Search criteria
2 vulnerabilities found for Invenia ABUS by GE HealthCare
CVE-2024-1486 (GCVE-0-2024-1486)
Vulnerability from cvelistv5 – Published: 2024-05-14 15:10 – Updated: 2024-08-16 18:15
VLAI?
Summary
Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices
Severity ?
7.4 (High)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GE HealthCare | Venue |
Affected:
R1
Affected: R2 Affected: R3 , ≤ R3.3 (custom) Affected: R4 , ≤ R4.2 (custom) |
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
Credits
Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:40:21.121Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://securityupdate.gehealthcare.com/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "venue_firmware",
"vendor": "gehealthcare",
"versions": [
{
"status": "affected",
"version": "R1"
},
{
"status": "affected",
"version": "R2"
},
{
"lessThanOrEqual": "R3.3",
"status": "affected",
"version": "R3",
"versionType": "custom"
},
{
"lessThanOrEqual": "R4.2",
"status": "affected",
"version": "R4",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "venue_go_firmware",
"vendor": "gehealthcare",
"versions": [
{
"status": "affected",
"version": "R2"
},
{
"lessThanOrEqual": "R3.3",
"status": "affected",
"version": "R3",
"versionType": "custom"
},
{
"lessThanOrEqual": "R4.2",
"status": "affected",
"version": "R4",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "venue_fit_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThanOrEqual": "R3.3",
"status": "affected",
"version": "R3",
"versionType": "custom"
},
{
"lessThanOrEqual": "R4.2",
"status": "affected",
"version": "R4",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "logiq_e_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThanOrEqual": "R9.1.4",
"status": "affected",
"version": "R7",
"versionType": "custom"
},
{
"lessThanOrEqual": "R10.1.3",
"status": "affected",
"version": "R8",
"versionType": "custom"
},
{
"lessThanOrEqual": "R11.0.2",
"status": "affected",
"version": "R9",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "logiq_he_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThanOrEqual": "R9.3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "vivid_e_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "E95",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "E90",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "E80",
"versionType": "custom"
},
{
"lessThanOrEqual": "113.2",
"status": "affected",
"version": "E9 113.2",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:vivid_s_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "vivid_s_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "70N",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "60N",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "vivid_t_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "T8",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "T9",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "vivid_iq_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:invenia_abus_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "invenia_abus_firmware",
"vendor": "gehealthcare",
"versions": [
{
"status": "affected",
"version": "1.2.3"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:invenia_abus_2.0_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "invenia_abus_2.0_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThan": "2.2.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-1486",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T14:08:59.014421Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-16T18:15:02.675Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Venue",
"vendor": "GE HealthCare",
"versions": [
{
"status": "affected",
"version": "R1"
},
{
"status": "affected",
"version": "R2"
},
{
"lessThanOrEqual": "R3.3",
"status": "affected",
"version": "R3",
"versionType": "custom"
},
{
"lessThanOrEqual": "R4.2",
"status": "affected",
"version": "R4",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Venue Go",
"vendor": "GE HealthCare",
"versions": [
{
"status": "affected",
"version": "R2"
},
{
"lessThanOrEqual": "R3.3",
"status": "affected",
"version": "R3",
"versionType": "custom"
},
{
"lessThanOrEqual": "R4.2",
"status": "affected",
"version": "R4",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Venue Fit",
"vendor": "GE HealthCare",
"versions": [
{
"lessThanOrEqual": "R3.3",
"status": "affected",
"version": "R3",
"versionType": "custom"
},
{
"lessThanOrEqual": "R4.2",
"status": "affected",
"version": "R4",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "LOGIQ e",
"vendor": "GE HealthCare",
"versions": [
{
"lessThanOrEqual": "R9.1.4",
"status": "affected",
"version": "R7",
"versionType": "custom"
},
{
"lessThanOrEqual": "R10.1.3",
"status": "affected",
"version": "R8",
"versionType": "custom"
},
{
"lessThanOrEqual": "R11.0.2",
"status": "affected",
"version": "R9",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "LOGIQ He",
"vendor": "GE HealthCare",
"versions": [
{
"lessThanOrEqual": "R9.3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Vivid E",
"vendor": "GE HealthCare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "E95",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "E90",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "E80",
"versionType": "custom"
},
{
"lessThanOrEqual": "113.2",
"status": "affected",
"version": "E9 113.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Vivid S",
"vendor": "GE HealthCare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "70N",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "60N",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Vivid T",
"vendor": "GE HealthCare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "T8",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "T9",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Vivid iq",
"vendor": "GE HealthCare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Invenia ABUS",
"vendor": "GE HealthCare",
"versions": [
{
"status": "affected",
"version": "1.2.3"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Invenia ABUS 2.0",
"vendor": "GE HealthCare",
"versions": [
{
"lessThan": "2.2.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices"
}
],
"value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices"
}
],
"impacts": [
{
"capecId": "CAPEC-1",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-14T15:10:22.262Z",
"orgId": "171caf72-b841-4e04-a68e-93493aff2b94",
"shortName": "GEHC"
},
"references": [
{
"url": "https://securityupdate.gehealthcare.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94",
"assignerShortName": "GEHC",
"cveId": "CVE-2024-1486",
"datePublished": "2024-05-14T15:10:22.262Z",
"dateReserved": "2024-02-13T22:34:57.386Z",
"dateUpdated": "2024-08-16T18:15:02.675Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-1486 (GCVE-0-2024-1486)
Vulnerability from nvd – Published: 2024-05-14 15:10 – Updated: 2024-08-16 18:15
VLAI?
Summary
Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices
Severity ?
7.4 (High)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GE HealthCare | Venue |
Affected:
R1
Affected: R2 Affected: R3 , ≤ R3.3 (custom) Affected: R4 , ≤ R4.2 (custom) |
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
Credits
Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:40:21.121Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://securityupdate.gehealthcare.com/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "venue_firmware",
"vendor": "gehealthcare",
"versions": [
{
"status": "affected",
"version": "R1"
},
{
"status": "affected",
"version": "R2"
},
{
"lessThanOrEqual": "R3.3",
"status": "affected",
"version": "R3",
"versionType": "custom"
},
{
"lessThanOrEqual": "R4.2",
"status": "affected",
"version": "R4",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "venue_go_firmware",
"vendor": "gehealthcare",
"versions": [
{
"status": "affected",
"version": "R2"
},
{
"lessThanOrEqual": "R3.3",
"status": "affected",
"version": "R3",
"versionType": "custom"
},
{
"lessThanOrEqual": "R4.2",
"status": "affected",
"version": "R4",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "venue_fit_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThanOrEqual": "R3.3",
"status": "affected",
"version": "R3",
"versionType": "custom"
},
{
"lessThanOrEqual": "R4.2",
"status": "affected",
"version": "R4",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "logiq_e_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThanOrEqual": "R9.1.4",
"status": "affected",
"version": "R7",
"versionType": "custom"
},
{
"lessThanOrEqual": "R10.1.3",
"status": "affected",
"version": "R8",
"versionType": "custom"
},
{
"lessThanOrEqual": "R11.0.2",
"status": "affected",
"version": "R9",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "logiq_he_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThanOrEqual": "R9.3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "vivid_e_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "E95",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "E90",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "E80",
"versionType": "custom"
},
{
"lessThanOrEqual": "113.2",
"status": "affected",
"version": "E9 113.2",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:vivid_s_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "vivid_s_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "70N",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "60N",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "vivid_t_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "T8",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "T9",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "vivid_iq_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:invenia_abus_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "invenia_abus_firmware",
"vendor": "gehealthcare",
"versions": [
{
"status": "affected",
"version": "1.2.3"
}
]
},
{
"cpes": [
"cpe:2.3:o:gehealthcare:invenia_abus_2.0_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "invenia_abus_2.0_firmware",
"vendor": "gehealthcare",
"versions": [
{
"lessThan": "2.2.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-1486",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T14:08:59.014421Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-16T18:15:02.675Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Venue",
"vendor": "GE HealthCare",
"versions": [
{
"status": "affected",
"version": "R1"
},
{
"status": "affected",
"version": "R2"
},
{
"lessThanOrEqual": "R3.3",
"status": "affected",
"version": "R3",
"versionType": "custom"
},
{
"lessThanOrEqual": "R4.2",
"status": "affected",
"version": "R4",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Venue Go",
"vendor": "GE HealthCare",
"versions": [
{
"status": "affected",
"version": "R2"
},
{
"lessThanOrEqual": "R3.3",
"status": "affected",
"version": "R3",
"versionType": "custom"
},
{
"lessThanOrEqual": "R4.2",
"status": "affected",
"version": "R4",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Venue Fit",
"vendor": "GE HealthCare",
"versions": [
{
"lessThanOrEqual": "R3.3",
"status": "affected",
"version": "R3",
"versionType": "custom"
},
{
"lessThanOrEqual": "R4.2",
"status": "affected",
"version": "R4",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "LOGIQ e",
"vendor": "GE HealthCare",
"versions": [
{
"lessThanOrEqual": "R9.1.4",
"status": "affected",
"version": "R7",
"versionType": "custom"
},
{
"lessThanOrEqual": "R10.1.3",
"status": "affected",
"version": "R8",
"versionType": "custom"
},
{
"lessThanOrEqual": "R11.0.2",
"status": "affected",
"version": "R9",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "LOGIQ He",
"vendor": "GE HealthCare",
"versions": [
{
"lessThanOrEqual": "R9.3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Vivid E",
"vendor": "GE HealthCare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "E95",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "E90",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "E80",
"versionType": "custom"
},
{
"lessThanOrEqual": "113.2",
"status": "affected",
"version": "E9 113.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Vivid S",
"vendor": "GE HealthCare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "70N",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "60N",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Vivid T",
"vendor": "GE HealthCare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "T8",
"versionType": "custom"
},
{
"lessThan": "206",
"status": "affected",
"version": "T9",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Vivid iq",
"vendor": "GE HealthCare",
"versions": [
{
"lessThan": "206",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Invenia ABUS",
"vendor": "GE HealthCare",
"versions": [
{
"status": "affected",
"version": "1.2.3"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Invenia ABUS 2.0",
"vendor": "GE HealthCare",
"versions": [
{
"lessThan": "2.2.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices"
}
],
"value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices"
}
],
"impacts": [
{
"capecId": "CAPEC-1",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-14T15:10:22.262Z",
"orgId": "171caf72-b841-4e04-a68e-93493aff2b94",
"shortName": "GEHC"
},
"references": [
{
"url": "https://securityupdate.gehealthcare.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94",
"assignerShortName": "GEHC",
"cveId": "CVE-2024-1486",
"datePublished": "2024-05-14T15:10:22.262Z",
"dateReserved": "2024-02-13T22:34:57.386Z",
"dateUpdated": "2024-08-16T18:15:02.675Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}