Search criteria

2 vulnerabilities found for Fabric Engine (VOSS) by Extreme Networks

CVE-2025-11192 (GCVE-0-2025-11192)

Vulnerability from cvelistv5 – Published: 2025-10-07 19:07 – Updated: 2025-10-08 15:45
VLAI?
Summary
A vulnerability in Extreme Networks’ Fabric Engine (VOSS) before 9.3 was discovered. When SD-WAN AutoSense is enabled on a port, it may automatically configure fabric connectivity without validating ISIS authentication settings. The SD-WAN AutoSense implementation may be exploited by malicious actors by allowing unauthorized access to network fabric and configuration data.
CWE
  • CWE-287 - Improper Authentication
Assigner
Impacted products
Vendor Product Version
Extreme Networks Fabric Engine (VOSS) Affected: 9.2 , ≤ <9.2 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11192",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-08T15:45:45.732039Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-08T15:45:56.015Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric Engine (VOSS)",
          "vendor": "Extreme Networks",
          "versions": [
            {
              "changes": [
                {
                  "at": "9.3",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "\u003c9.2",
              "status": "affected",
              "version": "9.2",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003eA vulnerability in Extreme Networks\u2019 Fabric Engine (VOSS) before 9.3 was discovered. When SD-WAN AutoSense is enabled on a port, it may automatically configure fabric connectivity without validating ISIS authentication settings. The SD-WAN AutoSense implementation may be exploited by malicious actors by allowing unauthorized access to network fabric and configuration data.\u003c/div\u003e\u003c/div\u003e\u003c/div\u003e\u003cbr\u003e"
            }
          ],
          "value": "A vulnerability in Extreme Networks\u2019 Fabric Engine (VOSS) before 9.3 was discovered. When SD-WAN AutoSense is enabled on a port, it may automatically configure fabric connectivity without validating ISIS authentication settings. The SD-WAN AutoSense implementation may be exploited by malicious actors by allowing unauthorized access to network fabric and configuration data."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "PHYSICAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T19:07:45.086Z",
        "orgId": "1c053176-eef3-4d6a-ae0b-24728c86587b",
        "shortName": "ExtremeNetworks"
      },
      "references": [
        {
          "url": "https://extreme-networks.my.site.com/ExtrArticleDetail?an=000130291"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eFixed in 9.3 or later.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "Fixed in 9.3 or later."
        }
      ],
      "source": {
        "advisory": "SA-2025-115",
        "discovery": "USER"
      },
      "title": "Fabric Engine (VOSS) AutoSense Authentication Bypass",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1c053176-eef3-4d6a-ae0b-24728c86587b",
    "assignerShortName": "ExtremeNetworks",
    "cveId": "CVE-2025-11192",
    "datePublished": "2025-10-07T19:07:45.086Z",
    "dateReserved": "2025-09-30T13:38:06.105Z",
    "dateUpdated": "2025-10-08T15:45:56.015Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-11192 (GCVE-0-2025-11192)

Vulnerability from nvd – Published: 2025-10-07 19:07 – Updated: 2025-10-08 15:45
VLAI?
Summary
A vulnerability in Extreme Networks’ Fabric Engine (VOSS) before 9.3 was discovered. When SD-WAN AutoSense is enabled on a port, it may automatically configure fabric connectivity without validating ISIS authentication settings. The SD-WAN AutoSense implementation may be exploited by malicious actors by allowing unauthorized access to network fabric and configuration data.
CWE
  • CWE-287 - Improper Authentication
Assigner
Impacted products
Vendor Product Version
Extreme Networks Fabric Engine (VOSS) Affected: 9.2 , ≤ <9.2 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11192",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-08T15:45:45.732039Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-08T15:45:56.015Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric Engine (VOSS)",
          "vendor": "Extreme Networks",
          "versions": [
            {
              "changes": [
                {
                  "at": "9.3",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "\u003c9.2",
              "status": "affected",
              "version": "9.2",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003eA vulnerability in Extreme Networks\u2019 Fabric Engine (VOSS) before 9.3 was discovered. When SD-WAN AutoSense is enabled on a port, it may automatically configure fabric connectivity without validating ISIS authentication settings. The SD-WAN AutoSense implementation may be exploited by malicious actors by allowing unauthorized access to network fabric and configuration data.\u003c/div\u003e\u003c/div\u003e\u003c/div\u003e\u003cbr\u003e"
            }
          ],
          "value": "A vulnerability in Extreme Networks\u2019 Fabric Engine (VOSS) before 9.3 was discovered. When SD-WAN AutoSense is enabled on a port, it may automatically configure fabric connectivity without validating ISIS authentication settings. The SD-WAN AutoSense implementation may be exploited by malicious actors by allowing unauthorized access to network fabric and configuration data."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "PHYSICAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T19:07:45.086Z",
        "orgId": "1c053176-eef3-4d6a-ae0b-24728c86587b",
        "shortName": "ExtremeNetworks"
      },
      "references": [
        {
          "url": "https://extreme-networks.my.site.com/ExtrArticleDetail?an=000130291"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eFixed in 9.3 or later.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "Fixed in 9.3 or later."
        }
      ],
      "source": {
        "advisory": "SA-2025-115",
        "discovery": "USER"
      },
      "title": "Fabric Engine (VOSS) AutoSense Authentication Bypass",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1c053176-eef3-4d6a-ae0b-24728c86587b",
    "assignerShortName": "ExtremeNetworks",
    "cveId": "CVE-2025-11192",
    "datePublished": "2025-10-07T19:07:45.086Z",
    "dateReserved": "2025-09-30T13:38:06.105Z",
    "dateUpdated": "2025-10-08T15:45:56.015Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}