Search criteria

2 vulnerabilities found for MicroLogix 1100 & 1400 Controllers by Rockwell Automation

CVE-2022-46670 (GCVE-0-2022-46670)

Vulnerability from cvelistv5 – Published: 2022-12-16 20:12 – Updated: 2025-04-17 14:35
VLAI?
Title
Rockwell Automation MicroLogix 1100 & 1400 Vulnerable to Cross-Site Scripting Attack
Summary
Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution.  The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
Credits
Ryan Pickren, a security researcher from Georgia Institute of Technology
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:39:38.680Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-46670",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:35:20.399901Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:35:29.173Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MicroLogix 1100 \u0026 1400 Controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MicroLogix 1400-B/C",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "21.007 and below"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MicroLogix 1400-A",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "7.000 and below"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Ryan Pickren, a security researcher from Georgia Institute of Technology"
        }
      ],
      "datePublic": "2022-12-13T15:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eRockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute\u0026nbsp;of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. \u0026nbsp;The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. \u003c/span\u003e\n\n"
            }
          ],
          "value": "\nRockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute\u00a0of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. \u00a0The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. \n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-63",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-63 Cross-Site Scripting (XSS)"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-16T20:12:22.414Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rockwell Automation MicroLogix 1100 \u0026 1400 Vulnerable to Cross-Site Scripting Attack",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2022-46670",
    "datePublished": "2022-12-16T20:12:22.414Z",
    "dateReserved": "2022-12-06T15:27:58.542Z",
    "dateUpdated": "2025-04-17T14:35:29.173Z",
    "requesterUserId": "20b06643-9bf3-4d1d-a98d-f8db99f95a31",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-46670 (GCVE-0-2022-46670)

Vulnerability from nvd – Published: 2022-12-16 20:12 – Updated: 2025-04-17 14:35
VLAI?
Title
Rockwell Automation MicroLogix 1100 & 1400 Vulnerable to Cross-Site Scripting Attack
Summary
Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution.  The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
Credits
Ryan Pickren, a security researcher from Georgia Institute of Technology
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:39:38.680Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-46670",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:35:20.399901Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:35:29.173Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MicroLogix 1100 \u0026 1400 Controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MicroLogix 1400-B/C",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "21.007 and below"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MicroLogix 1400-A",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "7.000 and below"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Ryan Pickren, a security researcher from Georgia Institute of Technology"
        }
      ],
      "datePublic": "2022-12-13T15:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eRockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute\u0026nbsp;of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. \u0026nbsp;The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. \u003c/span\u003e\n\n"
            }
          ],
          "value": "\nRockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute\u00a0of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. \u00a0The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. \n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-63",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-63 Cross-Site Scripting (XSS)"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-16T20:12:22.414Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rockwell Automation MicroLogix 1100 \u0026 1400 Vulnerable to Cross-Site Scripting Attack",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2022-46670",
    "datePublished": "2022-12-16T20:12:22.414Z",
    "dateReserved": "2022-12-06T15:27:58.542Z",
    "dateUpdated": "2025-04-17T14:35:29.173Z",
    "requesterUserId": "20b06643-9bf3-4d1d-a98d-f8db99f95a31",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}