Search criteria
2 vulnerabilities found for RSLogix™ Micro Developer and Starter by Rockwell Automation
CVE-2024-7847 (GCVE-0-2024-7847)
Vulnerability from cvelistv5 – Published: 2024-10-14 13:47 – Updated: 2024-10-15 14:05
VLAI?
Title
RSLogix™ 5 and RSLogix 500® Remote Code Execution Via VBA Embedded Script
Summary
VULNERABILITY DETAILS
Rockwell Automation used the latest versions of the CVSS scoring system to assess the following vulnerabilities. The following vulnerabilities were reported to us by Sharon Brizinov of Claroty Research - Team82.
A feature in the affected products enables users to prepare a project file with an embedded VBA script and can be configured to run once the project file has been opened without user intervention. This feature can be abused to trick a legitimate user into executing malicious code upon opening an infected RSP/RSS project file. If exploited, a threat actor may be able to perform a remote code execution. Connected devices may also be impacted by exploitation of this vulnerability.
Severity ?
CWE
- CWE-345 - Insufficient Verification of Data Authenticity
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rockwell Automation | RSLogix 500® |
Affected:
All
|
||||||||||||
|
||||||||||||||
Credits
Sharon Brizinov of Claroty Research - Team82
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:rockwellautomation:rslogix_500:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rslogix_500",
"vendor": "rockwellautomation",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:rslogix_micro_developer:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rslogix_micro_developer",
"vendor": "rockwellautomation",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:rslogix_micro_starter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rslogix_micro_starter",
"vendor": "rockwellautomation",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:rslogix_5:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rslogix_5",
"vendor": "rockwellautomation",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7847",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-14T15:18:18.670939Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T14:05:45.670Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "RSLogix 500\u00ae",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RSLogix\u2122 Micro Developer and Starter",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RSLogix\u2122 5",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "All"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Sharon Brizinov of Claroty Research - Team82"
}
],
"datePublic": "2024-09-19T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003cb\u003eVULNERABILITY DETAILS\u003c/b\u003e\u003c/p\u003e\u003cp\u003eRockwell Automation used the latest versions of the CVSS scoring system to assess the following vulnerabilities. The following vulnerabilities were reported to us by Sharon Brizinov of Claroty Research - Team82. \u003c/p\u003e\u003cp\u003eA feature in the affected products enables users to prepare a project file with an embedded VBA script and can be configured to run once the project file has been opened without user intervention. This feature can be abused to trick a legitimate user into executing malicious code upon opening an infected RSP/RSS project file. If exploited, a threat actor may be able to perform a remote code execution. Connected devices may also be impacted by exploitation of this vulnerability.\u003c/p\u003e"
}
],
"value": "VULNERABILITY DETAILS\n\nRockwell Automation used the latest versions of the CVSS scoring system to assess the following vulnerabilities. The following vulnerabilities were reported to us by Sharon Brizinov of Claroty Research - Team82. \n\nA feature in the affected products enables users to prepare a project file with an embedded VBA script and can be configured to run once the project file has been opened without user intervention. This feature can be abused to trick a legitimate user into executing malicious code upon opening an infected RSP/RSS project file. If exploited, a threat actor may be able to perform a remote code execution. Connected devices may also be impacted by exploitation of this vulnerability."
}
],
"impacts": [
{
"capecId": "CAPEC-19",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-19 Embedding Scripts within Scripts"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-14T13:47:14.540Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1701.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "RSLogix\u2122 5 and RSLogix 500\u00ae Remote Code Execution Via VBA Embedded Script",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003cb\u003eMitigations and Workarounds \u003c/b\u003e\u003c/p\u003e\u003cp\u003eUsers using the affected software are encouraged to apply the following mitigations and security best practices, where possible. \u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Deny the execution feature in FactoryTalk\u00ae Administration Console, when not needed, by navigating to \u201cPolicies\u201d, selecting \u2018\u201dEnable/Disable VBA\u201d, and then checking the \u201cDeny\u201d box to block VBA code execution.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Save project files in a Trusted\u00ae location where only administrators can modify it and verify file integrity.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Utilize the VBA editor protection feature, which locks the VBA code from viewing and editing by setting a password.\u003c/p\u003e"
}
],
"value": "Mitigations and Workarounds \n\nUsers using the affected software are encouraged to apply the following mitigations and security best practices, where possible. \n\n\u00b7 \u00a0 \u00a0 \u00a0 Deny the execution feature in FactoryTalk\u00ae Administration Console, when not needed, by navigating to \u201cPolicies\u201d, selecting \u2018\u201dEnable/Disable VBA\u201d, and then checking the \u201cDeny\u201d box to block VBA code execution.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Save project files in a Trusted\u00ae location where only administrators can modify it and verify file integrity.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Utilize the VBA editor protection feature, which locks the VBA code from viewing and editing by setting a password."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-7847",
"datePublished": "2024-10-14T13:47:14.540Z",
"dateReserved": "2024-08-15T15:51:22.233Z",
"dateUpdated": "2024-10-15T14:05:45.670Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7847 (GCVE-0-2024-7847)
Vulnerability from nvd – Published: 2024-10-14 13:47 – Updated: 2024-10-15 14:05
VLAI?
Title
RSLogix™ 5 and RSLogix 500® Remote Code Execution Via VBA Embedded Script
Summary
VULNERABILITY DETAILS
Rockwell Automation used the latest versions of the CVSS scoring system to assess the following vulnerabilities. The following vulnerabilities were reported to us by Sharon Brizinov of Claroty Research - Team82.
A feature in the affected products enables users to prepare a project file with an embedded VBA script and can be configured to run once the project file has been opened without user intervention. This feature can be abused to trick a legitimate user into executing malicious code upon opening an infected RSP/RSS project file. If exploited, a threat actor may be able to perform a remote code execution. Connected devices may also be impacted by exploitation of this vulnerability.
Severity ?
CWE
- CWE-345 - Insufficient Verification of Data Authenticity
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rockwell Automation | RSLogix 500® |
Affected:
All
|
||||||||||||
|
||||||||||||||
Credits
Sharon Brizinov of Claroty Research - Team82
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:rockwellautomation:rslogix_500:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rslogix_500",
"vendor": "rockwellautomation",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:rslogix_micro_developer:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rslogix_micro_developer",
"vendor": "rockwellautomation",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:rslogix_micro_starter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rslogix_micro_starter",
"vendor": "rockwellautomation",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:rslogix_5:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rslogix_5",
"vendor": "rockwellautomation",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7847",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-14T15:18:18.670939Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T14:05:45.670Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "RSLogix 500\u00ae",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RSLogix\u2122 Micro Developer and Starter",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RSLogix\u2122 5",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "All"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Sharon Brizinov of Claroty Research - Team82"
}
],
"datePublic": "2024-09-19T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003cb\u003eVULNERABILITY DETAILS\u003c/b\u003e\u003c/p\u003e\u003cp\u003eRockwell Automation used the latest versions of the CVSS scoring system to assess the following vulnerabilities. The following vulnerabilities were reported to us by Sharon Brizinov of Claroty Research - Team82. \u003c/p\u003e\u003cp\u003eA feature in the affected products enables users to prepare a project file with an embedded VBA script and can be configured to run once the project file has been opened without user intervention. This feature can be abused to trick a legitimate user into executing malicious code upon opening an infected RSP/RSS project file. If exploited, a threat actor may be able to perform a remote code execution. Connected devices may also be impacted by exploitation of this vulnerability.\u003c/p\u003e"
}
],
"value": "VULNERABILITY DETAILS\n\nRockwell Automation used the latest versions of the CVSS scoring system to assess the following vulnerabilities. The following vulnerabilities were reported to us by Sharon Brizinov of Claroty Research - Team82. \n\nA feature in the affected products enables users to prepare a project file with an embedded VBA script and can be configured to run once the project file has been opened without user intervention. This feature can be abused to trick a legitimate user into executing malicious code upon opening an infected RSP/RSS project file. If exploited, a threat actor may be able to perform a remote code execution. Connected devices may also be impacted by exploitation of this vulnerability."
}
],
"impacts": [
{
"capecId": "CAPEC-19",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-19 Embedding Scripts within Scripts"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-14T13:47:14.540Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1701.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "RSLogix\u2122 5 and RSLogix 500\u00ae Remote Code Execution Via VBA Embedded Script",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003cb\u003eMitigations and Workarounds \u003c/b\u003e\u003c/p\u003e\u003cp\u003eUsers using the affected software are encouraged to apply the following mitigations and security best practices, where possible. \u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Deny the execution feature in FactoryTalk\u00ae Administration Console, when not needed, by navigating to \u201cPolicies\u201d, selecting \u2018\u201dEnable/Disable VBA\u201d, and then checking the \u201cDeny\u201d box to block VBA code execution.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Save project files in a Trusted\u00ae location where only administrators can modify it and verify file integrity.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Utilize the VBA editor protection feature, which locks the VBA code from viewing and editing by setting a password.\u003c/p\u003e"
}
],
"value": "Mitigations and Workarounds \n\nUsers using the affected software are encouraged to apply the following mitigations and security best practices, where possible. \n\n\u00b7 \u00a0 \u00a0 \u00a0 Deny the execution feature in FactoryTalk\u00ae Administration Console, when not needed, by navigating to \u201cPolicies\u201d, selecting \u2018\u201dEnable/Disable VBA\u201d, and then checking the \u201cDeny\u201d box to block VBA code execution.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Save project files in a Trusted\u00ae location where only administrators can modify it and verify file integrity.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Utilize the VBA editor protection feature, which locks the VBA code from viewing and editing by setting a password."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-7847",
"datePublished": "2024-10-14T13:47:14.540Z",
"dateReserved": "2024-08-15T15:51:22.233Z",
"dateUpdated": "2024-10-15T14:05:45.670Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}