Search criteria
2 vulnerabilities found for Monitorwall by Bosch
CVE-2023-32230 (GCVE-0-2023-32230)
Vulnerability from cvelistv5 – Published: 2023-12-18 12:58 – Updated: 2024-08-02 15:10
VLAI?
Summary
An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation.
Severity ?
7.5 (High)
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch | Video Recording Manager |
Affected:
0 , ≤ 04.10.0079
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:10:24.221Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Video Recording Manager",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "04.10.0079",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Video Streaming Gateway",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "8.1.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThanOrEqual": "9.0.0.178",
"status": "affected",
"version": "9.0.0",
"versionType": "custom"
}
]
},
{
"product": "Monitorwall",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.00.0164",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "VJD-7513",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.40.0055",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "VJD-7523",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.40.0055",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703 Improper Check or Handling of Exceptional Conditions",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-18T12:58:08.690Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-32230",
"datePublished": "2023-12-18T12:58:08.690Z",
"dateReserved": "2023-05-04T21:01:16.508Z",
"dateUpdated": "2024-08-02T15:10:24.221Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32230 (GCVE-0-2023-32230)
Vulnerability from nvd – Published: 2023-12-18 12:58 – Updated: 2024-08-02 15:10
VLAI?
Summary
An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation.
Severity ?
7.5 (High)
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch | Video Recording Manager |
Affected:
0 , ≤ 04.10.0079
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:10:24.221Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Video Recording Manager",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "04.10.0079",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Video Streaming Gateway",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "8.1.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThanOrEqual": "9.0.0.178",
"status": "affected",
"version": "9.0.0",
"versionType": "custom"
}
]
},
{
"product": "Monitorwall",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.00.0164",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "VJD-7513",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.40.0055",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "VJD-7523",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.40.0055",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703 Improper Check or Handling of Exceptional Conditions",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-18T12:58:08.690Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-32230",
"datePublished": "2023-12-18T12:58:08.690Z",
"dateReserved": "2023-05-04T21:01:16.508Z",
"dateUpdated": "2024-08-02T15:10:24.221Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}