All the vulnerabilites related to Qolsys, Inc. - IQ Panel 4
cve-2024-0242
Vulnerability from cvelistv5
Published
2024-02-08 19:34
Modified
2024-08-01 17:41
Summary
Unauthorized access to settings in Qolsys IQ Panel 4 and IQ4 Hub
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-0242",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-09T16:33:51.654700Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-05T17:20:47.918Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T17:41:16.073Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-039-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "IQ Panel 4",
          "vendor": "Qolsys, Inc.",
          "versions": [
            {
              "lessThan": "4.4.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "IQ4 Hub",
          "vendor": "Qolsys, Inc.",
          "versions": [
            {
              "lessThan": "4.4.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Cody Jung"
        }
      ],
      "datePublic": "2024-02-08T19:16:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Under certain circumstances IQ Panel4 and IQ4 Hub panel software prior to version 4.4.2 could allow unauthorized access to settings."
            }
          ],
          "value": "Under certain circumstances IQ Panel4 and IQ4 Hub panel software prior to version 4.4.2 could allow unauthorized access to settings."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-212",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-212 Functionality Misuse"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-08T19:34:14.895Z",
        "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "shortName": "jci"
      },
      "references": [
        {
          "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-039-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade IQ Panel 4 to version 4.4.2.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade IQ Panel 4 to version 4.4.2.\n"
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade IQ4 Hub to version 4.4.2.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade IQ4 Hub to version 4.4.2.\n"
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The firmware can be updated remotely to all available devices in the field.\u003cbr\u003e"
            }
          ],
          "value": "The firmware can be updated remotely to all available devices in the field.\n"
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The firmware update can also be manually loaded by applying the patch tag \u201ciqpanel4.4.2\u201d on the device after navigating to its firmware update page.\u003cbr\u003e"
            }
          ],
          "value": "The firmware update can also be manually loaded by applying the patch tag \u201ciqpanel4.4.2\u201d on the device after navigating to its firmware update page.\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Unauthorized access to settings in Qolsys IQ Panel 4 and IQ4 Hub",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
    "assignerShortName": "jci",
    "cveId": "CVE-2024-0242",
    "datePublished": "2024-02-08T19:34:14.895Z",
    "dateReserved": "2024-01-04T19:27:40.165Z",
    "dateUpdated": "2024-08-01T17:41:16.073Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}