var-202405-0176
Vulnerability from variot

A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.30), SICORE Base system (All versions < V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. SICAM 8 Power automation platform is a universal, all-in-one hardware and software-based solution for all applications in the power supply sector. The SICAM A8000 RTU (Remote Terminal Unit) series is a modular device family for telecontrol and automation applications in all areas of energy supply. SICAM EGS (Enhanced Grid Sensor) is a gateway for local substations in distribution networks

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      configurations: {
         "@id": "https://www.variotdbs.pl/ref/configurations",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      exploit_availability: {
         "@id": "https://www.variotdbs.pl/ref/exploit_availability/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0176",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "cpci85 central processing/communication",
            scope: "lt",
            trust: 0.6,
            vendor: "siemens",
            version: "v5.30",
         },
         {
            model: "opupi0 amqp/mqtt",
            scope: "lt",
            trust: 0.6,
            vendor: "siemens",
            version: "v5.30",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-24522",
         },
      ],
   },
   cve: "CVE-2024-31485",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "MULTIPLE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 8.3,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 6.4,
                  id: "CNVD-2024-24522",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:M/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "productcert@siemens.com",
                  availabilityImpact: "HIGH",
                  baseScore: 7.2,
                  baseSeverity: "HIGH",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 1.2,
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "HIGH",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            ],
            severity: [
               {
                  author: "productcert@siemens.com",
                  id: "CVE-2024-31485",
                  trust: 1,
                  value: "HIGH",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-24522",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-24522",
         },
         {
            db: "NVD",
            id: "CVE-2024-31485",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.30), SICORE Base system (All versions < V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. SICAM 8 Power automation platform is a universal, all-in-one hardware and software-based solution for all applications in the power supply sector. The SICAM A8000 RTU (Remote Terminal Unit) series is a modular device family for telecontrol and automation applications in all areas of energy supply. SICAM EGS (Enhanced Grid Sensor) is a gateway for local substations in distribution networks",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-31485",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-24522",
         },
      ],
      trust: 1.44,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "SIEMENS",
            id: "SSA-871704",
            trust: 1.6,
         },
         {
            db: "NVD",
            id: "CVE-2024-31485",
            trust: 1.6,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-24522",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-24522",
         },
         {
            db: "NVD",
            id: "CVE-2024-31485",
         },
      ],
   },
   id: "VAR-202405-0176",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-24522",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "ICS",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-24522",
         },
      ],
   },
   last_update_date: "2024-07-04T22:59:37.336000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for Siemens SICAM Product Command Injection Vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchinfo/show/547656",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-24522",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-77",
            trust: 1,
         },
      ],
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-31485",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 1.6,
            url: "https://cert-portal.siemens.com/productcert/html/ssa-871704.html",
         },
         {
            trust: 1,
            url: "http://seclists.org/fulldisclosure/2024/jul/4",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-24522",
         },
         {
            db: "NVD",
            id: "CVE-2024-31485",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-24522",
         },
         {
            db: "NVD",
            id: "CVE-2024-31485",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-05-30T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-24522",
         },
         {
            date: "2024-05-14T16:16:51.033000",
            db: "NVD",
            id: "CVE-2024-31485",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-05-28T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-24522",
         },
         {
            date: "2024-07-04T07:15:10.720000",
            db: "NVD",
            id: "CVE-2024-31485",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "Siemens SICAM Product Command Injection Vulnerability",
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-24522",
         },
      ],
      trust: 0.6,
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.