Vulnerabilites related to Eclipse Foundation - OpenJ9
cve-2023-5676
Vulnerability from cvelistv5
Published
2023-11-15 14:02
Modified
2024-08-29 14:50
Summary
In Eclipse OpenJ9 before version 0.41.0, the JVM can be forced into an infinite busy hang on a spinlock or a segmentation fault if a shutdown signal (SIGTERM, SIGINT or SIGHUP) is received before the JVM has finished initializing.
Impacted products
Vendor Product Version
Eclipse Foundation OpenJ9 Version: 0   
Create a notification for this product.
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-02T08:07:32.636Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/eclipse-openj9/openj9/pull/18085",
               },
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://gitlab.eclipse.org/security/cve-assignement/-/issues/13",
               },
            ],
            title: "CVE Program Container",
         },
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2023-5676",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "partial",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-08-29T14:41:09.024509Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-08-29T14:50:03.835Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unaffected",
               product: "OpenJ9",
               vendor: "Eclipse Foundation",
               versions: [
                  {
                     lessThan: "0.41.0",
                     status: "affected",
                     version: "0",
                     versionType: "semver",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               supportingMedia: [
                  {
                     base64: false,
                     type: "text/html",
                     value: "In Eclipse OpenJ9 before version 0.41.0, the JVM can be forced into an infinite busy hang on a spinlock or a segmentation fault if a shutdown signal (SIGTERM, SIGINT or SIGHUP) is received before the JVM has finished initializing.<br>",
                  },
               ],
               value: "In Eclipse OpenJ9 before version 0.41.0, the JVM can be forced into an infinite busy hang on a spinlock or a segmentation fault if a shutdown signal (SIGTERM, SIGINT or SIGHUP) is received before the JVM has finished initializing.\n",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  attackComplexity: "HIGH",
                  attackVector: "LOCAL",
                  availabilityImpact: "HIGH",
                  baseScore: 4.1,
                  baseSeverity: "MEDIUM",
                  confidentialityImpact: "NONE",
                  integrityImpact: "NONE",
                  privilegesRequired: "HIGH",
                  scope: "UNCHANGED",
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H",
                  version: "3.1",
               },
               format: "CVSS",
               scenarios: [
                  {
                     lang: "en",
                     value: "GENERAL",
                  },
               ],
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-364",
                     description: "CWE-364: Signal Handler Race Condition",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2023-11-15T14:02:01.422Z",
            orgId: "e51fbebd-6053-4e49-959f-1b94eeb69a2c",
            shortName: "eclipse",
         },
         references: [
            {
               url: "https://github.com/eclipse-openj9/openj9/pull/18085",
            },
            {
               url: "https://gitlab.eclipse.org/security/cve-assignement/-/issues/13",
            },
         ],
         source: {
            discovery: "UNKNOWN",
         },
         title: "Eclipse OpenJ9 possible infinite busy hang",
         x_generator: {
            engine: "Vulnogram 0.1.0-dev",
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "e51fbebd-6053-4e49-959f-1b94eeb69a2c",
      assignerShortName: "eclipse",
      cveId: "CVE-2023-5676",
      datePublished: "2023-11-15T14:02:01.422Z",
      dateReserved: "2023-10-20T04:59:29.125Z",
      dateUpdated: "2024-08-29T14:50:03.835Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}