All the vulnerabilites related to Hitachi Energy - PCM600 Update Manager
cve-2021-22278
Vulnerability from cvelistv5
Published
2021-10-28 12:45
Modified
2024-09-16 18:23
Summary
A certificate validation vulnerability in PCM600 Update Manager allows attacker to get unwanted software packages to be installed on computer which has PCM600 installed.
Impacted products
Vendor Product Version
ABB PCM600 Update Manager Version: 2.1
Version: 2.1.0.4
Version: 2.2
Version: 2.2.0.1
Version: 2.2.0.2
Version: 2.2.0.23
Version: 2.3.0.60
Version: 2.4.20041.1
Version: 2.4.20119.2
Hitachi Energy PCM600 Version: 2.7   < unspecified
Version: unspecified   <
Hitachi Energy PCM600 Update Manager Version: 2.1
Version: 2.1.0.4
Version: 2.2
Version: 2.2.0.1
Version: 2.2.0.2
Version: 2.2.0.23
Version: 2.3.0.60
Version: 2.4.20041.1
Version: 2.4.20119.2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:37:18.443Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001142\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000056\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PCM600",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "2.7",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "2.10",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PCM600 Update Manager",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            },
            {
              "status": "affected",
              "version": "2.1.0.4"
            },
            {
              "status": "affected",
              "version": "2.2"
            },
            {
              "status": "affected",
              "version": "2.2.0.1"
            },
            {
              "status": "affected",
              "version": "2.2.0.2"
            },
            {
              "status": "affected",
              "version": "2.2.0.23"
            },
            {
              "status": "affected",
              "version": "2.3.0.60"
            },
            {
              "status": "affected",
              "version": "2.4.20041.1"
            },
            {
              "status": "affected",
              "version": "2.4.20119.2"
            }
          ]
        },
        {
          "product": "PCM600",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "2.7",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "2.10",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PCM600 Update Manager",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            },
            {
              "status": "affected",
              "version": "2.1.0.4"
            },
            {
              "status": "affected",
              "version": "2.2"
            },
            {
              "status": "affected",
              "version": "2.2.0.1"
            },
            {
              "status": "affected",
              "version": "2.2.0.2"
            },
            {
              "status": "affected",
              "version": "2.2.0.23"
            },
            {
              "status": "affected",
              "version": "2.3.0.60"
            },
            {
              "status": "affected",
              "version": "2.4.20041.1"
            },
            {
              "status": "affected",
              "version": "2.4.20119.2"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "ABB and Hitachi Energy thank CyTRICS researcher May Chaffin for helping to identify the vulnerabilities and protecting our customers."
        }
      ],
      "datePublic": "2021-10-19T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A certificate validation vulnerability in PCM600 Update Manager allows attacker to get unwanted software packages to be installed on computer which has PCM600 installed."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-295",
              "description": "CWE-295 Improper Certificate Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-10-28T12:45:58",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001142\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000056\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Install latest PCM600 Update Manager version 2.4.21218.1 or newer."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Certificate verification vulnerability  in Update Manager of PCM600 Engineering Tool",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "DATE_PUBLIC": "2021-10-19T10:02:00.000Z",
          "ID": "CVE-2021-22278",
          "STATE": "PUBLIC",
          "TITLE": "Certificate verification vulnerability  in Update Manager of PCM600 Engineering Tool"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PCM600",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003e=",
                            "version_value": "2.7"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_value": "2.10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PCM600 Update Manager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.1.0.4"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.2"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.2.0.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.2.0.2"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.2.0.23"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.3.0.60"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.4.20041.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.4.20119.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PCM600",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003e=",
                            "version_value": "2.7"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_value": "2.10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PCM600 Update Manager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.1.0.4"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.2"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.2.0.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.2.0.2"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.2.0.23"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.3.0.60"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.4.20041.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.4.20119.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hitachi Energy"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "ABB and Hitachi Energy thank CyTRICS researcher May Chaffin for helping to identify the vulnerabilities and protecting our customers."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A certificate validation vulnerability in PCM600 Update Manager allows attacker to get unwanted software packages to be installed on computer which has PCM600 installed."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-295 Improper Certificate Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001142\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "MISC",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001142\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000056\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "MISC",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000056\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Install latest PCM600 Update Manager version 2.4.21218.1 or newer."
          }
        ],
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2021-22278",
    "datePublished": "2021-10-28T12:45:58.086957Z",
    "dateReserved": "2021-01-05T00:00:00",
    "dateUpdated": "2024-09-16T18:23:59.443Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}