VAR-202308-2932
Vulnerability from variot - Updated: 2024-01-24 22:29NPort IAW5000A-I/O Series firmware version v2.2 and prior is affected by a hardcoded credential vulnerabilitywhich poses a potential risk to the security and integrity of the affected device. This vulnerability is attributed to the presence of a hardcoded key, which could potentially facilitate firmware manipulation. Moxa Inc. of NPort IAW5000A-I/O A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. MOXA NPort IAW5000A-I/O Series is a wireless device server used in an industrial environment by China MOXA Company. The server can realize the integration of on-site serial devices and wireless Ethernet, and integrates digital IO, which is suitable for industrial data acquisition applications
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-2932",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "nport iaw5000a-i\\/o",
"scope": "lte",
"trust": 1.0,
"vendor": "moxa",
"version": "2.2"
},
{
"model": "nport iaw5000a-i/o",
"scope": null,
"trust": 0.8,
"vendor": "moxa",
"version": null
},
{
"model": "nport iaw5000a-i/o",
"scope": "eq",
"trust": 0.8,
"vendor": "moxa",
"version": null
},
{
"model": "nport iaw5000a-i/o",
"scope": "lte",
"trust": 0.8,
"vendor": "moxa",
"version": "nport iaw5000a-i/o firmware 2.2 and earlier"
},
{
"model": "nport iaw5000a-i/o series",
"scope": "lte",
"trust": 0.6,
"vendor": "moxa",
"version": "\u003c=2.2"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-64101"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022519"
},
{
"db": "NVD",
"id": "CVE-2023-4204"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:moxa:nport_iaw5000a-i\\/o_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:moxa:nport_iaw5000a-i\\/o:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-4204"
}
]
},
"cve": "CVE-2023-4204",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-64101",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "psirt@moxa.com",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"impactScore": 2.5,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-4204",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-4204",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "psirt@moxa.com",
"id": "CVE-2023-4204",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2023-64101",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-64101"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022519"
},
{
"db": "NVD",
"id": "CVE-2023-4204"
},
{
"db": "NVD",
"id": "CVE-2023-4204"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "NPort IAW5000A-I/O Series firmware version v2.2 and prior is affected by a hardcoded credential vulnerabilitywhich poses a potential risk to the security and integrity of the affected device. This vulnerability is attributed to the presence of a hardcoded key, which could potentially facilitate firmware manipulation. Moxa Inc. of NPort IAW5000A-I/O A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. MOXA NPort IAW5000A-I/O Series is a wireless device server used in an industrial environment by China MOXA Company. The server can realize the integration of on-site serial devices and wireless Ethernet, and integrates digital IO, which is suitable for industrial data acquisition applications",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-4204"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022519"
},
{
"db": "CNVD",
"id": "CNVD-2023-64101"
},
{
"db": "VULMON",
"id": "CVE-2023-4204"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-4204",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022519",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-64101",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-4204",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-64101"
},
{
"db": "VULMON",
"id": "CVE-2023-4204"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022519"
},
{
"db": "NVD",
"id": "CVE-2023-4204"
}
]
},
"id": "VAR-202308-2932",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-64101"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-64101"
}
]
},
"last_update_date": "2024-01-24T22:29:00.677000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for MOXA NPort IAW5000A-I/O Series Hardcoded Credential Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/452576"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-64101"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.0
},
{
"problemtype": "Use hard-coded credentials (CWE-798) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022519"
},
{
"db": "NVD",
"id": "CVE-2023-4204"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-230304-nport-iaw5000a-i-o-series-hardcoded-credential-vulnerability"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-4204"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-64101"
},
{
"db": "VULMON",
"id": "CVE-2023-4204"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022519"
},
{
"db": "NVD",
"id": "CVE-2023-4204"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-64101"
},
{
"db": "VULMON",
"id": "CVE-2023-4204"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022519"
},
{
"db": "NVD",
"id": "CVE-2023-4204"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-08-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-64101"
},
{
"date": "2023-08-16T00:00:00",
"db": "VULMON",
"id": "CVE-2023-4204"
},
{
"date": "2024-01-23T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022519"
},
{
"date": "2023-08-16T16:15:11.573000",
"db": "NVD",
"id": "CVE-2023-4204"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-08-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-64101"
},
{
"date": "2023-08-16T00:00:00",
"db": "VULMON",
"id": "CVE-2023-4204"
},
{
"date": "2024-01-23T06:35:00",
"db": "JVNDB",
"id": "JVNDB-2023-022519"
},
{
"date": "2023-08-24T15:50:59.857000",
"db": "NVD",
"id": "CVE-2023-4204"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Moxa\u00a0Inc.\u00a0 of \u00a0NPort\u00a0IAW5000A-I/O\u00a0 Vulnerability related to use of hardcoded credentials in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022519"
}
],
"trust": 0.8
}
}
CVE-2020-25196 (GCVE-0-2020-25196)
Vulnerability from cvelistv5 – Published: 2020-12-23 14:08 – Updated: 2024-09-17 00:37- CWE-307 - Improper Restriction of Excessive Authentication Attempts
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MOXA | NPort IAW5000A-I/O |
Affected:
unspecified , ≤ Version 2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:04.375Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NPort IAW5000A-I/O",
"vendor": "MOXA",
"versions": [
{
"lessThanOrEqual": "Version 2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"datePublic": "2020-10-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307: Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-23T14:08:41",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
},
"title": "MOXA NPort IAW5000A-I/O Series",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-13T00:00:00.000Z",
"ID": "CVE-2020-25196",
"STATE": "PUBLIC",
"TITLE": "MOXA NPort IAW5000A-I/O Series"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NPort IAW5000A-I/O",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 2.1"
}
]
}
}
]
},
"vendor_name": "MOXA"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-307: Improper Restriction of Excessive Authentication Attempts"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25196",
"datePublished": "2020-12-23T14:08:41.583756Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-17T00:37:03.186Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25153 (GCVE-0-2020-25153)
Vulnerability from cvelistv5 – Published: 2020-12-23 14:08 – Updated: 2024-09-16 19:35- CWE-521 - Weak Password Requirements
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MOXA | NPort IAW5000A-I/O |
Affected:
unspecified , ≤ Version 2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.633Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NPort IAW5000A-I/O",
"vendor": "MOXA",
"versions": [
{
"lessThanOrEqual": "Version 2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"datePublic": "2020-10-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The built-in web service for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower does not require users to have strong passwords."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-521",
"description": "CWE-521: Weak Password Requirements",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-23T14:08:34",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
},
"title": "MOXA NPort IAW5000A-I/O Series",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-13T00:00:00.000Z",
"ID": "CVE-2020-25153",
"STATE": "PUBLIC",
"TITLE": "MOXA NPort IAW5000A-I/O Series"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NPort IAW5000A-I/O",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 2.1"
}
]
}
}
]
},
"vendor_name": "MOXA"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The built-in web service for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower does not require users to have strong passwords."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-521: Weak Password Requirements"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25153",
"datePublished": "2020-12-23T14:08:34.327193Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-16T19:35:37.248Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25192 (GCVE-0-2020-25192)
Vulnerability from cvelistv5 – Published: 2020-12-23 14:08 – Updated: 2024-09-16 22:41- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MOXA | NPort IAW5000A-I/O |
Affected:
unspecified , ≤ Version 2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:10.247Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NPort IAW5000A-I/O",
"vendor": "MOXA",
"versions": [
{
"lessThanOrEqual": "Version 2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"datePublic": "2020-10-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without proper authorization."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-23T14:08:28",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
},
"title": "MOXA NPort IAW5000A-I/O Series",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-13T00:00:00.000Z",
"ID": "CVE-2020-25192",
"STATE": "PUBLIC",
"TITLE": "MOXA NPort IAW5000A-I/O Series"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NPort IAW5000A-I/O",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 2.1"
}
]
}
}
]
},
"vendor_name": "MOXA"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without proper authorization."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25192",
"datePublished": "2020-12-23T14:08:28.438482Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-16T22:41:28.665Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25198 (GCVE-0-2020-25198)
Vulnerability from cvelistv5 – Published: 2020-12-23 14:08 – Updated: 2024-09-17 00:11- CWE-384 - Session Fixation
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MOXA | NPort IAW5000A-I/O |
Affected:
unspecified , ≤ Version 2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:04.438Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NPort IAW5000A-I/O",
"vendor": "MOXA",
"versions": [
{
"lessThanOrEqual": "Version 2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"datePublic": "2020-10-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has incorrectly implemented protections from session fixation, which may allow an attacker to gain access to a session and hijack it by stealing the user\u2019s cookies."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-384",
"description": "CWE-384 Session Fixation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-23T14:08:23",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
},
"title": "MOXA NPort IAW5000A-I/O Series",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-13T00:00:00.000Z",
"ID": "CVE-2020-25198",
"STATE": "PUBLIC",
"TITLE": "MOXA NPort IAW5000A-I/O Series"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NPort IAW5000A-I/O",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 2.1"
}
]
}
}
]
},
"vendor_name": "MOXA"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has incorrectly implemented protections from session fixation, which may allow an attacker to gain access to a session and hijack it by stealing the user\u2019s cookies."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-384 Session Fixation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25198",
"datePublished": "2020-12-23T14:08:23.404844Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-17T00:11:38.801Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25194 (GCVE-0-2020-25194)
Vulnerability from cvelistv5 – Published: 2020-12-23 14:08 – Updated: 2024-09-16 18:29- CWE-269 - Improper Privilege Management
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MOXA | NPort IAW5000A-I/O |
Affected:
unspecified , ≤ Version 2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:10.096Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NPort IAW5000A-I/O",
"vendor": "MOXA",
"versions": [
{
"lessThanOrEqual": "Version 2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"datePublic": "2020-10-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has improper privilege management, which may allow an attacker with user privileges to perform requests with administrative privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269: Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-23T14:08:17",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
},
"title": "MOXA NPort IAW5000A-I/O Series",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-13T00:00:00.000Z",
"ID": "CVE-2020-25194",
"STATE": "PUBLIC",
"TITLE": "MOXA NPort IAW5000A-I/O Series"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NPort IAW5000A-I/O",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 2.1"
}
]
}
}
]
},
"vendor_name": "MOXA"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has improper privilege management, which may allow an attacker with user privileges to perform requests with administrative privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269: Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25194",
"datePublished": "2020-12-23T14:08:17.398380Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-16T18:29:02.424Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25190 (GCVE-0-2020-25190)
Vulnerability from cvelistv5 – Published: 2020-12-23 14:07 – Updated: 2024-09-16 21:08- CWE-319 - Cleartext Transmission of Sensitive Information
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MOXA | NPort IAW5000A-I/O |
Affected:
unspecified , ≤ Version 2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.939Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NPort IAW5000A-I/O",
"vendor": "MOXA",
"versions": [
{
"lessThanOrEqual": "Version 2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"datePublic": "2020-10-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-23T14:07:56",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
},
"title": "MOXA NPort IAW5000A-I/O Series",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-13T00:00:00.000Z",
"ID": "CVE-2020-25190",
"STATE": "PUBLIC",
"TITLE": "MOXA NPort IAW5000A-I/O Series"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NPort IAW5000A-I/O",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 2.1"
}
]
}
}
]
},
"vendor_name": "MOXA"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-319: Cleartext Transmission of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25190",
"datePublished": "2020-12-23T14:07:56.166255Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-16T21:08:02.611Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25196 (GCVE-0-2020-25196)
Vulnerability from nvd – Published: 2020-12-23 14:08 – Updated: 2024-09-17 00:37- CWE-307 - Improper Restriction of Excessive Authentication Attempts
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MOXA | NPort IAW5000A-I/O |
Affected:
unspecified , ≤ Version 2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:04.375Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NPort IAW5000A-I/O",
"vendor": "MOXA",
"versions": [
{
"lessThanOrEqual": "Version 2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"datePublic": "2020-10-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307: Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-23T14:08:41",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
},
"title": "MOXA NPort IAW5000A-I/O Series",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-13T00:00:00.000Z",
"ID": "CVE-2020-25196",
"STATE": "PUBLIC",
"TITLE": "MOXA NPort IAW5000A-I/O Series"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NPort IAW5000A-I/O",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 2.1"
}
]
}
}
]
},
"vendor_name": "MOXA"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-307: Improper Restriction of Excessive Authentication Attempts"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25196",
"datePublished": "2020-12-23T14:08:41.583756Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-17T00:37:03.186Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25153 (GCVE-0-2020-25153)
Vulnerability from nvd – Published: 2020-12-23 14:08 – Updated: 2024-09-16 19:35- CWE-521 - Weak Password Requirements
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MOXA | NPort IAW5000A-I/O |
Affected:
unspecified , ≤ Version 2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.633Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NPort IAW5000A-I/O",
"vendor": "MOXA",
"versions": [
{
"lessThanOrEqual": "Version 2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"datePublic": "2020-10-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The built-in web service for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower does not require users to have strong passwords."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-521",
"description": "CWE-521: Weak Password Requirements",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-23T14:08:34",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
},
"title": "MOXA NPort IAW5000A-I/O Series",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-13T00:00:00.000Z",
"ID": "CVE-2020-25153",
"STATE": "PUBLIC",
"TITLE": "MOXA NPort IAW5000A-I/O Series"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NPort IAW5000A-I/O",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 2.1"
}
]
}
}
]
},
"vendor_name": "MOXA"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The built-in web service for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower does not require users to have strong passwords."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-521: Weak Password Requirements"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25153",
"datePublished": "2020-12-23T14:08:34.327193Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-16T19:35:37.248Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25192 (GCVE-0-2020-25192)
Vulnerability from nvd – Published: 2020-12-23 14:08 – Updated: 2024-09-16 22:41- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MOXA | NPort IAW5000A-I/O |
Affected:
unspecified , ≤ Version 2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:10.247Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NPort IAW5000A-I/O",
"vendor": "MOXA",
"versions": [
{
"lessThanOrEqual": "Version 2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"datePublic": "2020-10-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without proper authorization."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-23T14:08:28",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
},
"title": "MOXA NPort IAW5000A-I/O Series",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-13T00:00:00.000Z",
"ID": "CVE-2020-25192",
"STATE": "PUBLIC",
"TITLE": "MOXA NPort IAW5000A-I/O Series"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NPort IAW5000A-I/O",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 2.1"
}
]
}
}
]
},
"vendor_name": "MOXA"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without proper authorization."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25192",
"datePublished": "2020-12-23T14:08:28.438482Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-16T22:41:28.665Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25198 (GCVE-0-2020-25198)
Vulnerability from nvd – Published: 2020-12-23 14:08 – Updated: 2024-09-17 00:11- CWE-384 - Session Fixation
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MOXA | NPort IAW5000A-I/O |
Affected:
unspecified , ≤ Version 2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:04.438Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NPort IAW5000A-I/O",
"vendor": "MOXA",
"versions": [
{
"lessThanOrEqual": "Version 2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"datePublic": "2020-10-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has incorrectly implemented protections from session fixation, which may allow an attacker to gain access to a session and hijack it by stealing the user\u2019s cookies."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-384",
"description": "CWE-384 Session Fixation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-23T14:08:23",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
},
"title": "MOXA NPort IAW5000A-I/O Series",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-13T00:00:00.000Z",
"ID": "CVE-2020-25198",
"STATE": "PUBLIC",
"TITLE": "MOXA NPort IAW5000A-I/O Series"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NPort IAW5000A-I/O",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 2.1"
}
]
}
}
]
},
"vendor_name": "MOXA"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has incorrectly implemented protections from session fixation, which may allow an attacker to gain access to a session and hijack it by stealing the user\u2019s cookies."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-384 Session Fixation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25198",
"datePublished": "2020-12-23T14:08:23.404844Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-17T00:11:38.801Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25194 (GCVE-0-2020-25194)
Vulnerability from nvd – Published: 2020-12-23 14:08 – Updated: 2024-09-16 18:29- CWE-269 - Improper Privilege Management
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MOXA | NPort IAW5000A-I/O |
Affected:
unspecified , ≤ Version 2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:10.096Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NPort IAW5000A-I/O",
"vendor": "MOXA",
"versions": [
{
"lessThanOrEqual": "Version 2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"datePublic": "2020-10-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has improper privilege management, which may allow an attacker with user privileges to perform requests with administrative privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269: Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-23T14:08:17",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
},
"title": "MOXA NPort IAW5000A-I/O Series",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-13T00:00:00.000Z",
"ID": "CVE-2020-25194",
"STATE": "PUBLIC",
"TITLE": "MOXA NPort IAW5000A-I/O Series"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NPort IAW5000A-I/O",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 2.1"
}
]
}
}
]
},
"vendor_name": "MOXA"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has improper privilege management, which may allow an attacker with user privileges to perform requests with administrative privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269: Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25194",
"datePublished": "2020-12-23T14:08:17.398380Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-16T18:29:02.424Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25190 (GCVE-0-2020-25190)
Vulnerability from nvd – Published: 2020-12-23 14:07 – Updated: 2024-09-16 21:08- CWE-319 - Cleartext Transmission of Sensitive Information
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MOXA | NPort IAW5000A-I/O |
Affected:
unspecified , ≤ Version 2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.939Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NPort IAW5000A-I/O",
"vendor": "MOXA",
"versions": [
{
"lessThanOrEqual": "Version 2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"datePublic": "2020-10-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-23T14:07:56",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
},
"title": "MOXA NPort IAW5000A-I/O Series",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-13T00:00:00.000Z",
"ID": "CVE-2020-25190",
"STATE": "PUBLIC",
"TITLE": "MOXA NPort IAW5000A-I/O Series"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NPort IAW5000A-I/O",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 2.1"
}
]
}
}
]
},
"vendor_name": "MOXA"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-319: Cleartext Transmission of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems."
}
],
"source": {
"advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25190",
"datePublished": "2020-12-23T14:07:56.166255Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-16T21:08:02.611Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}