All the vulnerabilites related to Illumina - MiSeq Control Software
cve-2023-1966
Vulnerability from cvelistv5
Published
2023-04-28 18:06
Modified
2024-08-02 06:05
Summary
CVE-2023-1966
Impacted products
Vendor Product Version
Illumina MiniSeq Control Software Version: 2.0
Illumina iSeq 100 Version: All versions
Illumina MiSeq Control Software Version: 4.0 (RUO Mode)
Illumina MiSeqDx Operating Software Version: 4.0.1
Illumina NextSeq 500/550 Control Software Version: 4.0
Illumina NextSeq 550Dx Control Software Version: 4.0 (RUO Mode)
Illumina NextSeq 550Dx Operating Software Version: 1.0.0   <
Version: 1.3.3
Illumina NextSeq 1000/2000 Control Software Version: 0   <
Illumina NovaSeq 6000 Control Software Version: 0   <
Illumina NovaSeq Control Software Version: 1.8
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:05:27.096Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-117-01"
          },
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://support.illumina.com/downloads/illumina-universal-copy-service-1-0.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "iScan Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.0"
            },
            {
              "status": "affected",
              "version": "4.0.5"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MiniSeq Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "2.0 "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "iSeq 100",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MiSeq Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0 (RUO Mode)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MiSeqDx Operating Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.1 "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NextSeq 500/550 Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NextSeq 550Dx Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0 (RUO Mode)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NextSeq 550Dx Operating Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "lessThanOrEqual": "1.3.1",
              "status": "affected",
              "version": "1.0.0 ",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "1.3.3 "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NextSeq 1000/2000 Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "lessThanOrEqual": "1.4.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NovaSeq 6000 Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "lessThanOrEqual": "1.7 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NovaSeq Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "1.8"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Illumina reported these vulnerabilities to CISA. "
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Instruments with Illumina Universal Copy Service v1.x and\nv2.x contain an unnecessary privileges vulnerability. An unauthenticated\nmalicious actor could upload and execute code remotely at the operating system\nlevel, which could allow an attacker to change settings, configurations,\nsoftware, or access sensitive data on the affected product.\n\n\n\n\n\n"
            }
          ],
          "value": "Instruments with Illumina Universal Copy Service v1.x and\nv2.x contain an unnecessary privileges vulnerability. An unauthenticated\nmalicious actor could upload and execute code remotely at the operating system\nlevel, which could allow an attacker to change settings, configurations,\nsoftware, or access sensitive data on the affected product.\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-250",
              "description": "CWE-250 Execution with Unnecessary Privileges",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-28T18:06:51.431Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-117-01"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://support.illumina.com/downloads/illumina-universal-copy-service-1-0.html"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "CVE-2023-1966",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIllumina recommends using the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.illumina.com/downloads/illumina-universal-copy-service-1-0.html\"\u003eUCS Vulnerability Instructions Guide\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;based on the user\u2019s specific system configuration to mitigate the vulnerabilities. Illumina recommends users read the instructions before downloading any software. \u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nIllumina recommends using the  UCS Vulnerability Instructions Guide https://support.illumina.com/downloads/illumina-universal-copy-service-1-0.html \u00a0based on the user\u2019s specific system configuration to mitigate the vulnerabilities. Illumina recommends users read the instructions before downloading any software. \n\n\n"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-1966",
    "datePublished": "2023-04-28T18:06:51.431Z",
    "dateReserved": "2023-04-10T14:50:41.262Z",
    "dateUpdated": "2024-08-02T06:05:27.096Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-1968
Vulnerability from cvelistv5
Published
2023-04-28 18:09
Modified
2024-08-02 06:05
Severity ?
Summary
CVE-2023-1968
Impacted products
Vendor Product Version
Illumina MiniSeq Control Software Version: 2.0
Illumina iSeq 100 Version: All versions
Illumina MiSeq Control Software Version: 4.0 (RUO Mode)
Illumina MiSeqDx Operating Software Version: 4.0.1
Illumina NextSeq 500/550 Control Software Version: 4.0
Illumina NextSeq 550Dx Control Software Version: 4.0 (RUO Mode)
Illumina NextSeq 550Dx Operating Software Version: 1.0.0   <
Version: 1.3.3
Illumina NextSeq 1000/2000 Control Software Version: 0   <
Illumina NovaSeq 6000 Control Software Version: 0   <
Illumina NovaSeq Control Software Version: 1.8
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:05:27.076Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-117-01"
          },
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://support.illumina.com/downloads/illumina-universal-copy-service-1-0.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "iScan Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.0"
            },
            {
              "status": "affected",
              "version": "4.0.5"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MiniSeq Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "2.0 "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "iSeq 100",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MiSeq Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0 (RUO Mode)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MiSeqDx Operating Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.1 "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NextSeq 500/550 Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NextSeq 550Dx Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0 (RUO Mode)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NextSeq 550Dx Operating Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "lessThanOrEqual": "1.3.1",
              "status": "affected",
              "version": "1.0.0 ",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "1.3.3 "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NextSeq 1000/2000 Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "lessThanOrEqual": "1.4.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NovaSeq 6000 Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "lessThanOrEqual": "1.7 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NovaSeq Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "1.8"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Illumina reported these vulnerabilities to CISA. "
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eInstruments with Illumina Universal Copy Service v2.x are vulnerable due to binding to an unrestricted IP address. An unauthenticated malicious actor could use UCS to listen on all IP addresses, including those capable of accepting remote communications. \u003c/span\u003e\n\n\n\n\n\n\n\n"
            }
          ],
          "value": "\nInstruments with Illumina Universal Copy Service v2.x are vulnerable due to binding to an unrestricted IP address. An unauthenticated malicious actor could use UCS to listen on all IP addresses, including those capable of accepting remote communications. \n\n\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1327",
              "description": "CWE-1327 Binding to an Unrestricted IP Address",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-28T18:09:17.372Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-117-01"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://support.illumina.com/downloads/illumina-universal-copy-service-1-0.html"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "CVE-2023-1968",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIllumina recommends using the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.illumina.com/downloads/illumina-universal-copy-service-1-0.html\"\u003eUCS Vulnerability Instructions Guide\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;based on the user\u2019s specific system configuration to mitigate the vulnerabilities. Illumina recommends users read the instructions before downloading any software. \u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nIllumina recommends using the  UCS Vulnerability Instructions Guide https://support.illumina.com/downloads/illumina-universal-copy-service-1-0.html \u00a0based on the user\u2019s specific system configuration to mitigate the vulnerabilities. Illumina recommends users read the instructions before downloading any software. \n\n\n"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-1968",
    "datePublished": "2023-04-28T18:09:17.372Z",
    "dateReserved": "2023-04-10T14:51:29.181Z",
    "dateUpdated": "2024-08-02T06:05:27.076Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}