CVE-2024-21865 (GCVE-0-2024-21865)
Vulnerability from cvelistv5 – Published: 2024-03-25 04:11 – Updated: 2025-09-19 17:22
VLAI?
Summary
HGW BL1500HM Ver 002.001.013 and earlier contains a use of week credentials issue. A network-adjacent unauthenticated attacker may connect to the product via SSH and use a shell.
Severity ?
6.5 (Medium)
CWE
- CWE-1391 - Use of weak credentials
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KDDI CORPORATION | HGW BL1500HM |
Affected:
Ver 002.001.013 and earlier
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-21865",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-17T15:29:40.852705Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-19T17:22:54.820Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:27:36.343Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.au.com/support/service/internet/guide/modem/bl1500hm/firmware/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU93546510/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HGW BL1500HM",
"vendor": "KDDI CORPORATION",
"versions": [
{
"status": "affected",
"version": "Ver 002.001.013 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "HGW BL1500HM Ver 002.001.013 and earlier contains a use of week credentials issue. A network-adjacent unauthenticated attacker may connect to the product via SSH and use a shell."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1391",
"description": "Use of weak credentials",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-28T07:38:26.719Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://kddi-tech.com/contents/appendix_L2_06.html#20304f4c-af1b-49fd-c3b5-8d1f55fd8b4f"
},
{
"url": "https://jvn.jp/en/vu/JVNVU93546510/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2024-21865",
"datePublished": "2024-03-25T04:11:34.280Z",
"dateReserved": "2024-03-18T01:23:32.331Z",
"dateUpdated": "2025-09-19T17:22:54.820Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-29071 (GCVE-0-2024-29071)
Vulnerability from cvelistv5 – Published: 2024-03-25 03:42 – Updated: 2025-03-28 07:38
VLAI?
Summary
HGW BL1500HM Ver 002.001.013 and earlier contains a use of week credentials issue. A network-adjacent unauthenticated attacker may change the system settings.
Severity ?
8.8 (High)
CWE
- CWE-1391 - Use of weak credentials
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KDDI CORPORATION | HGW BL1500HM |
Affected:
Ver 002.001.013 and earlier
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:kddi:hgw_bli500hm_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hgw_bli500hm_firmware",
"vendor": "kddi",
"versions": [
{
"lessThanOrEqual": "002.001.013",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-29071",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-04T13:53:58.969525Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-04T13:55:29.279Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:03:51.863Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.au.com/support/service/internet/guide/modem/bl1500hm/firmware/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU93546510/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HGW BL1500HM",
"vendor": "KDDI CORPORATION",
"versions": [
{
"status": "affected",
"version": "Ver 002.001.013 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "HGW BL1500HM Ver 002.001.013 and earlier contains a use of week credentials issue. A network-adjacent unauthenticated attacker may change the system settings."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1391",
"description": "Use of weak credentials",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-28T07:38:42.105Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://kddi-tech.com/contents/appendix_L2_06.html#20304f4c-af1b-49fd-c3b5-8d1f55fd8b4f"
},
{
"url": "https://jvn.jp/en/vu/JVNVU93546510/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2024-29071",
"datePublished": "2024-03-25T03:42:31.070Z",
"dateReserved": "2024-03-18T01:23:31.527Z",
"dateUpdated": "2025-03-28T07:38:42.105Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-28041 (GCVE-0-2024-28041)
Vulnerability from cvelistv5 – Published: 2024-03-25 03:42 – Updated: 2025-03-28 07:39
VLAI?
Summary
HGW BL1500HM Ver 002.001.013 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary command.
Severity ?
8.8 (High)
CWE
- Arbitrary command execution
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KDDI CORPORATION | HGW BL1500HM |
Affected:
Ver 002.001.013 and earlier
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:kddi:hgw_bli500hm_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hgw_bli500hm_firmware",
"vendor": "kddi",
"versions": [
{
"lessThanOrEqual": "002.001.013",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-28041",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-17T15:30:23.593154Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-17T15:32:08.389Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:48:47.724Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.au.com/support/service/internet/guide/modem/bl1500hm/firmware/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU93546510/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HGW BL1500HM",
"vendor": "KDDI CORPORATION",
"versions": [
{
"status": "affected",
"version": "Ver 002.001.013 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "HGW BL1500HM Ver 002.001.013 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary command."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Arbitrary command execution",
"lang": "en-US",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-28T07:39:02.488Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://kddi-tech.com/contents/appendix_L2_06.html#20304f4c-af1b-49fd-c3b5-8d1f55fd8b4f"
},
{
"url": "https://jvn.jp/en/vu/JVNVU93546510/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2024-28041",
"datePublished": "2024-03-25T03:42:17.754Z",
"dateReserved": "2024-03-18T01:23:33.325Z",
"dateUpdated": "2025-03-28T07:39:02.488Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-21865 (GCVE-0-2024-21865)
Vulnerability from nvd – Published: 2024-03-25 04:11 – Updated: 2025-09-19 17:22
VLAI?
Summary
HGW BL1500HM Ver 002.001.013 and earlier contains a use of week credentials issue. A network-adjacent unauthenticated attacker may connect to the product via SSH and use a shell.
Severity ?
6.5 (Medium)
CWE
- CWE-1391 - Use of weak credentials
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KDDI CORPORATION | HGW BL1500HM |
Affected:
Ver 002.001.013 and earlier
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-21865",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-17T15:29:40.852705Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-19T17:22:54.820Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:27:36.343Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.au.com/support/service/internet/guide/modem/bl1500hm/firmware/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU93546510/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HGW BL1500HM",
"vendor": "KDDI CORPORATION",
"versions": [
{
"status": "affected",
"version": "Ver 002.001.013 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "HGW BL1500HM Ver 002.001.013 and earlier contains a use of week credentials issue. A network-adjacent unauthenticated attacker may connect to the product via SSH and use a shell."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1391",
"description": "Use of weak credentials",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-28T07:38:26.719Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://kddi-tech.com/contents/appendix_L2_06.html#20304f4c-af1b-49fd-c3b5-8d1f55fd8b4f"
},
{
"url": "https://jvn.jp/en/vu/JVNVU93546510/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2024-21865",
"datePublished": "2024-03-25T04:11:34.280Z",
"dateReserved": "2024-03-18T01:23:32.331Z",
"dateUpdated": "2025-09-19T17:22:54.820Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-29071 (GCVE-0-2024-29071)
Vulnerability from nvd – Published: 2024-03-25 03:42 – Updated: 2025-03-28 07:38
VLAI?
Summary
HGW BL1500HM Ver 002.001.013 and earlier contains a use of week credentials issue. A network-adjacent unauthenticated attacker may change the system settings.
Severity ?
8.8 (High)
CWE
- CWE-1391 - Use of weak credentials
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KDDI CORPORATION | HGW BL1500HM |
Affected:
Ver 002.001.013 and earlier
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:kddi:hgw_bli500hm_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hgw_bli500hm_firmware",
"vendor": "kddi",
"versions": [
{
"lessThanOrEqual": "002.001.013",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-29071",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-04T13:53:58.969525Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-04T13:55:29.279Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:03:51.863Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.au.com/support/service/internet/guide/modem/bl1500hm/firmware/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU93546510/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HGW BL1500HM",
"vendor": "KDDI CORPORATION",
"versions": [
{
"status": "affected",
"version": "Ver 002.001.013 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "HGW BL1500HM Ver 002.001.013 and earlier contains a use of week credentials issue. A network-adjacent unauthenticated attacker may change the system settings."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1391",
"description": "Use of weak credentials",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-28T07:38:42.105Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://kddi-tech.com/contents/appendix_L2_06.html#20304f4c-af1b-49fd-c3b5-8d1f55fd8b4f"
},
{
"url": "https://jvn.jp/en/vu/JVNVU93546510/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2024-29071",
"datePublished": "2024-03-25T03:42:31.070Z",
"dateReserved": "2024-03-18T01:23:31.527Z",
"dateUpdated": "2025-03-28T07:38:42.105Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-28041 (GCVE-0-2024-28041)
Vulnerability from nvd – Published: 2024-03-25 03:42 – Updated: 2025-03-28 07:39
VLAI?
Summary
HGW BL1500HM Ver 002.001.013 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary command.
Severity ?
8.8 (High)
CWE
- Arbitrary command execution
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KDDI CORPORATION | HGW BL1500HM |
Affected:
Ver 002.001.013 and earlier
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:kddi:hgw_bli500hm_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hgw_bli500hm_firmware",
"vendor": "kddi",
"versions": [
{
"lessThanOrEqual": "002.001.013",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-28041",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-17T15:30:23.593154Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-17T15:32:08.389Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:48:47.724Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.au.com/support/service/internet/guide/modem/bl1500hm/firmware/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU93546510/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HGW BL1500HM",
"vendor": "KDDI CORPORATION",
"versions": [
{
"status": "affected",
"version": "Ver 002.001.013 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "HGW BL1500HM Ver 002.001.013 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary command."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Arbitrary command execution",
"lang": "en-US",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-28T07:39:02.488Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://kddi-tech.com/contents/appendix_L2_06.html#20304f4c-af1b-49fd-c3b5-8d1f55fd8b4f"
},
{
"url": "https://jvn.jp/en/vu/JVNVU93546510/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2024-28041",
"datePublished": "2024-03-25T03:42:17.754Z",
"dateReserved": "2024-03-18T01:23:33.325Z",
"dateUpdated": "2025-03-28T07:39:02.488Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}