Search criteria

10 vulnerabilities found for OnCell G3150A-LTE Series by Moxa

CVE-2024-4641 (GCVE-0-2024-4641)

Vulnerability from cvelistv5 – Published: 2024-06-25 09:23 – Updated: 2024-08-01 20:47
VLAI?
Title
OnCell G3470A-LTE Series: Authenticated Format String Errors
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service.
CWE
  • CWE-134 - Use of Externally-Controlled Format String
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "oncell_g3470a-lte-us",
            "vendor": "moxa",
            "versions": [
              {
                "lessThanOrEqual": "1.7.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4641",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T17:38:59.616518Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T17:39:20.742Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.226Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-135",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-135: Format String Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-134",
              "description": "CWE-134: Use of Externally-Controlled Format String",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T09:23:30.502Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n\n\n\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Format String Errors",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa recommends users to implement the following mitigations if necessary: \n\n  *  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4641",
    "datePublished": "2024-06-25T09:23:30.502Z",
    "dateReserved": "2024-05-08T00:44:45.219Z",
    "dateUpdated": "2024-08-01T20:47:41.226Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4640 (GCVE-0-2024-4640)

Vulnerability from cvelistv5 – Published: 2024-06-25 09:19 – Updated: 2024-08-01 20:47
VLAI?
Title
OnCell G3470A-LTE Series: Authenticated Command Injection via sendTestEmail
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4640",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-25T13:15:03.203557Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-25T13:15:08.856Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100: Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T09:19:08.712Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n\n\n\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Command Injection via sendTestEmail",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa recommends users to implement the following mitigations if necessary: \n\n  *  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4640",
    "datePublished": "2024-06-25T09:19:08.712Z",
    "dateReserved": "2024-05-08T00:44:43.828Z",
    "dateUpdated": "2024-08-01T20:47:41.484Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4639 (GCVE-0-2024-4639)

Vulnerability from cvelistv5 – Published: 2024-06-25 09:15 – Updated: 2024-08-01 20:47
VLAI?
Title
OnCell G3470A-LTE Series: Authenticated Command Injection via webDelIPSec
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4639",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-25T13:34:53.804173Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-25T13:35:01.665Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.194Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248: Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T09:15:03.229Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003cbr\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Command Injection via webDelIPSec",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa recommends users to implement the following mitigations if necessary: \n\n  *  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4639",
    "datePublished": "2024-06-25T09:15:03.229Z",
    "dateReserved": "2024-05-08T00:44:42.405Z",
    "dateUpdated": "2024-08-01T20:47:41.194Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-6094 (GCVE-0-2023-6094)

Vulnerability from cvelistv5 – Published: 2023-12-31 09:57 – Updated: 2024-08-26 20:21
VLAI?
Title
OnCell G3150A-LTE Series: Web Server Transmits Cleartext Credentials
Summary
A vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:21:17.204Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-6094",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-26T20:21:02.392909Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-26T20:21:09.811Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.3",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.\u003c/p\u003e"
            }
          ],
          "value": "A vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-117",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-117: Interception"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-04T15:08:08.275Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3150A-LTE Series: Web Server Transmits Cleartext Credentials",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSince Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093 and CVE-2023-6094. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \u003c/p\u003e\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eReduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003ePlace control system networks and remote devices behind firewalls, isolating them from business networks. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003eWhen remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Since Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093 and CVE-2023-6094. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \n\nMoxa recommends users to implement the following mitigations if necessary: \n\n  *  Reduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \n\n\n  *  Place control system networks and remote devices behind firewalls, isolating them from business networks. \n\n\n  *  When remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\n\n\n\n\n"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2023-6094",
    "datePublished": "2023-12-31T09:57:27.448Z",
    "dateReserved": "2023-11-13T02:17:37.177Z",
    "dateUpdated": "2024-08-26T20:21:09.811Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-6093 (GCVE-0-2023-6093)

Vulnerability from cvelistv5 – Published: 2023-12-31 09:53 – Updated: 2024-08-02 08:21
VLAI?
Title
OnCell G3150A-LTE Series: Clickjacking Vulnerability
Summary
A clickjacking vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. This vulnerability is caused by incorrectly restricts frame objects, which can lead to user confusion about which interface the user is interacting with. This vulnerability may lead the attacker to trick the user into interacting with the application.
CWE
  • CWE-1021 - Improper Restriction of Rendered UI Layers or Frames
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:21:17.143Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.3",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA clickjacking vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior.  This vulnerability is caused by incorrectly restricts frame objects, which can lead to user confusion about which interface the user is interacting with. This vulnerability may lead the attacker to trick the user into interacting with the application.\u003c/p\u003e"
            }
          ],
          "value": "A clickjacking vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior.  This vulnerability is caused by incorrectly restricts frame objects, which can lead to user confusion about which interface the user is interacting with. This vulnerability may lead the attacker to trick the user into interacting with the application.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-103",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-103: Clickjacking"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1021",
              "description": "CWE-1021: Improper Restriction of Rendered UI Layers or Frames",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-04T14:59:17.638Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3150A-LTE Series: Clickjacking Vulnerability",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003e\u003c/p\u003e\u003cp\u003eSince Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \u0026nbsp;\u003c/p\u003e\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eReduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003ePlace control system networks and remote devices behind firewalls, isolating them from business networks. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003eWhen remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "\n\n\nSince Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \u00a0\n\nMoxa recommends users to implement the following mitigations if necessary: \n\n  *  Reduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \n\n\n  *  Place control system networks and remote devices behind firewalls, isolating them from business networks. \n\n\n  *  When remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\n\n\n\n\n\n\n"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2023-6093",
    "datePublished": "2023-12-31T09:53:04.790Z",
    "dateReserved": "2023-11-13T02:17:35.853Z",
    "dateUpdated": "2024-08-02T08:21:17.143Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4641 (GCVE-0-2024-4641)

Vulnerability from nvd – Published: 2024-06-25 09:23 – Updated: 2024-08-01 20:47
VLAI?
Title
OnCell G3470A-LTE Series: Authenticated Format String Errors
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service.
CWE
  • CWE-134 - Use of Externally-Controlled Format String
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "oncell_g3470a-lte-us",
            "vendor": "moxa",
            "versions": [
              {
                "lessThanOrEqual": "1.7.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4641",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T17:38:59.616518Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T17:39:20.742Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.226Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-135",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-135: Format String Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-134",
              "description": "CWE-134: Use of Externally-Controlled Format String",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T09:23:30.502Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n\n\n\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Format String Errors",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa recommends users to implement the following mitigations if necessary: \n\n  *  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4641",
    "datePublished": "2024-06-25T09:23:30.502Z",
    "dateReserved": "2024-05-08T00:44:45.219Z",
    "dateUpdated": "2024-08-01T20:47:41.226Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4640 (GCVE-0-2024-4640)

Vulnerability from nvd – Published: 2024-06-25 09:19 – Updated: 2024-08-01 20:47
VLAI?
Title
OnCell G3470A-LTE Series: Authenticated Command Injection via sendTestEmail
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4640",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-25T13:15:03.203557Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-25T13:15:08.856Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100: Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T09:19:08.712Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n\n\n\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Command Injection via sendTestEmail",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa recommends users to implement the following mitigations if necessary: \n\n  *  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4640",
    "datePublished": "2024-06-25T09:19:08.712Z",
    "dateReserved": "2024-05-08T00:44:43.828Z",
    "dateUpdated": "2024-08-01T20:47:41.484Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4639 (GCVE-0-2024-4639)

Vulnerability from nvd – Published: 2024-06-25 09:15 – Updated: 2024-08-01 20:47
VLAI?
Title
OnCell G3470A-LTE Series: Authenticated Command Injection via webDelIPSec
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4639",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-25T13:34:53.804173Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-25T13:35:01.665Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.194Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248: Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T09:15:03.229Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003cbr\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Command Injection via webDelIPSec",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa recommends users to implement the following mitigations if necessary: \n\n  *  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4639",
    "datePublished": "2024-06-25T09:15:03.229Z",
    "dateReserved": "2024-05-08T00:44:42.405Z",
    "dateUpdated": "2024-08-01T20:47:41.194Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-6094 (GCVE-0-2023-6094)

Vulnerability from nvd – Published: 2023-12-31 09:57 – Updated: 2024-08-26 20:21
VLAI?
Title
OnCell G3150A-LTE Series: Web Server Transmits Cleartext Credentials
Summary
A vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:21:17.204Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-6094",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-26T20:21:02.392909Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-26T20:21:09.811Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.3",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.\u003c/p\u003e"
            }
          ],
          "value": "A vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-117",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-117: Interception"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-04T15:08:08.275Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3150A-LTE Series: Web Server Transmits Cleartext Credentials",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSince Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093 and CVE-2023-6094. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \u003c/p\u003e\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eReduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003ePlace control system networks and remote devices behind firewalls, isolating them from business networks. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003eWhen remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Since Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093 and CVE-2023-6094. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \n\nMoxa recommends users to implement the following mitigations if necessary: \n\n  *  Reduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \n\n\n  *  Place control system networks and remote devices behind firewalls, isolating them from business networks. \n\n\n  *  When remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\n\n\n\n\n"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2023-6094",
    "datePublished": "2023-12-31T09:57:27.448Z",
    "dateReserved": "2023-11-13T02:17:37.177Z",
    "dateUpdated": "2024-08-26T20:21:09.811Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-6093 (GCVE-0-2023-6093)

Vulnerability from nvd – Published: 2023-12-31 09:53 – Updated: 2024-08-02 08:21
VLAI?
Title
OnCell G3150A-LTE Series: Clickjacking Vulnerability
Summary
A clickjacking vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. This vulnerability is caused by incorrectly restricts frame objects, which can lead to user confusion about which interface the user is interacting with. This vulnerability may lead the attacker to trick the user into interacting with the application.
CWE
  • CWE-1021 - Improper Restriction of Rendered UI Layers or Frames
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:21:17.143Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.3",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA clickjacking vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior.  This vulnerability is caused by incorrectly restricts frame objects, which can lead to user confusion about which interface the user is interacting with. This vulnerability may lead the attacker to trick the user into interacting with the application.\u003c/p\u003e"
            }
          ],
          "value": "A clickjacking vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior.  This vulnerability is caused by incorrectly restricts frame objects, which can lead to user confusion about which interface the user is interacting with. This vulnerability may lead the attacker to trick the user into interacting with the application.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-103",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-103: Clickjacking"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1021",
              "description": "CWE-1021: Improper Restriction of Rendered UI Layers or Frames",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-04T14:59:17.638Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3150A-LTE Series: Clickjacking Vulnerability",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003e\u003c/p\u003e\u003cp\u003eSince Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \u0026nbsp;\u003c/p\u003e\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eReduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003ePlace control system networks and remote devices behind firewalls, isolating them from business networks. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003eWhen remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "\n\n\nSince Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \u00a0\n\nMoxa recommends users to implement the following mitigations if necessary: \n\n  *  Reduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \n\n\n  *  Place control system networks and remote devices behind firewalls, isolating them from business networks. \n\n\n  *  When remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\n\n\n\n\n\n\n"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2023-6093",
    "datePublished": "2023-12-31T09:53:04.790Z",
    "dateReserved": "2023-11-13T02:17:35.853Z",
    "dateUpdated": "2024-08-02T08:21:17.143Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}