CVE-2023-46290 (GCVE-0-2023-46290)
Vulnerability from cvelistv5 – Published: 2023-10-27 18:10 – Updated: 2025-02-27 20:39
VLAI?
Summary
Due to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk® Services Platform web service and then use the token to log in into FactoryTalk® Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk® Services Platform web service.
Severity ?
8.1 (High)
CWE
- CWE-287 - Improper Authentication
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Rockwell Automation | FactoryTalk® Services Platform |
Affected:
versions before 2.80
|
Credits
This vulnerability was found internally during routine testing.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:45:40.833Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-46290",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:49:21.323063Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T20:39:11.981Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk\u00ae Services Platform",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "versions before 2.80"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": " This vulnerability was found internally during routine testing."
}
],
"datePublic": "2023-10-26T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDue to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk\u00ae Services Platform web service and then use the token to log in into FactoryTalk\u00ae Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk\u00ae Services Platform web service.\u003c/span\u003e\n\n"
}
],
"value": "\nDue to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk\u00ae Services Platform web service and then use the token to log in into FactoryTalk\u00ae Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk\u00ae Services Platform web service.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-633",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-633 Token Impersonation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-27T18:10:50.923Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cul\u003e\u003cli\u003eInstall the respective \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductCompareSelections.aspx?crumb=113\u0026amp;versions=61602,60883,59837,59480,58564,57413,58591,59481,59482,59483,59484,59485,59486,59487,59488,59490,59491,59492,59493,59494,59495,59496\"\u003eFactoryTalk Services Version\u003c/a\u003e\u0026nbsp;that remediates the issue.\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012\"\u003eQA43240 - Recommended Security Guidelines from Rockwell Automation\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "\n * Install the respective FactoryTalk Services Version https://compatibility.rockwellautomation.com/Pages/MultiProductCompareSelections.aspx \u00a0that remediates the issue.\n * QA43240 - Recommended Security Guidelines from Rockwell Automation https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012 \n\n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Rockwell Automation FactoryTalk Services Platform Elevated Privileges Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2023-46290",
"datePublished": "2023-10-27T18:10:50.923Z",
"dateReserved": "2023-10-20T18:01:46.095Z",
"dateUpdated": "2025-02-27T20:39:11.981Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46290 (GCVE-0-2023-46290)
Vulnerability from nvd – Published: 2023-10-27 18:10 – Updated: 2025-02-27 20:39
VLAI?
Summary
Due to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk® Services Platform web service and then use the token to log in into FactoryTalk® Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk® Services Platform web service.
Severity ?
8.1 (High)
CWE
- CWE-287 - Improper Authentication
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Rockwell Automation | FactoryTalk® Services Platform |
Affected:
versions before 2.80
|
Credits
This vulnerability was found internally during routine testing.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:45:40.833Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-46290",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:49:21.323063Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T20:39:11.981Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk\u00ae Services Platform",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "versions before 2.80"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": " This vulnerability was found internally during routine testing."
}
],
"datePublic": "2023-10-26T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDue to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk\u00ae Services Platform web service and then use the token to log in into FactoryTalk\u00ae Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk\u00ae Services Platform web service.\u003c/span\u003e\n\n"
}
],
"value": "\nDue to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk\u00ae Services Platform web service and then use the token to log in into FactoryTalk\u00ae Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk\u00ae Services Platform web service.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-633",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-633 Token Impersonation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-27T18:10:50.923Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cul\u003e\u003cli\u003eInstall the respective \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductCompareSelections.aspx?crumb=113\u0026amp;versions=61602,60883,59837,59480,58564,57413,58591,59481,59482,59483,59484,59485,59486,59487,59488,59490,59491,59492,59493,59494,59495,59496\"\u003eFactoryTalk Services Version\u003c/a\u003e\u0026nbsp;that remediates the issue.\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012\"\u003eQA43240 - Recommended Security Guidelines from Rockwell Automation\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "\n * Install the respective FactoryTalk Services Version https://compatibility.rockwellautomation.com/Pages/MultiProductCompareSelections.aspx \u00a0that remediates the issue.\n * QA43240 - Recommended Security Guidelines from Rockwell Automation https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012 \n\n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Rockwell Automation FactoryTalk Services Platform Elevated Privileges Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2023-46290",
"datePublished": "2023-10-27T18:10:50.923Z",
"dateReserved": "2023-10-20T18:01:46.095Z",
"dateUpdated": "2025-02-27T20:39:11.981Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}