CVE-2023-27520 (GCVE-0-2023-27520)
Vulnerability from cvelistv5 – Published: 2023-04-11 00:00 – Updated: 2025-02-10 21:27
VLAI?
Summary
Cross-site request forgery (CSRF) vulnerability in SEIKO EPSON printers/network interface Web Config allows a remote unauthenticated attacker to hijack the authentication and perform unintended operations by having a logged-in user view a malicious page. [Note] Web Config is the software that allows users to check the status and change the settings of SEIKO EPSON printers/network interface via a web browser. According to SEIKO EPSON CORPORATION, it is also called as Remote Manager in some products. Web Config is pre-installed in some printers/network interface provided by SEIKO EPSON CORPORATION. For the details of the affected product names/model numbers, refer to the information provided by the vendor.
Severity ?
6.5 (Medium)
CWE
- Cross-site request forgery
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| SEIKO EPSON CORPORATION | SEIKO EPSON printers/network interface Web Config |
Affected:
unspecified
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:16:35.577Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.epson.jp/support/misc_t/230308_oshirase.htm"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/jp/JVN82424996/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-27520",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:27:03.425152Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352 Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:27:09.702Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SEIKO EPSON printers/network interface Web Config",
"vendor": "SEIKO EPSON CORPORATION",
"versions": [
{
"status": "affected",
"version": "unspecified"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability in SEIKO EPSON printers/network interface Web Config allows a remote unauthenticated attacker to hijack the authentication and perform unintended operations by having a logged-in user view a malicious page. [Note] Web Config is the software that allows users to check the status and change the settings of SEIKO EPSON printers/network interface via a web browser. According to SEIKO EPSON CORPORATION, it is also called as Remote Manager in some products. Web Config is pre-installed in some printers/network interface provided by SEIKO EPSON CORPORATION. For the details of the affected product names/model numbers, refer to the information provided by the vendor."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Cross-site request forgery",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T00:00:00.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.epson.jp/support/misc_t/230308_oshirase.htm"
},
{
"url": "https://jvn.jp/en/jp/JVN82424996/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-27520",
"datePublished": "2023-04-11T00:00:00.000Z",
"dateReserved": "2023-03-02T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:27:09.702Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-23572 (GCVE-0-2023-23572)
Vulnerability from cvelistv5 – Published: 2023-04-11 00:00 – Updated: 2025-02-11 15:51
VLAI?
Summary
Cross-site scripting vulnerability in SEIKO EPSON printers/network interface Web Config allows a remote authenticated attacker with an administrative privilege to inject an arbitrary script. [Note] Web Config is the software that allows users to check the status and change the settings of SEIKO EPSON printers/network interface via a web browser. According to SEIKO EPSON CORPORATION, it is also called as Remote Manager in some products. Web Config is pre-installed in some printers/network interface provided by SEIKO EPSON CORPORATION. For the details of the affected product names/model numbers, refer to the information provided by the vendor.
Severity ?
4.8 (Medium)
CWE
- Cross-site scripting
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| SEIKO EPSON CORPORATION | SEIKO EPSON printers/network interface Web Config |
Affected:
unspecified
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:35:33.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.epson.jp/support/misc_t/230308_oshirase.htm"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/jp/JVN82424996/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-23572",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-11T15:50:11.024574Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-11T15:51:26.574Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SEIKO EPSON printers/network interface Web Config",
"vendor": "SEIKO EPSON CORPORATION",
"versions": [
{
"status": "affected",
"version": "unspecified"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting vulnerability in SEIKO EPSON printers/network interface Web Config allows a remote authenticated attacker with an administrative privilege to inject an arbitrary script. [Note] Web Config is the software that allows users to check the status and change the settings of SEIKO EPSON printers/network interface via a web browser. According to SEIKO EPSON CORPORATION, it is also called as Remote Manager in some products. Web Config is pre-installed in some printers/network interface provided by SEIKO EPSON CORPORATION. For the details of the affected product names/model numbers, refer to the information provided by the vendor."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Cross-site scripting",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T00:00:00.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.epson.jp/support/misc_t/230308_oshirase.htm"
},
{
"url": "https://jvn.jp/en/jp/JVN82424996/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-23572",
"datePublished": "2023-04-11T00:00:00.000Z",
"dateReserved": "2023-03-02T00:00:00.000Z",
"dateUpdated": "2025-02-11T15:51:26.574Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-27520 (GCVE-0-2023-27520)
Vulnerability from nvd – Published: 2023-04-11 00:00 – Updated: 2025-02-10 21:27
VLAI?
Summary
Cross-site request forgery (CSRF) vulnerability in SEIKO EPSON printers/network interface Web Config allows a remote unauthenticated attacker to hijack the authentication and perform unintended operations by having a logged-in user view a malicious page. [Note] Web Config is the software that allows users to check the status and change the settings of SEIKO EPSON printers/network interface via a web browser. According to SEIKO EPSON CORPORATION, it is also called as Remote Manager in some products. Web Config is pre-installed in some printers/network interface provided by SEIKO EPSON CORPORATION. For the details of the affected product names/model numbers, refer to the information provided by the vendor.
Severity ?
6.5 (Medium)
CWE
- Cross-site request forgery
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| SEIKO EPSON CORPORATION | SEIKO EPSON printers/network interface Web Config |
Affected:
unspecified
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:16:35.577Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.epson.jp/support/misc_t/230308_oshirase.htm"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/jp/JVN82424996/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-27520",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:27:03.425152Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352 Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:27:09.702Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SEIKO EPSON printers/network interface Web Config",
"vendor": "SEIKO EPSON CORPORATION",
"versions": [
{
"status": "affected",
"version": "unspecified"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability in SEIKO EPSON printers/network interface Web Config allows a remote unauthenticated attacker to hijack the authentication and perform unintended operations by having a logged-in user view a malicious page. [Note] Web Config is the software that allows users to check the status and change the settings of SEIKO EPSON printers/network interface via a web browser. According to SEIKO EPSON CORPORATION, it is also called as Remote Manager in some products. Web Config is pre-installed in some printers/network interface provided by SEIKO EPSON CORPORATION. For the details of the affected product names/model numbers, refer to the information provided by the vendor."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Cross-site request forgery",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T00:00:00.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.epson.jp/support/misc_t/230308_oshirase.htm"
},
{
"url": "https://jvn.jp/en/jp/JVN82424996/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-27520",
"datePublished": "2023-04-11T00:00:00.000Z",
"dateReserved": "2023-03-02T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:27:09.702Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-23572 (GCVE-0-2023-23572)
Vulnerability from nvd – Published: 2023-04-11 00:00 – Updated: 2025-02-11 15:51
VLAI?
Summary
Cross-site scripting vulnerability in SEIKO EPSON printers/network interface Web Config allows a remote authenticated attacker with an administrative privilege to inject an arbitrary script. [Note] Web Config is the software that allows users to check the status and change the settings of SEIKO EPSON printers/network interface via a web browser. According to SEIKO EPSON CORPORATION, it is also called as Remote Manager in some products. Web Config is pre-installed in some printers/network interface provided by SEIKO EPSON CORPORATION. For the details of the affected product names/model numbers, refer to the information provided by the vendor.
Severity ?
4.8 (Medium)
CWE
- Cross-site scripting
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| SEIKO EPSON CORPORATION | SEIKO EPSON printers/network interface Web Config |
Affected:
unspecified
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:35:33.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.epson.jp/support/misc_t/230308_oshirase.htm"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/jp/JVN82424996/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-23572",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-11T15:50:11.024574Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-11T15:51:26.574Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SEIKO EPSON printers/network interface Web Config",
"vendor": "SEIKO EPSON CORPORATION",
"versions": [
{
"status": "affected",
"version": "unspecified"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting vulnerability in SEIKO EPSON printers/network interface Web Config allows a remote authenticated attacker with an administrative privilege to inject an arbitrary script. [Note] Web Config is the software that allows users to check the status and change the settings of SEIKO EPSON printers/network interface via a web browser. According to SEIKO EPSON CORPORATION, it is also called as Remote Manager in some products. Web Config is pre-installed in some printers/network interface provided by SEIKO EPSON CORPORATION. For the details of the affected product names/model numbers, refer to the information provided by the vendor."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Cross-site scripting",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T00:00:00.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.epson.jp/support/misc_t/230308_oshirase.htm"
},
{
"url": "https://jvn.jp/en/jp/JVN82424996/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-23572",
"datePublished": "2023-04-11T00:00:00.000Z",
"dateReserved": "2023-03-02T00:00:00.000Z",
"dateUpdated": "2025-02-11T15:51:26.574Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}