Search criteria
18 vulnerabilities found for SIGMA Spectrum Infusion System by Baxter
VAR-201903-0661
Vulnerability from variot - Updated: 2023-12-18 12:28Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes. Baxter SIGMA Spectrum Infusion System Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Baxter Wireless Battery Module (WBM) is prone to multiple security vulnerabilities. Attackers may exploit these issues to gain unauthorized access, obtain sensitive information, or bypass the authentication mechanism and gain access to the vulnerable device. Baxter SIGMA Spectrum Infusion System is an intelligent infusion system developed by Baxter, USA. A security vulnerability exists in Baxter WBM
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201903-0661",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 1.0,
"vendor": "baxter",
"version": "6.05"
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 0.8,
"vendor": "baxter",
"version": "6.05 (model 35700bax)"
},
{
"model": "wireless battery module",
"scope": "eq",
"trust": 0.3,
"vendor": "baxter",
"version": "0"
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 0.3,
"vendor": "baxter",
"version": "0"
},
{
"model": "wireless battery module",
"scope": "ne",
"trust": 0.3,
"vendor": "baxter",
"version": "16"
},
{
"model": "sigma spectrum infusion system",
"scope": "ne",
"trust": 0.3,
"vendor": "baxter",
"version": "6.05"
}
],
"sources": [
{
"db": "BID",
"id": "76895"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008654"
},
{
"db": "NVD",
"id": "CVE-2014-5434"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:6.05:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:16:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2014-5434"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Jared Bird of Allina IS Security",
"sources": [
{
"db": "BID",
"id": "76895"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-775"
}
],
"trust": 0.9
},
"cve": "CVE-2014-5434",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2014-5434",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-73376",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2014-5434",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2014-5434",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-201510-775",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-73376",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-73376"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008654"
},
{
"db": "NVD",
"id": "CVE-2014-5434"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-775"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes. Baxter SIGMA Spectrum Infusion System Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Baxter Wireless Battery Module (WBM) is prone to multiple security vulnerabilities. \nAttackers may exploit these issues to gain unauthorized access, obtain sensitive information, or bypass the authentication mechanism and gain access to the vulnerable device. Baxter SIGMA Spectrum Infusion System is an intelligent infusion system developed by Baxter, USA. A security vulnerability exists in Baxter WBM",
"sources": [
{
"db": "NVD",
"id": "CVE-2014-5434"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008654"
},
{
"db": "BID",
"id": "76895"
},
{
"db": "VULHUB",
"id": "VHN-73376"
}
],
"trust": 1.98
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2014-5434",
"trust": 2.8
},
{
"db": "ICS CERT",
"id": "ICSA-15-181-01",
"trust": 2.8
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008654",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201510-775",
"trust": 0.7
},
{
"db": "BID",
"id": "76895",
"trust": 0.3
},
{
"db": "VULHUB",
"id": "VHN-73376",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-73376"
},
{
"db": "BID",
"id": "76895"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008654"
},
{
"db": "NVD",
"id": "CVE-2014-5434"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-775"
}
]
},
"id": "VAR-201903-0661",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-73376"
}
],
"trust": 0.66
},
"last_update_date": "2023-12-18T12:28:26.409000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.baxter.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2014-008654"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-73376"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008654"
},
{
"db": "NVD",
"id": "CVE-2014-5434"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.8,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-15-181-01"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2014-5434"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-5434"
},
{
"trust": 0.3,
"url": "http://www.baxter.com/"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-73376"
},
{
"db": "BID",
"id": "76895"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008654"
},
{
"db": "NVD",
"id": "CVE-2014-5434"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-775"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-73376"
},
{
"db": "BID",
"id": "76895"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008654"
},
{
"db": "NVD",
"id": "CVE-2014-5434"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-775"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-03-26T00:00:00",
"db": "VULHUB",
"id": "VHN-73376"
},
{
"date": "2015-09-29T00:00:00",
"db": "BID",
"id": "76895"
},
{
"date": "2019-05-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-008654"
},
{
"date": "2019-03-26T15:29:00.287000",
"db": "NVD",
"id": "CVE-2014-5434"
},
{
"date": "2015-09-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201510-775"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-73376"
},
{
"date": "2015-09-29T00:00:00",
"db": "BID",
"id": "76895"
},
{
"date": "2019-05-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-008654"
},
{
"date": "2019-10-09T23:11:11.060000",
"db": "NVD",
"id": "CVE-2014-5434"
},
{
"date": "2019-10-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201510-775"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201510-775"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter SIGMA Spectrum Infusion System Vulnerabilities related to the use of hard-coded credentials",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2014-008654"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201510-775"
}
],
"trust": 0.6
}
}
VAR-201903-0659
Vulnerability from variot - Updated: 2023-12-18 12:28Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access account credentials and shared keys. Baxter asserts that this vulnerability only allows access to features and functionality on the WBM and that the SIGMA Spectrum infusion pump cannot be controlled from the WBM. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes. Baxter Wireless Battery Module (WBM) is prone to multiple security vulnerabilities. Attackers may exploit these issues to gain unauthorized access, obtain sensitive information, or bypass the authentication mechanism and gain access to the vulnerable device. A security vulnerability exists in Baxter WBM
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201903-0659",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 1.0,
"vendor": "baxter",
"version": "6.05"
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 0.8,
"vendor": "baxter",
"version": "6.05 (model 35700bax)"
},
{
"model": "wireless battery module",
"scope": "eq",
"trust": 0.3,
"vendor": "baxter",
"version": "0"
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 0.3,
"vendor": "baxter",
"version": "0"
},
{
"model": "wireless battery module",
"scope": "ne",
"trust": 0.3,
"vendor": "baxter",
"version": "16"
},
{
"model": "sigma spectrum infusion system",
"scope": "ne",
"trust": 0.3,
"vendor": "baxter",
"version": "6.05"
}
],
"sources": [
{
"db": "BID",
"id": "76895"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008652"
},
{
"db": "NVD",
"id": "CVE-2014-5432"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:6.05:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:16:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2014-5432"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Jared Bird of Allina IS Security",
"sources": [
{
"db": "BID",
"id": "76895"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-773"
}
],
"trust": 0.9
},
"cve": "CVE-2014-5432",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2014-5432",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-73373",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2014-5432",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2014-5432",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-201510-773",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-73373",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-73373"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008652"
},
{
"db": "NVD",
"id": "CVE-2014-5432"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-773"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access account credentials and shared keys. Baxter asserts that this vulnerability only allows access to features and functionality on the WBM and that the SIGMA Spectrum infusion pump cannot be controlled from the WBM. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes. Baxter Wireless Battery Module (WBM) is prone to multiple security vulnerabilities. \nAttackers may exploit these issues to gain unauthorized access, obtain sensitive information, or bypass the authentication mechanism and gain access to the vulnerable device. A security vulnerability exists in Baxter WBM",
"sources": [
{
"db": "NVD",
"id": "CVE-2014-5432"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008652"
},
{
"db": "BID",
"id": "76895"
},
{
"db": "VULHUB",
"id": "VHN-73373"
}
],
"trust": 1.98
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2014-5432",
"trust": 2.8
},
{
"db": "ICS CERT",
"id": "ICSA-15-181-01",
"trust": 2.8
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008652",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201510-773",
"trust": 0.7
},
{
"db": "BID",
"id": "76895",
"trust": 0.3
},
{
"db": "VULHUB",
"id": "VHN-73373",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-73373"
},
{
"db": "BID",
"id": "76895"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008652"
},
{
"db": "NVD",
"id": "CVE-2014-5432"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-773"
}
]
},
"id": "VAR-201903-0659",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-73373"
}
],
"trust": 0.66
},
"last_update_date": "2023-12-18T12:28:26.298000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.baxter.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2014-008652"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-287",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-73373"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008652"
},
{
"db": "NVD",
"id": "CVE-2014-5432"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.8,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-15-181-01"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2014-5432"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-5432"
},
{
"trust": 0.3,
"url": "http://www.baxter.com/"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-73373"
},
{
"db": "BID",
"id": "76895"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008652"
},
{
"db": "NVD",
"id": "CVE-2014-5432"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-773"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-73373"
},
{
"db": "BID",
"id": "76895"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008652"
},
{
"db": "NVD",
"id": "CVE-2014-5432"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-773"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-03-26T00:00:00",
"db": "VULHUB",
"id": "VHN-73373"
},
{
"date": "2015-09-29T00:00:00",
"db": "BID",
"id": "76895"
},
{
"date": "2019-05-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-008652"
},
{
"date": "2019-03-26T16:29:00.290000",
"db": "NVD",
"id": "CVE-2014-5432"
},
{
"date": "2015-09-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201510-773"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-73373"
},
{
"date": "2015-09-29T00:00:00",
"db": "BID",
"id": "76895"
},
{
"date": "2019-05-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-008652"
},
{
"date": "2019-10-09T23:11:10.730000",
"db": "NVD",
"id": "CVE-2014-5432"
},
{
"date": "2019-10-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201510-773"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201510-773"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter SIGMA Spectrum Infusion System Authentication vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2014-008652"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "authorization issue",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201510-773"
}
],
"trust": 0.6
}
}
VAR-201903-0660
Vulnerability from variot - Updated: 2023-12-18 12:28An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes. Baxter SIGMA Spectrum Infusion System Contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Baxter Wireless Battery Module (WBM) is prone to multiple security vulnerabilities. Attackers may exploit these issues to gain unauthorized access, obtain sensitive information, or bypass the authentication mechanism and gain access to the vulnerable device. Baxter SIGMA Spectrum Infusion System is an intelligent infusion system developed by Baxter, USA. A security vulnerability exists in Baxter WBM
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201903-0660",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 1.0,
"vendor": "baxter",
"version": "6.05"
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 0.8,
"vendor": "baxter",
"version": "6.05 (model 35700bax)"
},
{
"model": "wireless battery module",
"scope": "eq",
"trust": 0.3,
"vendor": "baxter",
"version": "0"
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 0.3,
"vendor": "baxter",
"version": "0"
},
{
"model": "wireless battery module",
"scope": "ne",
"trust": 0.3,
"vendor": "baxter",
"version": "16"
},
{
"model": "sigma spectrum infusion system",
"scope": "ne",
"trust": 0.3,
"vendor": "baxter",
"version": "6.05"
}
],
"sources": [
{
"db": "BID",
"id": "76895"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008653"
},
{
"db": "NVD",
"id": "CVE-2014-5433"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:6.05:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:16:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2014-5433"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Jared Bird of Allina IS Security",
"sources": [
{
"db": "BID",
"id": "76895"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-774"
}
],
"trust": 0.9
},
"cve": "CVE-2014-5433",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2014-5433",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-73375",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2014-5433",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2014-5433",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-201510-774",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-73375",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-73375"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008653"
},
{
"db": "NVD",
"id": "CVE-2014-5433"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-774"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes. Baxter SIGMA Spectrum Infusion System Contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Baxter Wireless Battery Module (WBM) is prone to multiple security vulnerabilities. \nAttackers may exploit these issues to gain unauthorized access, obtain sensitive information, or bypass the authentication mechanism and gain access to the vulnerable device. Baxter SIGMA Spectrum Infusion System is an intelligent infusion system developed by Baxter, USA. A security vulnerability exists in Baxter WBM",
"sources": [
{
"db": "NVD",
"id": "CVE-2014-5433"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008653"
},
{
"db": "BID",
"id": "76895"
},
{
"db": "VULHUB",
"id": "VHN-73375"
}
],
"trust": 1.98
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2014-5433",
"trust": 2.8
},
{
"db": "ICS CERT",
"id": "ICSA-15-181-01",
"trust": 2.8
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008653",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201510-774",
"trust": 0.7
},
{
"db": "BID",
"id": "76895",
"trust": 0.3
},
{
"db": "VULHUB",
"id": "VHN-73375",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-73375"
},
{
"db": "BID",
"id": "76895"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008653"
},
{
"db": "NVD",
"id": "CVE-2014-5433"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-774"
}
]
},
"id": "VAR-201903-0660",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-73375"
}
],
"trust": 0.66
},
"last_update_date": "2023-12-18T12:28:26.381000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.baxter.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2014-008653"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-255",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-73375"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008653"
},
{
"db": "NVD",
"id": "CVE-2014-5433"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.8,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-15-181-01"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2014-5433"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-5433"
},
{
"trust": 0.3,
"url": "http://www.baxter.com/"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-73375"
},
{
"db": "BID",
"id": "76895"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008653"
},
{
"db": "NVD",
"id": "CVE-2014-5433"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-774"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-73375"
},
{
"db": "BID",
"id": "76895"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008653"
},
{
"db": "NVD",
"id": "CVE-2014-5433"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-774"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-03-26T00:00:00",
"db": "VULHUB",
"id": "VHN-73375"
},
{
"date": "2015-09-29T00:00:00",
"db": "BID",
"id": "76895"
},
{
"date": "2019-05-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-008653"
},
{
"date": "2019-03-26T16:29:00.337000",
"db": "NVD",
"id": "CVE-2014-5433"
},
{
"date": "2015-09-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201510-774"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-73375"
},
{
"date": "2015-09-29T00:00:00",
"db": "BID",
"id": "76895"
},
{
"date": "2019-05-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-008653"
},
{
"date": "2019-10-09T23:11:10.873000",
"db": "NVD",
"id": "CVE-2014-5433"
},
{
"date": "2019-04-04T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201510-774"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201510-774"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter SIGMA Spectrum Infusion System Vulnerabilities related to certificate and password management",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2014-008653"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201510-774"
}
],
"trust": 0.6
}
}
VAR-201903-0658
Vulnerability from variot - Updated: 2023-12-18 12:28Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password may allow an attacker with physical access to the device to access management functions to make unauthorized configuration changes to biomedical settings such as turn on and off wireless connections and the phase-complete audible alarm that indicates the end of an infusion phase. Baxter has released a new version of the SIGMA Spectrum Infusion System, version 8, which incorporates hardware and software changes. Baxter SIGMA Spectrum Infusion System is a set of intelligent infusion system of Baxter company. Local attackers can use this vulnerability to bypass security restrictions and perform unauthorized operations
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201903-0658",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 1.0,
"vendor": "baxter",
"version": "6.05"
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 0.8,
"vendor": "baxter",
"version": "6.05 (model 35700bax)"
},
{
"model": "sigma spectrum infusion system",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
},
{
"model": "wireless battery module",
"scope": "eq",
"trust": 0.3,
"vendor": "baxter",
"version": "0"
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 0.3,
"vendor": "baxter",
"version": "0"
},
{
"model": "wireless battery module",
"scope": "ne",
"trust": 0.3,
"vendor": "baxter",
"version": "16"
},
{
"model": "sigma spectrum infusion system",
"scope": "ne",
"trust": 0.3,
"vendor": "baxter",
"version": "6.05"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-07336"
},
{
"db": "BID",
"id": "76898"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008651"
},
{
"db": "NVD",
"id": "CVE-2014-5431"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:6.05:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:16:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2014-5431"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Jared Bird with Allina IS Security",
"sources": [
{
"db": "BID",
"id": "76898"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-645"
}
],
"trust": 0.9
},
"cve": "CVE-2014-5431",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Local",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 4.6,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2014-5431",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.4,
"id": "CNVD-2015-07336",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "VHN-73372",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Physical",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.8,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2014-5431",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2014-5431",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2015-07336",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201510-645",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-73372",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-07336"
},
{
"db": "VULHUB",
"id": "VHN-73372"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008651"
},
{
"db": "NVD",
"id": "CVE-2014-5431"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-645"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password may allow an attacker with physical access to the device to access management functions to make unauthorized configuration changes to biomedical settings such as turn on and off wireless connections and the phase-complete audible alarm that indicates the end of an infusion phase. Baxter has released a new version of the SIGMA Spectrum Infusion System, version 8, which incorporates hardware and software changes. Baxter SIGMA Spectrum Infusion System is a set of intelligent infusion system of Baxter company. Local attackers can use this vulnerability to bypass security restrictions and perform unauthorized operations",
"sources": [
{
"db": "NVD",
"id": "CVE-2014-5431"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008651"
},
{
"db": "CNVD",
"id": "CNVD-2015-07336"
},
{
"db": "BID",
"id": "76898"
},
{
"db": "VULHUB",
"id": "VHN-73372"
}
],
"trust": 2.52
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2014-5431",
"trust": 3.4
},
{
"db": "ICS CERT",
"id": "ICSA-15-181-01",
"trust": 2.8
},
{
"db": "BID",
"id": "76898",
"trust": 1.0
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008651",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201510-645",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2015-07336",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-73372",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-07336"
},
{
"db": "VULHUB",
"id": "VHN-73372"
},
{
"db": "BID",
"id": "76898"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008651"
},
{
"db": "NVD",
"id": "CVE-2014-5431"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-645"
}
]
},
"id": "VAR-201903-0658",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-07336"
},
{
"db": "VULHUB",
"id": "VHN-73372"
}
],
"trust": 1.26
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-07336"
}
]
},
"last_update_date": "2023-12-18T12:28:26.345000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.baxter.com/"
},
{
"title": "Patch for Baxter SIGMA Spectrum Infusion System Local Security Bypass Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/66375"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-07336"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008651"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-73372"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008651"
},
{
"db": "NVD",
"id": "CVE-2014-5431"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.8,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-15-181-01"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2014-5431"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-5431"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/bid/76898"
},
{
"trust": 0.3,
"url": "http://www.baxter.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-07336"
},
{
"db": "VULHUB",
"id": "VHN-73372"
},
{
"db": "BID",
"id": "76898"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008651"
},
{
"db": "NVD",
"id": "CVE-2014-5431"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-645"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2015-07336"
},
{
"db": "VULHUB",
"id": "VHN-73372"
},
{
"db": "BID",
"id": "76898"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008651"
},
{
"db": "NVD",
"id": "CVE-2014-5431"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-645"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-11-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-07336"
},
{
"date": "2019-03-26T00:00:00",
"db": "VULHUB",
"id": "VHN-73372"
},
{
"date": "2015-09-29T00:00:00",
"db": "BID",
"id": "76898"
},
{
"date": "2019-05-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-008651"
},
{
"date": "2019-03-26T16:29:00.243000",
"db": "NVD",
"id": "CVE-2014-5431"
},
{
"date": "2015-09-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201510-645"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-11-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-07336"
},
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-73372"
},
{
"date": "2015-09-29T00:00:00",
"db": "BID",
"id": "76898"
},
{
"date": "2019-05-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-008651"
},
{
"date": "2019-10-09T23:11:10.560000",
"db": "NVD",
"id": "CVE-2014-5431"
},
{
"date": "2019-10-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201510-645"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "BID",
"id": "76898"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-645"
}
],
"trust": 0.9
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter SIGMA Spectrum Infusion System Vulnerabilities related to the use of hard-coded credentials",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2014-008651"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201510-645"
}
],
"trust": 0.6
}
}
VAR-202006-0330
Vulnerability from variot - Updated: 2023-12-18 11:21The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is rebooted. Baxter Spectrum Vulnerable to post-expiration or post-release resource manipulation vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Baxter WBM and Baxter Spectrum are both products of Baxter. Baxter WBM is a wireless battery module for Baxter products. Baxter Spectrum is an infusion pump.
There is a security vulnerability in Baxter Spectrum WBM. Attackers can use this vulnerability to gain access to the FTP service with the help of a specially crafted request
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202006-0330",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 1.0,
"vendor": "baxter",
"version": "8.0"
},
{
"model": "sigma spectrum infusion system",
"scope": null,
"trust": 0.8,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm",
"scope": "eq",
"trust": 0.6,
"vendor": "baxter",
"version": "17"
},
{
"model": "spectrum wbm 20d29",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm 20d30",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm 20d31",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm 22d24",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21076"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007456"
},
{
"db": "NVD",
"id": "CVE-2020-12043"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:17:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:20d29:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:20d30:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:20d31:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:22d24:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12043"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1223"
}
],
"trust": 0.6
},
"cve": "CVE-2020-12043",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-007456",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-21076",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-12043",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "HIGH",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-007456",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-12043",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-007456",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2021-21076",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202006-1223",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-12043",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21076"
},
{
"db": "VULMON",
"id": "CVE-2020-12043"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007456"
},
{
"db": "NVD",
"id": "CVE-2020-12043"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1223"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is rebooted. Baxter Spectrum Vulnerable to post-expiration or post-release resource manipulation vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Baxter WBM and Baxter Spectrum are both products of Baxter. Baxter WBM is a wireless battery module for Baxter products. Baxter Spectrum is an infusion pump. \n\r\n\r\nThere is a security vulnerability in Baxter Spectrum WBM. Attackers can use this vulnerability to gain access to the FTP service with the help of a specially crafted request",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12043"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007456"
},
{
"db": "CNVD",
"id": "CNVD-2021-21076"
},
{
"db": "VULMON",
"id": "CVE-2020-12043"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ICS CERT",
"id": "ICSMA-20-170-04",
"trust": 3.1
},
{
"db": "NVD",
"id": "CVE-2020-12043",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU91499991",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007456",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-21076",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "47312",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2020.2149",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1223",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-12043",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21076"
},
{
"db": "VULMON",
"id": "CVE-2020-12043"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007456"
},
{
"db": "NVD",
"id": "CVE-2020-12043"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1223"
}
]
},
"id": "VAR-202006-0330",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21076"
}
],
"trust": 1.5266666666666668
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21076"
}
]
},
"last_update_date": "2023-12-18T11:21:23.750000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.baxter.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007456"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-672",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007456"
},
{
"db": "NVD",
"id": "CVE-2020-12043"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-04"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-12043"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12043"
},
{
"trust": 0.8,
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-170-04"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91499991/"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/47312"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.2149/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/672.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-170-04"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21076"
},
{
"db": "VULMON",
"id": "CVE-2020-12043"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007456"
},
{
"db": "NVD",
"id": "CVE-2020-12043"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1223"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-21076"
},
{
"db": "VULMON",
"id": "CVE-2020-12043"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007456"
},
{
"db": "NVD",
"id": "CVE-2020-12043"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1223"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21076"
},
{
"date": "2020-06-29T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12043"
},
{
"date": "2020-08-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007456"
},
{
"date": "2020-06-29T14:15:11.817000",
"db": "NVD",
"id": "CVE-2020-12043"
},
{
"date": "2020-06-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1223"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21076"
},
{
"date": "2020-07-08T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12043"
},
{
"date": "2020-08-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007456"
},
{
"date": "2020-07-08T14:54:54.530000",
"db": "NVD",
"id": "CVE-2020-12043"
},
{
"date": "2020-07-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1223"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1223"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter Spectrum Vulnerability in manipulating resources after expiration or release in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007456"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1223"
}
],
"trust": 0.6
}
}
VAR-202006-0329
Vulnerability from variot - Updated: 2023-12-18 11:19The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary configuration changes to network settings of the WBM, and allows the WBM to be rebooted. Temporary configuration changes to network settings are removed upon reboot. Baxter Spectrum Includes a vulnerability in improper permission assignment for critical resources.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Baxter WBM and Baxter Spectrum are both products of Baxter. Baxter WBM is a wireless battery module for Baxter products. Baxter Spectrum is an infusion pump.
The WBM used in Baxter Spectrum has security vulnerabilities
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202006-0329",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 1.0,
"vendor": "baxter",
"version": "8.0"
},
{
"model": "sigma spectrum infusion system",
"scope": null,
"trust": 0.8,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm",
"scope": "eq",
"trust": 0.6,
"vendor": "baxter",
"version": "17"
},
{
"model": "spectrum wbm 20d29",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm 20d30",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm 20d31",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm 22d24",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21078"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007455"
},
{
"db": "NVD",
"id": "CVE-2020-12041"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:17:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:20d29:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:20d30:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:20d31:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:22d24:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12041"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1229"
}
],
"trust": 0.6
},
"cve": "CVE-2020-12041",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-007455",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-21078",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-12041",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "HIGH",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.5,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.4,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-007455",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-12041",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-007455",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2021-21078",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202006-1229",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-12041",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21078"
},
{
"db": "VULMON",
"id": "CVE-2020-12041"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007455"
},
{
"db": "NVD",
"id": "CVE-2020-12041"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1229"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary configuration changes to network settings of the WBM, and allows the WBM to be rebooted. Temporary configuration changes to network settings are removed upon reboot. Baxter Spectrum Includes a vulnerability in improper permission assignment for critical resources.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Baxter WBM and Baxter Spectrum are both products of Baxter. Baxter WBM is a wireless battery module for Baxter products. Baxter Spectrum is an infusion pump. \n\r\n\r\nThe WBM used in Baxter Spectrum has security vulnerabilities",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12041"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007455"
},
{
"db": "CNVD",
"id": "CNVD-2021-21078"
},
{
"db": "VULMON",
"id": "CVE-2020-12041"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ICS CERT",
"id": "ICSMA-20-170-04",
"trust": 3.1
},
{
"db": "NVD",
"id": "CVE-2020-12041",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU91499991",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007455",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-21078",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "47300",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2020.2149",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1229",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-12041",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21078"
},
{
"db": "VULMON",
"id": "CVE-2020-12041"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007455"
},
{
"db": "NVD",
"id": "CVE-2020-12041"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1229"
}
]
},
"id": "VAR-202006-0329",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21078"
}
],
"trust": 1.5266666666666668
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21078"
}
]
},
"last_update_date": "2023-12-18T11:19:55.851000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.baxter.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007455"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-732",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007455"
},
{
"db": "NVD",
"id": "CVE-2020-12041"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-04"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-12041"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12041"
},
{
"trust": 0.8,
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-170-04"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91499991/"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.2149/"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/47300"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/732.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-170-04"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21078"
},
{
"db": "VULMON",
"id": "CVE-2020-12041"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007455"
},
{
"db": "NVD",
"id": "CVE-2020-12041"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1229"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-21078"
},
{
"db": "VULMON",
"id": "CVE-2020-12041"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007455"
},
{
"db": "NVD",
"id": "CVE-2020-12041"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1229"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21078"
},
{
"date": "2020-06-29T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12041"
},
{
"date": "2020-08-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007455"
},
{
"date": "2020-06-29T14:15:11.757000",
"db": "NVD",
"id": "CVE-2020-12041"
},
{
"date": "2020-06-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1229"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21078"
},
{
"date": "2020-07-08T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12041"
},
{
"date": "2020-08-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007455"
},
{
"date": "2020-07-08T15:22:44.550000",
"db": "NVD",
"id": "CVE-2020-12041"
},
{
"date": "2020-07-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1229"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1229"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter Spectrum Vulnerability in improper permission assignment for critical resources in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007455"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1229"
}
],
"trust": 0.6
}
}
VAR-202006-0326
Vulnerability from variot - Updated: 2023-12-18 11:14Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed. The vulnerability is caused by the program containing a hard-coded password
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202006-0326",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sigma spectrum infusion system",
"scope": "gte",
"trust": 1.0,
"vendor": "baxter",
"version": "6.0"
},
{
"model": "sigma spectrum infusion system",
"scope": "lte",
"trust": 1.0,
"vendor": "baxter",
"version": "6.05"
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 1.0,
"vendor": "baxter",
"version": "8.0"
},
{
"model": "sigma spectrum infusion system",
"scope": null,
"trust": 0.8,
"vendor": "baxter",
"version": null
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 0.6,
"vendor": "baxter",
"version": "6.*"
},
{
"model": "spectrum infusion system",
"scope": "eq",
"trust": 0.6,
"vendor": "baxter",
"version": "8.*"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21081"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007530"
},
{
"db": "NVD",
"id": "CVE-2020-12039"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "6.05",
"versionStartIncluding": "6.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12039"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1235"
}
],
"trust": 0.6
},
"cve": "CVE-2020-12039",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "LOW",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Local",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 2.1,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-007530",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Low",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CNVD-2021-21081",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CVE-2020-12039",
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "LOW",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 2.4,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"exploitabilityScore": 0.9,
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Physical",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 2.4,
"baseSeverity": "Low",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "JVNDB-2020-007530",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-12039",
"trust": 1.0,
"value": "LOW"
},
{
"author": "NVD",
"id": "JVNDB-2020-007530",
"trust": 0.8,
"value": "Low"
},
{
"author": "CNVD",
"id": "CNVD-2021-21081",
"trust": 0.6,
"value": "LOW"
},
{
"author": "CNNVD",
"id": "CNNVD-202006-1235",
"trust": 0.6,
"value": "LOW"
},
{
"author": "VULMON",
"id": "CVE-2020-12039",
"trust": 0.1,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21081"
},
{
"db": "VULMON",
"id": "CVE-2020-12039"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007530"
},
{
"db": "NVD",
"id": "CVE-2020-12039"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1235"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v\u0027s6.x model 35700BAX \u0026 Baxter Spectrum Infusion System v\u0027s8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed. The vulnerability is caused by the program containing a hard-coded password",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12039"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007530"
},
{
"db": "CNVD",
"id": "CNVD-2021-21081"
},
{
"db": "VULMON",
"id": "CVE-2020-12039"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ICS CERT",
"id": "ICSMA-20-170-04",
"trust": 3.1
},
{
"db": "NVD",
"id": "CVE-2020-12039",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU91499991",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007530",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-21081",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "47304",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2020.2149",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1235",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-12039",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21081"
},
{
"db": "VULMON",
"id": "CVE-2020-12039"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007530"
},
{
"db": "NVD",
"id": "CVE-2020-12039"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1235"
}
]
},
"id": "VAR-202006-0326",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21081"
}
],
"trust": 1.38
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21081"
}
]
},
"last_update_date": "2023-12-18T11:14:21.050000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.baxter.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007530"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007530"
},
{
"db": "NVD",
"id": "CVE-2020-12039"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-04"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-12039"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12039"
},
{
"trust": 0.8,
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-170-04"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91499991/"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.2149/"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/47304"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/798.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-170-04"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21081"
},
{
"db": "VULMON",
"id": "CVE-2020-12039"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007530"
},
{
"db": "NVD",
"id": "CVE-2020-12039"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1235"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-21081"
},
{
"db": "VULMON",
"id": "CVE-2020-12039"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007530"
},
{
"db": "NVD",
"id": "CVE-2020-12039"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1235"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21081"
},
{
"date": "2020-06-29T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12039"
},
{
"date": "2020-08-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007530"
},
{
"date": "2020-06-29T14:15:11.617000",
"db": "NVD",
"id": "CVE-2020-12039"
},
{
"date": "2020-06-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1235"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21081"
},
{
"date": "2020-07-09T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12039"
},
{
"date": "2020-08-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007530"
},
{
"date": "2020-07-09T17:52:53.507000",
"db": "NVD",
"id": "CVE-2020-12039"
},
{
"date": "2020-07-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1235"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System and Baxter Spectrum Infusion System Vulnerability in using hard-coded credentials in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007530"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1235"
}
],
"trust": 0.6
}
}
VAR-202006-0332
Vulnerability from variot - Updated: 2023-12-18 11:07The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials. Baxter Spectrum Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Baxter WBM and Baxter Spectrum are both products of Baxter. Baxter WBM is a wireless battery module for Baxter products. Baxter Spectrum is an infusion pump.
The WBM used in Baxter Spectrum has a trust management vulnerability. Attackers can use hard-coded credentials to use this vulnerability to enable FTP services
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202006-0332",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 1.0,
"vendor": "baxter",
"version": "8.0"
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 0.8,
"vendor": "baxter",
"version": "8.x"
},
{
"model": "spectrum wbm",
"scope": "eq",
"trust": 0.6,
"vendor": "baxter",
"version": "17"
},
{
"model": "spectrum wbm 20d29",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm 20d30",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm 20d31",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm 22d24",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21077"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007458"
},
{
"db": "NVD",
"id": "CVE-2020-12047"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:17:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:20d29:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:20d30:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:20d31:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:22d24:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12047"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1228"
}
],
"trust": 0.6
},
"cve": "CVE-2020-12047",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-007458",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-21077",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-12047",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "HIGH",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-007458",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-12047",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-007458",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2021-21077",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202006-1228",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-12047",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21077"
},
{
"db": "VULMON",
"id": "CVE-2020-12047"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007458"
},
{
"db": "NVD",
"id": "CVE-2020-12047"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1228"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials. Baxter Spectrum Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Baxter WBM and Baxter Spectrum are both products of Baxter. Baxter WBM is a wireless battery module for Baxter products. Baxter Spectrum is an infusion pump. \n\r\n\r\nThe WBM used in Baxter Spectrum has a trust management vulnerability. Attackers can use hard-coded credentials to use this vulnerability to enable FTP services",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12047"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007458"
},
{
"db": "CNVD",
"id": "CNVD-2021-21077"
},
{
"db": "VULMON",
"id": "CVE-2020-12047"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ICS CERT",
"id": "ICSMA-20-170-04",
"trust": 3.1
},
{
"db": "NVD",
"id": "CVE-2020-12047",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU91499991",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007458",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-21077",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2020.2149",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "47298",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1228",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-12047",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21077"
},
{
"db": "VULMON",
"id": "CVE-2020-12047"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007458"
},
{
"db": "NVD",
"id": "CVE-2020-12047"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1228"
}
]
},
"id": "VAR-202006-0332",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21077"
}
],
"trust": 1.5266666666666668
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21077"
}
]
},
"last_update_date": "2023-12-18T11:07:41.014000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.baxter.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007458"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007458"
},
{
"db": "NVD",
"id": "CVE-2020-12047"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-04"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-12047"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12047"
},
{
"trust": 0.8,
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-170-04"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91499991/"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.2149/"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/47298"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/798.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-170-04"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21077"
},
{
"db": "VULMON",
"id": "CVE-2020-12047"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007458"
},
{
"db": "NVD",
"id": "CVE-2020-12047"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1228"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-21077"
},
{
"db": "VULMON",
"id": "CVE-2020-12047"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007458"
},
{
"db": "NVD",
"id": "CVE-2020-12047"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1228"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21077"
},
{
"date": "2020-06-29T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12047"
},
{
"date": "2020-08-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007458"
},
{
"date": "2020-06-29T14:15:11.943000",
"db": "NVD",
"id": "CVE-2020-12047"
},
{
"date": "2020-06-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1228"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21077"
},
{
"date": "2020-07-08T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12047"
},
{
"date": "2020-08-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007458"
},
{
"date": "2020-07-08T15:08:32.127000",
"db": "NVD",
"id": "CVE-2020-12047"
},
{
"date": "2020-07-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1228"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1228"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter Spectrum Vulnerability in using hard-coded credentials in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007458"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1228"
}
],
"trust": 0.6
}
}
VAR-202006-0328
Vulnerability from variot - Updated: 2023-12-18 11:05Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has circumvented network security measures to view sensitive non-private data or to perform a man-in-the-middle attack. (DoS) It may be put into a state. Baxter Sigma Spectrum Infusion System and Baxter Spectrum Infusion System are both infusion pumps of Baxter
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202006-0328",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sigma spectrum infusion system",
"scope": "gte",
"trust": 1.0,
"vendor": "baxter",
"version": "6.0"
},
{
"model": "sigma spectrum infusion system",
"scope": "lte",
"trust": 1.0,
"vendor": "baxter",
"version": "6.05"
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 1.0,
"vendor": "baxter",
"version": "8.0"
},
{
"model": "sigma spectrum infusion system",
"scope": null,
"trust": 0.8,
"vendor": "baxter",
"version": null
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 0.6,
"vendor": "baxter",
"version": "6.*"
},
{
"model": "spectrum infusion system",
"scope": "eq",
"trust": 0.6,
"vendor": "baxter",
"version": "8.*"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21080"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007531"
},
{
"db": "NVD",
"id": "CVE-2020-12040"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "6.05",
"versionStartIncluding": "6.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12040"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1234"
}
],
"trust": 0.6
},
"cve": "CVE-2020-12040",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-007531",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-21080",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-12040",
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "MEDIUM",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-007531",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-12040",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-007531",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2021-21080",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202006-1234",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-12040",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21080"
},
{
"db": "VULMON",
"id": "CVE-2020-12040"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007531"
},
{
"db": "NVD",
"id": "CVE-2020-12040"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1234"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Sigma Spectrum Infusion System v\u0027s6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has circumvented network security measures to view sensitive non-private data or to perform a man-in-the-middle attack. (DoS) It may be put into a state. Baxter Sigma Spectrum Infusion System and Baxter Spectrum Infusion System are both infusion pumps of Baxter",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12040"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007531"
},
{
"db": "CNVD",
"id": "CNVD-2021-21080"
},
{
"db": "VULMON",
"id": "CVE-2020-12040"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ICS CERT",
"id": "ICSMA-20-170-04",
"trust": 3.1
},
{
"db": "NVD",
"id": "CVE-2020-12040",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU91499991",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007531",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-21080",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "47302",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2020.2149",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1234",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-12040",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21080"
},
{
"db": "VULMON",
"id": "CVE-2020-12040"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007531"
},
{
"db": "NVD",
"id": "CVE-2020-12040"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1234"
}
]
},
"id": "VAR-202006-0328",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21080"
}
],
"trust": 1.38
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21080"
}
]
},
"last_update_date": "2023-12-18T11:05:43.181000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.baxter.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007531"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-319",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007531"
},
{
"db": "NVD",
"id": "CVE-2020-12040"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-04"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-12040"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12040"
},
{
"trust": 0.8,
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-170-04"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91499991/"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/47302"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.2149/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/319.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-170-04"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21080"
},
{
"db": "VULMON",
"id": "CVE-2020-12040"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007531"
},
{
"db": "NVD",
"id": "CVE-2020-12040"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1234"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-21080"
},
{
"db": "VULMON",
"id": "CVE-2020-12040"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007531"
},
{
"db": "NVD",
"id": "CVE-2020-12040"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1234"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21080"
},
{
"date": "2020-06-29T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12040"
},
{
"date": "2020-08-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007531"
},
{
"date": "2020-06-29T14:15:11.677000",
"db": "NVD",
"id": "CVE-2020-12040"
},
{
"date": "2020-06-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1234"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21080"
},
{
"date": "2020-07-09T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12040"
},
{
"date": "2020-08-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007531"
},
{
"date": "2020-07-09T17:58:57.613000",
"db": "NVD",
"id": "CVE-2020-12040"
},
{
"date": "2020-07-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1234"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1234"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Sigma Spectrum Infusion System and Baxter Spectrum Infusion System Vulnerability in plaintext transmission of important information in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007531"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1234"
}
],
"trust": 0.6
}
}
VAR-202006-0331
Vulnerability from variot - Updated: 2023-12-18 10:52The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials. Baxter Spectrum Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Baxter WBM and Baxter Spectrum are both products of Baxter. Baxter WBM is a wireless battery module for Baxter products. Baxter Spectrum is an infusion pump.
The WBM used in Baxter Spectrum has a security vulnerability. Attackers can use hard-coded credentials to exploit this vulnerability to run Telnet services
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202006-0331",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 1.0,
"vendor": "baxter",
"version": "8.0"
},
{
"model": "sigma spectrum infusion system",
"scope": "eq",
"trust": 0.8,
"vendor": "baxter",
"version": "8.x"
},
{
"model": "spectrum wbm",
"scope": "eq",
"trust": 0.6,
"vendor": "baxter",
"version": "17"
},
{
"model": "spectrum wbm 20d29",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm 20d30",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm 20d31",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
},
{
"model": "spectrum wbm 22d24",
"scope": null,
"trust": 0.6,
"vendor": "baxter",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21079"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007457"
},
{
"db": "NVD",
"id": "CVE-2020-12045"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:17:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:20d29:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:20d30:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:20d31:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:baxter:wireless_battery_module:22d24:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12045"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1231"
}
],
"trust": 0.6
},
"cve": "CVE-2020-12045",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-007457",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-21079",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-12045",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "HIGH",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-007457",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-12045",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-007457",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2021-21079",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202006-1231",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-12045",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21079"
},
{
"db": "VULMON",
"id": "CVE-2020-12045"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007457"
},
{
"db": "NVD",
"id": "CVE-2020-12045"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1231"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials. Baxter Spectrum Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Baxter WBM and Baxter Spectrum are both products of Baxter. Baxter WBM is a wireless battery module for Baxter products. Baxter Spectrum is an infusion pump. \n\r\n\r\nThe WBM used in Baxter Spectrum has a security vulnerability. Attackers can use hard-coded credentials to exploit this vulnerability to run Telnet services",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12045"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007457"
},
{
"db": "CNVD",
"id": "CNVD-2021-21079"
},
{
"db": "VULMON",
"id": "CVE-2020-12045"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ICS CERT",
"id": "ICSMA-20-170-04",
"trust": 3.1
},
{
"db": "NVD",
"id": "CVE-2020-12045",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU91499991",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007457",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-21079",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "47316",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2020.2149",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1231",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-12045",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21079"
},
{
"db": "VULMON",
"id": "CVE-2020-12045"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007457"
},
{
"db": "NVD",
"id": "CVE-2020-12045"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1231"
}
]
},
"id": "VAR-202006-0331",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21079"
}
],
"trust": 1.5266666666666668
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21079"
}
]
},
"last_update_date": "2023-12-18T10:52:03.315000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.baxter.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007457"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007457"
},
{
"db": "NVD",
"id": "CVE-2020-12045"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-04"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-12045"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12045"
},
{
"trust": 0.8,
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-170-04"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91499991/"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.2149/"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/47316"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/798.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-170-04"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21079"
},
{
"db": "VULMON",
"id": "CVE-2020-12045"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007457"
},
{
"db": "NVD",
"id": "CVE-2020-12045"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1231"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-21079"
},
{
"db": "VULMON",
"id": "CVE-2020-12045"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007457"
},
{
"db": "NVD",
"id": "CVE-2020-12045"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1231"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21079"
},
{
"date": "2020-06-29T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12045"
},
{
"date": "2020-08-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007457"
},
{
"date": "2020-06-29T14:15:11.880000",
"db": "NVD",
"id": "CVE-2020-12045"
},
{
"date": "2020-06-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1231"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21079"
},
{
"date": "2020-07-08T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12045"
},
{
"date": "2020-08-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007457"
},
{
"date": "2020-07-08T14:50:42.240000",
"db": "NVD",
"id": "CVE-2020-12045"
},
{
"date": "2020-07-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1231"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1231"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Baxter Spectrum WBM trust management issue vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21079"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1231"
}
],
"trust": 1.2
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1231"
}
],
"trust": 0.6
}
}
CVE-2014-5431 (GCVE-0-2014-5431)
Vulnerability from cvelistv5 – Published: 2019-03-26 15:37 – Updated: 2024-08-06 11:41- CWE-259 - Hard-coded password CWE-259
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Baxter | SIGMA Spectrum Infusion System |
Affected:
6.05 (model 35700BAX) with wireless battery module (WBM) version 16
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T11:41:49.207Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIGMA Spectrum Infusion System",
"vendor": "Baxter",
"versions": [
{
"status": "affected",
"version": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
}
]
}
],
"datePublic": "2015-06-30T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password may allow an attacker with physical access to the device to access management functions to make unauthorized configuration changes to biomedical settings such as turn on and off wireless connections and the phase-complete audible alarm that indicates the end of an infusion phase. Baxter has released a new version of the SIGMA Spectrum Infusion System, version 8, which incorporates hardware and software changes."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "Hard-coded password CWE-259",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-26T15:37:49",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-5431",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIGMA Spectrum Infusion System",
"version": {
"version_data": [
{
"version_value": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
}
]
}
}
]
},
"vendor_name": "Baxter"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password may allow an attacker with physical access to the device to access management functions to make unauthorized configuration changes to biomedical settings such as turn on and off wireless connections and the phase-complete audible alarm that indicates the end of an infusion phase. Baxter has released a new version of the SIGMA Spectrum Infusion System, version 8, which incorporates hardware and software changes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Hard-coded password CWE-259"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-5431",
"datePublished": "2019-03-26T15:37:49",
"dateReserved": "2014-08-22T00:00:00",
"dateUpdated": "2024-08-06T11:41:49.207Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-5432 (GCVE-0-2014-5432)
Vulnerability from cvelistv5 – Published: 2019-03-26 15:17 – Updated: 2024-08-06 11:41- CWE-592 - Authentication bypass issues CWE-592
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Baxter | SIGMA Spectrum Infusion System |
Affected:
6.05 (model 35700BAX) with wireless battery module (WBM) version 16.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T11:41:49.211Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIGMA Spectrum Infusion System",
"vendor": "Baxter",
"versions": [
{
"status": "affected",
"version": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16."
}
]
}
],
"datePublic": "2015-06-30T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access account credentials and shared keys. Baxter asserts that this vulnerability only allows access to features and functionality on the WBM and that the SIGMA Spectrum infusion pump cannot be controlled from the WBM. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-592",
"description": "Authentication bypass issues CWE-592",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-26T15:17:16",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-5432",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIGMA Spectrum Infusion System",
"version": {
"version_data": [
{
"version_value": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16."
}
]
}
}
]
},
"vendor_name": "Baxter"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access account credentials and shared keys. Baxter asserts that this vulnerability only allows access to features and functionality on the WBM and that the SIGMA Spectrum infusion pump cannot be controlled from the WBM. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Authentication bypass issues CWE-592"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-5432",
"datePublished": "2019-03-26T15:17:16",
"dateReserved": "2014-08-22T00:00:00",
"dateUpdated": "2024-08-06T11:41:49.211Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-5433 (GCVE-0-2014-5433)
Vulnerability from cvelistv5 – Published: 2019-03-26 15:07 – Updated: 2024-08-06 11:41- CWE-312 - Cleartext storage of sensitive information CWE-312
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Baxter | SIGMA Spectrum Infusion System |
Affected:
6.05 (model 35700BAX) with wireless battery module (WBM) version 16
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T11:41:49.305Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIGMA Spectrum Infusion System",
"vendor": "Baxter",
"versions": [
{
"status": "affected",
"version": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
}
]
}
],
"datePublic": "2015-06-30T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "Cleartext storage of sensitive information CWE-312",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-26T15:07:39",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-5433",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIGMA Spectrum Infusion System",
"version": {
"version_data": [
{
"version_value": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
}
]
}
}
]
},
"vendor_name": "Baxter"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cleartext storage of sensitive information CWE-312"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-5433",
"datePublished": "2019-03-26T15:07:39",
"dateReserved": "2014-08-22T00:00:00",
"dateUpdated": "2024-08-06T11:41:49.305Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-5434 (GCVE-0-2014-5434)
Vulnerability from cvelistv5 – Published: 2019-03-26 14:59 – Updated: 2024-08-06 11:41- CWE-259 - Hard-coded password CWE-259
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Baxter | SIGMA Spectrum Infusion System |
Affected:
6.05 (model 35700BAX) with wireless battery module (WBM) version 16
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T11:41:49.088Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIGMA Spectrum Infusion System",
"vendor": "Baxter",
"versions": [
{
"status": "affected",
"version": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
}
]
}
],
"datePublic": "2015-06-30T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "Hard-coded password CWE-259",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-26T14:59:52",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-5434",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIGMA Spectrum Infusion System",
"version": {
"version_data": [
{
"version_value": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
}
]
}
}
]
},
"vendor_name": "Baxter"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Hard-coded password CWE-259"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-5434",
"datePublished": "2019-03-26T14:59:52",
"dateReserved": "2014-08-22T00:00:00",
"dateUpdated": "2024-08-06T11:41:49.088Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-5431 (GCVE-0-2014-5431)
Vulnerability from nvd – Published: 2019-03-26 15:37 – Updated: 2024-08-06 11:41- CWE-259 - Hard-coded password CWE-259
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Baxter | SIGMA Spectrum Infusion System |
Affected:
6.05 (model 35700BAX) with wireless battery module (WBM) version 16
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T11:41:49.207Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIGMA Spectrum Infusion System",
"vendor": "Baxter",
"versions": [
{
"status": "affected",
"version": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
}
]
}
],
"datePublic": "2015-06-30T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password may allow an attacker with physical access to the device to access management functions to make unauthorized configuration changes to biomedical settings such as turn on and off wireless connections and the phase-complete audible alarm that indicates the end of an infusion phase. Baxter has released a new version of the SIGMA Spectrum Infusion System, version 8, which incorporates hardware and software changes."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "Hard-coded password CWE-259",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-26T15:37:49",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-5431",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIGMA Spectrum Infusion System",
"version": {
"version_data": [
{
"version_value": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
}
]
}
}
]
},
"vendor_name": "Baxter"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password may allow an attacker with physical access to the device to access management functions to make unauthorized configuration changes to biomedical settings such as turn on and off wireless connections and the phase-complete audible alarm that indicates the end of an infusion phase. Baxter has released a new version of the SIGMA Spectrum Infusion System, version 8, which incorporates hardware and software changes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Hard-coded password CWE-259"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-5431",
"datePublished": "2019-03-26T15:37:49",
"dateReserved": "2014-08-22T00:00:00",
"dateUpdated": "2024-08-06T11:41:49.207Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-5432 (GCVE-0-2014-5432)
Vulnerability from nvd – Published: 2019-03-26 15:17 – Updated: 2024-08-06 11:41- CWE-592 - Authentication bypass issues CWE-592
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Baxter | SIGMA Spectrum Infusion System |
Affected:
6.05 (model 35700BAX) with wireless battery module (WBM) version 16.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T11:41:49.211Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIGMA Spectrum Infusion System",
"vendor": "Baxter",
"versions": [
{
"status": "affected",
"version": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16."
}
]
}
],
"datePublic": "2015-06-30T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access account credentials and shared keys. Baxter asserts that this vulnerability only allows access to features and functionality on the WBM and that the SIGMA Spectrum infusion pump cannot be controlled from the WBM. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-592",
"description": "Authentication bypass issues CWE-592",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-26T15:17:16",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-5432",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIGMA Spectrum Infusion System",
"version": {
"version_data": [
{
"version_value": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16."
}
]
}
}
]
},
"vendor_name": "Baxter"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access account credentials and shared keys. Baxter asserts that this vulnerability only allows access to features and functionality on the WBM and that the SIGMA Spectrum infusion pump cannot be controlled from the WBM. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Authentication bypass issues CWE-592"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-5432",
"datePublished": "2019-03-26T15:17:16",
"dateReserved": "2014-08-22T00:00:00",
"dateUpdated": "2024-08-06T11:41:49.211Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-5433 (GCVE-0-2014-5433)
Vulnerability from nvd – Published: 2019-03-26 15:07 – Updated: 2024-08-06 11:41- CWE-312 - Cleartext storage of sensitive information CWE-312
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Baxter | SIGMA Spectrum Infusion System |
Affected:
6.05 (model 35700BAX) with wireless battery module (WBM) version 16
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T11:41:49.305Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIGMA Spectrum Infusion System",
"vendor": "Baxter",
"versions": [
{
"status": "affected",
"version": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
}
]
}
],
"datePublic": "2015-06-30T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "Cleartext storage of sensitive information CWE-312",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-26T15:07:39",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-5433",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIGMA Spectrum Infusion System",
"version": {
"version_data": [
{
"version_value": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
}
]
}
}
]
},
"vendor_name": "Baxter"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cleartext storage of sensitive information CWE-312"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-5433",
"datePublished": "2019-03-26T15:07:39",
"dateReserved": "2014-08-22T00:00:00",
"dateUpdated": "2024-08-06T11:41:49.305Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-5434 (GCVE-0-2014-5434)
Vulnerability from nvd – Published: 2019-03-26 14:59 – Updated: 2024-08-06 11:41- CWE-259 - Hard-coded password CWE-259
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Baxter | SIGMA Spectrum Infusion System |
Affected:
6.05 (model 35700BAX) with wireless battery module (WBM) version 16
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T11:41:49.088Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIGMA Spectrum Infusion System",
"vendor": "Baxter",
"versions": [
{
"status": "affected",
"version": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
}
]
}
],
"datePublic": "2015-06-30T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "Hard-coded password CWE-259",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-26T14:59:52",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-5434",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIGMA Spectrum Infusion System",
"version": {
"version_data": [
{
"version_value": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
}
]
}
}
]
},
"vendor_name": "Baxter"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Hard-coded password CWE-259"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-5434",
"datePublished": "2019-03-26T14:59:52",
"dateReserved": "2014-08-22T00:00:00",
"dateUpdated": "2024-08-06T11:41:49.088Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",