CVE-2023-31166 (GCVE-0-2023-31166)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:25 – Updated: 2025-01-24 19:28
VLAI?
Title
Improper Limitation of a Pathname to a Restricted Directory
Summary
An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of the file system. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R126-V0 , < R150-V2 (custom)
Affected: R126-V0 , < R149-V4 (custom)
Affected: R126-V0 , < R148-V7 (custom)
Affected: R126-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R126-V0 , < R150-V2 (custom)
Affected: R126-V0 , < R149-V4 (custom)
Affected: R126-V0 , < R148-V7 (custom)
Affected: R126-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R126-V0 , < R150-V2 (custom)
Affected: R126-V0 , < R149-V4 (custom)
Affected: R126-V0 , < R148-V7 (custom)
Affected: R126-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R126-V0 , < R150-V2 (custom)
Affected: R126-V0 , < R149-V4 (custom)
Affected: R126-V0 , < R148-V7 (custom)
Affected: R126-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.866Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31166",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:28:10.395795Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:28:19.480Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of the file system.\u003cbr\u003e\u003cbr\u003eSee SEL Service Bulletin dated 2022-11-15 for more details."
            }
          ],
          "value": "An Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of the file system.\n\nSee SEL Service Bulletin dated 2022-11-15 for more details."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-643",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-643 Identify Shared Files/Directories on System"
            }
          ]
        },
        {
          "capecId": "CAPEC-176",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-176 Configuration/Environment Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:25:59.606Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Limitation of a Pathname to a Restricted Directory",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31166",
    "datePublished": "2023-05-10T19:25:59.606Z",
    "dateReserved": "2023-04-24T23:19:33.137Z",
    "dateUpdated": "2025-01-24T19:28:19.480Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31165 (GCVE-0-2023-31165)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:25 – Updated: 2025-01-24 19:27
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R119-V0 , < R150-V2 (custom)
Affected: R119-V0 , < R149-V4 (custom)
Affected: R119-V0 , < R148-V7 (custom)
Affected: R119-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R100-V0 , < R150-V2 (custom)
Affected: R100-V0 , < R149-V4 (custom)
Affected: R100-V0 , < R148-V7 (custom)
Affected: R100-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R108-V0 , < R150-V2 (custom)
Affected: R108-V0 , < R149-V4 (custom)
Affected: R108-V0 , < R148-V7 (custom)
Affected: R108-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R113-V0 , < R150-V2 (custom)
Affected: R113-V0 , < R149-V4 (custom)
Affected: R113-V0 , < R148-V7 (custom)
Affected: R113-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.790Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31165",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:27:51.348037Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:27:55.295Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003cbr\u003e\u003cdiv\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003c/div\u003e\u003c/div\u003e\n\n"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:25:34.186Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31165",
    "datePublished": "2023-05-10T19:25:34.186Z",
    "dateReserved": "2023-04-24T23:19:33.137Z",
    "dateUpdated": "2025-01-24T19:27:55.295Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31164 (GCVE-0-2023-31164)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:25 – Updated: 2025-01-24 19:27
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R119-V0 , < R150-V2 (custom)
Affected: R119-V0 , < R149-V4 (custom)
Affected: R119-V0 , < R148-V7 (custom)
Affected: R119-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R100-V0 , < R150-V2 (custom)
Affected: R100-V0 , < R149-V4 (custom)
Affected: R100-V0 , < R148-V7 (custom)
Affected: R100-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R108-V0 , < R150-V2 (custom)
Affected: R108-V0 , < R149-V4 (custom)
Affected: R108-V0 , < R148-V7 (custom)
Affected: R108-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R113-V0 , < R150-V2 (custom)
Affected: R113-V0 , < R149-V4 (custom)
Affected: R113-V0 , < R148-V7 (custom)
Affected: R113-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.764Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31164",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:27:36.186170Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:27:38.573Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003cbr\u003e\u003cdiv\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003c/div\u003e\u003c/div\u003e\n\n"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:25:16.534Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31164",
    "datePublished": "2023-05-10T19:25:16.534Z",
    "dateReserved": "2023-04-24T23:19:33.137Z",
    "dateUpdated": "2025-01-24T19:27:38.573Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31163 (GCVE-0-2023-31163)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:24 – Updated: 2025-01-24 19:27
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R119-V0 , < R150-V2 (custom)
Affected: R119-V0 , < R149-V4 (custom)
Affected: R119-V0 , < R148-V7 (custom)
Affected: R119-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R100-V0 , < R150-V2 (custom)
Affected: R100-V0 , < R149-V4 (custom)
Affected: R100-V0 , < R148-V7 (custom)
Affected: R100-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R108-V0 , < R150-V2 (custom)
Affected: R108-V0 , < R149-V4 (custom)
Affected: R108-V0 , < R148-V7 (custom)
Affected: R108-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R113-V0 , < R150-V2 (custom)
Affected: R113-V0 , < R149-V4 (custom)
Affected: R113-V0 , < R148-V7 (custom)
Affected: R113-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.738Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31163",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:27:10.625855Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:27:13.760Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003cbr\u003e\u003cdiv\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003c/div\u003e\u003c/div\u003e\n\n"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:24:45.965Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31163",
    "datePublished": "2023-05-10T19:24:45.965Z",
    "dateReserved": "2023-04-24T23:19:33.136Z",
    "dateUpdated": "2025-01-24T19:27:13.760Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31162 (GCVE-0-2023-31162)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:24 – Updated: 2025-01-24 19:26
VLAI?
Title
Improper Input Validation in Web Interface
Summary
An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to arbitrarily alter the content of a configuration file. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-20 - Improper Input Validation
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.773Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31162",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:26:51.589571Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:26:55.712Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to arbitrarily alter the content of a configuration file.\u003cbr\u003e\u003cbr\u003eSee SEL Service Bulletin dated 2022-11-15 for more details."
            }
          ],
          "value": "An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to arbitrarily alter the content of a configuration file.\n\nSee SEL Service Bulletin dated 2022-11-15 for more details."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-176",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-176 Configuration/Environment Manipulation"
            }
          ]
        },
        {
          "capecId": "CAPEC-275",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-275 DNS Rebinding"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:N/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:24:20.480Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Input Validation in Web Interface",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31162",
    "datePublished": "2023-05-10T19:24:20.480Z",
    "dateReserved": "2023-04-24T23:19:33.136Z",
    "dateUpdated": "2025-01-24T19:26:55.712Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31160 (GCVE-0-2023-31160)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:23 – Updated: 2025-01-24 19:19
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.879Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31160",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:19:22.925031Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:19:25.906Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:23:43.200Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31160",
    "datePublished": "2023-05-10T19:23:43.200Z",
    "dateReserved": "2023-04-24T23:19:33.136Z",
    "dateUpdated": "2025-01-24T19:19:25.906Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31159 (GCVE-0-2023-31159)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:23 – Updated: 2025-01-24 19:10
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.784Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31159",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:10:03.615553Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:10:07.456Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:23:29.182Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31159",
    "datePublished": "2023-05-10T19:23:29.182Z",
    "dateReserved": "2023-04-24T23:19:33.136Z",
    "dateUpdated": "2025-01-24T19:10:07.456Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31158 (GCVE-0-2023-31158)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:23 – Updated: 2025-01-24 19:09
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.809Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31158",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:09:44.725784Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:09:47.546Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:23:15.171Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31158",
    "datePublished": "2023-05-10T19:23:15.171Z",
    "dateReserved": "2023-04-24T23:19:33.136Z",
    "dateUpdated": "2025-01-24T19:09:47.546Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31157 (GCVE-0-2023-31157)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:22 – Updated: 2025-01-24 19:09
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.689Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31157",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:09:17.571361Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:09:33.094Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:22:58.877Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31157",
    "datePublished": "2023-05-10T19:22:58.877Z",
    "dateReserved": "2023-04-24T23:19:04.959Z",
    "dateUpdated": "2025-01-24T19:09:33.094Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31156 (GCVE-0-2023-31156)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:22 – Updated: 2025-01-24 19:08
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.890Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31156",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:08:45.763598Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:08:49.377Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:22:44.225Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31156",
    "datePublished": "2023-05-10T19:22:44.225Z",
    "dateReserved": "2023-04-24T23:19:04.959Z",
    "dateUpdated": "2025-01-24T19:08:49.377Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31155 (GCVE-0-2023-31155)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:22 – Updated: 2025-01-24 19:05
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.765Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31155",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:05:37.935719Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:05:41.753Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:22:32.651Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31155",
    "datePublished": "2023-05-10T19:22:32.651Z",
    "dateReserved": "2023-04-24T23:19:04.959Z",
    "dateUpdated": "2025-01-24T19:05:41.753Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31154 (GCVE-0-2023-31154)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:22 – Updated: 2025-01-24 19:05
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.675Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31154",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:05:17.174236Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:05:24.335Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:22:18.749Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31154",
    "datePublished": "2023-05-10T19:22:18.749Z",
    "dateReserved": "2023-04-24T23:19:04.958Z",
    "dateUpdated": "2025-01-24T19:05:24.335Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31153 (GCVE-0-2023-31153)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:22 – Updated: 2025-01-24 19:05
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R119-V0 , < R150-V2 (custom)
Affected: R119-V0 , < R149-V4 (custom)
Affected: R119-V0 , < R148-V7 (custom)
Affected: R119-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R109-V0 , < R150-V2 (custom)
Affected: R109-V0 , < R149-V4 (custom)
Affected: R109-V0 , < R148-V7 (custom)
Affected: R109-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R109-V0 , < R150-V2 (custom)
Affected: R109-V0 , < R149-V4 (custom)
Affected: R109-V0 , < R148-V7 (custom)
Affected: R109-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R113-V0 , < R150-V2 (custom)
Affected: R113-V0 , < R149-V4 (custom)
Affected: R113-V0 , < R148-V7 (custom)
Affected: R113-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.706Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31153",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:04:43.531419Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:05:05.448Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the\u0026nbsp;\u003cspan style=\"background-color: var(--wht);\"\u003eSchweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/span\u003e\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003c/span\u003e\n\n\u003c/p\u003e"
            }
          ],
          "value": "An Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the\u00a0Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.See SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:22:06.307Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31153",
    "datePublished": "2023-05-10T19:22:06.307Z",
    "dateReserved": "2023-04-24T23:19:04.958Z",
    "dateUpdated": "2025-01-24T19:05:05.448Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31152 (GCVE-0-2023-31152)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:21 – Updated: 2025-01-24 19:04
VLAI?
Title
Authentication Bypass Using an Alternate Path or Channel
Summary
An Authentication Bypass Using an Alternate Path or Channel vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface allows Authentication Bypass. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.728Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31152",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:04:22.247927Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:04:25.192Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Authentication Bypass Using an Alternate Path or Channel vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface allows Authentication Bypass. \u003cbr\u003e\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003c/span\u003e\n\n\u003c/p\u003e"
            }
          ],
          "value": "An Authentication Bypass Using an Alternate Path or Channel vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface allows Authentication Bypass. \nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-288",
              "description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:21:50.029Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Authentication Bypass Using an Alternate Path or Channel",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31152",
    "datePublished": "2023-05-10T19:21:50.029Z",
    "dateReserved": "2023-04-24T23:19:04.957Z",
    "dateUpdated": "2025-01-24T19:04:25.192Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31151 (GCVE-0-2023-31151)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:21 – Updated: 2025-01-24 19:04
VLAI?
Title
Improper Certificate Validation
Summary
An Improper Certificate Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote unauthenticated attacker to conduct a man-in-the-middle (MitM) attack. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-295 - Improper Certificate Validation
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.853Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31151",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:04:00.595043Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:04:04.464Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Improper Certificate Validation vulnerability \n\nin the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface\n\ncould allow a remote unauthenticated attacker to conduct a man-in-the-middle (MitM) attack.\u003cbr\u003e\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "An Improper Certificate Validation vulnerability \n\nin the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface\n\ncould allow a remote unauthenticated attacker to conduct a man-in-the-middle (MitM) attack.\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-94",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-94 Man in the Middle Attack"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-295",
              "description": "CWE-295 Improper Certificate Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:21:30.649Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Certificate Validation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31151",
    "datePublished": "2023-05-10T19:21:30.649Z",
    "dateReserved": "2023-04-24T23:19:04.957Z",
    "dateUpdated": "2025-01-24T19:04:04.464Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31166 (GCVE-0-2023-31166)

Vulnerability from nvd – Published: 2023-05-10 19:25 – Updated: 2025-01-24 19:28
VLAI?
Title
Improper Limitation of a Pathname to a Restricted Directory
Summary
An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of the file system. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R126-V0 , < R150-V2 (custom)
Affected: R126-V0 , < R149-V4 (custom)
Affected: R126-V0 , < R148-V7 (custom)
Affected: R126-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R126-V0 , < R150-V2 (custom)
Affected: R126-V0 , < R149-V4 (custom)
Affected: R126-V0 , < R148-V7 (custom)
Affected: R126-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R126-V0 , < R150-V2 (custom)
Affected: R126-V0 , < R149-V4 (custom)
Affected: R126-V0 , < R148-V7 (custom)
Affected: R126-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R126-V0 , < R150-V2 (custom)
Affected: R126-V0 , < R149-V4 (custom)
Affected: R126-V0 , < R148-V7 (custom)
Affected: R126-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.866Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31166",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:28:10.395795Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:28:19.480Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of the file system.\u003cbr\u003e\u003cbr\u003eSee SEL Service Bulletin dated 2022-11-15 for more details."
            }
          ],
          "value": "An Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of the file system.\n\nSee SEL Service Bulletin dated 2022-11-15 for more details."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-643",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-643 Identify Shared Files/Directories on System"
            }
          ]
        },
        {
          "capecId": "CAPEC-176",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-176 Configuration/Environment Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:25:59.606Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Limitation of a Pathname to a Restricted Directory",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31166",
    "datePublished": "2023-05-10T19:25:59.606Z",
    "dateReserved": "2023-04-24T23:19:33.137Z",
    "dateUpdated": "2025-01-24T19:28:19.480Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31165 (GCVE-0-2023-31165)

Vulnerability from nvd – Published: 2023-05-10 19:25 – Updated: 2025-01-24 19:27
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R119-V0 , < R150-V2 (custom)
Affected: R119-V0 , < R149-V4 (custom)
Affected: R119-V0 , < R148-V7 (custom)
Affected: R119-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R100-V0 , < R150-V2 (custom)
Affected: R100-V0 , < R149-V4 (custom)
Affected: R100-V0 , < R148-V7 (custom)
Affected: R100-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R108-V0 , < R150-V2 (custom)
Affected: R108-V0 , < R149-V4 (custom)
Affected: R108-V0 , < R148-V7 (custom)
Affected: R108-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R113-V0 , < R150-V2 (custom)
Affected: R113-V0 , < R149-V4 (custom)
Affected: R113-V0 , < R148-V7 (custom)
Affected: R113-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.790Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31165",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:27:51.348037Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:27:55.295Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003cbr\u003e\u003cdiv\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003c/div\u003e\u003c/div\u003e\n\n"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:25:34.186Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31165",
    "datePublished": "2023-05-10T19:25:34.186Z",
    "dateReserved": "2023-04-24T23:19:33.137Z",
    "dateUpdated": "2025-01-24T19:27:55.295Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31164 (GCVE-0-2023-31164)

Vulnerability from nvd – Published: 2023-05-10 19:25 – Updated: 2025-01-24 19:27
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R119-V0 , < R150-V2 (custom)
Affected: R119-V0 , < R149-V4 (custom)
Affected: R119-V0 , < R148-V7 (custom)
Affected: R119-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R100-V0 , < R150-V2 (custom)
Affected: R100-V0 , < R149-V4 (custom)
Affected: R100-V0 , < R148-V7 (custom)
Affected: R100-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R108-V0 , < R150-V2 (custom)
Affected: R108-V0 , < R149-V4 (custom)
Affected: R108-V0 , < R148-V7 (custom)
Affected: R108-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R113-V0 , < R150-V2 (custom)
Affected: R113-V0 , < R149-V4 (custom)
Affected: R113-V0 , < R148-V7 (custom)
Affected: R113-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.764Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31164",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:27:36.186170Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:27:38.573Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003cbr\u003e\u003cdiv\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003c/div\u003e\u003c/div\u003e\n\n"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:25:16.534Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31164",
    "datePublished": "2023-05-10T19:25:16.534Z",
    "dateReserved": "2023-04-24T23:19:33.137Z",
    "dateUpdated": "2025-01-24T19:27:38.573Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31163 (GCVE-0-2023-31163)

Vulnerability from nvd – Published: 2023-05-10 19:24 – Updated: 2025-01-24 19:27
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R119-V0 , < R150-V2 (custom)
Affected: R119-V0 , < R149-V4 (custom)
Affected: R119-V0 , < R148-V7 (custom)
Affected: R119-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R100-V0 , < R150-V2 (custom)
Affected: R100-V0 , < R149-V4 (custom)
Affected: R100-V0 , < R148-V7 (custom)
Affected: R100-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R108-V0 , < R150-V2 (custom)
Affected: R108-V0 , < R149-V4 (custom)
Affected: R108-V0 , < R148-V7 (custom)
Affected: R108-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R113-V0 , < R150-V2 (custom)
Affected: R113-V0 , < R149-V4 (custom)
Affected: R113-V0 , < R148-V7 (custom)
Affected: R113-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.738Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31163",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:27:10.625855Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:27:13.760Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003cbr\u003e\u003cdiv\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003c/div\u003e\u003c/div\u003e\n\n"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:24:45.965Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31163",
    "datePublished": "2023-05-10T19:24:45.965Z",
    "dateReserved": "2023-04-24T23:19:33.136Z",
    "dateUpdated": "2025-01-24T19:27:13.760Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31162 (GCVE-0-2023-31162)

Vulnerability from nvd – Published: 2023-05-10 19:24 – Updated: 2025-01-24 19:26
VLAI?
Title
Improper Input Validation in Web Interface
Summary
An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to arbitrarily alter the content of a configuration file. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-20 - Improper Input Validation
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R149-V0 , < R150-V2 (custom)
Affected: R149-V0 , < R149-V4 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.773Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31162",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:26:51.589571Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:26:55.712Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R149-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to arbitrarily alter the content of a configuration file.\u003cbr\u003e\u003cbr\u003eSee SEL Service Bulletin dated 2022-11-15 for more details."
            }
          ],
          "value": "An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to arbitrarily alter the content of a configuration file.\n\nSee SEL Service Bulletin dated 2022-11-15 for more details."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-176",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-176 Configuration/Environment Manipulation"
            }
          ]
        },
        {
          "capecId": "CAPEC-275",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-275 DNS Rebinding"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:N/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:24:20.480Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Input Validation in Web Interface",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31162",
    "datePublished": "2023-05-10T19:24:20.480Z",
    "dateReserved": "2023-04-24T23:19:33.136Z",
    "dateUpdated": "2025-01-24T19:26:55.712Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31160 (GCVE-0-2023-31160)

Vulnerability from nvd – Published: 2023-05-10 19:23 – Updated: 2025-01-24 19:19
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.879Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31160",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:19:22.925031Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:19:25.906Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:23:43.200Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31160",
    "datePublished": "2023-05-10T19:23:43.200Z",
    "dateReserved": "2023-04-24T23:19:33.136Z",
    "dateUpdated": "2025-01-24T19:19:25.906Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31159 (GCVE-0-2023-31159)

Vulnerability from nvd – Published: 2023-05-10 19:23 – Updated: 2025-01-24 19:10
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.784Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31159",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:10:03.615553Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:10:07.456Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:23:29.182Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31159",
    "datePublished": "2023-05-10T19:23:29.182Z",
    "dateReserved": "2023-04-24T23:19:33.136Z",
    "dateUpdated": "2025-01-24T19:10:07.456Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31158 (GCVE-0-2023-31158)

Vulnerability from nvd – Published: 2023-05-10 19:23 – Updated: 2025-01-24 19:09
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.809Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31158",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:09:44.725784Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:09:47.546Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:23:15.171Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31158",
    "datePublished": "2023-05-10T19:23:15.171Z",
    "dateReserved": "2023-04-24T23:19:33.136Z",
    "dateUpdated": "2025-01-24T19:09:47.546Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31157 (GCVE-0-2023-31157)

Vulnerability from nvd – Published: 2023-05-10 19:22 – Updated: 2025-01-24 19:09
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.689Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31157",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:09:17.571361Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:09:33.094Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:22:58.877Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31157",
    "datePublished": "2023-05-10T19:22:58.877Z",
    "dateReserved": "2023-04-24T23:19:04.959Z",
    "dateUpdated": "2025-01-24T19:09:33.094Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31156 (GCVE-0-2023-31156)

Vulnerability from nvd – Published: 2023-05-10 19:22 – Updated: 2025-01-24 19:08
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.890Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31156",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:08:45.763598Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:08:49.377Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:22:44.225Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31156",
    "datePublished": "2023-05-10T19:22:44.225Z",
    "dateReserved": "2023-04-24T23:19:04.959Z",
    "dateUpdated": "2025-01-24T19:08:49.377Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31155 (GCVE-0-2023-31155)

Vulnerability from nvd – Published: 2023-05-10 19:22 – Updated: 2025-01-24 19:05
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.765Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31155",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:05:37.935719Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:05:41.753Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:22:32.651Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31155",
    "datePublished": "2023-05-10T19:22:32.651Z",
    "dateReserved": "2023-04-24T23:19:04.959Z",
    "dateUpdated": "2025-01-24T19:05:41.753Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31154 (GCVE-0-2023-31154)

Vulnerability from nvd – Published: 2023-05-10 19:22 – Updated: 2025-01-24 19:05
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.675Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31154",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:05:17.174236Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:05:24.335Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:22:18.749Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31154",
    "datePublished": "2023-05-10T19:22:18.749Z",
    "dateReserved": "2023-04-24T23:19:04.958Z",
    "dateUpdated": "2025-01-24T19:05:24.335Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31153 (GCVE-0-2023-31153)

Vulnerability from nvd – Published: 2023-05-10 19:22 – Updated: 2025-01-24 19:05
VLAI?
Title
Improper Neutralization of Input During Web Page Generation
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R119-V0 , < R150-V2 (custom)
Affected: R119-V0 , < R149-V4 (custom)
Affected: R119-V0 , < R148-V7 (custom)
Affected: R119-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R109-V0 , < R150-V2 (custom)
Affected: R109-V0 , < R149-V4 (custom)
Affected: R109-V0 , < R148-V7 (custom)
Affected: R109-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R109-V0 , < R150-V2 (custom)
Affected: R109-V0 , < R149-V4 (custom)
Affected: R109-V0 , < R148-V7 (custom)
Affected: R109-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R113-V0 , < R150-V2 (custom)
Affected: R113-V0 , < R149-V4 (custom)
Affected: R113-V0 , < R148-V7 (custom)
Affected: R113-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.706Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31153",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:04:43.531419Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:05:05.448Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R109-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the\u0026nbsp;\u003cspan style=\"background-color: var(--wht);\"\u003eSchweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/span\u003e\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003c/span\u003e\n\n\u003c/p\u003e"
            }
          ],
          "value": "An Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the\u00a0Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.See SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:22:06.307Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31153",
    "datePublished": "2023-05-10T19:22:06.307Z",
    "dateReserved": "2023-04-24T23:19:04.958Z",
    "dateUpdated": "2025-01-24T19:05:05.448Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31152 (GCVE-0-2023-31152)

Vulnerability from nvd – Published: 2023-05-10 19:21 – Updated: 2025-01-24 19:04
VLAI?
Title
Authentication Bypass Using an Alternate Path or Channel
Summary
An Authentication Bypass Using an Alternate Path or Channel vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface allows Authentication Bypass. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.728Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31152",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:04:22.247927Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:04:25.192Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Authentication Bypass Using an Alternate Path or Channel vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface allows Authentication Bypass. \u003cbr\u003e\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003c/span\u003e\n\n\u003c/p\u003e"
            }
          ],
          "value": "An Authentication Bypass Using an Alternate Path or Channel vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface allows Authentication Bypass. \nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-288",
              "description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:21:50.029Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Authentication Bypass Using an Alternate Path or Channel",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31152",
    "datePublished": "2023-05-10T19:21:50.029Z",
    "dateReserved": "2023-04-24T23:19:04.957Z",
    "dateUpdated": "2025-01-24T19:04:25.192Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31151 (GCVE-0-2023-31151)

Vulnerability from nvd – Published: 2023-05-10 19:21 – Updated: 2025-01-24 19:04
VLAI?
Title
Improper Certificate Validation
Summary
An Improper Certificate Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote unauthenticated attacker to conduct a man-in-the-middle (MitM) attack. See SEL Service Bulletin dated 2022-11-15 for more details.
CWE
  • CWE-295 - Improper Certificate Validation
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3505-3 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3530-4 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3532 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3555 Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560S Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3560E Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-2241 RTAC module Affected: R147-V0 , < R150-V2 (custom)
Affected: R147-V0 , < R149-V4 (custom)
Affected: R147-V0 , < R148-V7 (custom)
Affected: R147-V0 , < R147-V6 (custom)
Create a notification for this product.
    Schweitzer Engineering Laboratories SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
Create a notification for this product.
Credits
Andrea Palanca, Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.853Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31151",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:04:00.595043Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:04:04.464Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R147-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Improper Certificate Validation vulnerability \n\nin the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface\n\ncould allow a remote unauthenticated attacker to conduct a man-in-the-middle (MitM) attack.\u003cbr\u003e\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "An Improper Certificate Validation vulnerability \n\nin the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface\n\ncould allow a remote unauthenticated attacker to conduct a man-in-the-middle (MitM) attack.\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-94",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-94 Man in the Middle Attack"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-295",
              "description": "CWE-295 Improper Certificate Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:21:30.649Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Certificate Validation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31151",
    "datePublished": "2023-05-10T19:21:30.649Z",
    "dateReserved": "2023-04-24T23:19:04.957Z",
    "dateUpdated": "2025-01-24T19:04:04.464Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}