Search criteria

4 vulnerabilities found for SD9364 by Vivotek

CVE-2024-7442 (GCVE-0-2024-7442)

Vulnerability from cvelistv5 – Published: 2024-08-03 18:00 – Updated: 2024-08-05 15:04
VLAI?
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
CWE
Assigner
References
https://vuldb.com/?id.273527 vdb-entrytechnical-description
https://vuldb.com/?ctiid.273527 signaturepermissions-required
https://vuldb.com/?submit.383843 third-party-advisory
https://yjz233.notion.site/vivotek-SD9364-has-com… broken-link
Impacted products
Vendor Product Version
Vivotek SD9364 Affected: VVTK-0103f
Create a notification for this product.
Credits
jylsec (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7442",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-05T15:04:20.396388Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:04:43.133Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SD9364",
          "vendor": "Vivotek",
          "versions": [
            {
              "status": "affected",
              "version": "VVTK-0103f"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jylsec (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Vivotek SD9364 VVTK-0103f ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion getenv der Datei upload_file.cgi. Dank Manipulation des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-03T18:00:09.890Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-273527 | Vivotek SD9364 upload_file.cgi getenv command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.273527"
        },
        {
          "name": "VDB-273527 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.273527"
        },
        {
          "name": "Submit #383843 | vivotek SD9364 VVTK-0103f command injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.383843"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://yjz233.notion.site/vivotek-SD9364-has-command-injection-vulnerability-in-upload_file-cgi-5cef6da27b25479497dda0b73670f565?pvs=4"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-02T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-02T23:46:16.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Vivotek SD9364 upload_file.cgi getenv command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7442",
    "datePublished": "2024-08-03T18:00:09.890Z",
    "dateReserved": "2024-08-02T21:36:40.547Z",
    "dateUpdated": "2024-08-05T15:04:43.133Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-7441 (GCVE-0-2024-7441)

Vulnerability from cvelistv5 – Published: 2024-08-03 17:31 – Updated: 2024-08-07 16:24
VLAI?
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
https://vuldb.com/?id.273526 vdb-entrytechnical-description
https://vuldb.com/?ctiid.273526 signaturepermissions-required
https://vuldb.com/?submit.383842 third-party-advisory
https://yjz233.notion.site/vivotek-SD9364-has-sta… broken-linkexploit
Impacted products
Vendor Product Version
Vivotek SD9364 Affected: VVTK-0103f
Create a notification for this product.
Credits
jylsec (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:vivotek:sd9364_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sd9364_firmware",
            "vendor": "vivotek",
            "versions": [
              {
                "status": "affected",
                "version": "vvtk-0103f"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7441",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-07T16:17:09.130706Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-07T16:24:42.771Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "httpd"
          ],
          "product": "SD9364",
          "vendor": "Vivotek",
          "versions": [
            {
              "status": "affected",
              "version": "VVTK-0103f"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jylsec (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
        },
        {
          "lang": "de",
          "value": "In Vivotek SD9364 VVTK-0103f wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Das betrifft die Funktion read der Komponente httpd. Dank der Manipulation des Arguments Content-Length mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-03T17:31:04.573Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-273526 | Vivotek SD9364 httpd read stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.273526"
        },
        {
          "name": "VDB-273526 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.273526"
        },
        {
          "name": "Submit #383842 | vivotek SD9364 VVTK-0103f buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.383842"
        },
        {
          "tags": [
            "broken-link",
            "exploit"
          ],
          "url": "https://yjz233.notion.site/vivotek-SD9364-has-stack-buffer-overflow-vulnerability-in-httpd-c9dabd0511d04093865d1d75110429d1?pvs=4"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-02T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-02T23:46:19.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Vivotek SD9364 httpd read stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7441",
    "datePublished": "2024-08-03T17:31:04.573Z",
    "dateReserved": "2024-08-02T21:36:37.042Z",
    "dateUpdated": "2024-08-07T16:24:42.771Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-7442 (GCVE-0-2024-7442)

Vulnerability from nvd – Published: 2024-08-03 18:00 – Updated: 2024-08-05 15:04
VLAI?
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
CWE
Assigner
References
https://vuldb.com/?id.273527 vdb-entrytechnical-description
https://vuldb.com/?ctiid.273527 signaturepermissions-required
https://vuldb.com/?submit.383843 third-party-advisory
https://yjz233.notion.site/vivotek-SD9364-has-com… broken-link
Impacted products
Vendor Product Version
Vivotek SD9364 Affected: VVTK-0103f
Create a notification for this product.
Credits
jylsec (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7442",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-05T15:04:20.396388Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:04:43.133Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SD9364",
          "vendor": "Vivotek",
          "versions": [
            {
              "status": "affected",
              "version": "VVTK-0103f"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jylsec (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Vivotek SD9364 VVTK-0103f ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion getenv der Datei upload_file.cgi. Dank Manipulation des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-03T18:00:09.890Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-273527 | Vivotek SD9364 upload_file.cgi getenv command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.273527"
        },
        {
          "name": "VDB-273527 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.273527"
        },
        {
          "name": "Submit #383843 | vivotek SD9364 VVTK-0103f command injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.383843"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://yjz233.notion.site/vivotek-SD9364-has-command-injection-vulnerability-in-upload_file-cgi-5cef6da27b25479497dda0b73670f565?pvs=4"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-02T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-02T23:46:16.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Vivotek SD9364 upload_file.cgi getenv command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7442",
    "datePublished": "2024-08-03T18:00:09.890Z",
    "dateReserved": "2024-08-02T21:36:40.547Z",
    "dateUpdated": "2024-08-05T15:04:43.133Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-7441 (GCVE-0-2024-7441)

Vulnerability from nvd – Published: 2024-08-03 17:31 – Updated: 2024-08-07 16:24
VLAI?
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
https://vuldb.com/?id.273526 vdb-entrytechnical-description
https://vuldb.com/?ctiid.273526 signaturepermissions-required
https://vuldb.com/?submit.383842 third-party-advisory
https://yjz233.notion.site/vivotek-SD9364-has-sta… broken-linkexploit
Impacted products
Vendor Product Version
Vivotek SD9364 Affected: VVTK-0103f
Create a notification for this product.
Credits
jylsec (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:vivotek:sd9364_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sd9364_firmware",
            "vendor": "vivotek",
            "versions": [
              {
                "status": "affected",
                "version": "vvtk-0103f"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7441",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-07T16:17:09.130706Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-07T16:24:42.771Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "httpd"
          ],
          "product": "SD9364",
          "vendor": "Vivotek",
          "versions": [
            {
              "status": "affected",
              "version": "VVTK-0103f"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jylsec (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
        },
        {
          "lang": "de",
          "value": "In Vivotek SD9364 VVTK-0103f wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Das betrifft die Funktion read der Komponente httpd. Dank der Manipulation des Arguments Content-Length mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-03T17:31:04.573Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-273526 | Vivotek SD9364 httpd read stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.273526"
        },
        {
          "name": "VDB-273526 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.273526"
        },
        {
          "name": "Submit #383842 | vivotek SD9364 VVTK-0103f buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.383842"
        },
        {
          "tags": [
            "broken-link",
            "exploit"
          ],
          "url": "https://yjz233.notion.site/vivotek-SD9364-has-stack-buffer-overflow-vulnerability-in-httpd-c9dabd0511d04093865d1d75110429d1?pvs=4"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-02T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-02T23:46:19.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Vivotek SD9364 httpd read stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7441",
    "datePublished": "2024-08-03T17:31:04.573Z",
    "dateReserved": "2024-08-02T21:36:37.042Z",
    "dateUpdated": "2024-08-07T16:24:42.771Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}