Search criteria
12 vulnerabilities found for QNX Software Development Platform (QNX SDP) by BlackBerry
CVE-2019-8998 (GCVE-0-2019-8998)
Vulnerability from cvelistv5 – Published: 2019-07-12 15:30 – Updated: 2025-08-22 15:09
VLAI?
Summary
An information disclosure vulnerability leading to a potential local escalation of privilege in the procfs service (the /proc filesystem) of BlackBerry QNX Software Development Platform version(s) 6.5.0 SP1 and earlier could allow an attacker to potentially gain unauthorized access to a chosen process address space.
Severity ?
7.8 (High)
CWE
- Information disclosure leading to a potential local escalation of privilege
- CWE-413 - Improper Resource Locking
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| BlackBerry | QNX Software Development Platform (QNX SDP) |
Affected:
6.5.0 SP1 and earlier
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:31:37.569Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000057178"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QNX Software Development Platform (QNX SDP)",
"vendor": "BlackBerry",
"versions": [
{
"status": "affected",
"version": "6.5.0 SP1 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn information disclosure vulnerability leading to a potential local escalation of privilege in the procfs service (the /proc filesystem) of BlackBerry QNX Software Development Platform version(s) 6.5.0 SP1 and earlier could allow an attacker to potentially gain unauthorized access to a chosen process address space.\u003c/p\u003e"
}
],
"value": "An information disclosure vulnerability leading to a potential local escalation of privilege in the procfs service (the /proc filesystem) of BlackBerry QNX Software Development Platform version(s) 6.5.0 SP1 and earlier could allow an attacker to potentially gain unauthorized access to a chosen process address space."
}
],
"impacts": [
{
"capecId": "CAPEC-180",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information disclosure leading to a potential local escalation of privilege",
"lang": "en"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-413",
"description": "CWE-413 Improper Resource Locking",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T15:09:48.377Z",
"orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"shortName": "blackberry"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000057178"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@blackberry.com",
"ID": "CVE-2019-8998",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "BlackBerry QNX Software Development Platform (QNX SDP)",
"version": {
"version_data": [
{
"version_value": "6.5.0 SP1 and earlier"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An information disclosure vulnerability leading to a potential local escalation of privilege in the procfs service (the /proc filesystem) of BlackBerry QNX Software Development Platform version(s) 6.5.0 SP1 and earlier could allow an attacker to potentially gain unauthorized access to a chosen process address space."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information disclosure leading to a potential local escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000057178",
"refsource": "MISC",
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000057178"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"assignerShortName": "blackberry",
"cveId": "CVE-2019-8998",
"datePublished": "2019-07-12T15:30:28",
"dateReserved": "2019-02-21T00:00:00",
"dateUpdated": "2025-08-22T15:09:48.377Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-3891 (GCVE-0-2017-3891)
Vulnerability from cvelistv5 – Published: 2017-11-14 21:00 – Updated: 2025-08-22 14:48
VLAI?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an elevation of privilege vulnerability in the default configuration of the QNX SDP with QNet enabled on networks comprising two or more QNet nodes could allow an attacker to access local and remote files or take ownership of files on other QNX nodes regardless of permissions by executing commands targeting arbitrary nodes from a secondary QNX 6.6.0 QNet node.
Severity ?
9.6 (Critical)
CWE
- Elevation of privilege
- CWE-923 - Improper Restriction of Communication Channel to Intended Endpoints
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| BlackBerry | QNX Software Development Platform (QNX SDP) |
Affected:
6.6.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:39:41.298Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.midnightbluelabs.com/blog/2017/12/8/elevation-of-privilege-vulnerability-in-qnx-qnet"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QNX Software Development Platform (QNX SDP)",
"vendor": "BlackBerry",
"versions": [
{
"status": "affected",
"version": "6.6.0"
}
]
}
],
"datePublic": "2017-11-14T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn BlackBerry QNX Software Development Platform (SDP) 6.6.0, an elevation of privilege vulnerability in the default configuration of the QNX SDP with QNet enabled on networks comprising two or more QNet nodes could allow an attacker to access local and remote files or take ownership of files on other QNX nodes regardless of permissions by executing commands targeting arbitrary nodes from a secondary QNX 6.6.0 QNet node.\u003c/p\u003e"
}
],
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an elevation of privilege vulnerability in the default configuration of the QNX SDP with QNet enabled on networks comprising two or more QNet nodes could allow an attacker to access local and remote files or take ownership of files on other QNX nodes regardless of permissions by executing commands targeting arbitrary nodes from a secondary QNX 6.6.0 QNet node."
}
],
"impacts": [
{
"capecId": "CAPEC-216",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-216 Communication Channel Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Elevation of privilege",
"lang": "en"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-923",
"description": "CWE-923 Improper Restriction of Communication Channel to Intended Endpoints",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T14:48:09.392Z",
"orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"shortName": "blackberry"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.midnightbluelabs.com/blog/2017/12/8/elevation-of-privilege-vulnerability-in-qnx-qnet"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@blackberry.com",
"DATE_PUBLIC": "2017-11-14T00:00:00",
"ID": "CVE-2017-3891",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QNX Software Development Platform (QNX SDP)",
"version": {
"version_data": [
{
"version_value": "6.6.0"
}
]
}
}
]
},
"vendor_name": "BlackBerry"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an elevation of privilege vulnerability in the default configuration of the QNX SDP with QNet enabled on networks comprising two or more QNet nodes could allow an attacker to access local and remote files or take ownership of files on other QNX nodes regardless of permissions by executing commands targeting arbitrary nodes from a secondary QNX 6.6.0 QNet node."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Elevation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674",
"refsource": "CONFIRM",
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
},
{
"name": "https://www.midnightbluelabs.com/blog/2017/12/8/elevation-of-privilege-vulnerability-in-qnx-qnet",
"refsource": "MISC",
"url": "https://www.midnightbluelabs.com/blog/2017/12/8/elevation-of-privilege-vulnerability-in-qnx-qnet"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"assignerShortName": "blackberry",
"cveId": "CVE-2017-3891",
"datePublished": "2017-11-14T21:00:00Z",
"dateReserved": "2016-12-21T00:00:00",
"dateUpdated": "2025-08-22T14:48:09.392Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-3893 (GCVE-0-2017-3893)
Vulnerability from cvelistv5 – Published: 2017-11-14 21:00 – Updated: 2025-07-22 15:25
VLAI?
Title
Incomplete vulnerability mitigations
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0, the default configuration of the QNX SDP system did not in all circumstances prevent attackers from modifying the GOT or PLT tables with buffer overflow attacks.
Severity ?
CWE
- CWE-693 - Protection mechanism failure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| BlackBerry | QNX Software Development Platform (QNX SDP) |
Affected:
6.6.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:39:41.483Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QNX Software Development Platform (QNX SDP)",
"vendor": "BlackBerry",
"versions": [
{
"status": "affected",
"version": "6.6.0"
}
]
}
],
"datePublic": "2017-11-14T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn BlackBerry QNX Software Development Platform (SDP) 6.6.0, the default configuration of the QNX SDP system did not in all circumstances prevent attackers from modifying the GOT or PLT tables with buffer overflow attacks.\u003c/p\u003e"
}
],
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, the default configuration of the QNX SDP system did not in all circumstances prevent attackers from modifying the GOT or PLT tables with buffer overflow attacks."
}
],
"impacts": [
{
"capecId": "CAPEC-679",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-679 Exploitation of Improperly Configured or Implemented Memory Protections"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 1.9,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-693",
"description": "CWE-693 Protection mechanism failure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-22T15:25:07.257Z",
"orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"shortName": "blackberry"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Incomplete vulnerability mitigations",
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@blackberry.com",
"DATE_PUBLIC": "2017-11-14T00:00:00",
"ID": "CVE-2017-3893",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QNX Software Development Platform (QNX SDP)",
"version": {
"version_data": [
{
"version_value": "6.6.0"
}
]
}
}
]
},
"vendor_name": "BlackBerry"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, the default configuration of the QNX SDP system did not in all circumstances prevent attackers from modifying the GOT or PLT tables with buffer overflow attacks."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Flawed vulnerability mitigation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674",
"refsource": "CONFIRM",
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"assignerShortName": "blackberry",
"cveId": "CVE-2017-3893",
"datePublished": "2017-11-14T21:00:00Z",
"dateReserved": "2016-12-21T00:00:00",
"dateUpdated": "2025-07-22T15:25:07.257Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-9369 (GCVE-0-2017-9369)
Vulnerability from cvelistv5 – Published: 2017-11-14 21:00 – Updated: 2025-08-26 17:30
VLAI?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader.
Severity ?
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| BlackBerry | QNX Software Development Platform (SDP) |
Affected:
6.6.0
Affected: 6.5.0 SP1 and earlier |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T17:02:44.381Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QNX Software Development Platform (SDP)",
"vendor": "BlackBerry",
"versions": [
{
"status": "affected",
"version": "6.6.0"
},
{
"status": "affected",
"version": "6.5.0 SP1 and earlier"
}
]
}
],
"datePublic": "2017-11-14T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader.\u003c/p\u003e"
}
],
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader."
}
],
"impacts": [
{
"capecId": "CAPEC-13",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-13 Subverting Environment Variable Values"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-26T17:30:03.762Z",
"orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"shortName": "blackberry"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@blackberry.com",
"DATE_PUBLIC": "2017-11-14T00:00:00",
"ID": "CVE-2017-9369",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QNX Software Development Platform (QNX SDP)",
"version": {
"version_data": [
{
"version_value": "6.6.0"
},
{
"version_value": "6.5.0 SP1 and earlier"
}
]
}
}
]
},
"vendor_name": "BlackBerry"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information disclosure across privilege barriers."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674",
"refsource": "CONFIRM",
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"assignerShortName": "blackberry",
"cveId": "CVE-2017-9369",
"datePublished": "2017-11-14T21:00:00Z",
"dateReserved": "2017-06-02T00:00:00",
"dateUpdated": "2025-08-26T17:30:03.762Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-9371 (GCVE-0-2017-9371)
Vulnerability from cvelistv5 – Published: 2017-11-14 21:00 – Updated: 2025-08-22 15:05
VLAI?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, a loss of integrity vulnerability in the default configuration of the QNX SDP could allow an attacker being able to reduce the entropy of the PRNG, making other blended attacks more practical by gaining control over environmental factors that influence seed generation.
Severity ?
CWE
- Loss of integrity vulnerability
- CWE-332 - Insufficient Entropy in PRNG
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| BlackBerry | QNX Software Development Platform (QNX SDP) |
Affected:
6.6.0
Affected: 6.5.0 SP1 and earlier |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T17:02:44.372Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.blackberry.com/kb/articleDetail?language=en_US\u0026articleNumber=000046674"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QNX Software Development Platform (QNX SDP)",
"vendor": "BlackBerry",
"versions": [
{
"status": "affected",
"version": "6.6.0"
},
{
"status": "affected",
"version": "6.5.0 SP1 and earlier"
}
]
}
],
"datePublic": "2017-11-14T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, a loss of integrity vulnerability in the default configuration of the QNX SDP could allow an attacker being able to reduce the entropy of the PRNG, making other blended attacks more practical by gaining control over environmental factors that influence seed generation.\u003c/p\u003e"
}
],
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, a loss of integrity vulnerability in the default configuration of the QNX SDP could allow an attacker being able to reduce the entropy of the PRNG, making other blended attacks more practical by gaining control over environmental factors that influence seed generation."
}
],
"impacts": [
{
"capecId": "CAPEC-554",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-554 Functionality Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 2.6,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Loss of integrity vulnerability",
"lang": "en"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-332",
"description": "CWE-332 Insufficient Entropy in PRNG",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T15:05:29.013Z",
"orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"shortName": "blackberry"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.blackberry.com/kb/articleDetail?language=en_US\u0026articleNumber=000046674"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@blackberry.com",
"DATE_PUBLIC": "2017-11-14T00:00:00",
"ID": "CVE-2017-9371",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QNX Software Development Platform (QNX SDP)",
"version": {
"version_data": [
{
"version_value": "6.6.0"
},
{
"version_value": "6.5.0 SP1 and earlier"
}
]
}
}
]
},
"vendor_name": "BlackBerry"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, a loss of integrity vulnerability in the default configuration of the QNX SDP could allow an attacker being able to reduce the entropy of the PRNG, making other blended attacks more practical by gaining control over environmental factors that influence seed generation."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Loss of integrity vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.blackberry.com/kb/articleDetail?language=en_US\u0026articleNumber=000046674",
"refsource": "CONFIRM",
"url": "http://support.blackberry.com/kb/articleDetail?language=en_US\u0026articleNumber=000046674"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"assignerShortName": "blackberry",
"cveId": "CVE-2017-9371",
"datePublished": "2017-11-14T21:00:00Z",
"dateReserved": "2017-06-02T00:00:00",
"dateUpdated": "2025-08-22T15:05:29.013Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-3892 (GCVE-0-2017-3892)
Vulnerability from cvelistv5 – Published: 2017-11-14 21:00 – Updated: 2025-08-26 17:27
VLAI?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout that could be used in a blended attack by executing commands targeting procfs resources.
Severity ?
CWE
- Information disclosure
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| BlackBerry | QNX Software Development Platform (SDP) |
Affected:
6.6.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:39:41.193Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QNX Software Development Platform (SDP)",
"vendor": "BlackBerry",
"versions": [
{
"status": "affected",
"version": "6.6.0"
}
]
}
],
"datePublic": "2017-11-14T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn BlackBerry QNX Software Development Platform (SDP) 6.6.0, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout that could be used in a blended attack by executing commands targeting procfs resources.\u003c/p\u003e"
}
],
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout that could be used in a blended attack by executing commands targeting procfs resources."
}
],
"impacts": [
{
"capecId": "CAPEC-116",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-116 Excavation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information disclosure",
"lang": "en"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-26T17:27:35.177Z",
"orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"shortName": "blackberry"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@blackberry.com",
"DATE_PUBLIC": "2017-11-14T00:00:00",
"ID": "CVE-2017-3892",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QNX Software Development Platform (QNX SDP)",
"version": {
"version_data": [
{
"version_value": "6.6.0"
}
]
}
}
]
},
"vendor_name": "BlackBerry"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout that could be used in a blended attack by executing commands targeting procfs resources."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674",
"refsource": "CONFIRM",
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"assignerShortName": "blackberry",
"cveId": "CVE-2017-3892",
"datePublished": "2017-11-14T21:00:00Z",
"dateReserved": "2016-12-21T00:00:00",
"dateUpdated": "2025-08-26T17:27:35.177Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8998 (GCVE-0-2019-8998)
Vulnerability from nvd – Published: 2019-07-12 15:30 – Updated: 2025-08-22 15:09
VLAI?
Summary
An information disclosure vulnerability leading to a potential local escalation of privilege in the procfs service (the /proc filesystem) of BlackBerry QNX Software Development Platform version(s) 6.5.0 SP1 and earlier could allow an attacker to potentially gain unauthorized access to a chosen process address space.
Severity ?
7.8 (High)
CWE
- Information disclosure leading to a potential local escalation of privilege
- CWE-413 - Improper Resource Locking
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| BlackBerry | QNX Software Development Platform (QNX SDP) |
Affected:
6.5.0 SP1 and earlier
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:31:37.569Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000057178"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QNX Software Development Platform (QNX SDP)",
"vendor": "BlackBerry",
"versions": [
{
"status": "affected",
"version": "6.5.0 SP1 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn information disclosure vulnerability leading to a potential local escalation of privilege in the procfs service (the /proc filesystem) of BlackBerry QNX Software Development Platform version(s) 6.5.0 SP1 and earlier could allow an attacker to potentially gain unauthorized access to a chosen process address space.\u003c/p\u003e"
}
],
"value": "An information disclosure vulnerability leading to a potential local escalation of privilege in the procfs service (the /proc filesystem) of BlackBerry QNX Software Development Platform version(s) 6.5.0 SP1 and earlier could allow an attacker to potentially gain unauthorized access to a chosen process address space."
}
],
"impacts": [
{
"capecId": "CAPEC-180",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information disclosure leading to a potential local escalation of privilege",
"lang": "en"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-413",
"description": "CWE-413 Improper Resource Locking",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T15:09:48.377Z",
"orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"shortName": "blackberry"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000057178"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@blackberry.com",
"ID": "CVE-2019-8998",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "BlackBerry QNX Software Development Platform (QNX SDP)",
"version": {
"version_data": [
{
"version_value": "6.5.0 SP1 and earlier"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An information disclosure vulnerability leading to a potential local escalation of privilege in the procfs service (the /proc filesystem) of BlackBerry QNX Software Development Platform version(s) 6.5.0 SP1 and earlier could allow an attacker to potentially gain unauthorized access to a chosen process address space."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information disclosure leading to a potential local escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000057178",
"refsource": "MISC",
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000057178"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"assignerShortName": "blackberry",
"cveId": "CVE-2019-8998",
"datePublished": "2019-07-12T15:30:28",
"dateReserved": "2019-02-21T00:00:00",
"dateUpdated": "2025-08-22T15:09:48.377Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-3891 (GCVE-0-2017-3891)
Vulnerability from nvd – Published: 2017-11-14 21:00 – Updated: 2025-08-22 14:48
VLAI?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an elevation of privilege vulnerability in the default configuration of the QNX SDP with QNet enabled on networks comprising two or more QNet nodes could allow an attacker to access local and remote files or take ownership of files on other QNX nodes regardless of permissions by executing commands targeting arbitrary nodes from a secondary QNX 6.6.0 QNet node.
Severity ?
9.6 (Critical)
CWE
- Elevation of privilege
- CWE-923 - Improper Restriction of Communication Channel to Intended Endpoints
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| BlackBerry | QNX Software Development Platform (QNX SDP) |
Affected:
6.6.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:39:41.298Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.midnightbluelabs.com/blog/2017/12/8/elevation-of-privilege-vulnerability-in-qnx-qnet"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QNX Software Development Platform (QNX SDP)",
"vendor": "BlackBerry",
"versions": [
{
"status": "affected",
"version": "6.6.0"
}
]
}
],
"datePublic": "2017-11-14T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn BlackBerry QNX Software Development Platform (SDP) 6.6.0, an elevation of privilege vulnerability in the default configuration of the QNX SDP with QNet enabled on networks comprising two or more QNet nodes could allow an attacker to access local and remote files or take ownership of files on other QNX nodes regardless of permissions by executing commands targeting arbitrary nodes from a secondary QNX 6.6.0 QNet node.\u003c/p\u003e"
}
],
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an elevation of privilege vulnerability in the default configuration of the QNX SDP with QNet enabled on networks comprising two or more QNet nodes could allow an attacker to access local and remote files or take ownership of files on other QNX nodes regardless of permissions by executing commands targeting arbitrary nodes from a secondary QNX 6.6.0 QNet node."
}
],
"impacts": [
{
"capecId": "CAPEC-216",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-216 Communication Channel Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Elevation of privilege",
"lang": "en"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-923",
"description": "CWE-923 Improper Restriction of Communication Channel to Intended Endpoints",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T14:48:09.392Z",
"orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"shortName": "blackberry"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.midnightbluelabs.com/blog/2017/12/8/elevation-of-privilege-vulnerability-in-qnx-qnet"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@blackberry.com",
"DATE_PUBLIC": "2017-11-14T00:00:00",
"ID": "CVE-2017-3891",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QNX Software Development Platform (QNX SDP)",
"version": {
"version_data": [
{
"version_value": "6.6.0"
}
]
}
}
]
},
"vendor_name": "BlackBerry"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an elevation of privilege vulnerability in the default configuration of the QNX SDP with QNet enabled on networks comprising two or more QNet nodes could allow an attacker to access local and remote files or take ownership of files on other QNX nodes regardless of permissions by executing commands targeting arbitrary nodes from a secondary QNX 6.6.0 QNet node."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Elevation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674",
"refsource": "CONFIRM",
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
},
{
"name": "https://www.midnightbluelabs.com/blog/2017/12/8/elevation-of-privilege-vulnerability-in-qnx-qnet",
"refsource": "MISC",
"url": "https://www.midnightbluelabs.com/blog/2017/12/8/elevation-of-privilege-vulnerability-in-qnx-qnet"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"assignerShortName": "blackberry",
"cveId": "CVE-2017-3891",
"datePublished": "2017-11-14T21:00:00Z",
"dateReserved": "2016-12-21T00:00:00",
"dateUpdated": "2025-08-22T14:48:09.392Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-3893 (GCVE-0-2017-3893)
Vulnerability from nvd – Published: 2017-11-14 21:00 – Updated: 2025-07-22 15:25
VLAI?
Title
Incomplete vulnerability mitigations
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0, the default configuration of the QNX SDP system did not in all circumstances prevent attackers from modifying the GOT or PLT tables with buffer overflow attacks.
Severity ?
CWE
- CWE-693 - Protection mechanism failure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| BlackBerry | QNX Software Development Platform (QNX SDP) |
Affected:
6.6.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:39:41.483Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QNX Software Development Platform (QNX SDP)",
"vendor": "BlackBerry",
"versions": [
{
"status": "affected",
"version": "6.6.0"
}
]
}
],
"datePublic": "2017-11-14T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn BlackBerry QNX Software Development Platform (SDP) 6.6.0, the default configuration of the QNX SDP system did not in all circumstances prevent attackers from modifying the GOT or PLT tables with buffer overflow attacks.\u003c/p\u003e"
}
],
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, the default configuration of the QNX SDP system did not in all circumstances prevent attackers from modifying the GOT or PLT tables with buffer overflow attacks."
}
],
"impacts": [
{
"capecId": "CAPEC-679",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-679 Exploitation of Improperly Configured or Implemented Memory Protections"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 1.9,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-693",
"description": "CWE-693 Protection mechanism failure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-22T15:25:07.257Z",
"orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"shortName": "blackberry"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Incomplete vulnerability mitigations",
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@blackberry.com",
"DATE_PUBLIC": "2017-11-14T00:00:00",
"ID": "CVE-2017-3893",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QNX Software Development Platform (QNX SDP)",
"version": {
"version_data": [
{
"version_value": "6.6.0"
}
]
}
}
]
},
"vendor_name": "BlackBerry"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, the default configuration of the QNX SDP system did not in all circumstances prevent attackers from modifying the GOT or PLT tables with buffer overflow attacks."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Flawed vulnerability mitigation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674",
"refsource": "CONFIRM",
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"assignerShortName": "blackberry",
"cveId": "CVE-2017-3893",
"datePublished": "2017-11-14T21:00:00Z",
"dateReserved": "2016-12-21T00:00:00",
"dateUpdated": "2025-07-22T15:25:07.257Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-9369 (GCVE-0-2017-9369)
Vulnerability from nvd – Published: 2017-11-14 21:00 – Updated: 2025-08-26 17:30
VLAI?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader.
Severity ?
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| BlackBerry | QNX Software Development Platform (SDP) |
Affected:
6.6.0
Affected: 6.5.0 SP1 and earlier |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T17:02:44.381Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QNX Software Development Platform (SDP)",
"vendor": "BlackBerry",
"versions": [
{
"status": "affected",
"version": "6.6.0"
},
{
"status": "affected",
"version": "6.5.0 SP1 and earlier"
}
]
}
],
"datePublic": "2017-11-14T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader.\u003c/p\u003e"
}
],
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader."
}
],
"impacts": [
{
"capecId": "CAPEC-13",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-13 Subverting Environment Variable Values"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-26T17:30:03.762Z",
"orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"shortName": "blackberry"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@blackberry.com",
"DATE_PUBLIC": "2017-11-14T00:00:00",
"ID": "CVE-2017-9369",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QNX Software Development Platform (QNX SDP)",
"version": {
"version_data": [
{
"version_value": "6.6.0"
},
{
"version_value": "6.5.0 SP1 and earlier"
}
]
}
}
]
},
"vendor_name": "BlackBerry"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information disclosure across privilege barriers."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674",
"refsource": "CONFIRM",
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"assignerShortName": "blackberry",
"cveId": "CVE-2017-9369",
"datePublished": "2017-11-14T21:00:00Z",
"dateReserved": "2017-06-02T00:00:00",
"dateUpdated": "2025-08-26T17:30:03.762Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-9371 (GCVE-0-2017-9371)
Vulnerability from nvd – Published: 2017-11-14 21:00 – Updated: 2025-08-22 15:05
VLAI?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, a loss of integrity vulnerability in the default configuration of the QNX SDP could allow an attacker being able to reduce the entropy of the PRNG, making other blended attacks more practical by gaining control over environmental factors that influence seed generation.
Severity ?
CWE
- Loss of integrity vulnerability
- CWE-332 - Insufficient Entropy in PRNG
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| BlackBerry | QNX Software Development Platform (QNX SDP) |
Affected:
6.6.0
Affected: 6.5.0 SP1 and earlier |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T17:02:44.372Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.blackberry.com/kb/articleDetail?language=en_US\u0026articleNumber=000046674"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QNX Software Development Platform (QNX SDP)",
"vendor": "BlackBerry",
"versions": [
{
"status": "affected",
"version": "6.6.0"
},
{
"status": "affected",
"version": "6.5.0 SP1 and earlier"
}
]
}
],
"datePublic": "2017-11-14T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, a loss of integrity vulnerability in the default configuration of the QNX SDP could allow an attacker being able to reduce the entropy of the PRNG, making other blended attacks more practical by gaining control over environmental factors that influence seed generation.\u003c/p\u003e"
}
],
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, a loss of integrity vulnerability in the default configuration of the QNX SDP could allow an attacker being able to reduce the entropy of the PRNG, making other blended attacks more practical by gaining control over environmental factors that influence seed generation."
}
],
"impacts": [
{
"capecId": "CAPEC-554",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-554 Functionality Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 2.6,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Loss of integrity vulnerability",
"lang": "en"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-332",
"description": "CWE-332 Insufficient Entropy in PRNG",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T15:05:29.013Z",
"orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"shortName": "blackberry"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.blackberry.com/kb/articleDetail?language=en_US\u0026articleNumber=000046674"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@blackberry.com",
"DATE_PUBLIC": "2017-11-14T00:00:00",
"ID": "CVE-2017-9371",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QNX Software Development Platform (QNX SDP)",
"version": {
"version_data": [
{
"version_value": "6.6.0"
},
{
"version_value": "6.5.0 SP1 and earlier"
}
]
}
}
]
},
"vendor_name": "BlackBerry"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, a loss of integrity vulnerability in the default configuration of the QNX SDP could allow an attacker being able to reduce the entropy of the PRNG, making other blended attacks more practical by gaining control over environmental factors that influence seed generation."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Loss of integrity vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.blackberry.com/kb/articleDetail?language=en_US\u0026articleNumber=000046674",
"refsource": "CONFIRM",
"url": "http://support.blackberry.com/kb/articleDetail?language=en_US\u0026articleNumber=000046674"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"assignerShortName": "blackberry",
"cveId": "CVE-2017-9371",
"datePublished": "2017-11-14T21:00:00Z",
"dateReserved": "2017-06-02T00:00:00",
"dateUpdated": "2025-08-22T15:05:29.013Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-3892 (GCVE-0-2017-3892)
Vulnerability from nvd – Published: 2017-11-14 21:00 – Updated: 2025-08-26 17:27
VLAI?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout that could be used in a blended attack by executing commands targeting procfs resources.
Severity ?
CWE
- Information disclosure
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| BlackBerry | QNX Software Development Platform (SDP) |
Affected:
6.6.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:39:41.193Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QNX Software Development Platform (SDP)",
"vendor": "BlackBerry",
"versions": [
{
"status": "affected",
"version": "6.6.0"
}
]
}
],
"datePublic": "2017-11-14T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn BlackBerry QNX Software Development Platform (SDP) 6.6.0, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout that could be used in a blended attack by executing commands targeting procfs resources.\u003c/p\u003e"
}
],
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout that could be used in a blended attack by executing commands targeting procfs resources."
}
],
"impacts": [
{
"capecId": "CAPEC-116",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-116 Excavation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information disclosure",
"lang": "en"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-26T17:27:35.177Z",
"orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"shortName": "blackberry"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@blackberry.com",
"DATE_PUBLIC": "2017-11-14T00:00:00",
"ID": "CVE-2017-3892",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QNX Software Development Platform (QNX SDP)",
"version": {
"version_data": [
{
"version_value": "6.6.0"
}
]
}
}
]
},
"vendor_name": "BlackBerry"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout that could be used in a blended attack by executing commands targeting procfs resources."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674",
"refsource": "CONFIRM",
"url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
"assignerShortName": "blackberry",
"cveId": "CVE-2017-3892",
"datePublished": "2017-11-14T21:00:00Z",
"dateReserved": "2016-12-21T00:00:00",
"dateUpdated": "2025-08-26T17:27:35.177Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",