Search criteria
2 vulnerabilities found for FactoryTalk ViewPoint by Rockwell Automation
CVE-2025-9066 (GCVE-0-2025-9066)
Vulnerability from cvelistv5 – Published: 2025-10-14 12:15 – Updated: 2025-10-14 18:44
VLAI?
Summary
A security issue was discovered within FactoryTalk® ViewPoint, allowing unauthenticated attackers to achieve XXE. Certain SOAP requests can be abused to perform XXE, resulting in a temporary denial-of-service.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Rockwell Automation | FactoryTalk ViewPoint |
Affected:
V14 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9066",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T18:44:43.240813Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T18:44:50.355Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk ViewPoint",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "V14 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue was discovered within FactoryTalk\u00ae ViewPoint, allowing unauthenticated attackers to achieve XXE. Certain SOAP requests can be abused to perform XXE, resulting in a temporary denial-of-service. \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
}
],
"value": "A security issue was discovered within FactoryTalk\u00ae ViewPoint, allowing unauthenticated attackers to achieve XXE. Certain SOAP requests can be abused to perform XXE, resulting in a temporary denial-of-service."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T12:15:04.242Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1752html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cp\u003e-Panel View Plus 7 Standard and Panel View Plus 7 Performance Series A v12 ,v13, v14 patch AID \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1150944/loc/en_US\"\u003eBF30506\u003c/a\u003e\u0026nbsp; (firmware fix) \u003c/p\u003e\u0026nbsp;\u003c/div\u003e\u003cdiv\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e-Panel View Plus 7 Performance Series B \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112\u0026amp;mode=3\u0026amp;refSoft=1\u0026amp;versions=61168\"\u003eV14.103\u003c/a\u003e\u0026nbsp;\u003c/p\u003e\u003c/div\u003e"
}
],
"value": "-Panel View Plus 7 Standard and Panel View Plus 7 Performance Series A v12 ,v13, v14 patch AID BF30506 https://support.rockwellautomation.com/app/answers/answer_view/a_id/1150944/loc/en_US \u00a0 (firmware fix) \n\n\u00a0\n\n\n\n-Panel View Plus 7 Performance Series B V14.103 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx"
}
],
"source": {
"advisory": "SD1752",
"discovery": "INTERNAL"
},
"title": "Rockwell Automation FactoryTalk\u00ae ViewPoint XXE to Denial-of-Service Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2025-9066",
"datePublished": "2025-10-14T12:15:04.242Z",
"dateReserved": "2025-08-15T13:59:29.317Z",
"dateUpdated": "2025-10-14T18:44:50.355Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-9066 (GCVE-0-2025-9066)
Vulnerability from nvd – Published: 2025-10-14 12:15 – Updated: 2025-10-14 18:44
VLAI?
Summary
A security issue was discovered within FactoryTalk® ViewPoint, allowing unauthenticated attackers to achieve XXE. Certain SOAP requests can be abused to perform XXE, resulting in a temporary denial-of-service.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Rockwell Automation | FactoryTalk ViewPoint |
Affected:
V14 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9066",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T18:44:43.240813Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T18:44:50.355Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk ViewPoint",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "V14 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue was discovered within FactoryTalk\u00ae ViewPoint, allowing unauthenticated attackers to achieve XXE. Certain SOAP requests can be abused to perform XXE, resulting in a temporary denial-of-service. \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
}
],
"value": "A security issue was discovered within FactoryTalk\u00ae ViewPoint, allowing unauthenticated attackers to achieve XXE. Certain SOAP requests can be abused to perform XXE, resulting in a temporary denial-of-service."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T12:15:04.242Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1752html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cp\u003e-Panel View Plus 7 Standard and Panel View Plus 7 Performance Series A v12 ,v13, v14 patch AID \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1150944/loc/en_US\"\u003eBF30506\u003c/a\u003e\u0026nbsp; (firmware fix) \u003c/p\u003e\u0026nbsp;\u003c/div\u003e\u003cdiv\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e-Panel View Plus 7 Performance Series B \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112\u0026amp;mode=3\u0026amp;refSoft=1\u0026amp;versions=61168\"\u003eV14.103\u003c/a\u003e\u0026nbsp;\u003c/p\u003e\u003c/div\u003e"
}
],
"value": "-Panel View Plus 7 Standard and Panel View Plus 7 Performance Series A v12 ,v13, v14 patch AID BF30506 https://support.rockwellautomation.com/app/answers/answer_view/a_id/1150944/loc/en_US \u00a0 (firmware fix) \n\n\u00a0\n\n\n\n-Panel View Plus 7 Performance Series B V14.103 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx"
}
],
"source": {
"advisory": "SD1752",
"discovery": "INTERNAL"
},
"title": "Rockwell Automation FactoryTalk\u00ae ViewPoint XXE to Denial-of-Service Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2025-9066",
"datePublished": "2025-10-14T12:15:04.242Z",
"dateReserved": "2025-08-15T13:59:29.317Z",
"dateUpdated": "2025-10-14T18:44:50.355Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}