Search criteria
8 vulnerabilities found for Iridium Certus 700 by Intellian Technologies
CVE-2025-41380 (GCVE-0-2025-41380)
Vulnerability from cvelistv5 – Published: 2025-05-23 12:41 – Updated: 2025-05-23 15:02
VLAI?
Title
Injection vulnerability in Iridium Certus 700
Summary
Iridium Certus 700 version 1.0.1 has an embedded credentials vulnerability in the code. This vulnerability allows a local user to retrieve the SSH hash string.
Severity ?
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Intellian Technologies | Iridium Certus 700 |
Affected:
1.0.1
|
Credits
Gabriel González García
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41380",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-23T15:01:46.290614Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-23T15:02:02.156Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iridium Certus 700",
"vendor": "Intellian Technologies",
"versions": [
{
"status": "affected",
"version": "1.0.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gabriel Gonz\u00e1lez Garc\u00eda"
}
],
"datePublic": "2025-05-23T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Iridium Certus 700 version 1.0.1 has an embedded credentials vulnerability in the code. This vulnerability allows a local user to retrieve the SSH hash string."
}
],
"value": "Iridium Certus 700 version 1.0.1 has an embedded credentials vulnerability in the code. This vulnerability allows a local user to retrieve the SSH hash string."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:N/SC:L/SI:H/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-23T12:41:58.459Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-intellian-technologies-iridium-certus"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been resolved by the Intellian Technologies team in the Q2 2025 release."
}
],
"value": "The vulnerability has been resolved by the Intellian Technologies team in the Q2 2025 release."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Injection vulnerability in Iridium Certus 700",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-41380",
"datePublished": "2025-05-23T12:41:58.459Z",
"dateReserved": "2025-04-16T09:57:07.297Z",
"dateUpdated": "2025-05-23T15:02:02.156Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41379 (GCVE-0-2025-41379)
Vulnerability from cvelistv5 – Published: 2025-05-23 12:41 – Updated: 2025-05-23 15:04
VLAI?
Title
Injection vulnerability in Iridium Certus 700
Summary
The Intellian C700 web panel allows you to add firewall rules. Each of these rules has an associated ID, but there is a problem when adding a new rule, the ID used to create the database entry may be different from the JSON ID. If the rule needs to be deleted later, the system will use the JSON ID and therefore fail. This can be exploited by an attacker to create rules that cannot be deleted unless the device is reset to factory defaults.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Intellian Technologies | Iridium Certus 700 |
Affected:
1.0.1
|
Credits
Gabriel González García
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41379",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-23T15:03:58.549277Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-23T15:04:14.233Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iridium Certus 700",
"vendor": "Intellian Technologies",
"versions": [
{
"status": "affected",
"version": "1.0.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gabriel Gonz\u00e1lez Garc\u00eda"
}
],
"datePublic": "2025-05-23T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Intellian C700 web panel allows you to add firewall rules. Each of these rules has an associated ID, but there is a problem when adding a new rule, the ID used to create the database entry may be different from the JSON ID. If the rule needs to be deleted later, the system will use the JSON ID and therefore fail. This can be exploited by an attacker to create rules that cannot be deleted unless the device is reset to factory defaults."
}
],
"value": "The Intellian C700 web panel allows you to add firewall rules. Each of these rules has an associated ID, but there is a problem when adding a new rule, the ID used to create the database entry may be different from the JSON ID. If the rule needs to be deleted later, the system will use the JSON ID and therefore fail. This can be exploited by an attacker to create rules that cannot be deleted unless the device is reset to factory defaults."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:N/SC:N/SI:H/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-23T12:41:09.682Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-intellian-technologies-iridium-certus"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been resolved by the Intellian Technologies team in the Q2 2025 release."
}
],
"value": "The vulnerability has been resolved by the Intellian Technologies team in the Q2 2025 release."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Injection vulnerability in Iridium Certus 700",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-41379",
"datePublished": "2025-05-23T12:41:09.682Z",
"dateReserved": "2025-04-16T09:57:07.297Z",
"dateUpdated": "2025-05-23T15:04:14.233Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41378 (GCVE-0-2025-41378)
Vulnerability from cvelistv5 – Published: 2025-05-23 12:40 – Updated: 2025-05-27 14:39
VLAI?
Title
Injection vulnerability in Iridium Certus 700
Summary
The SSID field is not parsed correctly and can be used to inject commands into the hostpad.conf file. This can be exploited by an attacker to extend his knowledge of the system and compromise other devices. The information is filtered by the logs function of the web panel.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Intellian Technologies | Iridium Certus 700 |
Affected:
1.0.1
|
Credits
Gabriel González García
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41378",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-27T14:39:09.203958Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-27T14:39:15.642Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iridium Certus 700",
"vendor": "Intellian Technologies",
"versions": [
{
"status": "affected",
"version": "1.0.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gabriel Gonz\u00e1lez Garc\u00eda"
}
],
"datePublic": "2025-05-23T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The SSID field is not parsed correctly and can be used to inject commands into the hostpad.conf file. This can be exploited by an attacker to extend his knowledge of the system and compromise other devices. The information is filtered by the logs function of the web panel."
}
],
"value": "The SSID field is not parsed correctly and can be used to inject commands into the hostpad.conf file. This can be exploited by an attacker to extend his knowledge of the system and compromise other devices. The information is filtered by the logs function of the web panel."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-23T12:40:14.121Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-intellian-technologies-iridium-certus"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been resolved by the Intellian Technologies team in the Q2 2025 release."
}
],
"value": "The vulnerability has been resolved by the Intellian Technologies team in the Q2 2025 release."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Injection vulnerability in Iridium Certus 700",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-41378",
"datePublished": "2025-05-23T12:40:14.121Z",
"dateReserved": "2025-04-16T09:57:07.297Z",
"dateUpdated": "2025-05-27T14:39:15.642Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41377 (GCVE-0-2025-41377)
Vulnerability from cvelistv5 – Published: 2025-05-23 12:37 – Updated: 2025-08-01 12:30
VLAI?
Title
SQL injection vulnerability in Gandia Integra Total
Summary
A SQL injection vulnerability has been found in Gandia Integra Total of TESI from version 2.1.2217.3 to v4.4.2236.1. The vulnerability allows an authenticated attacker to retrieve, create, update and delete databases through the 'idestudio' parameter in /encuestas/integraweb[_v4]/integra/html/view/consultacuotasred.php.
Severity ?
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| TESI | Gandia Integra Total |
Affected:
2.1.2217.3 , < 4.4.2236.1
(custom)
|
Credits
David Utón Amaya (m3n0sd0n4ld)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41377",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-27T14:39:28.456565Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-27T14:39:36.816Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Gandia Integra Total",
"vendor": "TESI",
"versions": [
{
"lessThan": "4.4.2236.1",
"status": "affected",
"version": "2.1.2217.3",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "David Ut\u00f3n Amaya (m3n0sd0n4ld)"
}
],
"datePublic": "2025-07-31T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A SQL injection vulnerability has been found in Gandia Integra Total of TESI from version 2.1.2217.3 to v4.4.2236.1. The vulnerability allows an authenticated attacker to retrieve, create, update and delete databases through the \u0027idestudio\u0027 parameter in /encuestas/integraweb[_v4]/integra/html/view/consultacuotasred.php."
}
],
"value": "A SQL injection vulnerability has been found in Gandia Integra Total of TESI from version 2.1.2217.3 to v4.4.2236.1. The vulnerability allows an authenticated attacker to retrieve, create, update and delete databases through the \u0027idestudio\u0027 parameter in /encuestas/integraweb[_v4]/integra/html/view/consultacuotasred.php."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-01T12:30:09.665Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-gandia-integra-total-tesi"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been fixed by the TESI team in version 4.4.2431.5."
}
],
"value": "The vulnerability has been fixed by the TESI team in version 4.4.2431.5."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "SQL injection vulnerability in Gandia Integra Total",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-41377",
"datePublished": "2025-05-23T12:37:48.645Z",
"dateReserved": "2025-04-16T09:57:07.297Z",
"dateUpdated": "2025-08-01T12:30:09.665Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41380 (GCVE-0-2025-41380)
Vulnerability from nvd – Published: 2025-05-23 12:41 – Updated: 2025-05-23 15:02
VLAI?
Title
Injection vulnerability in Iridium Certus 700
Summary
Iridium Certus 700 version 1.0.1 has an embedded credentials vulnerability in the code. This vulnerability allows a local user to retrieve the SSH hash string.
Severity ?
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Intellian Technologies | Iridium Certus 700 |
Affected:
1.0.1
|
Credits
Gabriel González García
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41380",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-23T15:01:46.290614Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-23T15:02:02.156Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iridium Certus 700",
"vendor": "Intellian Technologies",
"versions": [
{
"status": "affected",
"version": "1.0.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gabriel Gonz\u00e1lez Garc\u00eda"
}
],
"datePublic": "2025-05-23T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Iridium Certus 700 version 1.0.1 has an embedded credentials vulnerability in the code. This vulnerability allows a local user to retrieve the SSH hash string."
}
],
"value": "Iridium Certus 700 version 1.0.1 has an embedded credentials vulnerability in the code. This vulnerability allows a local user to retrieve the SSH hash string."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:N/SC:L/SI:H/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-23T12:41:58.459Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-intellian-technologies-iridium-certus"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been resolved by the Intellian Technologies team in the Q2 2025 release."
}
],
"value": "The vulnerability has been resolved by the Intellian Technologies team in the Q2 2025 release."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Injection vulnerability in Iridium Certus 700",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-41380",
"datePublished": "2025-05-23T12:41:58.459Z",
"dateReserved": "2025-04-16T09:57:07.297Z",
"dateUpdated": "2025-05-23T15:02:02.156Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41379 (GCVE-0-2025-41379)
Vulnerability from nvd – Published: 2025-05-23 12:41 – Updated: 2025-05-23 15:04
VLAI?
Title
Injection vulnerability in Iridium Certus 700
Summary
The Intellian C700 web panel allows you to add firewall rules. Each of these rules has an associated ID, but there is a problem when adding a new rule, the ID used to create the database entry may be different from the JSON ID. If the rule needs to be deleted later, the system will use the JSON ID and therefore fail. This can be exploited by an attacker to create rules that cannot be deleted unless the device is reset to factory defaults.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Intellian Technologies | Iridium Certus 700 |
Affected:
1.0.1
|
Credits
Gabriel González García
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41379",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-23T15:03:58.549277Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-23T15:04:14.233Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iridium Certus 700",
"vendor": "Intellian Technologies",
"versions": [
{
"status": "affected",
"version": "1.0.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gabriel Gonz\u00e1lez Garc\u00eda"
}
],
"datePublic": "2025-05-23T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Intellian C700 web panel allows you to add firewall rules. Each of these rules has an associated ID, but there is a problem when adding a new rule, the ID used to create the database entry may be different from the JSON ID. If the rule needs to be deleted later, the system will use the JSON ID and therefore fail. This can be exploited by an attacker to create rules that cannot be deleted unless the device is reset to factory defaults."
}
],
"value": "The Intellian C700 web panel allows you to add firewall rules. Each of these rules has an associated ID, but there is a problem when adding a new rule, the ID used to create the database entry may be different from the JSON ID. If the rule needs to be deleted later, the system will use the JSON ID and therefore fail. This can be exploited by an attacker to create rules that cannot be deleted unless the device is reset to factory defaults."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:N/SC:N/SI:H/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-23T12:41:09.682Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-intellian-technologies-iridium-certus"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been resolved by the Intellian Technologies team in the Q2 2025 release."
}
],
"value": "The vulnerability has been resolved by the Intellian Technologies team in the Q2 2025 release."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Injection vulnerability in Iridium Certus 700",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-41379",
"datePublished": "2025-05-23T12:41:09.682Z",
"dateReserved": "2025-04-16T09:57:07.297Z",
"dateUpdated": "2025-05-23T15:04:14.233Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41378 (GCVE-0-2025-41378)
Vulnerability from nvd – Published: 2025-05-23 12:40 – Updated: 2025-05-27 14:39
VLAI?
Title
Injection vulnerability in Iridium Certus 700
Summary
The SSID field is not parsed correctly and can be used to inject commands into the hostpad.conf file. This can be exploited by an attacker to extend his knowledge of the system and compromise other devices. The information is filtered by the logs function of the web panel.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Intellian Technologies | Iridium Certus 700 |
Affected:
1.0.1
|
Credits
Gabriel González García
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41378",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-27T14:39:09.203958Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-27T14:39:15.642Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iridium Certus 700",
"vendor": "Intellian Technologies",
"versions": [
{
"status": "affected",
"version": "1.0.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gabriel Gonz\u00e1lez Garc\u00eda"
}
],
"datePublic": "2025-05-23T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The SSID field is not parsed correctly and can be used to inject commands into the hostpad.conf file. This can be exploited by an attacker to extend his knowledge of the system and compromise other devices. The information is filtered by the logs function of the web panel."
}
],
"value": "The SSID field is not parsed correctly and can be used to inject commands into the hostpad.conf file. This can be exploited by an attacker to extend his knowledge of the system and compromise other devices. The information is filtered by the logs function of the web panel."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-23T12:40:14.121Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-intellian-technologies-iridium-certus"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been resolved by the Intellian Technologies team in the Q2 2025 release."
}
],
"value": "The vulnerability has been resolved by the Intellian Technologies team in the Q2 2025 release."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Injection vulnerability in Iridium Certus 700",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-41378",
"datePublished": "2025-05-23T12:40:14.121Z",
"dateReserved": "2025-04-16T09:57:07.297Z",
"dateUpdated": "2025-05-27T14:39:15.642Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41377 (GCVE-0-2025-41377)
Vulnerability from nvd – Published: 2025-05-23 12:37 – Updated: 2025-08-01 12:30
VLAI?
Title
SQL injection vulnerability in Gandia Integra Total
Summary
A SQL injection vulnerability has been found in Gandia Integra Total of TESI from version 2.1.2217.3 to v4.4.2236.1. The vulnerability allows an authenticated attacker to retrieve, create, update and delete databases through the 'idestudio' parameter in /encuestas/integraweb[_v4]/integra/html/view/consultacuotasred.php.
Severity ?
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| TESI | Gandia Integra Total |
Affected:
2.1.2217.3 , < 4.4.2236.1
(custom)
|
Credits
David Utón Amaya (m3n0sd0n4ld)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41377",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-27T14:39:28.456565Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-27T14:39:36.816Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Gandia Integra Total",
"vendor": "TESI",
"versions": [
{
"lessThan": "4.4.2236.1",
"status": "affected",
"version": "2.1.2217.3",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "David Ut\u00f3n Amaya (m3n0sd0n4ld)"
}
],
"datePublic": "2025-07-31T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A SQL injection vulnerability has been found in Gandia Integra Total of TESI from version 2.1.2217.3 to v4.4.2236.1. The vulnerability allows an authenticated attacker to retrieve, create, update and delete databases through the \u0027idestudio\u0027 parameter in /encuestas/integraweb[_v4]/integra/html/view/consultacuotasred.php."
}
],
"value": "A SQL injection vulnerability has been found in Gandia Integra Total of TESI from version 2.1.2217.3 to v4.4.2236.1. The vulnerability allows an authenticated attacker to retrieve, create, update and delete databases through the \u0027idestudio\u0027 parameter in /encuestas/integraweb[_v4]/integra/html/view/consultacuotasred.php."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-01T12:30:09.665Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-gandia-integra-total-tesi"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been fixed by the TESI team in version 4.4.2431.5."
}
],
"value": "The vulnerability has been fixed by the TESI team in version 4.4.2431.5."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "SQL injection vulnerability in Gandia Integra Total",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-41377",
"datePublished": "2025-05-23T12:37:48.645Z",
"dateReserved": "2025-04-16T09:57:07.297Z",
"dateUpdated": "2025-08-01T12:30:09.665Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",