Search criteria
4 vulnerabilities found for Ethernet Controller 3rd Generation by WAGO
CVE-2018-25090 (GCVE-0-2018-25090)
Vulnerability from cvelistv5 – Published: 2024-03-13 08:32 – Updated: 2024-08-05 15:22
VLAI?
Summary
An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required. This leads to a limited impact of confidentiality and integrity but no impact of availability.
Severity ?
5.4 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | Controller BACnet/IP |
Affected:
0 , ≤ FW13
(semver)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:33:48.504Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2018-25090",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-05T15:21:55.909544Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-05T15:22:05.933Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Controller BACnet/IP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Controller BACnet MS/TP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Fieldbus Coupler Ethernet 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required.\u0026nbsp;This leads to a limited impact of confidentiality and integrity but no impact of availability."
}
],
"value": "An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required.\u00a0This leads to a limited impact of confidentiality and integrity but no impact of availability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T08:32:17.180Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"source": {
"advisory": "VDE-2023-039",
"defect": [
"CERT@VDE#64546"
],
"discovery": "EXTERNAL"
},
"title": "Wago: Improper Neutralization of Input During Web Page Generation in multiple devices",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2018-25090",
"datePublished": "2024-03-13T08:32:17.180Z",
"dateReserved": "2023-09-14T13:00:21.075Z",
"dateUpdated": "2024-08-05T15:22:05.933Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-10123 (GCVE-0-2015-10123)
Vulnerability from cvelistv5 – Published: 2024-03-13 08:31 – Updated: 2024-10-23 09:40
VLAI?
Summary
An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device.
Severity ?
8.8 (High)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | Controller BACnet/IP |
Affected:
0 , ≤ FW13
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T08:58:26.532Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:wago:750-352_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-352_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-831_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-831_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-829_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-829_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-852_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-852_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-880_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-880_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-881_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-881_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-882_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-882_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-885_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-885_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-889_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-889_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-884_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-884_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2015-10123",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-06T18:34:04.204030Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-06T19:37:09.871Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Controller BACnet/IP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Controller BACnet MS/TP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Fieldbus Coupler Ethernet 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device.\u003cbr\u003e"
}
],
"value": "An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T09:40:12.408Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"source": {
"advisory": "VDE-2023-039",
"defect": [
"CERT@VDE#64546"
],
"discovery": "EXTERNAL"
},
"title": "Wago: Buffer Copy without Checking Size of Input in wbm of multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2015-10123",
"datePublished": "2024-03-13T08:31:55.341Z",
"dateReserved": "2023-09-14T13:00:03.904Z",
"dateUpdated": "2024-10-23T09:40:12.408Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-25090 (GCVE-0-2018-25090)
Vulnerability from nvd – Published: 2024-03-13 08:32 – Updated: 2024-08-05 15:22
VLAI?
Summary
An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required. This leads to a limited impact of confidentiality and integrity but no impact of availability.
Severity ?
5.4 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | Controller BACnet/IP |
Affected:
0 , ≤ FW13
(semver)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:33:48.504Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2018-25090",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-05T15:21:55.909544Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-05T15:22:05.933Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Controller BACnet/IP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Controller BACnet MS/TP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Fieldbus Coupler Ethernet 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required.\u0026nbsp;This leads to a limited impact of confidentiality and integrity but no impact of availability."
}
],
"value": "An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required.\u00a0This leads to a limited impact of confidentiality and integrity but no impact of availability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T08:32:17.180Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"source": {
"advisory": "VDE-2023-039",
"defect": [
"CERT@VDE#64546"
],
"discovery": "EXTERNAL"
},
"title": "Wago: Improper Neutralization of Input During Web Page Generation in multiple devices",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2018-25090",
"datePublished": "2024-03-13T08:32:17.180Z",
"dateReserved": "2023-09-14T13:00:21.075Z",
"dateUpdated": "2024-08-05T15:22:05.933Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-10123 (GCVE-0-2015-10123)
Vulnerability from nvd – Published: 2024-03-13 08:31 – Updated: 2024-10-23 09:40
VLAI?
Summary
An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device.
Severity ?
8.8 (High)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | Controller BACnet/IP |
Affected:
0 , ≤ FW13
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T08:58:26.532Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:wago:750-352_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-352_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-831_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-831_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-829_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-829_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-852_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-852_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-880_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-880_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-881_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-881_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-882_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-882_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-885_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-885_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-889_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-889_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:wago:750-884_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "750-884_firmware",
"vendor": "wago",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2015-10123",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-06T18:34:04.204030Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-06T19:37:09.871Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Controller BACnet/IP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Controller BACnet MS/TP",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Ethernet Controller 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Fieldbus Coupler Ethernet 3rd Generation",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device.\u003cbr\u003e"
}
],
"value": "An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T09:40:12.408Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-039/"
}
],
"source": {
"advisory": "VDE-2023-039",
"defect": [
"CERT@VDE#64546"
],
"discovery": "EXTERNAL"
},
"title": "Wago: Buffer Copy without Checking Size of Input in wbm of multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2015-10123",
"datePublished": "2024-03-13T08:31:55.341Z",
"dateReserved": "2023-09-14T13:00:03.904Z",
"dateUpdated": "2024-10-23T09:40:12.408Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}