Search criteria

4 vulnerabilities found for POWER METER SICAM Q200 family by Siemens

CVE-2025-40753 (GCVE-0-2025-40753)

Vulnerability from cvelistv5 – Published: 2025-08-12 11:17 – Updated: 2025-08-13 20:18
VLAI?
Summary
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40753",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T13:30:20.774490Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-13T20:18:21.296Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q200 family",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.80",
              "status": "affected",
              "version": "V2.70",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q200 family (All versions \u003e= V2.70 \u003c V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:17:09.077Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-529291.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-40753",
    "datePublished": "2025-08-12T11:17:09.077Z",
    "dateReserved": "2025-04-16T08:39:30.031Z",
    "dateUpdated": "2025-08-13T20:18:21.296Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40752 (GCVE-0-2025-40752)

Vulnerability from cvelistv5 – Published: 2025-08-12 11:17 – Updated: 2025-08-13 20:18
VLAI?
Summary
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40752",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T13:30:23.184849Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-13T20:18:28.424Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q200 family",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.80",
              "status": "affected",
              "version": "V2.70",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q200 family (All versions \u003e= V2.70 \u003c V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:17:07.776Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-529291.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-40752",
    "datePublished": "2025-08-12T11:17:07.776Z",
    "dateReserved": "2025-04-16T08:39:30.031Z",
    "dateUpdated": "2025-08-13T20:18:28.424Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40753 (GCVE-0-2025-40753)

Vulnerability from nvd – Published: 2025-08-12 11:17 – Updated: 2025-08-13 20:18
VLAI?
Summary
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40753",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T13:30:20.774490Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-13T20:18:21.296Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q200 family",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.80",
              "status": "affected",
              "version": "V2.70",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q200 family (All versions \u003e= V2.70 \u003c V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:17:09.077Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-529291.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-40753",
    "datePublished": "2025-08-12T11:17:09.077Z",
    "dateReserved": "2025-04-16T08:39:30.031Z",
    "dateUpdated": "2025-08-13T20:18:21.296Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40752 (GCVE-0-2025-40752)

Vulnerability from nvd – Published: 2025-08-12 11:17 – Updated: 2025-08-13 20:18
VLAI?
Summary
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40752",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T13:30:23.184849Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-13T20:18:28.424Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.62",
              "status": "affected",
              "version": "V2.60",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "POWER METER SICAM Q200 family",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.80",
              "status": "affected",
              "version": "V2.70",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q200 family (All versions \u003e= V2.70 \u003c V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:17:07.776Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-529291.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-40752",
    "datePublished": "2025-08-12T11:17:07.776Z",
    "dateReserved": "2025-04-16T08:39:30.031Z",
    "dateUpdated": "2025-08-13T20:18:28.424Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}