All the vulnerabilites related to Siemens - Mendix SAML (Mendix 9 latest compatible, New Track)
cve-2023-25957
Vulnerability from cvelistv5
Published
2023-03-14 09:31
Modified
2024-08-02 11:39
Summary
A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions >= V1.16.4 < V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions >= V2.2.0 < V2.3.0), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions >= V3.1.9 < V3.3.1), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions >= V3.1.8 < V3.3.0), Mendix SAML (Mendix 9.6 compatible, New Track) (All versions >= V3.1.9 < V3.2.7), Mendix SAML (Mendix 9.6 compatible, Upgrade Track) (All versions >= V3.1.8 < V3.2.6). The affected versions of the module insufficiently verify the SAML assertions. This could allow unauthenticated remote attackers to bypass authentication and get access to the application. For compatibility reasons, fix versions still contain this issue, but only when the recommended, default configuration option `'Use Encryption'` is disabled.
Impacted products
Vendor Product Version
Siemens Mendix SAML (Mendix 8 compatible) Version: All versions >= V2.2.0 < V2.3.0
Siemens Mendix SAML (Mendix 9 latest compatible, New Track) Version: All versions >= V3.1.9 < V3.3.1
Siemens Mendix SAML (Mendix 9 latest compatible, Upgrade Track) Version: All versions >= V3.1.8 < V3.3.0
Siemens Mendix SAML (Mendix 9.6 compatible, New Track) Version: All versions >= V3.1.9 < V3.2.7
Siemens Mendix SAML (Mendix 9.6 compatible, Upgrade Track) Version: All versions >= V3.1.8 < V3.2.6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T11:39:06.039Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-851884.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 7 compatible)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V1.16.4 \u003c V1.17.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 8 compatible)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.2.0 \u003c V2.3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 9 latest compatible, New Track)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.1.9 \u003c V3.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 9 latest compatible, Upgrade Track)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.1.8 \u003c V3.3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 9.6 compatible, New Track)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.1.9 \u003c V3.2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 9.6 compatible, Upgrade Track)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.1.8 \u003c V3.2.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions \u003e= V1.16.4 \u003c V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions \u003e= V2.2.0 \u003c V2.3.0), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions \u003e= V3.1.9 \u003c V3.3.1), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions \u003e= V3.1.8 \u003c V3.3.0), Mendix SAML (Mendix 9.6 compatible, New Track) (All versions \u003e= V3.1.9 \u003c V3.2.7), Mendix SAML (Mendix 9.6 compatible, Upgrade Track) (All versions \u003e= V3.1.8 \u003c V3.2.6). The affected versions of the module insufficiently verify the SAML assertions. This could allow unauthenticated remote attackers to bypass authentication and get access to the application.\r\n\r\nFor compatibility reasons, fix versions still contain this issue, but only when the recommended, default configuration option `\u0027Use Encryption\u0027` is disabled."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-303",
              "description": "CWE-303: Incorrect Implementation of Authentication Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:15.602Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-851884.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-25957",
    "datePublished": "2023-03-14T09:31:56.091Z",
    "dateReserved": "2023-02-17T12:29:22.279Z",
    "dateUpdated": "2024-08-02T11:39:06.039Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-29129
Vulnerability from cvelistv5
Published
2023-06-13 08:17
Modified
2024-08-02 14:00
Summary
A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.3 < V1.18.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.16.4 < V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.4.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.2.0 < V2.3.0), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions >= V3.3.1 < V3.6.1), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions >= V3.1.9 < V3.3.1), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions >= V3.3.0 < V3.6.0), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions >= V3.1.8 < V3.3.0), Mendix SAML (Mendix 9.12/9.18 compatible, New Track) (All versions >= V3.3.1 < V3.3.15), Mendix SAML (Mendix 9.12/9.18 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.14), Mendix SAML (Mendix 9.6 compatible, New Track) (All versions >= V3.1.9 < V3.2.7), Mendix SAML (Mendix 9.6 compatible, Upgrade Track) (All versions >= V3.1.8 < V3.2.6). The affected versions of the module insufficiently verify the SAML assertions. This could allow unauthenticated remote attackers to bypass authentication and get access to the application. This CVE entry describes the incomplete fix for CVE-2023-25957 in a specific non default configuration.
Impacted products
Vendor Product Version
Siemens Mendix SAML (Mendix 7 compatible) Version: All versions >= V1.16.4 < V1.17.3
Siemens Mendix SAML (Mendix 8 compatible) Version: All versions >= V2.3.0 < V2.4.0
Siemens Mendix SAML (Mendix 8 compatible) Version: All versions >= V2.2.0 < V2.3.0
Siemens Mendix SAML (Mendix 9 latest compatible, New Track) Version: All versions >= V3.3.1 < V3.6.1
Siemens Mendix SAML (Mendix 9 latest compatible, New Track) Version: All versions >= V3.1.9 < V3.3.1
Siemens Mendix SAML (Mendix 9 latest compatible, Upgrade Track) Version: All versions >= V3.3.0 < V3.6.0
Siemens Mendix SAML (Mendix 9 latest compatible, Upgrade Track) Version: All versions >= V3.1.8 < V3.3.0
Siemens Mendix SAML (Mendix 9.12/9.18 compatible, New Track) Version: All versions >= V3.3.1 < V3.3.15
Siemens Mendix SAML (Mendix 9.12/9.18 compatible, Upgrade Track) Version: All versions >= V3.3.0 < V3.3.14
Siemens Mendix SAML (Mendix 9.6 compatible, New Track) Version: All versions >= V3.1.9 < V3.2.7
Siemens Mendix SAML (Mendix 9.6 compatible, Upgrade Track) Version: All versions >= V3.1.8 < V3.2.6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:00:14.997Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-851884.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 7 compatible)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V1.17.3 \u003c V1.18.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 7 compatible)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V1.16.4 \u003c V1.17.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 8 compatible)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3.0 \u003c V2.4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 8 compatible)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.2.0 \u003c V2.3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 9 latest compatible, New Track)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.3.1 \u003c V3.6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 9 latest compatible, New Track)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.1.9 \u003c V3.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 9 latest compatible, Upgrade Track)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.3.0 \u003c V3.6.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 9 latest compatible, Upgrade Track)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.1.8 \u003c V3.3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 9.12/9.18 compatible, New Track)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.3.1 \u003c V3.3.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 9.12/9.18 compatible, Upgrade Track)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.3.0 \u003c V3.3.14"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 9.6 compatible, New Track)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.1.9 \u003c V3.2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix SAML (Mendix 9.6 compatible, Upgrade Track)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.1.8 \u003c V3.2.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions \u003e= V1.17.3 \u003c V1.18.0), Mendix SAML (Mendix 7 compatible) (All versions \u003e= V1.16.4 \u003c V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions \u003e= V2.3.0 \u003c V2.4.0), Mendix SAML (Mendix 8 compatible) (All versions \u003e= V2.2.0 \u003c V2.3.0), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions \u003e= V3.3.1 \u003c V3.6.1), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions \u003e= V3.1.9 \u003c V3.3.1), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions \u003e= V3.3.0 \u003c V3.6.0), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions \u003e= V3.1.8 \u003c V3.3.0), Mendix SAML (Mendix 9.12/9.18 compatible, New Track) (All versions \u003e= V3.3.1 \u003c V3.3.15), Mendix SAML (Mendix 9.12/9.18 compatible, Upgrade Track) (All versions \u003e= V3.3.0 \u003c V3.3.14), Mendix SAML (Mendix 9.6 compatible, New Track) (All versions \u003e= V3.1.9 \u003c V3.2.7), Mendix SAML (Mendix 9.6 compatible, Upgrade Track) (All versions \u003e= V3.1.8 \u003c V3.2.6). The affected versions of the module insufficiently verify the SAML assertions. This could allow unauthenticated remote attackers to bypass authentication and get access to the application.\r\n\r\nThis CVE entry describes the incomplete fix for CVE-2023-25957 in a specific non default configuration."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-303",
              "description": "CWE-303: Incorrect Implementation of Authentication Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:18.907Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-851884.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-29129",
    "datePublished": "2023-06-13T08:17:09.102Z",
    "dateReserved": "2023-03-31T10:54:25.290Z",
    "dateUpdated": "2024-08-02T14:00:14.997Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}