Type a vendor name or a vulnerability id.



All the vulnerabilites related to Siemens - OPUPI0 AMQP/MQTT
var-202405-0176
Vulnerability from variot

A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.30), SICORE Base system (All versions < V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. SICAM 8 Power automation platform is a universal, all-in-one hardware and software-based solution for all applications in the power supply sector. The SICAM A8000 RTU (Remote Terminal Unit) series is a modular device family for telecontrol and automation applications in all areas of energy supply. SICAM EGS (Enhanced Grid Sensor) is a gateway for local substations in distribution networks

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0176",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "cpci85 central processing/communication",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.30"
      },
      {
        "model": "opupi0 amqp/mqtt",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.30"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24522"
      }
    ]
  },
  "cve": "CVE-2024-31485",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.4,
            "id": "CNVD-2024-24522",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2024-31485",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-24522",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24522"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-31485"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions \u003c V5.30), SICORE Base system (All versions \u003c V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. SICAM 8 Power automation platform is a universal, all-in-one hardware and software-based solution for all applications in the power supply sector. The SICAM A8000 RTU (Remote Terminal Unit) series is a modular device family for telecontrol and automation applications in all areas of energy supply. SICAM EGS (Enhanced Grid Sensor) is a gateway for local substations in distribution networks",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-31485"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-24522"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "SIEMENS",
        "id": "SSA-871704",
        "trust": 1.6
      },
      {
        "db": "NVD",
        "id": "CVE-2024-31485",
        "trust": 1.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-24522",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24522"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-31485"
      }
    ]
  },
  "id": "VAR-202405-0176",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24522"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24522"
      }
    ]
  },
  "last_update_date": "2024-07-04T22:59:37.336000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Siemens SICAM Product Command Injection Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/547656"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24522"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-77",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-31485"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-871704.html"
      },
      {
        "trust": 1.0,
        "url": "http://seclists.org/fulldisclosure/2024/jul/4"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24522"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-31485"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24522"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-31485"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-24522"
      },
      {
        "date": "2024-05-14T16:16:51.033000",
        "db": "NVD",
        "id": "CVE-2024-31485"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-24522"
      },
      {
        "date": "2024-07-04T07:15:10.720000",
        "db": "NVD",
        "id": "CVE-2024-31485"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens SICAM Product Command Injection Vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24522"
      }
    ],
    "trust": 0.6
  }
}

var-202405-0175
Vulnerability from variot

A vulnerability has been identified in OPUPI0 AMQP/MQTT (All versions < V5.30). The affected devices stores MQTT client passwords without sufficient protection on the devices. An attacker with remote shell access or physical access could retrieve the credentials leading to confidentiality loss. SICAM 8 Power automation platform is a universal, all-in-one hardware and software-based solution for all applications in the power supply sector. The SICAM A8000 RTU (Remote Terminal Unit) series is a modular device family for telecontrol and automation applications in all areas of energy supply. SICAM EGS (Enhanced Grid Sensor) is a gateway for local substations in distribution networks.

Siemens SICAM products have a sensitive information plaintext storage vulnerability

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0175",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "opupi0 amqp/mqtt",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.30"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23526"
      }
    ]
  },
  "cve": "CVE-2024-31486",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "HIGH",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.9,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2024-23526",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:H/Au:S/C:C/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.6,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2024-31486",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-23526",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23526"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-31486"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in OPUPI0 AMQP/MQTT (All versions \u003c V5.30). The affected devices stores MQTT client passwords without sufficient protection on the devices.  An attacker with remote shell access or physical access could retrieve the credentials leading to confidentiality loss. SICAM 8 Power automation platform is a universal, all-in-one hardware and software-based solution for all applications in the power supply sector. The SICAM A8000 RTU (Remote Terminal Unit) series is a modular device family for telecontrol and automation applications in all areas of energy supply. SICAM EGS (Enhanced Grid Sensor) is a gateway for local substations in distribution networks. \n\nSiemens SICAM products have a sensitive information plaintext storage vulnerability",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-31486"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-23526"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "SIEMENS",
        "id": "SSA-871704",
        "trust": 1.6
      },
      {
        "db": "NVD",
        "id": "CVE-2024-31486",
        "trust": 1.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-23526",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23526"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-31486"
      }
    ]
  },
  "id": "VAR-202405-0175",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23526"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23526"
      }
    ]
  },
  "last_update_date": "2024-07-04T22:59:37.320000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Siemens SICAM product sensitive information plaintext storage vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/547201"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23526"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-312",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-31486"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-871704.html"
      },
      {
        "trust": 1.0,
        "url": "http://seclists.org/fulldisclosure/2024/jul/4"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23526"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-31486"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23526"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-31486"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-24T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-23526"
      },
      {
        "date": "2024-05-14T16:16:51.723000",
        "db": "NVD",
        "id": "CVE-2024-31486"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-22T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-23526"
      },
      {
        "date": "2024-07-04T07:15:10.823000",
        "db": "NVD",
        "id": "CVE-2024-31486"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens SICAM product sensitive information plaintext storage vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23526"
      }
    ],
    "trust": 0.6
  }
}

cve-2024-31486
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 01:52
Summary
A vulnerability has been identified in OPUPI0 AMQP/MQTT (All versions < V5.30). The affected devices stores MQTT client passwords without sufficient protection on the devices. An attacker with remote shell access or physical access could retrieve the credentials leading to confidentiality loss.
Impacted products
VendorProduct
SiemensOPUPI0 AMQP/MQTT
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-31486",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T14:20:23.441749Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T20:49:46.284Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:52:57.288Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-871704.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2024/Jul/4"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "OPUPI0 AMQP/MQTT",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.30",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in OPUPI0 AMQP/MQTT (All versions \u003c V5.30). The affected devices stores MQTT client passwords without sufficient protection on the devices.  An attacker with remote shell access or physical access could retrieve the credentials leading to confidentiality loss."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-14T10:02:26.227Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-871704.html"
        },
        {
          "url": "http://seclists.org/fulldisclosure/2024/Jul/4"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-31486",
    "datePublished": "2024-05-14T10:02:26.227Z",
    "dateReserved": "2024-04-04T11:43:06.066Z",
    "dateUpdated": "2024-08-02T01:52:57.288Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}