Search criteria

8 vulnerabilities found for Mendix Runtime V9 by Siemens

CVE-2025-30280 (GCVE-0-2025-30280)

Vulnerability from cvelistv5 – Published: 2025-04-08 08:22 – Updated: 2025-06-10 15:17
VLAI?
Summary
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.21.0), Mendix Runtime V10.12 (All versions < V10.12.16), Mendix Runtime V10.18 (All versions < V10.18.5), Mendix Runtime V10.6 (All versions < V10.6.22), Mendix Runtime V8 (All versions < V8.18.35), Mendix Runtime V9 (All versions < V9.24.34). Affected applications allow for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application.
CWE
  • CWE-204 - Observable Response Discrepancy
Assigner
Impacted products
Vendor Product Version
Siemens Mendix Runtime V10 Affected: 0 , < V10.21.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30280",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T13:10:20.606472Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T13:12:03.334Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.21.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.12.16",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.18.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.6",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.6.22",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.18.35",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.24.34",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V10 (All versions \u003c V10.21.0), Mendix Runtime V10.12 (All versions \u003c V10.12.16), Mendix Runtime V10.18 (All versions \u003c V10.18.5), Mendix Runtime V10.6 (All versions \u003c V10.6.22), Mendix Runtime V8 (All versions \u003c V8.18.35), Mendix Runtime V9 (All versions \u003c V9.24.34). Affected applications allow for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-204",
              "description": "CWE-204: Observable Response Discrepancy",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-10T15:17:23.562Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-874353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-30280",
    "datePublished": "2025-04-08T08:22:31.167Z",
    "dateReserved": "2025-03-20T11:01:33.481Z",
    "dateUpdated": "2025-06-10T15:17:23.562Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-50313 (GCVE-0-2024-50313)

Vulnerability from cvelistv5 – Published: 2024-11-12 12:49 – Updated: 2025-08-27 21:33
VLAI?
Summary
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.16.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions < V10.12.7 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions < V10.6.15 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions < V9.24.29 only if the basic authentication mechanism is used by the application). The basic authentication implementation of affected applications contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures.
CWE
  • CWE-362 - Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-50313",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T14:16:20.945053Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T21:33:05.238Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.16.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.12.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.6",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.6.15",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.24.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V10 (All versions \u003c V10.16.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions \u003c V10.12.7 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions \u003c V10.6.15 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions \u003c V9.24.29 only if the basic authentication mechanism is used by the application). The basic authentication implementation of affected applications contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-362",
              "description": "CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:16:45.329Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-914892.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-50313",
    "datePublished": "2024-11-12T12:49:54.803Z",
    "dateReserved": "2024-10-22T15:35:51.132Z",
    "dateUpdated": "2025-08-27T21:33:05.238Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-49069 (GCVE-0-2023-49069)

Vulnerability from cvelistv5 – Published: 2024-09-10 09:36 – Updated: 2025-01-14 10:29
VLAI?
Summary
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.17.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions < V10.12.11 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions < V10.6.19 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions < V8.18.33 only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions < V9.24.31 only if the basic authentication mechanism is used by the application). The authentication mechanism of affected applications contains an observable response discrepancy vulnerability when validating usernames. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames.
CWE
  • CWE-204 - Observable Response Discrepancy
Assigner
Impacted products
Vendor Product Version
Siemens Mendix Runtime V10 Affected: 0 , < V10.17.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:mendix:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mendix",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "9.24.26",
                "status": "affected",
                "version": "8.0",
                "versionType": "custom"
              },
              {
                "lessThan": "10.6.12",
                "status": "affected",
                "version": "10.0",
                "versionType": "custom"
              },
              {
                "lessThan": "10.12.2",
                "status": "affected",
                "version": "10.7",
                "versionType": "custom"
              },
              {
                "lessThan": "10.14.0",
                "status": "affected",
                "version": "10.13",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-49069",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-10T18:35:09.531765Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-10T18:39:46.492Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.17.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.12.11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.6",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.6.19",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.18.33",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.24.31",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V10 (All versions \u003c V10.17.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions \u003c V10.12.11 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions \u003c V10.6.19 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions \u003c V8.18.33 only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions \u003c V9.24.31 only if the basic authentication mechanism is used by the application). The authentication mechanism of affected applications contains an observable response discrepancy vulnerability when validating usernames. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-204",
              "description": "CWE-204: Observable Response Discrepancy",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T10:29:57.002Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-097435.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-49069",
    "datePublished": "2024-09-10T09:36:25.399Z",
    "dateReserved": "2023-11-21T11:51:19.666Z",
    "dateUpdated": "2025-01-14T10:29:57.002Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-24309 (GCVE-0-2022-24309)

Vulnerability from cvelistv5 – Published: 2022-03-08 11:31 – Updated: 2024-10-08 08:39
VLAI?
Summary
A vulnerability has been identified in Mendix Runtime V7 (All versions < V7.23.29), Mendix Runtime V8 (All versions < V8.18.16), Mendix Runtime V9 (All versions < V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data.
CWE
  • CWE-284 - Improper Access Control
Assigner
Impacted products
Vendor Product Version
Siemens Mendix Runtime V7 Affected: 0 , < V7.23.29 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:07:02.516Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.23.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.18.16",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V7 (All versions \u003c V7.23.29), Mendix Runtime V8 (All versions \u003c V8.18.16), Mendix Runtime V9 (All versions \u003c V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:51.939Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-24309",
    "datePublished": "2022-03-08T11:31:29",
    "dateReserved": "2022-02-02T00:00:00",
    "dateUpdated": "2024-10-08T08:39:51.939Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-30280 (GCVE-0-2025-30280)

Vulnerability from nvd – Published: 2025-04-08 08:22 – Updated: 2025-06-10 15:17
VLAI?
Summary
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.21.0), Mendix Runtime V10.12 (All versions < V10.12.16), Mendix Runtime V10.18 (All versions < V10.18.5), Mendix Runtime V10.6 (All versions < V10.6.22), Mendix Runtime V8 (All versions < V8.18.35), Mendix Runtime V9 (All versions < V9.24.34). Affected applications allow for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application.
CWE
  • CWE-204 - Observable Response Discrepancy
Assigner
Impacted products
Vendor Product Version
Siemens Mendix Runtime V10 Affected: 0 , < V10.21.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30280",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T13:10:20.606472Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T13:12:03.334Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.21.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.12.16",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.18.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.6",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.6.22",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.18.35",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.24.34",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V10 (All versions \u003c V10.21.0), Mendix Runtime V10.12 (All versions \u003c V10.12.16), Mendix Runtime V10.18 (All versions \u003c V10.18.5), Mendix Runtime V10.6 (All versions \u003c V10.6.22), Mendix Runtime V8 (All versions \u003c V8.18.35), Mendix Runtime V9 (All versions \u003c V9.24.34). Affected applications allow for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-204",
              "description": "CWE-204: Observable Response Discrepancy",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-10T15:17:23.562Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-874353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-30280",
    "datePublished": "2025-04-08T08:22:31.167Z",
    "dateReserved": "2025-03-20T11:01:33.481Z",
    "dateUpdated": "2025-06-10T15:17:23.562Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-50313 (GCVE-0-2024-50313)

Vulnerability from nvd – Published: 2024-11-12 12:49 – Updated: 2025-08-27 21:33
VLAI?
Summary
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.16.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions < V10.12.7 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions < V10.6.15 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions < V9.24.29 only if the basic authentication mechanism is used by the application). The basic authentication implementation of affected applications contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures.
CWE
  • CWE-362 - Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-50313",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T14:16:20.945053Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T21:33:05.238Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.16.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.12.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.6",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.6.15",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.24.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V10 (All versions \u003c V10.16.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions \u003c V10.12.7 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions \u003c V10.6.15 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions \u003c V9.24.29 only if the basic authentication mechanism is used by the application). The basic authentication implementation of affected applications contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-362",
              "description": "CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:16:45.329Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-914892.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-50313",
    "datePublished": "2024-11-12T12:49:54.803Z",
    "dateReserved": "2024-10-22T15:35:51.132Z",
    "dateUpdated": "2025-08-27T21:33:05.238Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-49069 (GCVE-0-2023-49069)

Vulnerability from nvd – Published: 2024-09-10 09:36 – Updated: 2025-01-14 10:29
VLAI?
Summary
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.17.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions < V10.12.11 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions < V10.6.19 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions < V8.18.33 only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions < V9.24.31 only if the basic authentication mechanism is used by the application). The authentication mechanism of affected applications contains an observable response discrepancy vulnerability when validating usernames. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames.
CWE
  • CWE-204 - Observable Response Discrepancy
Assigner
Impacted products
Vendor Product Version
Siemens Mendix Runtime V10 Affected: 0 , < V10.17.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:mendix:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mendix",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "9.24.26",
                "status": "affected",
                "version": "8.0",
                "versionType": "custom"
              },
              {
                "lessThan": "10.6.12",
                "status": "affected",
                "version": "10.0",
                "versionType": "custom"
              },
              {
                "lessThan": "10.12.2",
                "status": "affected",
                "version": "10.7",
                "versionType": "custom"
              },
              {
                "lessThan": "10.14.0",
                "status": "affected",
                "version": "10.13",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-49069",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-10T18:35:09.531765Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-10T18:39:46.492Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.17.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.12.11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.6",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.6.19",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.18.33",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.24.31",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V10 (All versions \u003c V10.17.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions \u003c V10.12.11 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions \u003c V10.6.19 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions \u003c V8.18.33 only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions \u003c V9.24.31 only if the basic authentication mechanism is used by the application). The authentication mechanism of affected applications contains an observable response discrepancy vulnerability when validating usernames. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-204",
              "description": "CWE-204: Observable Response Discrepancy",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T10:29:57.002Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-097435.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-49069",
    "datePublished": "2024-09-10T09:36:25.399Z",
    "dateReserved": "2023-11-21T11:51:19.666Z",
    "dateUpdated": "2025-01-14T10:29:57.002Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-24309 (GCVE-0-2022-24309)

Vulnerability from nvd – Published: 2022-03-08 11:31 – Updated: 2024-10-08 08:39
VLAI?
Summary
A vulnerability has been identified in Mendix Runtime V7 (All versions < V7.23.29), Mendix Runtime V8 (All versions < V8.18.16), Mendix Runtime V9 (All versions < V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data.
CWE
  • CWE-284 - Improper Access Control
Assigner
Impacted products
Vendor Product Version
Siemens Mendix Runtime V7 Affected: 0 , < V7.23.29 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:07:02.516Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.23.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.18.16",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V7 (All versions \u003c V7.23.29), Mendix Runtime V8 (All versions \u003c V8.18.16), Mendix Runtime V9 (All versions \u003c V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:51.939Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-24309",
    "datePublished": "2022-03-08T11:31:29",
    "dateReserved": "2022-02-02T00:00:00",
    "dateUpdated": "2024-10-08T08:39:51.939Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}