/key leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in TOTOLINK EX1800T 9.1.0cu.2112_B20220316 ausgemacht. Dies betrifft die Funktion setWiFiExtenderConfig der Datei /cgi-bin/cstecgi.cgi. Mittels dem Manipulieren des Arguments apcliKey/key mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-07T21:31:09.611Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-298952 | TOTOLINK EX1800T cstecgi.cgi setWiFiExtenderConfig os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.298952"
},
{
"name": "VDB-298952 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.298952"
},
{
"name": "Submit #515319 | Totolink EX1800T V9.1.0cu.2112_B20220316 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.515319"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/kn0sky/cve/blob/main/TOTOLINK%20EX1800T/OS%20Command%20Injection%2001%20setWiFiExtenderConfig-_apcliKey.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-07T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-07T16:49:40.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi setWiFiExtenderConfig os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2094",
"datePublished": "2025-03-07T21:31:09.611Z",
"dateReserved": "2025-03-07T15:44:35.129Z",
"dateUpdated": "2025-03-07T22:27:35.683Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-1852 (GCVE-0-2025-1852)
Vulnerability from nvd – Published: 2025-03-03 05:31 – Updated: 2025-03-03 17:19| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1852",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-03T17:18:59.736991Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-03T17:19:05.041Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/watermelon-happy/cve/blob/main/ex1800tCVE.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "Totolink",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "watermelon-happy (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Totolink EX1800T 9.1.0cu.2112_B20220316 and classified as critical. This vulnerability affects the function loginAuth of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument password leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Totolink EX1800T 9.1.0cu.2112_B20220316 wurde eine kritische Schwachstelle gefunden. Es geht um die Funktion loginAuth der Datei /cgi-bin/cstecgi.cgi. Durch das Beeinflussen des Arguments password mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-03T05:31:06.795Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-298120 | Totolink EX1800T cstecgi.cgi loginAuth buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.298120"
},
{
"name": "VDB-298120 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.298120"
},
{
"name": "Submit #505362 | totolink EX1800T V9.1.0cu.2112_B20220316 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.505362"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/watermelon-happy/cve/blob/main/ex1800tCVE.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-02T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-02T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-02T21:13:06.000Z",
"value": "VulDB entry last update"
}
],
"title": "Totolink EX1800T cstecgi.cgi loginAuth buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-1852",
"datePublished": "2025-03-03T05:31:06.795Z",
"dateReserved": "2025-03-02T20:08:03.083Z",
"dateUpdated": "2025-03-03T17:19:05.041Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-12352 (GCVE-0-2024-12352)
Vulnerability from nvd – Published: 2024-12-09 01:00 – Updated: 2024-12-09 20:19| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ex1800t",
"vendor": "totolink",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-12352",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-09T20:18:56.909258Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-09T20:19:48.365Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX1800T",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "9.1.0cu.2112_B20220316"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "zhangzheng (VulDB User)"
},
{
"lang": "en",
"type": "analyst",
"value": "zhangzheng (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as problematic was found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. This vulnerability affects the function sub_40662C of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In TOTOLINK EX1800T 9.1.0cu.2112_B20220316 wurde eine Schwachstelle entdeckt. Sie wurde als problematisch eingestuft. Betroffen ist die Funktion sub_40662C der Datei /cgi-bin/cstecgi.cgi. Durch das Manipulieren des Arguments ssid mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 4,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-09T06:22:31.784Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-287272 | TOTOLINK EX1800T cstecgi.cgi sub_40662C stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.287272"
},
{
"name": "VDB-287272 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.287272"
},
{
"name": "Submit #457392 | Totolink ex1800t V9.1.0cu.2112_B20220316 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.457392"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/zheng0064/cve/blob/main/StackOverFlow-CVE.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-12-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-12-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-12-09T07:27:11.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX1800T cstecgi.cgi sub_40662C stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-12352",
"datePublished": "2024-12-09T01:00:16.961Z",
"dateReserved": "2024-12-08T17:01:34.733Z",
"dateUpdated": "2024-12-09T20:19:48.365Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
VAR-202312-1262
Vulnerability from variot - Updated: 2024-05-12 23:08TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the ‘langType’ parameter of the setLanguageCfg interface of the cstecgi .cgi. TOTOLINK of ex1800t There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China's TOTOLINK Electronics. An attacker can exploit this vulnerability to execute arbitrary commands on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-1262",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ex1800t",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0cu.2112_b20220316"
},
{
"model": "ex1800t",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex1800t",
"scope": null,
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex1800t",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": "ex1800t firmware 9.1.0cu.2112 b20220316"
},
{
"model": "ex1800t v9.1.0cu.2112 b20220316",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21655"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023770"
},
{
"db": "NVD",
"id": "CVE-2023-51020"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:totolink:ex1800t_firmware:9.1.0cu.2112_b20220316:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51020"
}
]
},
"cve": "CVE-2023-51020",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-21655",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-51020",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-51020",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-21655",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21655"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023770"
},
{
"db": "NVD",
"id": "CVE-2023-51020"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the \u2018langType\u2019 parameter of the setLanguageCfg interface of the cstecgi .cgi. TOTOLINK of ex1800t There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China\u0027s TOTOLINK Electronics. An attacker can exploit this vulnerability to execute arbitrary commands on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51020"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023770"
},
{
"db": "CNVD",
"id": "CNVD-2024-21655"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-51020",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023770",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-21655",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21655"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023770"
},
{
"db": "NVD",
"id": "CVE-2023-51020"
}
]
},
"id": "VAR-202312-1262",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21655"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21655"
}
]
},
"last_update_date": "2024-05-12T23:08:54.835000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023770"
},
{
"db": "NVD",
"id": "CVE-2023-51020"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://815yang.github.io/2023/12/11/ex1800t/2/totolinkex1800t_v9.1.0cu.2112_b20220316setlanguagecfg-langtype/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-51020"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21655"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023770"
},
{
"db": "NVD",
"id": "CVE-2023-51020"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-21655"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023770"
},
{
"db": "NVD",
"id": "CVE-2023-51020"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21655"
},
{
"date": "2024-01-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-023770"
},
{
"date": "2023-12-22T19:15:09.673000",
"db": "NVD",
"id": "CVE-2023-51020"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21655"
},
{
"date": "2024-01-29T07:35:00",
"db": "JVNDB",
"id": "JVNDB-2023-023770"
},
{
"date": "2023-12-27T21:09:01.540000",
"db": "NVD",
"id": "CVE-2023-51020"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK\u00a0 of \u00a0ex1800t\u00a0 Firmware vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023770"
}
],
"trust": 0.8
}
}
VAR-202312-2148
Vulnerability from variot - Updated: 2024-05-12 03:49TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the ‘opmode’ parameter of the setWiFiApConfig interface of the cstecgi .cgi. TOTOLINK of ex1800t There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China's TOTOLINK Electronics. The vulnerability is caused by the opmode parameter of the setWiFiApConfig interface of cstecgi.cgi failing to properly filter special characters and commands in the constructed command. An attacker can exploit this vulnerability to execute arbitrary commands on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-2148",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ex1800t",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0cu.2112_b20220316"
},
{
"model": "ex1800t",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex1800t",
"scope": null,
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex1800t",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": "ex1800t firmware 9.1.0cu.2112 b20220316"
},
{
"model": "ex1800t v9.1.0cu.2112 b20220316",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21660"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023772"
},
{
"db": "NVD",
"id": "CVE-2023-51018"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:totolink:ex1800t_firmware:9.1.0cu.2112_b20220316:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51018"
}
]
},
"cve": "CVE-2023-51018",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-21660",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-51018",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-51018",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-21660",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21660"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023772"
},
{
"db": "NVD",
"id": "CVE-2023-51018"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the \u2018opmode\u2019 parameter of the setWiFiApConfig interface of the cstecgi .cgi. TOTOLINK of ex1800t There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China\u0027s TOTOLINK Electronics. The vulnerability is caused by the opmode parameter of the setWiFiApConfig interface of cstecgi.cgi failing to properly filter special characters and commands in the constructed command. An attacker can exploit this vulnerability to execute arbitrary commands on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51018"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023772"
},
{
"db": "CNVD",
"id": "CNVD-2024-21660"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-51018",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023772",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-21660",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21660"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023772"
},
{
"db": "NVD",
"id": "CVE-2023-51018"
}
]
},
"id": "VAR-202312-2148",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21660"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21660"
}
]
},
"last_update_date": "2024-05-12T03:49:21.253000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023772"
},
{
"db": "NVD",
"id": "CVE-2023-51018"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://815yang.github.io/2023/12/11/ex1800t/2/totolinkex1800t_v9.1.0cu.2112_b2022031setwifiapconfig-opmode/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-51018"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21660"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023772"
},
{
"db": "NVD",
"id": "CVE-2023-51018"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-21660"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023772"
},
{
"db": "NVD",
"id": "CVE-2023-51018"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21660"
},
{
"date": "2024-01-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-023772"
},
{
"date": "2023-12-22T19:15:09.587000",
"db": "NVD",
"id": "CVE-2023-51018"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21660"
},
{
"date": "2024-01-29T07:35:00",
"db": "JVNDB",
"id": "JVNDB-2023-023772"
},
{
"date": "2023-12-27T21:09:49.843000",
"db": "NVD",
"id": "CVE-2023-51018"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK\u00a0 of \u00a0ex1800t\u00a0 Firmware vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023772"
}
],
"trust": 0.8
}
}
VAR-202312-1439
Vulnerability from variot - Updated: 2024-05-12 03:47TOTOlink EX1800T V9.1.0cu.2112_B20220316 is vulnerable to an unauthorized arbitrary command execution in the ‘admuser’ parameter of the setPasswordCfg interface of the cstecgi .cgi. TOTOLINK EX1800T is a Wi-Fi range extender from China's TOTOLINK Electronics. The vulnerability is caused by the admuser parameter of the setPasswordCfg interface of cstecgi.cgi failing to properly filter special characters and commands in the constructed command. An attacker can exploit this vulnerability to execute arbitrary commands on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-1439",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ex1800t",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0cu.2112_b20220316"
},
{
"model": "ex1800t v9.1.0cu.2112 b20220316",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21657"
},
{
"db": "NVD",
"id": "CVE-2023-51025"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:totolink:ex1800t_firmware:9.1.0cu.2112_b20220316:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51025"
}
]
},
"cve": "CVE-2023-51025",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-21657",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-51025",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-21657",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21657"
},
{
"db": "NVD",
"id": "CVE-2023-51025"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOlink EX1800T V9.1.0cu.2112_B20220316 is vulnerable to an unauthorized arbitrary command execution in the \u2018admuser\u2019 parameter of the setPasswordCfg interface of the cstecgi .cgi. TOTOLINK EX1800T is a Wi-Fi range extender from China\u0027s TOTOLINK Electronics. The vulnerability is caused by the admuser parameter of the setPasswordCfg interface of cstecgi.cgi failing to properly filter special characters and commands in the constructed command. An attacker can exploit this vulnerability to execute arbitrary commands on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51025"
},
{
"db": "CNVD",
"id": "CNVD-2024-21657"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-51025",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2024-21657",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21657"
},
{
"db": "NVD",
"id": "CVE-2023-51025"
}
]
},
"id": "VAR-202312-1439",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21657"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21657"
}
]
},
"last_update_date": "2024-05-12T03:47:51.622000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51025"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://815yang.github.io/2023/12/11/ex1800t/2/totolinkex1800t_v9.1.0cu.2112_b20220316setpasswordcfg-admuser/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-51025"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21657"
},
{
"db": "NVD",
"id": "CVE-2023-51025"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-21657"
},
{
"db": "NVD",
"id": "CVE-2023-51025"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21657"
},
{
"date": "2023-12-22T18:15:07.860000",
"db": "NVD",
"id": "CVE-2023-51025"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21657"
},
{
"date": "2023-12-27T21:10:57.747000",
"db": "NVD",
"id": "CVE-2023-51025"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK EX1800T setPasswordCfg interface command execution vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21657"
}
],
"trust": 0.6
}
}
VAR-202312-0767
Vulnerability from variot - Updated: 2024-05-12 03:47TOTOlink EX1800T V9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the ‘hour’ parameter of the setRebootScheCfg interface of the cstecgi .cgi. TOTOLINK EX1800T is a Wi-Fi range extender from China's TOTOLINK Electronics. The vulnerability is caused by the hour parameter of the setRebootScheCfg interface of cstecgi.cgi failing to properly filter special characters and commands in the constructed command. An attacker can exploit this vulnerability to execute arbitrary commands on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-0767",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ex1800t",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0cu.2112_b20220316"
},
{
"model": "ex1800t v9.1.0cu.2112 b20220316",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21658"
},
{
"db": "NVD",
"id": "CVE-2023-51026"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:totolink:ex1800t_firmware:9.1.0cu.2112_b20220316:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51026"
}
]
},
"cve": "CVE-2023-51026",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-21658",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-51026",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-21658",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21658"
},
{
"db": "NVD",
"id": "CVE-2023-51026"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOlink EX1800T V9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the \u2018hour\u2019 parameter of the setRebootScheCfg interface of the cstecgi .cgi. TOTOLINK EX1800T is a Wi-Fi range extender from China\u0027s TOTOLINK Electronics. The vulnerability is caused by the hour parameter of the setRebootScheCfg interface of cstecgi.cgi failing to properly filter special characters and commands in the constructed command. An attacker can exploit this vulnerability to execute arbitrary commands on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51026"
},
{
"db": "CNVD",
"id": "CNVD-2024-21658"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-51026",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2024-21658",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21658"
},
{
"db": "NVD",
"id": "CVE-2023-51026"
}
]
},
"id": "VAR-202312-0767",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21658"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21658"
}
]
},
"last_update_date": "2024-05-12T03:47:51.665000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51026"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://815yang.github.io/2023/12/11/ex1800t/2/totolinkex1800t_v9.1.0cu.2112_b2022031setrebootschecfg-hour/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-51026"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21658"
},
{
"db": "NVD",
"id": "CVE-2023-51026"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-21658"
},
{
"db": "NVD",
"id": "CVE-2023-51026"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21658"
},
{
"date": "2023-12-22T18:15:07.907000",
"db": "NVD",
"id": "CVE-2023-51026"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21658"
},
{
"date": "2023-12-27T21:10:48.950000",
"db": "NVD",
"id": "CVE-2023-51026"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK EX1800T setRebootScheCfg interface command execution vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21658"
}
],
"trust": 0.6
}
}
VAR-202312-2147
Vulnerability from variot - Updated: 2024-05-12 03:46TOTOlink EX1800T V9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the ‘apcliAuthMode’ parameter of the setWiFiExtenderConfig interface of the cstecgi .cgi. TOTOLINK EX1800T is a Wi-Fi range extender from China's TOTOLINK Electronics. The vulnerability is caused by the apcliAuthMode parameter of the setWiFiExtenderConfig interface of cstecgi.cgi failing to properly filter special characters and commands in constructed commands. An attacker can exploit this vulnerability to execute arbitrary commands on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-2147",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ex1800t",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0cu.2112_b20220316"
},
{
"model": "ex1800t v9.1.0cu.2112 b20220316",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21661"
},
{
"db": "NVD",
"id": "CVE-2023-51027"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:totolink:ex1800t_firmware:9.1.0cu.2112_b20220316:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51027"
}
]
},
"cve": "CVE-2023-51027",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-21661",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-51027",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-21661",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21661"
},
{
"db": "NVD",
"id": "CVE-2023-51027"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOlink EX1800T V9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the \u2018apcliAuthMode\u2019 parameter of the setWiFiExtenderConfig interface of the cstecgi .cgi. TOTOLINK EX1800T is a Wi-Fi range extender from China\u0027s TOTOLINK Electronics. The vulnerability is caused by the apcliAuthMode parameter of the setWiFiExtenderConfig interface of cstecgi.cgi failing to properly filter special characters and commands in constructed commands. An attacker can exploit this vulnerability to execute arbitrary commands on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51027"
},
{
"db": "CNVD",
"id": "CNVD-2024-21661"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-51027",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2024-21661",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21661"
},
{
"db": "NVD",
"id": "CVE-2023-51027"
}
]
},
"id": "VAR-202312-2147",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21661"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21661"
}
]
},
"last_update_date": "2024-05-12T03:46:41.327000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51027"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://815yang.github.io/2023/12/11/ex1800t/2/3/totolinkex1800t_v9.1.0cu.2112_b20220316setwifiextenderconfig-apcliauthmode/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-51027"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21661"
},
{
"db": "NVD",
"id": "CVE-2023-51027"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-21661"
},
{
"db": "NVD",
"id": "CVE-2023-51027"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21661"
},
{
"date": "2023-12-22T18:15:07.953000",
"db": "NVD",
"id": "CVE-2023-51027"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21661"
},
{
"date": "2023-12-27T21:10:41.763000",
"db": "NVD",
"id": "CVE-2023-51027"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK EX1800T setWiFiExtenderConfig interface command execution vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21661"
}
],
"trust": 0.6
}
}
VAR-202312-1108
Vulnerability from variot - Updated: 2024-05-12 03:45TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the ‘tz’ parameter of the setNtpCfg interface of the cstecgi .cgi. TOTOLINK EX1800T is a Wi-Fi range extender from China's TOTOLINK Electronics. The vulnerability is caused by the tz parameter of the setNtpCfg interface of cstecgi.cgi failing to properly filter special characters and commands in the constructed command. An attacker can exploit this vulnerability to execute arbitrary commands on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-1108",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ex1800t",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0cu.2112_b20220316"
},
{
"model": "ex1800t v9.1.0cu.2112 b20220316",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21656"
},
{
"db": "NVD",
"id": "CVE-2023-51024"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:totolink:ex1800t_firmware:9.1.0cu.2112_b20220316:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51024"
}
]
},
"cve": "CVE-2023-51024",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-21656",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-51024",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-21656",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21656"
},
{
"db": "NVD",
"id": "CVE-2023-51024"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the \u2018tz\u2019 parameter of the setNtpCfg interface of the cstecgi .cgi. TOTOLINK EX1800T is a Wi-Fi range extender from China\u0027s TOTOLINK Electronics. The vulnerability is caused by the tz parameter of the setNtpCfg interface of cstecgi.cgi failing to properly filter special characters and commands in the constructed command. An attacker can exploit this vulnerability to execute arbitrary commands on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51024"
},
{
"db": "CNVD",
"id": "CNVD-2024-21656"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-51024",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2024-21656",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21656"
},
{
"db": "NVD",
"id": "CVE-2023-51024"
}
]
},
"id": "VAR-202312-1108",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21656"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21656"
}
]
},
"last_update_date": "2024-05-12T03:45:39.619000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51024"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://815yang.github.io/2023/12/11/ex1800t/2/totolinkex1800t_v9.1.0cu.2112_b2022031setntpcfg-tz/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-51024"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21656"
},
{
"db": "NVD",
"id": "CVE-2023-51024"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-21656"
},
{
"db": "NVD",
"id": "CVE-2023-51024"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21656"
},
{
"date": "2023-12-22T18:15:07.820000",
"db": "NVD",
"id": "CVE-2023-51024"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21656"
},
{
"date": "2023-12-27T21:11:05.060000",
"db": "NVD",
"id": "CVE-2023-51024"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK EX1800T setNtpCfg interface command execution vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21656"
}
],
"trust": 0.6
}
}
VAR-202312-0941
Vulnerability from variot - Updated: 2024-05-12 03:43TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the ‘merge’ parameter of the setRptWizardCfg interface of the cstecgi .cgi. TOTOLINK of ex1800t There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China's TOTOLINK Electronics. The vulnerability is caused by the fact that the merge parameter of the setRptWizardCfg interface of cstecgi.cgi fails to properly filter special characters and commands in the constructed command. Attackers can exploit this vulnerability to execute arbitrary commands on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-0941",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ex1800t",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0cu.2112_b20220316"
},
{
"model": "ex1800t",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex1800t",
"scope": null,
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex1800t",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": "ex1800t firmware 9.1.0cu.2112 b20220316"
},
{
"model": "ex1800t v9.1.0cu.2112 b20220316",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21659"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023769"
},
{
"db": "NVD",
"id": "CVE-2023-51021"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:totolink:ex1800t_firmware:9.1.0cu.2112_b20220316:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51021"
}
]
},
"cve": "CVE-2023-51021",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-21659",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-51021",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-51021",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-21659",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21659"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023769"
},
{
"db": "NVD",
"id": "CVE-2023-51021"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the \u2018merge\u2019 parameter of the setRptWizardCfg interface of the cstecgi .cgi. TOTOLINK of ex1800t There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China\u0027s TOTOLINK Electronics. The vulnerability is caused by the fact that the merge parameter of the setRptWizardCfg interface of cstecgi.cgi fails to properly filter special characters and commands in the constructed command. Attackers can exploit this vulnerability to execute arbitrary commands on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51021"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023769"
},
{
"db": "CNVD",
"id": "CNVD-2024-21659"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-51021",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023769",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-21659",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21659"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023769"
},
{
"db": "NVD",
"id": "CVE-2023-51021"
}
]
},
"id": "VAR-202312-0941",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21659"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21659"
}
]
},
"last_update_date": "2024-05-12T03:43:42.576000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023769"
},
{
"db": "NVD",
"id": "CVE-2023-51021"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://815yang.github.io/2023/12/11/ex1800t/2/totolinkex1800t_v9.1.0cu.2112_b20220316setrptwizardcfg-merge/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-51021"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21659"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023769"
},
{
"db": "NVD",
"id": "CVE-2023-51021"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-21659"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023769"
},
{
"db": "NVD",
"id": "CVE-2023-51021"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21659"
},
{
"date": "2024-01-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-023769"
},
{
"date": "2023-12-22T19:15:09.737000",
"db": "NVD",
"id": "CVE-2023-51021"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21659"
},
{
"date": "2024-01-29T07:35:00",
"db": "JVNDB",
"id": "JVNDB-2023-023769"
},
{
"date": "2023-12-27T21:08:51.647000",
"db": "NVD",
"id": "CVE-2023-51021"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK\u00a0 of \u00a0ex1800t\u00a0 Firmware vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023769"
}
],
"trust": 0.8
}
}
VAR-202312-1976
Vulnerability from variot - Updated: 2024-05-12 03:42TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the ‘key5g’ parameter of the setWiFiExtenderConfig interface of the cstecgi .cgi. TOTOLINK of ex1800t There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China's TOTOLINK Electronics. The vulnerability is caused by the key5g parameter of the setWiFiExtenderConfig interface of cstecgi.cgi failing to properly filter special characters and commands in the constructed command. An attacker can exploit this vulnerability to execute arbitrary commands on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-1976",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ex1800t",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0cu.2112_b20220316"
},
{
"model": "ex1800t",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex1800t",
"scope": null,
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex1800t",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": "ex1800t firmware 9.1.0cu.2112 b20220316"
},
{
"model": "ex1800t v9.1.0cu.2112 b20220316",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21662"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023771"
},
{
"db": "NVD",
"id": "CVE-2023-51019"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:totolink:ex1800t_firmware:9.1.0cu.2112_b20220316:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51019"
}
]
},
"cve": "CVE-2023-51019",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-21662",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-51019",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-51019",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-21662",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21662"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023771"
},
{
"db": "NVD",
"id": "CVE-2023-51019"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the \u2018key5g\u2019 parameter of the setWiFiExtenderConfig interface of the cstecgi .cgi. TOTOLINK of ex1800t There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China\u0027s TOTOLINK Electronics. The vulnerability is caused by the key5g parameter of the setWiFiExtenderConfig interface of cstecgi.cgi failing to properly filter special characters and commands in the constructed command. An attacker can exploit this vulnerability to execute arbitrary commands on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51019"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023771"
},
{
"db": "CNVD",
"id": "CNVD-2024-21662"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-51019",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023771",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-21662",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21662"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023771"
},
{
"db": "NVD",
"id": "CVE-2023-51019"
}
]
},
"id": "VAR-202312-1976",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21662"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21662"
}
]
},
"last_update_date": "2024-05-12T03:42:05.752000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023771"
},
{
"db": "NVD",
"id": "CVE-2023-51019"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://815yang.github.io/2023/12/11/ex1800t/2/totolinkex1800t_v9.1.0cu.2112_b20220316setwifiextenderconfig-key5g/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-51019"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-21662"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023771"
},
{
"db": "NVD",
"id": "CVE-2023-51019"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-21662"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023771"
},
{
"db": "NVD",
"id": "CVE-2023-51019"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21662"
},
{
"date": "2024-01-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-023771"
},
{
"date": "2023-12-22T19:15:09.630000",
"db": "NVD",
"id": "CVE-2023-51019"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-21662"
},
{
"date": "2024-01-29T07:35:00",
"db": "JVNDB",
"id": "JVNDB-2023-023771"
},
{
"date": "2023-12-27T21:09:43.747000",
"db": "NVD",
"id": "CVE-2023-51019"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK\u00a0 of \u00a0ex1800t\u00a0 Firmware vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023771"
}
],
"trust": 0.8
}
}
VAR-202401-2457
Vulnerability from variot - Updated: 2024-03-19 23:07TOTOlink EX1800T V9.1.0cu.2112_B20220316 was discovered to contain a remote command execution (RCE) vulnerability via the telnet_enabled parameter of the setTelnetCfg interface. TOTOLINK EX1800T is a Wi-Fi range extender from China's Zeon Electronics (TOTOLINK) company. An attacker could exploit this vulnerability to execute arbitrary commands on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202401-2457",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ex1800t",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0cu.2112_b20220316"
},
{
"model": "ex1800t v9.1.0cu.2112 b20220316",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-13795"
},
{
"db": "NVD",
"id": "CVE-2023-52026"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:totolink:ex1800t_firmware:9.1.0cu.2112_b20220316:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-52026"
}
]
},
"cve": "CVE-2023-52026",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-13795",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-52026",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-13795",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-13795"
},
{
"db": "NVD",
"id": "CVE-2023-52026"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOlink EX1800T V9.1.0cu.2112_B20220316 was discovered to contain a remote command execution (RCE) vulnerability via the telnet_enabled parameter of the setTelnetCfg interface. TOTOLINK EX1800T is a Wi-Fi range extender from China\u0027s Zeon Electronics (TOTOLINK) company. An attacker could exploit this vulnerability to execute arbitrary commands on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-52026"
},
{
"db": "CNVD",
"id": "CNVD-2024-13795"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-52026",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2024-13795",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-13795"
},
{
"db": "NVD",
"id": "CVE-2023-52026"
}
]
},
"id": "VAR-202401-2457",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-13795"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-13795"
}
]
},
"last_update_date": "2024-03-19T23:07:14.032000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-52026"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://815yang.github.io/2023/12/11/ex1800t/2/totolinkex1800t_v9.1.0cu.2112_b2022031settelnetcfg/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-52026"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-13795"
},
{
"db": "NVD",
"id": "CVE-2023-52026"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-13795"
},
{
"db": "NVD",
"id": "CVE-2023-52026"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-03-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-13795"
},
{
"date": "2024-01-12T13:15:11.860000",
"db": "NVD",
"id": "CVE-2023-52026"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-03-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-13795"
},
{
"date": "2024-01-18T20:20:30.330000",
"db": "NVD",
"id": "CVE-2023-52026"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK EX1800T command execution vulnerability (CNVD-2024-13795)",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-13795"
}
],
"trust": 0.6
}
}
VAR-202312-1594
Vulnerability from variot - Updated: 2024-03-19 22:48TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the ‘langFlag’ parameter of the setLanguageCfg interface of the cstecgi .cgi. TOTOLINK of ex1800t There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China's Zeon Electronics (TOTOLINK) company.
TOTOLINK EX1800T has a command execution vulnerability. This vulnerability stems from the failure of the langFlag parameter of the setLanguageCfg interface of cstecgi.cgi to correctly filter special characters, commands, etc. in the constructed command. An attacker could exploit this vulnerability to execute arbitrary commands on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-1594",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ex1800t",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0cu.2112_b20220316"
},
{
"model": "ex1800t",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex1800t",
"scope": null,
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex1800t",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": "ex1800t firmware 9.1.0cu.2112 b20220316"
},
{
"model": "ex1800t v9.1.0cu.2112 b20220316",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-13794"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023768"
},
{
"db": "NVD",
"id": "CVE-2023-51022"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:totolink:ex1800t_firmware:9.1.0cu.2112_b20220316:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51022"
}
]
},
"cve": "CVE-2023-51022",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-13794",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-51022",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-51022",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-13794",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-13794"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023768"
},
{
"db": "NVD",
"id": "CVE-2023-51022"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the \u2018langFlag\u2019 parameter of the setLanguageCfg interface of the cstecgi .cgi. TOTOLINK of ex1800t There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China\u0027s Zeon Electronics (TOTOLINK) company. \n\r\n\r\nTOTOLINK EX1800T has a command execution vulnerability. This vulnerability stems from the failure of the langFlag parameter of the setLanguageCfg interface of cstecgi.cgi to correctly filter special characters, commands, etc. in the constructed command. An attacker could exploit this vulnerability to execute arbitrary commands on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51022"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023768"
},
{
"db": "CNVD",
"id": "CNVD-2024-13794"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-51022",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023768",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-13794",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-13794"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023768"
},
{
"db": "NVD",
"id": "CVE-2023-51022"
}
]
},
"id": "VAR-202312-1594",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-13794"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-13794"
}
]
},
"last_update_date": "2024-03-19T22:48:06.559000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023768"
},
{
"db": "NVD",
"id": "CVE-2023-51022"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://815yang.github.io/2023/12/11/ex1800t/2/3/totolinkex1800t_v9.1.0cu.2112_b20220316setlanguagecfg-langflag/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-51022"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-13794"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023768"
},
{
"db": "NVD",
"id": "CVE-2023-51022"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-13794"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023768"
},
{
"db": "NVD",
"id": "CVE-2023-51022"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-03-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-13794"
},
{
"date": "2024-01-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-023768"
},
{
"date": "2023-12-22T19:15:09.787000",
"db": "NVD",
"id": "CVE-2023-51022"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-03-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-13794"
},
{
"date": "2024-01-29T07:35:00",
"db": "JVNDB",
"id": "JVNDB-2023-023768"
},
{
"date": "2023-12-27T21:08:45.027000",
"db": "NVD",
"id": "CVE-2023-51022"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK\u00a0 of \u00a0ex1800t\u00a0 Firmware vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023768"
}
],
"trust": 0.8
}
}
VAR-202312-0768
Vulnerability from variot - Updated: 2024-02-07 23:03TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the lanIp parameter’ of the setLanConfig interface of the cstecgi .cgi. TOTOLINK of ex1800t There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China's Zeon Electronics (TOTOLINK) company.
There is a command execution vulnerability in the TOTOLINK EX1800T lanIp parameter. This vulnerability stems from the failure of the lanIp parameter of the setLanConfig interface of cstecgi.cgi to correctly filter special characters, commands, etc. in the constructed command. An attacker could exploit this vulnerability to execute arbitrary commands on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-0768",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ex1800t",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0cu.2112_b20220316"
},
{
"model": "ex1800t",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex1800t",
"scope": null,
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex1800t",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": "ex1800t firmware 9.1.0cu.2112 b20220316"
},
{
"model": "ex1800t v9.1.0cu.2112 b20220316",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-07858"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023773"
},
{
"db": "NVD",
"id": "CVE-2023-51017"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:totolink:ex1800t_firmware:9.1.0cu.2112_b20220316:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51017"
}
]
},
"cve": "CVE-2023-51017",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-07858",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-51017",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-51017",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-07858",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-07858"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023773"
},
{
"db": "NVD",
"id": "CVE-2023-51017"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the lanIp parameter\u2019 of the setLanConfig interface of the cstecgi .cgi. TOTOLINK of ex1800t There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK EX1800T is a Wi-Fi range extender from China\u0027s Zeon Electronics (TOTOLINK) company. \n\r\n\r\nThere is a command execution vulnerability in the TOTOLINK EX1800T lanIp parameter. This vulnerability stems from the failure of the lanIp parameter of the setLanConfig interface of cstecgi.cgi to correctly filter special characters, commands, etc. in the constructed command. An attacker could exploit this vulnerability to execute arbitrary commands on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51017"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023773"
},
{
"db": "CNVD",
"id": "CNVD-2024-07858"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-51017",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023773",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-07858",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-07858"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023773"
},
{
"db": "NVD",
"id": "CVE-2023-51017"
}
]
},
"id": "VAR-202312-0768",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-07858"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-07858"
}
]
},
"last_update_date": "2024-02-07T23:03:55.083000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023773"
},
{
"db": "NVD",
"id": "CVE-2023-51017"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://815yang.github.io/2023/12/11/ex1800t/totolinkex1800t_v9.1.0cu.2112_b2022031setlanconfig-lanip/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-51017"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-07858"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023773"
},
{
"db": "NVD",
"id": "CVE-2023-51017"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-07858"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023773"
},
{
"db": "NVD",
"id": "CVE-2023-51017"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-02-06T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-07858"
},
{
"date": "2024-01-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-023773"
},
{
"date": "2023-12-22T19:15:09.540000",
"db": "NVD",
"id": "CVE-2023-51017"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-02-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-07858"
},
{
"date": "2024-01-29T07:35:00",
"db": "JVNDB",
"id": "JVNDB-2023-023773"
},
{
"date": "2023-12-27T21:09:57.983000",
"db": "NVD",
"id": "CVE-2023-51017"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK\u00a0 of \u00a0ex1800t\u00a0 Firmware vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023773"
}
],
"trust": 0.8
}
}
VAR-202312-1776
Vulnerability from variot - Updated: 2024-01-20 23:10TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to arbitrary command execution in the ‘host_time’ parameter of the NTPSyncWithHost interface of the cstecgi .cgi. TOTOLINK EX1800T is a Wi-Fi range extender from China's Zeon Electronics (TOTOLINK) company.
TOTOLINK EX1800T v9.1.0cu.2112_B20220316 version has a command execution vulnerability. The vulnerability stems from the failure of the host_time parameter of the NTPSyncWithHost interface of cstecgi.cgi to correctly filter special characters, commands, etc. in the constructed command
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-1776",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ex1800t",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0cu.2112_b20220316"
},
{
"model": "ex1800t v9.1.0cu.2112 b20220316",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-04913"
},
{
"db": "NVD",
"id": "CVE-2023-51023"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:totolink:ex1800t_firmware:9.1.0cu.2112_b20220316:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:totolink:ex1800t:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51023"
}
]
},
"cve": "CVE-2023-51023",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-04913",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-51023",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-04913",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-04913"
},
{
"db": "NVD",
"id": "CVE-2023-51023"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to arbitrary command execution in the \u2018host_time\u2019 parameter of the NTPSyncWithHost interface of the cstecgi .cgi. TOTOLINK EX1800T is a Wi-Fi range extender from China\u0027s Zeon Electronics (TOTOLINK) company. \n\r\n\r\nTOTOLINK EX1800T v9.1.0cu.2112_B20220316 version has a command execution vulnerability. The vulnerability stems from the failure of the host_time parameter of the NTPSyncWithHost interface of cstecgi.cgi to correctly filter special characters, commands, etc. in the constructed command",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51023"
},
{
"db": "CNVD",
"id": "CNVD-2024-04913"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-51023",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2024-04913",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-04913"
},
{
"db": "NVD",
"id": "CVE-2023-51023"
}
]
},
"id": "VAR-202312-1776",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-04913"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-04913"
}
]
},
"last_update_date": "2024-01-20T23:10:26.329000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51023"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://815yang.github.io/2023/12/11/ex1800t/2/totolinkex1800t_v9.1.0cu.2112_b2022031ntpsyncwithhost-host_time/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-51023"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-04913"
},
{
"db": "NVD",
"id": "CVE-2023-51023"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-04913"
},
{
"db": "NVD",
"id": "CVE-2023-51023"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-04913"
},
{
"date": "2023-12-22T18:15:07.770000",
"db": "NVD",
"id": "CVE-2023-51023"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-04913"
},
{
"date": "2023-12-27T21:11:11.397000",
"db": "NVD",
"id": "CVE-2023-51023"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK EX1800T NTPSyncWithHost interface command execution vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-04913"
}
],
"trust": 0.6
}
}